The iTrack reader can either be supplied with a new unit or retrofitted to existing oness. See below for a wiring diagram:

Existing iTrack Reader

If the iTrack reader has been set up at the factory, it will connect to the prewired sockets on the DIN rail as follows:

Isolate the unit before attempting any work on the iTrack reader.

Compac Industries Ltd.

Page 109 www.compac.co.nz

iTrack Reader Installation and Replacement

Service and Upgrade Procedures

New Installation

Terminal

Tx

Wires

Red

iTrack Reader Wires

Orange and White

Rx

12V

Black

White

Orange

Blue and White

G Blue, Green and Shield Blue

To connect an iTrack reader where no DIN rail connection is supplied you can wire the reader to an RS232 plug as follows:

Compac Industries Ltd.

The picture above shows the factory wiring. When wiring the

iTrack direct to the RS232 plug use the colours in the table.

Page 110 www.compac.co.nz

Service and Upgrade Procedures

iTrack Reader Installation and Replacement

Wire Pin

Orange / White 2

Orange

Blue

3

5

Plug the RS232 plug into the supplied socket (generally labelled "Host") and plug the ribbon cable at the back of this socket into Port 3 on the Com

FMS board.

Connect the Blue/White wire to the 12v supply side of socket J17 on the

C4000 board and the blue wire to the earth (twinned with the wire to RS252 pin 5).