User Parameter Descriptions. Omron Varispeed L7
광고
광고
4
-2
User Parameter Descriptions
This section describes the contents of the user parameter tables.
Description of User Parameter Tables
User parameter tables are structured as shown below. Here, b1-01 (Frequency Reference Selection) is used as an example.
Parameter Number
Name
Display
Description
Setting
Range
Factory
Setting
Change during
Operation
Control Methods MEMO-
BUS
V/f
Open
Loop
Vector
Closed
Loop
Vector
Register
Page b1-01
Reference selection
Sets the frequency reference input method.
0: Digital Operator/Monitor
1: Control circuit terminal
(analog input)
2: MEMOBUS communications
3: Option Card
0 to 3 0 No Q Q Q 180H -
• Parameter Number:
• Name:
• Display
• Description:
• Setting Range:
• Factory Setting:
• Change during Operation:
• Control Methods:
• MEMOBUS Register:
• Page:
The number of the user parameter.
The name of the user parameter.
The display shown in the Digital Operator JVOP-160
Details on the function or settings of the user parameter.
The setting range for the user parameter.
The factory setting (each control method has its own factory setting.
Therefore the factory setting changes when the control method is changed.)
page 4-51, Factory Settings that Change with the Control Method (A1-02)
for factory settings that are changed by setting the control method.
Indicates whether the parameter can be changed or not while the
Inverter is in operation.
Yes: Changes are possible during operation.
No: Changes are not possible during operation.
Indicates the control methods in which the user parameter can be monitored or set.
Q: The item can be monitored and set as well in quick programming mode as in advanced programming mode.
A: The item can be monitored and set in advanced programming mode only.
No: The item cannot be monitored or set in this control method.
The register number used for MEMOBUS communications.
Reference page for more detailed information about the parameter.