Preparing for ECC Installation. Compuware Compuware Installer, License Management System, Compuware Shared Services, Host Communications Interface
Reklama
Reklama
2-1
Chapter 2.
Preparing for ECC Installation
This chapter contains important information that can help you prepare to install the
Enterprise Common Components (ECC) in the most efficient manner. Review it before beginning the installation process.
Required Components and Procedures
This section explains how to determine which parts of ECC need to be installed at your site and which chapters in this manual contain the applicable customization procedures.
Component Selection
Different Compuware products utilize different portions of ECC. Use Table 2-1 to
determine which parts of ECC are needed at your site.
Notice that Compuware’s License Management System (LMS) is required for every mainframe product, while HCI and CSS are components for some products.
Table 2-1.
Components Utilized by Each Compuware Product
Compuware Product LMS CSS
Abend-AID x x
Abend-AID Fault Analytics
Abend-AID for CICS
File-AID/Data Solutions
File-AID for DB2 x x x x x x
HCI*
x x
File-AID for IMS x
File-AID/MVS x
File-AID/RDX
Hiperstation x x
Strobe x
Xpediter/CICS x x x x** x
Xpediter/Code Coverage
DevEnterprise
Compuware Workbench/Topaz
Xpediter/TSO and /IMS x x x x x x x x x
Xpediter/Xchange x
* HCI can be optionally installed from the ECC distributed media. Please refer to individual product’s documentation for configuration and customization instructions.
** HCI is only required if using the Hiperstation viewer.
2-2
Enterprise Common Components Installation and Customization Guide
Required Procedures
Determining which chapters to use in this manual is actually very simple:
• Every mainframe Compuware product uses LMS. Therefore, every installation of a
Compuware product requires, at a minimum, that the latest maintenance be applied to LMS. So regardless of which product you are installing, you must perform the applicable procedures in the following chapters:
– Chapter 3, “Installing Enterprise Common Components” (if current release has not been previously installed)
– Chapter 4, “Applying Maintenance”
– Chapter 6, “LMS Customization”
• If the Compuware product you are installing requires CSS, you must also perform the
procedures in Chapter 5, “CSS Customization”.
The information within each chapter will direct you as to which steps apply in your situation.
Note: If you are installing the Host Communications Interface (HCI) components, refer
to each product manual that uses HCI for specific customization/configuration instructions. The Host Communications Interface User/Reference manual does
not contain configuration or customization information for specific products
and should not be used to configure HCI.
ECC Packaging
The ECC product media or as part of a Receive from Network (RFN) order, includes LMS,
CSS, and HCI, is packaged for installation using System Modification Program Extended
(SMP/E). SMP/E is a method developed by IBM to install software products in the MVS environment.
SMP/E provides enhanced installation management and maintenance tracking capabilities. To facilitate SMP/E, the LMS, CSS, and HCI components are shipped separately from the products, via RFN or via the ECC EP physical media (upon request).
The ECC software is distributed with both the base code and all cumulative, approved maintenance to-date. To install the ECC, refer to Chapter 3, “Installing Enterprise
Common Components”.
The installation is facilitated by the Compuware Installer consisting of a set of REXX
EXECs, JCL skeletons, and panels. This facility prompts you for the installation information and then builds the necessary jobs required to perform the SMP/E installation. You can also view reporting information from the installation facility, such as parameters and execution information.
Cumulative maintenance for ECC components is available for download from the
Compuware GO/Frontline web site (http://go.compuware.com). It is recommended that you periodically download and apply cumulative maintenance to keep your product version current.
ECC Component Prefixes and FMIDs
Compuware has registered the following element prefixes with IBM for the ECC components:
• LCX for CSS
• LMS for LMS
• LHC for HCI
Preparing for ECC Installation
2-3
The FMIDs for each component are listed below.
• MLCXnnn — CSS base code
• NLCXnnn — CSS Japanese support
• MLMSnnn — LMS base code
• MLHCnnn — HCI base code
ECC Installation Considerations
This section describes considerations for installing and customizing ECC that applies to
LMS, CSS, and/or HCI. Check your mainframe product installation documentation to verify if these any of the ECC component applications have already been installed. If
they are installed, you may consider only applying maintenance. See Chapter 4,
“Applying Maintenance” for more information.
Link Lists
Refer to your Compuware product documentation to determine whether the load library or libraries for your components should be placed in the link list.
