Example of topologies. Schneider Electric TSX 57/PCX 57 Implementation
Реклама
Реклама
TSX P ACC 01
2.3
Example of topologies
At a Glance
Aim of this
Section
What's in this
Section?
This Section introduces examples of how to use the TSX P ACC 01 device.
This section contains the following topics:
Topic
Connectable devices
UNI-TELWAY master mode
UNI-TELWAY slave mode
Connection between two PLCs
Page
58
TSX DM 57 xx
TSX P ACC 01
Connectable devices
General
The functionalities of the TER and AUX ports of the TSX P ACC 01 unit are identical to those of the TER and AUX connectors from the Premium/Atrium PLC processors.
l The unit's TER connector is used to connect any device supporting UNI-TELWAY protocol, in particular non-supplied devices (RS 485/RS 232 converter lead, l etc.).
The unit's AUX connector cannot be used to connect devices with a power supply
(operator dialog console, third party devices, etc.).
Note: The TSX P ACC 01 unit is supplied by the TER connector of the PLC to which it is connected. The unit's TER connector can therefore be used to supply self-powered devices (CCX 17, etc.) or non- powered devices (RS 485/RS 232 converter lead, etc.).
If you wish to connect the terminal port of a second PLC to one of the ports of the
TSX P ACC 01 unit, it is essential that you use the AUX connectors (from the unit and the PLC) in order not to put the supplies of the two PLCs into conflict.
Note: We strongly recommend that, after use, you do not leave a TSX PCU 103• or TSX PCX 1031 cable connected to the Uni-telway bus at one end and unconnected at the other.
Example 1:
Premium master Premium slave
T FTX CB 1020/1050
TSX P ACC 01
TSX DM 57 xx
59
TSX P ACC 01
Example 2:
Premium master
TSX RKY
T FTX CB 1020/1050
TSX P ACC 01
Atrium slave
60
TSX DM 57 xx
TSX P ACC 01
UNI-TELWAY master mode
Example
A TSX P ACC 01 device is connected to a UNI-TELWAY link master PLC as in the example below.
Switches S1 and S2 must be positioned on OFF (master mode).
Example on a Premium station:
FT 2100 slave
Premium master
Addresses 1, 2, 3
TSX PCX 1031
S1=OFF
S2=OFF
TSX SCA 50
Address 6
ATV 16
slave
UNI-TELWAY bus
TSX P ACC 01
TSX SCA 62
XBT-Z 968
TSX CSC 015
T CCX CB 10 002
CCX 17
slave
Addresses 4/5
TSX 17-20
slave
Addresses 7/8
1000 meters maximum
TSX DM 57 xx
61
TSX P ACC 01
Example on an Atrium station:
TSX RKY
FT 2100 slave host PC
Atrium master
Addresses 1, 2, 3
TSX PCX 1031
S1=OFF
S2=OFF
TSX SCA 50
UNI-TELWAY bus
TSX P ACC 01
XBT-Z 968
TSX SCA 62
Address 6
ATV 16
slave
TSX CSC 015
T CCX CB 10 002
CCX 17
slave
TSX 17-20
slave
Addresses 4/5
Addresses 7/8
1000 meters maximum
62
TSX DM 57 xx
TSX P ACC 01
UNI-TELWAY slave mode
Example
A TSX P ACC 01 device is connected to a UNI-TELWAY link slave PLC as in the example below.
Note: Important: For a PLC to be able to operate in slave mode it must be connected to a TSX P ACC 01 device by the cable built into it.
Illustration:
FT 2100
TSX 107-40 master
S1=ON
S2=ON
TSX P ACC 01
UNI-TELWAY bus
TSX CSB 015
S1=ON
S2=ON
TSX P ACC 01
TSX SCA 62
Premium
XBT-Z 968
TCCX CB10 002
CCX 17
1000 meters maximum
Atrium slave
TSX DM 57 xx
63
TSX P ACC 01
Connection between two PLCs
Reminders
If the user wants to connect the terminal port of a second PLC on one of the ports of the TSX P ACC 01 device, the AUX port must be used to avoid power supply conflicts in the two PLCs.
FT 2100
Note: Important: For a PLC to be able to work in slave mode it must be connected to a TSX P ACC 01 device by the device’s built-in cable.
In the example given below the TSX P ACC 01 device must therefore be connected to the UNI-TELWAY slave PLC by the device’s integrated cable. Its S1 switch must be positioned on ON
If the device if not placed on a UNI-TELWAY bus, the position of the S2 switch does not matter.
Illustration:
Premium master
Premium slave
T FTX CB1
020/050
S1=ON
S2=not significant
TSX PCX 1031
TSX P ACC 01
XBT-Z 968
T CCX CB10 002
CCX 17
64
TSX DM 57 xx
Processor-integrated master
FIPIO communication
II
At a Glance
Aim of this Part
What's in this
Part?
