34 Intellex ® Operating Instructions
Playback
Controls and Indicators
4.
Image Database —
This progress bar indicates how much recording space in the image database has been used and how much is available.
5.
Record —
This indicator is lit when the unit is recording images. On the front panel, this indicator is labeled REC.
6.
Play —
This indicator is lit when the unit is playing back images. Play changes to Pause when playback is paused.
When playing back images restored from an archive tape, the unit displays Play (Archive) or Pause (Archive).
7.
Playback Overlay —
Displays the name of the displayed camera, the image date and time and the alarm input or type of alarm event (if any).
Use the mouse pointer and the following on-screen controls to play back images:
8.
1–16 (Cameras) —
Click to play back images for specific cameras. The light indicates which camera is being played back. The message No Video appears on the screen if no images have been recorded for the selected camera.
9.
Alarms Indicator —
This light indicates that alarm events have occurred, but have not been reviewed. It also blinks if a notification screen appears.
10. Play/Pause
knob — Controls the playback speed and direction (see Using the Playback Screen). The unit displays the playback speed (1x to 5x) and direction (forward or reverse).
11. Alarms —
Click to display the alarm review screen.
Chapter 3 — Playback Operation 35
12. Play/Pause
button — Click to play back images or to pause image playback.
13. Screen Formats —
Click to change the live display format. If in playback mode, the unit changes the live display format, but does not exit playback. If an optional live monitor is installed, the new format appears immediately.
14. Status —
Click to display the status screen (see Review-
ing Unit Status).
15. Seq (Sequence) —
Click to display cameras sequentially
(see Camera Sequencing). If in playback mode, the unit changes the format on the live display, but does not exit playback. If an optional live monitor is installed, camera sequencing appears immediately.
16. Full Scrn —
Click to hide the playback controls and indicators and to display the image area full-screen. Click the screen to display the playback controls and indicators again and to display the image area at its normal size (see
Full-Screen Operation).
17. Search —
Click to search the image database for specific images (see Image Database Search).
18. Close —
Click to close this screen and return to the main screen.
19. Tools —
Click to enhance the currently displayed image using the image enhancement tools (see Image Enhancement
Tools). You can also print the image or save it to a diskette.
20. GoTo —
Click to select any starting point in a video segment by moving the slider control. The Begin Date and
End Date and Begin Time and End Time of the selected segment is displayed in the GoTo screen. As you move the slider, the Select Date and Time at the slider’s location in the segment is displayed in the GoTo screen. Move the slider to any desired point in the segment, then click Play to begin or resume playback of the segment at that point.
21. Help —
Click to display help information.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 12 SAMPLE CONFIGURATION
- 13 SAMPLE NETWORK CONFIGURATION
- 14 INTELLEX FEATURES
- 16 TECHNICAL OVERVIEW
- 16 Digital Picture Processing
- 16 Sensitivity Settings
- 16 Image Quality Settings
- 17 Video Input and Output
- 17 Main (SVGA) Monitor
- 17 Optional Live Monitor
- 17 Optional Live Remote
- 17 Optional Call Monitor
- 18 IntelleCord Filters
- 18 Smart Search Filters
- 18 Filter Descriptions
- 18 Motion Detection
- 18 Perimeter Protection (Perimeter Violation)
- 18 Playback
- 18 Light Change
- 19 Unit Configuration
- 19 WAN Support
- 19 Pre-Alarm Playback
- 19 Data Lifetime
- 19 Security
- 19 Schedule
- 20 Regular Schedule
- 20 Custom Schedule
- 20 Single Camera
- 20 Archiving
- 20 Backup
- 20 Restore
- 20 Playback
- 21 Archive Schedule
- 21 Alarm Processing
- 22 INTRODUCTION
- 23 STARTING THE INTELLEX UNIT
- 24 AND KEYBOARD
- 24 Mouse Operation
- 24 Front Panel Operation
- 24 Keyboard Operation
- 25 Virtual Keyboard
- 25 Physical Keyboard (Optional)
- 25 Selecting or Activating Features
- 25 Getting Help
- 26 SECURITY CONSIDERATIONS
- 27 LOGGING IN AND CHANGING USERS
- 27 Logging In
- 28 Changing Users
- 29 INTELLEX MAIN SCREEN
- 30 On-screen Controls and Indicators
- 32 CONTROLLING IMAGE DISPLAY
- 32 Screen Format
- 33 Image Area Popup Menu
- 33 Switch to Full Screen
- 33 Single Pane
- 34 Generate Alarm
- 34 Camera
- 35 Cancel
- 35 Switch to Menu
- 35 Image Area Zoom
- 36 Full-Screen Operation
- 37 Camera Sequencing
- 38 Live Monitor (Optional)
- 38 Dome Controller (Optional)
- 38 Unit Schedule
- 39 REVIEWING UNIT STATUS
- 42 SHUTTING DOWN THE UNIT
- 44 PLAYBACK SCREEN
- 45 Playback Controls and Indicators
- 47 Using the Playback Screen
- 47 Using Play/Pause
- 49 Switching Cameras
- 49 Image Area Zoom
- 49 Full-Screen Operation
- 50 Using Other Controls
- 51 IMAGE DATABASE SEARCH
- 52 Searching without Filters
- 53 Date/Time Search
- 57 Camera Search
- 59 Alarm Search
- 62 Searching with Filters
- 63 Date/Time Search
- 66 Filters Search
- 70 Search Filter Configuration
- 70 Light Change
- 73 Motion Detection
- 76 Perimeter Violation
- 79 Working with Search Results
- 79 Sorting the Search Results
- 80 Selecting a Segment to Review
- 81 IMAGE ENHANCEMENT TOOLS
- 87 Brightness/Contrast Tools
- 87 Modifying the Image
- 88 Color/Light Tools
- 89 Balance Light
- 89 Edge Detect
- 89 Enhance Light
- 90 Noise Reduction
- 90 Sharpen
- 91 Sharpen More
- 91 Smooth More
- 91 Smooth
- 93 ALARM OPERATION
- 93 Mechanical Alarms
- 95 Live Filter Events
- 96 Video Loss Alarms
- 98 Generated Alarms
- 99 Alarm Groups
- 101 ALARM REVIEW SCREEN
- 103 Selecting a Segment to Review
- 104 ARCHIVE OPERATION
- 105 Back Up the Image Database
- 107 Background Archiving
- 111 Interrupting Background Archiving
- 113 Foreground Archiving
- 117 Recovering from an Interruption
- 119 Restore Images
- 123 Play Restored Images
- 124 Format Tape
- 125 Recover Data from Tape
- 127 UTILITY OPTIONS
- 128 Begin Record
- 130 Generate Alarms
- 132 Clear Latched
- 132 Log Out
- 133 Shutdown
- 134 Exit to System
- 135 About Intellex
- 136 LINEAR MODE OPERATION
- 137 Database Partially Full
- 138 Database 90% Full
- 139 Database Full
- 140 Unarchived Images
- 141 Archived Images
- 142 INDEX