- No category
advertisement
1-5 Standard Specifications
Scanning : Convex and linear electronic scanning
Display mode : B-, B/M-, M-Mode
Beam focus : Real-time continuous dynamic focus on receive. Selectable and combination focus on transmit
Scale : 4 depth selections
Display Monitor : 12 inch monochrome
Dynamic range : 30 - 72dB (6dB steps)
Gain : 0 - 99dB (1dB steps)
TGC : 8 slide pots (at fixed depths)
Post process : Gray Scale Mapping selections
Vertical Scroll : Micro-convex probe/linear probe (Mode dependent)
Memory : 32 frame, continuous loop Cine memory (optional)
Measurements : Distance: 4 results simultaneously
Circumference: 4 results simultaneously by 3 methods
Area: 4 results simultaneously
Calculation : Circumference, velocity, volume, ratio, etc.
OB Calc Package
Gestation table : 2 Tables. 5 selections per table (5 factory stored and 5 user programmable)
Biopsy guidelines : Varies with probe type.
Image direction : Invert/Reverse RT 3200 Advantage - I display
Body markers : Abdomen, OB/GYN, Neck and Head
Text display : Alphanumeric keyboard
Automatic display : Clock, scan parameters & probe type.
Weight (lb) : Approx. 182 lb
Tall version approx. 189 lb
Temperature/Humidity
Requirements : Operating: 50
°
-99.9
°
F (10
°
-40
°
C) at 30-75% Relative Humidity (RH)
Heat Dissipation: 650/BTU per hour (1 person = 300 BTU per hour)
Storage: 32
°
-122
°
F (0
°
-50
°
C) at 10-85% RH
Transport: 32
°
-122
°
F (0
°
-50
°
C) at 5-80% RH
Electrical Requirements : Line: Domestic (115V)—for unit as shipped, 115V~, 48-63 Hz, singlephase, fused at T2 amps.
Line: International (220/240V)—for unit as shipped, 220/240V~, 48-63
Hz, single-phase, fused at T2 amps.
Allowable Line Noise: Decaying oscillation transients of less than 15% nominal peak voltage; voltage transients of less than 25% nominal peak voltage.
System Leakage Current: Enclosure or chassis—less than 100 microamps.
Ordinary Patient Connections—less than 50 microamps.
46-030370 1 INTRODUCTION 1-5
advertisement
Related manuals
advertisement
Table of contents
- 21 Overview
- 21 Features
- 22 Standard Configuration
- 22 Available Options
- 23 Standard Specifications
- 24 Dimensions
- 26 Hardware Description
- 28 Display Formats
- 30 System Set-up
- 39 Description of Front Panel
- 45 Entering Patient Information
- 45 Selecting a Probe
- 46 Scan Image Adjustment
- 57 Measurement Keys
- 58 Function Keys
- 58 Single Keystroke Operation
- 61 Overview
- 62 Distance Measurement
- 64 Circumference Measurement
- 66 Area Measurement
- 68 Measurement Calculation Error Messages
- 71 Control Function Key
- 72 B-Mode Presetting
- 73 Clock Readjustment
- 75 Text/Graphics Display On/Off
- 76 Echo Level
- 80 Histogram
- 83 Film Development Time
- 84 Gestational Data
- 88 Hospital Name
- 89 Inverse
- 90 Body Pattern Package
- 92 High Frame Rate On/Off
- 93 Biopsy Guideline
- 101 Map Package
- 101 Dotted Line On/Off
- 102 Record Output (Gamma Curve Selection)
- 103 Frame Averaging On/Off
- 107 Function Keys
- 108 OB Table 1
- 119 OB Table 2
- 126 Calc 1
- 143 Calc 2
- 161 Mapping
- 169 Overview
- 169 Basic Urology Measurements
- 169 7.0 MHz Transaxial Probe
- 179 Mechanical Stepper/Needle Placement Guide
- 189 Stepper Volume Calculation
- 205 Overview
- 205 Accessory Panels
- 208 Connecting a Sony Page Printer
- 212 Connecting a Pansonic VCR
- 216 Connecting a Multi-Image Camera
- 221 A: Control Parameters
- 227 B: Acoustic Level Notes
- 229 C: Cleaning and Inspecting
- 237 D: Troubleshooting
- 239 E: Maintenance
- 245 Overview
- 246 Ellipse Measurement Function
- 248 HIP Dysplasia Calculation
- 251 Estimated Fetal Body Weight—Third Calculation
- 252 Gestational Summary Report Page
- 267 Report Page Sequencing
- 268 Measurement Averaging Page
- 270 Anatomical Survey Report Page
- 272 User Programmable Comments Library
- 276 Urology Summary Report Page
- 278 Record Output—Line Printer
- 279 Prostate Body Marker Patterns
- 280 Calc 3
- 281 Cine Memory Operation