- Industrial & lab equipment
- Electrical equipment & supplies
- Power conditioning
- Uninterruptible power supplies (UPSs)
- User manual
advertisement
▼
Scroll to page 2
of 98
35.5” 38.3”
59.3”
30”
40” 13.5”
Anchoring for 50 kVA 4200FA with Casters
2.7 Permanent Anchoring for Base and Seismic model 15/25/30/50 kVA UPS (without
Casters)
15/25/30 kVA Base/Seismic Anchoring Pattern 50 kVA Base/Seismic Anchoring Pattern
(Middle top/bottom holes N/A for Base 50kVA)
See Appendix A for fastener details.
4200FA Installation and Operation Manual 15
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 11 GENERAL SAFETY INSTRUCTIONS
- 12 EQUIPMENT WARNING LABELS
- 15 IMPORTANT SAFETY INSTRUCTIONS
- 19 Product Description
- 19 Theory of Operation
- 19 Application and Use
- 19 Power Backup
- 19 Power Conditioning
- 20 Product Unpacking / Inspection / Storage / Disposal
- 20 Unpack the Premium 15/25/30 kVA UPS (with Casters)
- 21 Unpack the Base and Seismic model 15/25/30 kVA UPS (without Casters)
- 22 Unpack the Premium 50 kVA UPS (with Casters)
- 23 Unpack the Base and Seismic 50 kVA UPS (without Casters)
- 24 Inspect UPS equipment After Unpacking
- 24 Permanent Anchoring for Premium 15/25/30/50 kVA UPS (with Casters)
- 25 Permanent Anchoring for Base and Seismic model 15/25/30/50 kVA UPS (without Casters)
- 26 Storage of UPS equipment
- 26 Disposal
- 27 Installation Precautions
- 27 Equipment Placement
- 28 System Preparation (Pre-Power)
- 28 Operating Precautions
- 29 UPS Connections
- 29 Power Connections
- 29 Power Connections 15/25/30 kVA with Internal Batteries
- 30 Power Connections 15/25/30 kVA with Internal Transformer
- 31 Recommended Wire Size and Torque Requirements for 15/25/30kVA
- 32 Power Connection Cable Routing and Conduit Placement 15/25/30 kVA
- 33 Control Circuit and External Battery Interface Connections 15/25/30 kVA
- 34 Recommended Wire Size and Torque Requirements
- 35 Power Connections 50 kVA
- 36 Recommended Wire Size and Torque Requirements for 50kVA
- 37 Power Connection Cable Routing and Conduit Placement 50 kVA
- 38 Control Circuit and External Interface Connections 50 kVA
- 39 4.4.1 Recommended Wire Size and Torque Requirements
- 40 Communication Interface
- 40 Remote Contact
- 41 RS-232C
- 42 UPS Shutdown (via RS-232C)
- 43 Specifications
- 44 4200FA 15 / 25 kVA @ 208 VAC Input/ 208 VAC Output w/Internal Batteries
- 45 4200FA 15/25 kVA w/Internal Transformer
- 46 Transformer
- 47 4200FA 30 kVA @ 208 VAC Input/ 208 VAC Output w/Internal Batteries
- 48 4200FA 30 kVA w/Internal Transformer
- 49 Transformer
- 50 4200FA 50kVA @ 208 VAC Input/ 208 VAC Output w/Internal Batteries
- 51 4200FA 50kVA w/Internal Transformer
- 52 4200FA Efficiencies and Thermal Losses at Various Loads
- 53 Operating the UPS
- 53 AC Input Mode (Normal Operation)
- 54 Bypass Mode
- 54 Bypass Mode for Optional Alternate Input Models
- 55 Battery Backup Mode
- 56 Battery Backup Time and Discharge Process
- 56 Battery Low Voltage Tolerances
- 57 Battery Recharging
- 58 Front Panel Layout (All Units)
- 58 EPO (Emergency Power Off) Function
- 59 Audible Alarm Functions
- 59 LED (Light Emitting Diode) Functions
- 60 LED (Light Emitting Diode) System Status
- 60 LCD (Liquid Crystal Display) Functions
- 60 Line-1 System Messages
- 61 Line-2 System Fault Messages
- 61 Line-3 System Messages
- 61 Line-4 System Messages
- 62 Menu Tree
- 62 Initial Battery Charge
- 63 Start-up Procedure
- 64 Shutdown Procedure
- 65 Maintenance Bypass Procedure
- 65 Switch from UPS to Maintenance Bypass
- 65 Switch from Maintenance Bypass to UPS
- 67 Keypad Overview
- 68 Key Functions
- 69 BATT Key
- 69 MENU, F1, ENTER, UP, & DOWN Keys
- 69 BATT TEST Key
- 70 BUZZ STOP Key
- 70 RESET Key
- 71 Menu Data Screens
- 71 Settings for Calendar and Clock
- 71 Adjusting the Buzzer Volume
- 71 Settings for Display Duration
- 72 Run Switch Select
- 72 Serial Com Station Address
- 73 Output Voltage Adjustment
- 73 Equalize Charge Mode Select
- 74 Reset to Default Settings
- 74 Overload Operation
- 75 Backup History and Fault History
- 77 UPS Protection System
- 77 System Protection Features
- 77 System Protection Functions
- 78 Start-up / Scheduled Maintenance / Part Replacement
- 78 Start-up
- 78 Preventive Maintenance
- 79 Parts Replacement
- 80 External Dimensions / Shipping Dimensions / Weights
- 80 External Dimensions – 15/25/30 kVA with Casters
- 81 External Dimensions – 15/25/30 kVA without Casters
- 82 External Dimensions – 50kVA with casters
- 83 External Dimensions – 50kVA without Casters
- 84 Dimensions and Weights
- 84 Cabinet Color
- 85 APPENDIX A – Seismic Anchorages
- 89 APPENDIX B – Installation Planning Guides