RGN 120-260 Manual

Add to My manuals
29 Pages

advertisement

RGN 120-260 Manual | Manualzz

Installation

Installation

Installation positions for KE...D,Z

90°

Installation position for KE...V

Installing flange and burner

When installing the sliding flange, only tighten screws

1 and 2 otherwise it will not be possible to secure the burner pipe with screw 3. Slide in the burner, adjust to furnace depth and tighten the screws in the following sequence: 3, 4, 5, raising the housing in the process.

Important: Secure the sliding flange so that the clamping screw 3 is positioned at the top.

Checking electrode setting

• Move the burner into the service position as described on Page 23.

• Check the setting of the ignition and ionisation electrodes (see Page 23).

90°

Installing gas assembly

• Remove plastic protective plug.

• Install unions including accompanying seals.

• Observe installation position.

• Check connecting point of gas assembly with noncorrosive foaming agent for leaks and vent gas pipe.

• When venting gas, discharge safely to atmosphere with a hose.

Comply with DVGW-TRGI 1986/96 Section 7,

TRF 1988, DIN 4756 and local regulations.

If proportional pressure control RGN(L)120/260T, with KEV:

Fit the furnace pressure meter tube to the boiler door with the gradient towards the boiler (if required).

Lay the control lines to the KEV to the corresponding ports P

L

and P

F

.

Use the blue PU hoses supplied.

• Lay the control line so that no condensate can flow into the KE.

• Connect hose to furnace pressure meter tube with port P

F

(if required).

• Connect hose to port P

L

with measuring nipple for air pressure on burner base plate.

If this connection is not made, the magnetic valves will not open.

5

advertisement

Related manuals