SerTest- RS232 Interface Test Program

This software allows a user to test the functions of an NTI server switch, matrix switch or Multi-user/Multi-platform switch RS232 interface. The SerTest program is automatically loaded when installing the Matrix Switcher ’ s Control Program as described above. The SerTest program, located in the NTI program group, generates a main menu with the 4 selections described below:

Main Options

Matrix Operations

Ethernet Operations

Setup Options

About SerTest

- send commands to the matrix unit.

- set Ethernet connection variables

- set COM port, baud rate, and unit address

- display the program version

Matrix Operations

Key Selection

1) Connect Video Output/User to an Input/CPU

2)

3)

4)

Connect All Video Outputs/Users to an Input/CPU

Connect Audio Output/User to an Input/CPU

Connect All Audio Outputs/Users to an Input

Description

- connect an output to an input

- connect all outputs to an input

- connect an output to an input (audio ports only)

- connect all outputs to an input (audio ports only)

5)

6)

7)

8)

9)

Change Mute Status for Audio Output/User

Change Volume for Audio Output/User

Read Connection for Video Output/User

Read Connection for Audio Output/User

Read Mute and Volume for Audio Output/User

- mute or un-mute the Audio port output

- change Audio port output volume

-read the connection of a specific video output

-read the connection of a specific audio output

- read the volume and the mute status of the specified output

(audio ports only)

-save the connections into switch memory bank

-restore the connections from switch memory bank a) b) c) e) f) g) h)

Save I/O Connections into Unit Memory

Restore I/O Connections from Unit Memory

Change All Units Baud Rate (9600/COM1:) d) i)

Reset Unit

Reset All Units

Read Unit Size

Read Unit Version/Revision String

Save All Units I/O Connections into Units Memory

- read the switch size (number of inputs and outputs)

-read a string containing the switch version, type, and size

-save the connections into switch memory bank, command for all switches

Restore All Units I/O Connections from Units Memory -restore the connections from switch memory bank, command for all switches

Grayed keys are for models with audio support

-change RS-232 Baud rate of all switches

-the current baud rate and serial port are displayed in parentheses

- send a reset command to the switch

- the current unit address is displayed in parentheses

- send an internal reset command to all switches

Ethernet Operations

5)

6)

7)

8)

Key Selection

1)

2)

3)

4)

Set Unit IP Address

Description

- enter the desired IP address in xxx.xxx.xxx.xxx format

- number of digits is minimum 1 and maximum 3 for each field. Leading zeroes are accepted

Set Unit Subnet Mask

Set Unit Default Gateway

Set Unit Website Timeout

Read Unit IP Address

Read Unit Subnet Mask

- enter the desired IP address in xxx.xxx.xxx.xxx format

- number of digits is minimum 1 and maximum 3 for each field. Leading zeroes are accepted

- enter the desired default gateway

- number of digits is minimum 1 and maximum 3 for each field. Leading zeroes are accepted

- set the website timeout; timeout = numeric string of timeout in seconds

- Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800 0 = no timeout

- read the unit IP address in xxx.xxx.xxx.xxx format

- read the unit subnet mask in xxx.xxx.xxx.xxx format

Read Unit Default Gateway - read the unit default gateway in xxx.xxx.xxx.xxx format

Read Unit Website Timeout - read the current website timeout period in seconds

- Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800 0 = no timeout