PDS/E Support
ECC components support Partitioned Data Set/Extended (PDS/E) libraries. LMS, CSS, and/or HCI can be installed in PDS/E object libraries. Input source members for the CSS preprocessor or compiled listings for the CSS post-processor may reside in a data PDS/E library. The following are supported for PDS/E libraries:
• PDS/E object libraries are supported with DFSMS 1.1 and above.
• PDS/E data libraries are supported with DFSMS 1.0 and above.
CSS Installation Considerations
This section describes considerations for installing Compuware Shared Services.
APF Authorization
Following IBM system integrity guidelines, Compuware recommends that your CSS load
Library (SLCXLOAD) NOT be APF-authorized. Depending on your MVS system installation options, libraries placed in the link list may be APF-authorized automatically.
Note: If you are using Abend-AID and Abend-AID is APF-authorized, then CSS should
also be APF-authorized. If Abend-AID is not APF-authorized, then CSS should not be APF-authorized. The ONLY time the CSS load library should be APF-authorized is when you are using the Abend-AID load library as APF-authorized.
If you will be installing and configuring the Compuware Workbench Mainframe Interface
TP, this component does require an APF-authorized library. However, this component will install into a separate and very small load library (SLCXAUTH) and the main CSS load library need not be APF-authorized subject to the note above.
CICS Load Library Definition
The CSS library must be included with Compuware product libraries in the CICS startup
JCL or RDO definitions for the following product:
• Xpediter/CICS (all supported releases)
2-4
Enterprise Common Components Installation and Customization Guide
TSO Logon PROCs
If the CSS load library is not in the link list and dynamic library allocation is not used, the CSS load library must be placed before all Compuware product load libraries in the
STEPLIB or ISPLLIB concatenations in the TSO logon PROC. The CSS message and panel libraries must be placed before all Compuware product message and panel libraries in the
ISPMLIB and ISPPLIB concatenations in the TSO logon PROC.
Sharing CSS DDIO Files With Multiple CPUs
If you are sharing CSS DDIO files among multiple CPUs, the following qnames must be changed from LOCAL to GLOBAL enqueues.
• ABENDAID
• ABENDDAM
• ABENDSMF
• CWCATALG
Note: These qnames are needed for all products. Please refer to the individual
Compuware product documents with which CSS was distributed for other product requirements.
For IBM’s GRS (Global Resource Serialization), these qnames must be added to the inclusion RNL. This RNL is defined in the GRSRNLxx member of SYS1.PARMLIB for
MVS/XA and later. For pre-MVS/XA systems, these qnames are maintained in the
ISGSIRNL entry point of ISGGRNLO. Please consult the IBM product documentation for further details.
The CSS sample library contains an example of how qnames should be coded in the
GRSRNLxx member of SYS1.PARMLIB. See “CSS Sample Library Members” on page 2-7 for
more information.
For resource serialization packages other than GRS (for example MIM), consult the product documentation for changing LOCAL to GLOBAL enqueues.
CSS Language Processor (LP)
The language processor captures information about a compiler listing and stores it in a source listing DDIO file. The majority of this information is gathered from the compiler listing, but optionally, SYSIN and SYSLIB are also examined. The source listing DDIO file may be in standard DDIO, shared directory, or database format. Releases prior to
Xpediter/TSO 7.3, Xpediter/CICS 7.6, and Abend-AID for CICS 4.5 do not support source listing shared directories. Instead, individual source databases may be specified for lower levels.
The language processor can be run using two methods:
• pre-processor
• post-processor
You may use the pre-processor or post-processor (whichever is best for your site as needed). This section discusses the benefits of the preprocessor and the post-processor and describes when to use them.
Pre-processor
Some information about a program module is not always available from the compiler listing. The pre-processor, in addition to gathering information from the compiler listing, gathers information from SYSIN and SYSLIB. The preprocessor provides additional functionality for Xpediter/CICS and Xpediter/TSO, and is required for PL/I programs that use the %NOPRINT statement.
Preparing for ECC Installation
2-5
When setting up the language processors, Compuware recommends that you use the preprocessor instead of the post-processor. The post-processor should only be used in situations where compiled source listings have been stored.