This Part deals with the master FIPIO communication function, which is integrated into Premium/Atrium processors.
This part contains the following chapters:
Chapter
3
Chapter Name
Processor-integrated master FIPIO communication
Page
TSX DM 57 xx
65
Integrated FIPIO
66
TSX DM 57 xx
Processor-integrated master
FIPIO communication
3
At a Glance
Aim of this
Chapter
What's in this
Chapter?
This Chapter deals with the FIPIO communication function integrated into Premium/
Atrium processors.
This chapter contains the following topics:
Topic
Review of the FIPIO bus
Integrated FIPIO link on Premium/Atrium processors
Examples of architecture
Page
67
TSX DM 57 xx
Integrated FIPIO
Review of the FIPIO bus
General
Main characteristics
68
FIPIO is a field bus which is used to centralize inputs/outputs of a PLC station and its industrial peripherals nearest to the section which is operating.
From a PLC station whose processor has a built-in FIPIO link, the FIPIO bus is used to connect 1 to 127 devices such as: l l l l l l l
Momentum remote input/output modules (discrete and analog)
TBX remote input/output modules (discrete and analog)
CCX 17 command consoles
ATV 16 variable speed controllers
Devices which conform to standard profiles
Agent PLCs, PC
...
The FIPIO field bus can be used in a single architecture (mono-station) or in a more complex architecture (multi-station) where several FIPIO segments can be brought together by a local network at a higher level such as FIPWAY or Ethernet TCP_IP for example.
Structure
Nature
Topology
Access method
Communication
Privileged exchanges
Open field bus, conforming to World FIP standards.
Links devices through chaining or branching.
Managed by a bus arbiter
By exchange of variables which can be accessed by the user in the form of PL7 objects and X-WAY datagrams.
Cyclical exchange of status variables and remote input/output commands
Transmission
Binary flow
Medium
1Mb/s.
Shielded twisted pair (150 Ohms of characteristic impedance).
Configuration
Number of connection points
Number of segments
PLC
128 logic connection points for whole architecture
15 maximum (in cascade format) using electrical or optical relays
(14 maximum in cascade format).
One PLC (address connection point 0)
TSX DM 57 xx
Integrated FIPIO
Configuration
Programming terminal One programming terminal (must be connected to connection point 63).
Length The length of a segment depends on its type of branches: l l
1000 meters maximum without relay.
15000 meters maximum between the devices which are the furthest apart.
TSX DM 57 xx
69
Integrated FIPIO
Integrated FIPIO link on Premium/Atrium processors
General
Some processors have as standard an integrated master FIPIO link which makes it possible to connect the PLC station to a FIPIO bus.
Illustration:
Link
FIPIO
Link
FIPIO
Premium processor
Link
FIPIO
Atrium processor
Connecting to the FIPIO bus
The processor has a SUB D 9-pin connector which is used to link it to the FIPIO bus using a TSX FP ACC12 connector.
Illustration:
70
TSX FP
ACC12
TSX FP
ACC12
The complete procedure for installing a FIPIO bus (architecture, type of cable to use, cabling accessories etc.) is discussed in the FIPIO Bus reference manual.
Note: The master FIPIO link integrated into processors should not be taken into account when counting the station channels.
TSX DM 57 xx
Examples of architecture
Premium station
Illustration:
Premium
X Bus
TSX RKY
Integrated FIPIO
TBX
Momentum
CCX 17
ATV
PC
TSX DM 57 xx
71
Integrated FIPIO
Atrium station
Illustration:
PC Atrium
TBX
Momentum
CCX 17
ATV
PC
TSX RKY
72
TSX DM 57 xx
AS-i bus interface: TSX SAY 100 module
III
At a Glance
Aim of this Part
What's in this
Part?
This Part deals with the AS-i bus interface module: TSX SAY 100.
This part contains the following chapters:
Chapter
4
Chapter Name
AS-i bus interface module: TSX SAY 100
Page
TSX DM 57 xx
73
TSX SAY 100
74
TSX DM 57 xx
AS-i bus interface module:
TSX SAY 100
4
At a Glance
Aim of this
Chapter
What's in this
Chapter?
This Chapter only deals with hardware installation of the TSX SAY 100 interface l l module, AS-i bus master on a Premium/Atrium PLC. For the complete installation of an AS-i bus you must refer to the following manuals:
AS-i bus reference manual
AS-i installation section in the Premium PLC Applications Manual - Applications,
Volume 1.
This chapter contains the following sections:
Section
4.1
4.2
4.3
4.4
4.5
4.6
Topic
Review of the AS-i bus
Description of the TSX SAY 100 module
Input/output object addressing
AS-i Bus diagnostics
Operating modes of the TSX SAY 100 module
Precautions of use
Page
75
TSX DM 57 xx