Appendix. U.S. Solid USS-DBS USSDBS13, USS-DBS USSDBS11, USS-DBS USSDBS12, USS-DBS USSDBS9, USS-DBS USSDBS10, USS-DBS USSDBS7, USS-DBS USSDBS8, USS-DBS USSDBS5, USS-DBS USSDBS6, USS-DBS USSDBS4
Below you will find brief information for Digital Analytical Balance Scale USS-DBS USSDBS4, Digital Analytical Balance Scale USS-DBS USSDBS5, Digital Analytical Balance Scale USS-DBS USSDBS6, Digital Analytical Balance Scale USS-DBS USSDBS7, Digital Analytical Balance Scale USS-DBS USSDBS8. The USS-DBS series adopts high precision electromagnetic force balance sensor, which makes the scales capable of fast and accurate weighing function and better reliability. It comes with multiple operation keys, which make it easier to use the scales. Please read this instruction manual carefully and use the balance scale correctly.
Advertisement
Advertisement
Advertisement
Key features
High precision electromagnetic force balance sensor
Fast and accurate weighing function
Multiple operation keys
Calibration function
Tare function
Counting function
RS-232C interface
Windshield
Adjustable feet
Level meter
Frequently asked questions
Press the "CAL" button, place the calibration weight on the pan, and wait until the flashing weight value display changes to "200.0000g". Then remove the weight and the scale will return to weighing mode.
Place the container on the pan, the weight of the container will be displayed. Press the "TAR" button, the display will go out and the display will be all zeroes. Taring is completed. When the container is removed, a negative value of the container weight will be displayed. Press "TAR" again, the display will be all zeroes, i.e. the balance clears.
The scale should be placed on a steady, fixed table. The table should be put at a place with less vibration. The scale should be put far away from sunlight and radiation. Avoid extremes of temperature.
Press "start"--- -Process----Attachment ----Communication----Super terminal. Input the name; choose the icon, then press confirmation. Ignore the first two steps,, choose "N": com 1", press confirmation. Choose: Baud rate: 1200 (or 2400 according to the manual); Data bit: 8; Check out of odd and even: No; Stop bit: 1; Control of the data flow: hardware. Press confirmation and it will show the measuring value on the computer.
Before cleaning, pull out the power supply. Don't use caustic cleanser (such as solvent). Add some neutral detergent to a gentle cloth to clean the scale. Don't drop the water into the scale. Dry the scale after cleaning.