Fault monitoring relay connector. AWG DUAL USB POWER CHARGER FOR NDS LITE
Add to my manuals
24 Pages
advertisement
AXYS ® Intellivox 808/1608 Installation Manual Rev 1.1
FAUlT MoNITorING rElAY CoNNECTor
or
5 4 3 2 1 1 2 3 4 5 fig.10.1 - Fault monitoring relay connections
PIN No.
1
2
3
4
5 lABEllED
COM
NO
NC
+24V
-
USE
Failure relay Common
Failure relay Normally Open
Failure relay Normally Closed
+24V
Not connected
The pinout of this connector is as follows:
Fault Monitoring
The IntelliAmp’s internal Failure Relay is energised in normal operation (COM connected to NC). Power failure or a pre-defined fault condition causes the relay to release, when COM will be shorted to NO. External fault monitoring equipment can be connected to COM and either NO or NC as required, depending on whether the external system registers a fault condition as a short-circuit or an opencircuit. The relay contacts are fully floating (volt-free).
The fault conditions under which the IntelliAmp failure relay is de-energised are user-definable, and are loaded as part of the unit’s settings file with WinControl.
Status lED
Note that the front panel Status LED mimics the operation of the failure relay. The LED is green in normal operation, and goes red when a fault condition arises.
To external fault reporting system
(OR)
–
+ 24 V
FAULT NC
FAULT NO
FAULT COM
IntelliAmp
24 V DC
Not connected
Failure
Relay fig.10.2 Failure relay connections
The diagram above illustrates how this connector may typically be wired.
The external fan control is not operational, the IntelliAmp is equipped with internal temperature-controlled fans.
Please note that Failure Relay and SPL/Temp sensor connectors are both of the same type, do NOT interchange!
201112/IvxHPIM_v1.1
13
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 2 Reference to Statements of Conformity
- 2 User’s Notice and disclaimer
- 4 1. Important Safety Instructions
- 5 2. Introduction
- 5 Applicable models and variants
- 6 What’s in the packaging
- 7 3. Installation Guide
- 7 Preparing for Installation
- 7 Signal and Control cables
- 8 Mechanical Installation of the Amplifier
- 9 Connector and wiring details
- 9 AC Mains
- 10 WAGO connectors
- 11 Audio inputs
- 12 Network connection
- 13 Fault monitoring relay connector
- 14 External Ambient SPL/Temperature Sensor
- 15 Loudspeaker connections
- 15 Cable Specifications
- 16 Mechanical Installation of the Loudspeaker
- 18 - Mounting Procedure
- 19 4. System checks
- 19 Connecting the PC to the IntelliAmp
- 20 Settings file upload
- 22 5. Appendix
- 22 Optional accessories
- 23 Common analogue grounding issues
- 23 Software and firmware updates
- 23 Network cables