OPERATION
Register your product
!
DANGER:
WATER TEMPERATURES OVER 125 °F (52 °C)
CAN CAUSE SEVERE BURNS INSTANTLY OR
DEATH FROM SCALDING. A HOT WATER SCALD-
ING POTENTIAL EXISTS IF THE THERMOSTAT ON
THE UNIT IS SET TOO HIGH. HOUSEHOLDS WITH
SMALL CHILDREN, DISABLED OR ELDERLY PER-
SONS MAY REQUIRE THAT THE THERMOSTAT BE
SET AT 120 °F (49 °C) OR LOWER TO PREVENT
POSSIBLE INJURY FROM HOT WATER.
!
WARNING:
THIS WATER HEATER MUST BE INSTALLED
STRICTLY IN ACCORDANCE WITH THE INSTRUC-
TIONS ENCLOSED AND LOCAL ELECTRIC AND
BUILDING CODES. IT IS ALSO POSSIBLE THAT
CONNECTIONS TO THE WATER HEATER ITSELF
MAY DEVELOP LEAKS. IT IS THEREFORE IMPER-
ATIVE THAT THE WATER HEATER BE INSTALLED
SO THAT ANY WATER IS DIRECTED TO AN AD-
EQUATE DRAIN IN SUCH A WAY THAT WATER
DAMAGE TO THE BUILDING, FURNITURE,
CARPETING OR OTHER PROPERTY CANNOT
OCCUR. NEITHER THE MANUFACTURER NOR
THE DISTRIBUTOR CAN BE HELD RESPONSIBLE
FOR DAMAGE CAUSED BY WATER FROM THE
WATER HEATER, TEMPERATURE PRESSURE
RELIEF VALVE, OR RELATED FITTINGS WHERE
ADEQUATE PROVISION TO DRAIN SUCH WATER
HAS NOT BEEN PROVIDED.
!
CAUTION:
HYDROGEN GAS CAN BE PRODUCED IN A HOT
WATER SYSTEM SERVED BY THIS HEATER THAT
HAS NOT BEEN USED FOR A LONG PERIOD OF
TIME (GENERALLY 2 WEEKS OR MORE). HYDRO-
GEN GAS IS EXTREMELY FLAMMABLE.
TO REDUCE THE RISK OF INJURY UNDER THESE
CONDITIONS, IT IS RECOMMENDED THAT THE
HOT WATER FAUCET BE OPENED FOR SEVERAL
MINUTES AT THE KITCHEN SINK BEFORE USING
ANY ELECTRICAL APPLIANCE CONNECTED TO
THE HOT WATER SYSTEM.
WHEN HYDROGEN IS PRESENT, THERE WILL
PROBABLY BE AN UNUSUAL SOUND SUCH AS
AIR ESCAPING THROUGH THE PIPE AS THE
WATER BEGINS TO FLOW. THERE SHOULD BE
NO SMOKING OR OPEN FLAME NEAR THE FAU-
CET AT THE TIME IT IS OPEN.
3. Register your product
NOTE:
You must register this product within 90 days of purchase on our web site in order to activate any standard warranty or to be eligible for the extended warranty. Go to our website at: www.stiebel-eltron-usa.com and click on
“Register Your Product.”
Before beginning the registration process, we suggest that you gather the necessary information as follows:
Model, Example: SHC 2.5 (from the label that is on the top of the unit in the center)
Number listed after “Nr.”
Place of Purchase
Purchase Date
First & Last Name
Email address
Physical Address
Phone Number
If you have any questions concerning the registration process or warranty options, please contact Stiebel
Eltron USA directly at (800)-582-8423.
4. General Description
These SHC water heaters can be used in most pointof-use applications. They are designed to supply hot water for hand wash and kitchen sinks in a residential, commercial or industrial environment.
These water heaters can replace traditional hot water systems which consist of a central hot water heater with hot water piping going to several draw-off points.
The SHC water heaters are lightweight and compact and manufactured for easy installation. The units are designed to be mounted on the wall. These units are designed to operate under normal street water pressure.
5. Technical Description
The pressure vessel of the water heater is welded glasslined steel and is equipped with a sacrificial anode rod.
The thermal insulation is made of polystyrene.
The water heater is equipped with both a thermostat and a high limit temperature switch. A temperature/ pressure relief valve is supplied with the unit.
4 | SHC 2.5 / SHC 4 www.stiebel-eltron-usa.com
advertisement
Related manuals
advertisement
Table of contents
- 3 General Information
- 3 Safety Precautions
- 4 Register your product
- 4 General Description
- 4 Technical Description
- 5 Technical Data
- 5 6.1 Dimensions, SHC
- 5 6.2 Dimensions, SHC
- 6 General Recommendations
- 6 Mounting the Unit
- 6 Plumbing Connections
- 7 9.1 Filling the Water Heater
- 7 10. Electrical Connection
- 8 10.1 Electrical diagram
- 8 11. Settings
- 8 12. Maintenance Instructions
- 9 12.1 Draining the water heater
- 9 12.2 Removing the cover
- 9 12.3 Removing the heating element
- 9 12.4 De-scaling the heating element
- 9 12.5 Replacing the heating element
- 10 12.6 Changing the anode rod
- 10 12.7 Safety Shut-off
- 11 13. Limited Warranty
- 13 Información general
- 14 Advertencias de seguridad
- 15 Registre su producto
- 15 Descripción general
- 15 Descripción técnica
- 15 Datos técnicos
- 16 6.1 Dimensiones, SHC
- 16 6.2 Dimensiones, SHC
- 16 Recomendaciones generales
- 16 Cómo montar la unidad
- 17 Conexiones de plomería
- 18 9.1 Cómo llenar el calentador de agua
- 18 10. Conexión eléctrica
- 19 10.1 Diagrama eléctrico
- 19 11. Configuraciones
- 19 12. Instrucciones de mantenimiento
- 20 12.1 Cómo vaciar el calentador de agua
- 20 12.2 Cómo remover la cubierta
- 20 12.3 Cómo remover el elemento calefactor
- 20 calefactor
- 20 12.5 Cómo reemplazar el elemento calefactor
- 21 12.6 Cómo cambiar el ánodo
- 21 12.7 Apagado de seguridad
- 22 13. Garantía Limitada
- 24 Généralités
- 26 Description
- 26 Inscrivez votre produit
- 26 Description technique
- 26 Données techniques
- 26 6.1 Dimensions, SHC
- 27 6.2 Dimensions, SHC
- 27 Recommandations générales
- 27 Fixation de l’appareil
- 28 Branchements de plomberie
- 29 9.1 Remplissage du chauffe-eau
- 29 10. Configuration électrique
- 30 10.1 Diagramme électrique
- 30 11. Réglages
- 30 12. Instructions relatives à l’entretien
- 31 12.1 Vidange du chauffe-eau
- 31 12.2 Retrait du couvercle
- 31 12.3 Retrait de l’élément chauffant
- 31 12.4 Détartrage de l’élément chauffant
- 31 12.5 Remplacement de l’élément chauffant
- 32 12.6 Remplacement de l’anode
- 32 12.7 Vanne d’isolement de sécurité
- 33 13. Garantie Limitée