Pre-processor Steps
1. Determines the proper compiler options required to process the listing file.
2. Automatically invokes the compiler or assembler to compile or assemble your source program.
3. Writes the listing to the DDIO file. An enhanced listing for COBOL programs can be produced, if desired. PL/I and Assembler listings are written to SYSPRINT. C listings are written to SYSCPRT.
Pre-processor Benefits
• Better handling of compiler errors. By using the preprocessor, you can avoid the potential problem of processing a listing with compiler errors. The preprocessor, in conjunction with the CONDDDIO parameter, internally checks the return code from the compiler and doesn’t write a DDIO listing that contains errors. For example, if you set the CONDDDIO parameter to 8, the preprocessor will write the compiler listing to the DDIO file unless the compiler return code exceeds 8. The preprocessor can process the compiler errors more effectively than the post-processor. Compuware recommends that you use the preprocessor rather than the post-processor.
• Capturing suppressed source code. When any of the following parameters are used, sections of source code can be suppressed from the compiler listing:
For COBOL
For PL/I
COPY SUPPRESS
%NOPRINT
For Assembler
PRINT OFF or PRINT NOGEN
For C
NOSHOWINC and NOEXPMAC
The preprocessor captures this information from SYSIN and SYSLIB, or by forcing on more revealing compiler options, then altering the listing to emulate the options you requested.
• Automated compiler options. The post-processor requires that certain compiler options be specified in order to process all needed sections of the compiler listing.
The preprocessor can automatically pass the required options to the compiler.
• Simplified JCL. While the post-processor requires that the user add a step after the compile step, the preprocessor requires only that minor modifications be made to your existing compile step.
Files Dynamically Allocated
The following files are dynamically allocated by the Compuware preprocessor. The attributes can be overridden by specifying a DD in the JCL.
Table 2-2.
Files Dynamically Allocated by the Preprocessor
DDname Attributes
CWPWRKn (0-6) BLKSIZE=19000 SPACE(TRK,(100,80)) UNIT=SYSDA
TEMPLIN BLKSIZE=3200 UNIT=SYSDA
CWPERRM SYSOUT=*
SYSPRINT SYSOUT=*
SYSOUT SYSOUT=*
CWPPRTI (PL/I) BLKSIZE=19000 SPACE(TRK,(100,200)) UNIT=SYSDA
2-6
Enterprise Common Components Installation and Customization Guide
Table 2-2.
Files Dynamically Allocated by the Preprocessor
DDname Attributes
CWPPRTI (all other languages) BLKSIZE=16093 SPACE(TRK,(100,200)) UNIT=SYSDA DISP=MOD
CWPPDS2 SPACE (TRK,(100,80,80)) UNIT=SYSDA
CWPPRTO is dynamically allocated as a work file (for the preprocessor). SYSPRINT is where the listing goes.
Post-processor
The postprocessor is executed as a single step and it can be a separate job. It reads in the listing created from the compiler. Information is gathered from the source listing, XREF, data maps, and object code sections of the listing. This information is stored in a DDIO file member and is used by various Compuware products.
While the preprocessor is the preferred method of loading the compiled listing to the
DDIO, there are situations that necessitate the use of the postprocessor as a viable alternative. This is commonly found in production environments where the listings may be archived. In order for the listings to populate the DDIO, they must be compiled using the required options specified in the appropriate language processor chapters in the
Compuware Shared Services User/Reference Guide.In order for the listings to populate the
DDIO, they must be compiled using the required options specified in the appropriate language processor chapter. Note that these are usually the default options at many shops.
If the programs contain suppressed source code, certain additional control statements must be added to the language processor. Please view the Language Processor chapters in the Compuware Shared Services User/Reference Guide for the programming language desired for more details.Please view the Language Processor chapters for the programming language desired for more details.
If the programs are compiled with OFFSET as well as OPT(imize), certain additional control statements must be added to the language processor. Please view the Language
Processor chapters in the Compuware Shared Services User/Reference Guide for the programming language desired for more details.Please view the Language Processor chapters for the programming language desired for more details.
Postprocessor Benefits
• Exact match of compiled output listings with the executable load module. This is especially important in production environments where time is critical.
• Eliminates the risk of copybook or source code changes prior to recompiling the code since the listing reflects the code that is being executed.
• Significantly less time is needed to process source listings as opposed to recompiling the source code.
Language Processor DD Statements
Table 2-6 lists the DD statements for the Assembler, COBOL, PL/I, and C language processors. Not every DD Name applies to every language processor.
