Ensure that the water heater is installed in a level position.

Install a shut-off on the cold water side of the water heater. This is for emergency shut-off. It must be kept open when the water heater is operating.

When using copper piping, solder a piece of tubing to a threaded fitting (union) before screwing the adapter to the tank.

BRAIDED FLEX HOSE CONNECTORS ARE ALSO RECOM-

MENDED.

DO NOT APPLY HEAT DIRECTLY TO INLET OR OUTLET

CONNECTIONS.

A certified T&P valve is supplied with the water heater and must be installed. After all plumbing work has been completed, the T&P valve needs to be checked for proper tightness.

During heating, the water volume and water pressure increases in the tank. It is possible for water to leak from the safety valve, this is normal.

1

2

3

4 lief valves and automatic shut-off devices for hot water supply systems ANSI Z21.22.

The T&P valve is marked with a maximum pressure, which does not exceed the maximum working pressure of the water heater (150 PSI).

THE DISCHARGE PIPE

- Must not be smaller in size than the outlet pipe size of the valve, or have reducing couplings.

- Must not be plugged or blocked.

- Must be of material suitable for hot water.

- Must not be over fifteen feet (15´) in length.

- Must not have more than two elbows.

- Must terminate at an adequate drain.

- Must not have a valve between the relief valve and the tank.

9.1 Filling the Water Heater

To fill the water heater:

1. Open the hot water faucet.

2. Open the cold water supply valve.

3. When water runs out of the faucet, the tank is filled.

4. Close the hot water faucet.

5. Check entire system for leaks.

10. Electrical Connection

!

CAUTION:

ALWAYS FILL THE UNIT’S TANK WITH WATER

BEFORE PLUGGING THE WATER HEATER’S CORD

INTO AN ELECTRICAL OUTLET. FAILURE TO DO

SO WILL RESULT IN PERMANENT DAMAGE TO

THE WATER HEATER.

1. Temperature/Pressure relief valve

2. Hot water outlet

3. Cold water inlet

4. Discharge pipe

Install a discharge pipe from the relief valve terminating at a sink or drain. Orient the tubing so that discharge will exit within 6˝ (152 mm) above or at any distance below the structural floor, and cannot contact any live electrical parts.

DO NOT CAP OR THREAD THE END OF THE DISCHARGE

PIPE, IT MUST BE UNOBSTRUCTED AND FULL SIZE.

The T&P valve is certified by a nationally recognized test laboratory that maintains periodic inspection of the listed equipment, and meets the requirements for rewww.stiebel-eltron-usa.com

NOTICE:

THE WATER HEATER MUST BE CONNECTED TO

A GROUNDED OUTLET.

THIS WATER HEATER WAS DESIGNED FOR

USE AT 110 - 120 V. DO NOT USE THIS WATER

HEATER WITH ANY OTHER VOLTAGE. FAILURE

TO USE THE CORRECT VOLTAGE MAY RESULT

IN PERSONAL INJURY OR PROPERTY DAMAGE.

THE HEATER IS SUPPLIED WITH AN ELECTRICAL

CABLE WITH A PLUG. IF THE CABLE IS DAM-

AGED OR LENGTH NOT SUFFICIENT, IT MUST BE

REPLACED BY A LICENSED ELECTRICIAN.