System Functions 61

Hold Down Functions

Hold down function have been incorporated to allow easy activation of specific operations. When a button is held down for two seconds, two beeps will be heard and a particular function will operate. The functions available are listed below.

#

Arm The System In AWAY Mode

Holding the button down until two beeps are heard will arm the system in the AWAY Mode. Refer to Option 2 in

"LOCATION 670" on page 159 for setting this feature.

If the system has been partitioned, holding the button down until two beeps are heard on the “CP5 Area

Addressable (CP500A)” codepad will only arm the area that the codepad is allocated to in AWAY Mode.

This hold down function does not operate on the "CP5 Master Partitioned (CP500P)" codepad as pressing the button will toggle you to the next area display.

*

Arm The System In STAY Mode 1

Holding the button down until two beeps are heard will arm the system in STAY Mode 1. Option 2 in

"LOCATION 670" on page 159 will need to be enabled for this function to operate.

If there has not been an alarm during the armed cycle, holding the button down a second time will disarm the system from STAY Mode 1. Option 4 in "LOCATION 670" on page 159 will need to be enabled for this hold down function to operate.

If an alarm has occurred or entry warning has been triggered, a valid user code will need to be used to disarm the system.

If the system has been partitioned, holding down the button on the “CP5 Area Addressable (CP500A)” codepad will only arm the area that the codepad belongs to in STAY Mode 1. This function does not operate on the "CP5 Master

Partitioned (CP500P)" codepad.

0

Arm The System In STAY Mode 2

Holding the

0

button down until two beeps are heard will arm the system in STAY Mode 2. Option 2 in "LOCATION

670" on page 159 will need to be enabled for this function to operate.

If there has not been an alarm during the armed cycle, holding the

0

button down again until two beeps are heard will disarm the system. Option 4 in "LOCATION 670" on page 159 will need to be enabled for this hold down function to operate.

If an alarm has occurred or entry warning has been triggered, a valid user code will need to be used to disarm the system.

STAY Mode 2 is not available when the system has been partitioned, therefore this hold down function does not operate when the system has been partitioned.

1

Horn Speaker Test

Holding the

1

button down until two beeps are heard will sound the horn speaker for a two second burst. No other sounding device will sound in this mode. If An EDMSAT (SS914) has been connected to the control panel, this function will test the horn speaker for a two second burst followed by the strobe connected to the satellite siren.