Table 2-3.
Language Processor DD Statements.
DDname Purpose
CWPWRK (0-6)
CWPPRMO
LP work files
LP parameter input dataset
CWPDDIO
CWPPRTI
Target source listing DDIO file
Compiler listing input to postprocessor
Preparing for ECC Installation
2-7
Table 2-3.
Language Processor DD Statements.
DDname
CWPPRTO
Purpose
Compiler listing output from postprocessor
CWPLOAD
CWPDECK
CWPERRM
CWPWBNV
Option LOAD or OBJECT module input to postprocessor
Option DECK module input to postprocessor
LP Error Messages
Workbench navigation information
Note: CWPLOAD and CWPDECK correspond to the SYSLIN and SYSPUNCH compiler
outputs. If you specify compiler option OBJECT, you should use CWPLOAD in your postprocessor JCL. If you specify compiler option DECK, you should use
CWPDECK in your postprocessor JCL. Do not feed the SYSLIN output into
CWPDECK or the SYSPUNCH output into CWPLOAD. The updated OBJECT contained in CWPLOAD and CWPDECK should be used in the program’s linkedit step. The preprocessor does not use CWPLOAD and CWPDECK.
Writing a Listing to a DDIO File
Several options exist to place listings in a DDIO file. Each option requires that some changes be made to your JCL. The type of changes needed depend on whether you are using the preprocessor or the post-processor, and the type of debugging session. Refer to
“CSS Sample Library Members” for a list of the sample JCL that can be used for the
various options.
Testing and Debugging Programs
The actual method used for handling testing and debugging programs depends on whether you are preprocessing or postprocessing:
• Preprocessing — Run the preprocessor and link your program.
• Postprocessing — Compile your program, run the post-processor, and then link your program.
With either of these methods, the language processor places a listing in the DDIO file whenever a program is compiled.
Debugging Production Programs
If the original compiler listing is available in machine-readable format, you can retrieve the listing and use it as input to the post-processor in order to reprocess the listing and recreate it in the DDIO file. The post-processor can process listings stored by most products.
Note: If the listing you use as input to the post-processor contains any other
information (such as translator or link edit output), in addition to the compiler information, you may not obtain the desired results.
CSS Sample Library Members
The following list describes the members of the CSS sample JCL library that you may work with during installation (depending on your installation options). Use these members only as needed if directed to do so by a specific Compuware product installation guide. These members are distributed and updated via SMP/E. The members will be located in the following files after the SMP/E Apply and Accept steps are complete.
2-8
Enterprise Common Components Installation and Customization Guide
• COMPWARE.MLCXnnn.SLCXCNTL (target library)
• COMPWARE.MLCXnnn.ALCXCNTL (distribution library) where nnn indicates the CSS release number.
To print the CSS sample library members, submit the JCL contained in library member
CXPRINT after the distributed media has been unloaded.
CWASSECD
Security Exit program DSECT.
CWASSECU
Sample Security Exit program.
CWCMTRHE
Sample customized horizontal translation table for mixed-case English.
CWCMTRHT
Sample customized horizontal translation table for uppercase English.
CWCMTRHU
Sample customized horizontal translation table for mixed-case English with Euro character.
CWCMTRVE
Sample customized vertical translation table for mixed-case English.
CWCMTRVT
Sample customized vertical translation table for uppercase English.
CWCMTRVU
Sample customized vertical translation table for mixed-case English with Euro character.
Note: The following five members are specific for Abend-AID. They
allow browse access to diagnostic reports and source listings directly through ROSCOE or print access via a job submitted from ROSCOE to run in batch. Refer to the members for additional information.
CWROSBAT
ROSCOE sample members.
CWROSBRW
ROSCOE sample members.
CWROSCOE
ROSCOE sample members.
CWROSDIR
ROSCOE sample members.
CWROSPDF
ROSCOE sample members.
CWUTCLSE
Sample CLIST to invoke CSS online utilities with English messages and panels.
CWUTCLSJ
Sample CLIST to invoke CSS online utilities with Japanese messages and panels.
CWUTREXE
Sample REXX EXEC to invoke CSS online utilities with English messages and panels.
CWUTREXJ
Sample REXX EXEC to invoke CSS online utilities with Japanese messages and panels.
CWVFCLPT
CLIST to invoke the language processor debugging aid.
CWVFRXPT
Note: The debugging aid is a diagnostic tool to be used only under the
supervision of Compuware Customer Support in the event of a problem related to the language processor.
Sample REXX EXEC to invoke the Compuware language processor debugging aid.
Preparing for ECC Installation
2-9
Note: The debugging aid is a diagnostic tool to be used only under the
supervision of Compuware Customer Support.
Abend-AID CWAASDUT DIRX sample JCL.
CXAADIRX
CXAAEXPO
CXAAIMPO
Abend-AID CWAASDUT EXPORT command sample JCL.
Abend-AID CWAASDUT IMPORT command sample JCL.
CXAAMOVE
Abend-AID CWAASDUT MOVE command sample JCL
CXALLBAA
JCL for creating sequential Abend-AID database files.
CXALLBLP
CXALLBSD
CXALLDAA
CXALLDLP
JCL for creating sequential source listing database files.
JCL for creating Abend-AID for CICS sequential transaction databases.
JCL for creating Abend-AID shared directories.
JCL for creating Source Listing Shared Directories.
CXALLDS
CXALLMC
CXALLVAA
CXALLVLP
CXALLVS
CXALLVSD
CXASM
CXASMPRE
CXC
CXCAPTUR
CXCFGEXT
JCL to allocate a sequential DDIO file.
JCL for creating Abend-AID for CICS shared directories.
JCL for creating VSAM Abend-AID database files.
JCL for creating VSAM Source Listing Database files.
JCL to allocate a standard VSAM Abend-AID report or source listing
DDIO file.
JCL for creating Abend-AID for CICS VSAM transaction databases.
JCL for running the Assembler language post-processor.
JCL for running the Assembler language preprocessor.
Sample JCL for running the C post-processor.
Sample JCL for creating a tape from the output of the CSS Problem
Documentation Utility.
Sample JCL to extract a source file from the configuration module in a
CSS load library.
CXCFGINI
CXCFGSET
CXCIREG
CXCIVSAM
CXCOBPRE
CXCOB1
CXCOB2
Sample source configuration file.
Sample JCL to build a configuration module in a CSS load library, from a source configuration file you create.
Sample JCL to register the Contact Information dataset.
Sample JCL to create the Contact Information dataset.
JCL for running the COBOL language preprocessor.
JCL for the step to be added after the compile step in your current
COBOL compile and link edit JCL. This is used in order to process the compiler listing through the Compuware language post-processor.
JCL to process COBOL compiler listings stored in machine-readable format.
2-10
Enterprise Common Components Installation and Customization Guide
CXCOB99
Sample JCL for running the COBOL post-processor.
CXCPRE
CXC2
Sample JCL for running the C preprocessor.
Sample JCL to postprocess C compiler listings stored in machinereadable format.
CXDCRADB
JCL to allocate and CREATE a multivolume Abend-AID report database.
CXDCRASD
JCL to allocate and CREATE an Abend-AID shared directory and a multivolume report database.
CXDCRLDB
JCL to allocate and CREATE a multi-volume source listing database.
CXDCRLSD
JCL to allocate and CREATE a source shared directory and a multivolume Source Listing database.
CXDCRTDB
JCL to allocate and CREATE a multi-volume transaction database.
CXDCRTSD
CXDDSUTL
Sample JCL for running the CWDDSUTL batch file utility.
CXDDUNLP
Sample JCL to execute the CWDDUNLP source extraction utility.
CXDFMAA
JCL to allocate and CREATE an Abend-AID for CICS shared directory and a multi-volume transaction database.
CXDFMSL
JCL to allocate and FORMAT a standard multi-volume Abend-AID report
DDIO file.
JCL to allocate and FORMAT a standard multi-volume source listing
DDIO file.
CXEXPORT
CXFLAG
CXFMTAA
CXFMTSL
Sample JCL for running the CWDDSUTL EXPORT command.
Sample JCL for the CWDDSUTL utility FLAG command.
Sample JCL and CWDDSUTL control statement for formatting Abend-
AID report files.
Sample JCL and CWDDSUTL control statement for formatting a source listing file.
CXCFDIRX
CXCFEXPO
CXCFEXTL
Abend-AID for CICS CWFXSDUT DIRX sample JCL.
Abend-AID for CICS CWFXSDUT EXPORT command sample JCL.
Sample JCL to export a Abend-AID for CICS transaction and a source listing to a single tape.
CXCFIMPO
Abend-AID for CICS CWFXSDUT IMPORT command sample JCL.
CXCFMOVE
Abend-AID for CICS CWFXSDUT MOVE command sample JCL.
CXIMPORT
CXJCLSEC
Sample JCL for running the CWDDSUTL IMPORT command.
JCL to assemble and link edit the Security Exit program.
CXJCLTRT
CXLPASM
CXLPC
JCL to assemble and link edit the custom translation tables.
Sample Assembler language processor options.
Sample C language processor options.
Preparing for ECC Installation
2-11
CXLPCOBB
CXLPCOBC
CXLPDIRX
Sample COBOL language processor options (batch programs).
Sample COBOL language processor options (CICS programs).
LP source CWDDLPUT DIRX sample JCL.
CXLPEXPO
CXLPIMPO
LP source CWDDLPUT EXPORT command sample JCL.
LP source CWDDLPUT IMPORT command sample JCL.
CXLPMOVE
LP source CWDDLPUT MOVE command sample JCL.
CXLPPLI
Sample PL/I language processor options.
CXLPTFS
CXLZAPS
Sample JCL to run SMPE LIST on CSS Target/Distribution zones.
Sample JCL to list the PTFs and APARs on a CSS load library
CXMODMAP
Sample JCL member to map the CSECTs in a load module.
CXOTFPRE
Sample CLIST stub for preprocessing exit for OTF
CXOTFPST
CXPDDSU
CXPLI
CXPLIPRE
CXPLI2
Sample CLIST stub for postprocessing exit for OTF
Sample JCL to print a listing or report from a DDIO file.
JCL for running the PL/I language post-processor.
JCL for running the PL/I language preprocessor.
JCL to postprocess PL/I compiler listings stored in machine-readable format.
CXPRCTL
CXPRINT
CXRELS
CXR00003
CXSPRE01
CXSPST01
CXTUTOR
CXUECEXT
CXUECIN2
DDIODAYS
DDIODAYJ
FDXTRN01
GRSRNLXX
P@CPRE01
IEBPTPCH control statements for job CXPRINT.
JCL to print the entire CSS installation library.
PTF/APAR tracking module. Do not modify this member.
Sample Tutorial main menu.
Sample Skeleton for on-the-fly preprocessing.
Sample Skeleton for on-the-fly postprocessing.
Alternate Sample Tutorial main panel.
Sample CLIST for the Compile Facility JOB card exit
REXX EXEC used to invoke the Compile Information installation screens
REXX utility to delete DDIO file members by age.
Sample JCL for running the DDIODAYS REXX utility. This utility deletes
DDIO file members by age.
File-AID DB2 Interface CLIST.
Sample GRS qname inclusion RNL.
Sample panel for preprocessing exit for on the fly.
2-12
Enterprise Common Components Installation and Customization Guide
P@CPST01
P@HPRE01
P@HPST01
ATSOECLP
CSPFINIT
CSSTPCFG
CXCFGBLD
CXTPDEF
CXTP01
HCICFG
HCIJCL
HCIJOURN
HCILOAD
HCIPARM
Sample panel for postprocessing exit for on the fly.
Sample Help panel for preprocessing exit for on-the-fly processing.
Sample Help panel for postprocessing exit for on-the-fly processing.
Sample TSO logon procedure for Xpediter/TSO via Compuware
Workbench.
Sample JCL to create and initialize the Compuware Shared Profile dataset.
Sample Compuware Workbench TP configuration file member.
Sample JCL to create the Compuware Workbench configuration file dataset.
Sample HCI configuration parameters to be inserted into an existing
HCI configuration.
Sample HCI PARMLIB member for the Compuware Workbench TP.
Sample JCL and macros that define a total HCI configuration for the
Compuware Workbench TP (use with a newly installed or copied HCI).
Sample HCI start-up JCL.
Sample JCL to create the HCI journals.
Sample JCL to create the HCI configuration load library.
Sample JCL to create the HCI PARMLIB library and member.
LMS Installation Considerations
This section describes considerations for installing and customizing LMS.
APF Authorization
Following IBM system integrity guidelines, Compuware requires that your LMS load library be APF-authorized. You must provide an APF-authorized load library into which you place the modules for LMSINIT since all load modules for LMSINIT must reside in an
APF-authorized load library.
Execution Sequence
In order to ensure availability of Compuware products with LMS-controlled access, the
LMS runtime environment must be established before any of those products are initialized. For this reason, Compuware strongly recommends that you institute an MVS start-up procedure based on the sample proc provided. It should run automatically as part of IPL and IML processing prior to any procs utilized by other Compuware products.
It may be necessary to consult your site’s MVS system programmer.
The License Management System Functions
The License Management System has three basic functions.
Preparing for ECC Installation
2-13
License Management Administration
You will create and maintain your License File using the License Administration Utility
(LAU) installed with your License Management Software. Your License File is used as the source from which Compuware products will validate access for your site. When you receive License Certificates for Compuware products, your organization’s License
Administrator must use the LAU to import the License Certificates into the License File.
Additional features of the LAU assist in the maintenance of your License Files. In addition to browsing the License Certificates in your License File, you may run a number of administrative reports from the LAU. These reports will reveal the contents of your
License File, from a number of perspectives, allowing you to determine the state of the
License Certificate for any particular Compuware product release.
Depending on the requirements of your organization, you may have more than one
License File. Each License File can be centrally administered from the License
Administration Utility.
In addition to using the LAU to administer licenses in individual license files, an optional feature called the Centralized Licensing Facility (CLF) can be used to manage your licensing environment from a single z/OS system regardless of where your production or test LPARs reside. Please see the License Management System User/Reference Guide—Centralized
Licensing Facility for more information about CLF.
Establishing the Runtime LMS Environment
You will use the License Files created and maintained by the License Administration
Utility as input to a program that establishes your Compuware LMS runtime environment. This program is named LMSINIT. LMSINIT is the License Management
System program that reads the License File
1
and constructs the License Cache and
License Management System subsystem against which Compuware product runtime license access requests are later made.
Important: You must re-establish your runtime License Management System environment at each IPL, and whenever you have an update to your License File, the update must be made available to your z/OS systems. At IPL startup, LMSINIT must be completed before starting up any Compuware product.
Validating Product Access Requests During Product Use
Your access to your Compuware products will be validated when you use your
Compuware products. The Compuware product will make a request of the License
Management System to determine if your site has a valid License Certificate for the product release. The requests are made by the product at various times during its execution depending on the product’s needs. The Compuware product will access the
LMS subsystem established, request License File information and act upon the information. If the License Certificate information is valid, users will proceed with their use of the product without disruption. Any abnormal License Management event detected will be reported to the product’s user and may optionally be reported by e-mail to your organization’s License Administrator. The disposition and frequency of the reporting of these events can be controlled by the customer using the "Message
Suppression and Distribution" feature of LMS. See the License Management System
User/Reference Guide—Centralized Licensing Facility for more information about this feature.
Optionally, these events may also be recorded in SMF Logging.
Note: LMSINIT can read more than one License File if you are an organization that
administers Compuware product access for more than one Compuware customer.
1. LMSINIT can read more than one License File if you are an organization that administers Compuware product access for more than one Compuware customer.
2-14
Enterprise Common Components Installation and Customization Guide
HCI Installation Considerations
This section describes considerations for installing the Host Communications Interface which is a requirement for several Compuware products.
APF Authorization
The HCI component library (COMPWARE.MLHCnnn.SLHCAUTH) must be APFauthorized. This library is used in the HCI regions that serve various Compuware
products. See Table 2-1 on page 2-1 for the specific products.
Security Settings
HCI can switch ACID (UserID) while processing certain requests. Some security package settings may then prevent the HCI from writing to JES sysout after this is done.
Installation with such strict security settings need to allow the HCI task access to the
JESSPOOL class.
Installations that have such settings that limit any or all user access to output from other users can do so by setting the appropriate profiles for the security class JESSPOOL.
Profiles for JESSPOOL are in the format:
Local-nodename.userid.jobname.jobid.dsnumber.name
Using combinations of userIDs and wildcard characters, output viewing can be limited on a userid or groupid basis as the installation chooses.
Please consult your installation's appropriate security software administration documentation for additional information. For RACF installations, controlling access to output via the JESSPOOL class is documented in IBM’s z/OS Security Server RACF Security
Administrator's Guide, section entitled, “Controlling Access to Spool Data”.
Atsisiųsti
Reklama