Alarm Condition Configuration
4.12.1 Bit Settings
The bit settings available are: -
• Bit 0 - (value when set = 1) - Questionable in the device
• Bit 1 - (value when set = 2) - Data Collection Failure
• Bit 2 - (value when set = 4) - Device Offline
• Bit 3 - (value when set = 8) - Not a Number
4.12.2 Questionable in Device
When this box is checked, if the questionable value of the signal indicates that the value of the signal is questionable in the device, a NW3000 questionable alarm will be raised against the signal.
Remote Automation Solutions
Website: www.EmersonProcess.com/Remote
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 6 Alarm Condition Tool
- 6 Alarm Condition Tables
- 6 Alarm Condition Configuration
- 6 Alarm Condition Elements
- 6 Alarm Condition Lookup Table
- 10 Alarm Condition Tables
- 10 abdevicehealthalarmcondition
- 11 alarminhibitalarmcondition
- 11 alarminhibitstatealarmcondition
- 11 calculationstatusalarmcondition
- 11 digitalalarmcondition
- 11 digitalchangetonullalarmcondition
- 11 digitaldelayalarmcondition
- 12 digitalstatealarmcondition
- 12 integeranalogalarmcondition
- 12 integeranalogchangetonullalarmcondition
- 12 integeranalogchangeofvaluealarmcondition
- 12 integeranalogdeviationalarmcondition
- 12 integeranalogequalsalarmcondition
- 13 integeranaloglimitalarmcondition
- 13 integeranalograteofchangealarmcondition
- 13 integeranalogsignalalarmcondition
- 14 journalalarmcondition
- 14 journalequalalarmcondition
- 14 journalrangealarmcondition
- 14 multistatedigitalalarmcondition
- 14 notesalarmcondition
- 14 nw3000devicecommunicationalarmcondition
- 15 nw3000devicestatusalarmcondition
- 15 nw3000deviceversionalarmcondition
- 15 nw3000digitalalarmcondition
- 15 nw3000questionablealarmcondition
- 15 nw3000realanalogalarmcondition
- 15 oeprinteralarmcondition
- 16 oeprintergroupalarmcondition
- 16 questionablealarmcondition
- 16 questionableequalsalarmcondition
- 16 questionablerangealarmcondition
- 16 realanalogalarmcondition
- 16 realanalogchangeofvaluealarmcondition
- 16 realanalogchangetonullalarmcondition
- 17 realanalogdeviationalarmcondition
- 17 realanalogequalsalarmcondition
- 17 realanaloglimitalarmcondition
- 17 realanalograteofchangealarmcondition
- 18 realanalogsignalalarmcondition
- 18 redundancyalarmcondition
- 19 Alarm Condition Configuration
- 19 Alarm Condition Table Drop Down List
- 20 Filter Grid Entry
- 20 Filtering with Wildcards
- 21 Refresh Button
- 21 Options Button
- 21 Options
- 21 Number of Objects to Retrieve Field
- 21 Prompt for Filter Check Box
- 21 Next 100 Button
- 21 Alarm Condition List
- 22 Add Button
- 22 Delete Alarm Condition Button
- 22 Modifying Alarm Conditions
- 22 Help Button
- 22 Close Button
- 23 Add/Modify Alarm Condition
- 23 Priority
- 23 Precedence
- 24 Suppress
- 24 Suppression Groups
- 24 Alarm Redirection Button
- 24 Help Text
- 24 Condition Field
- 24 Signal
- 24 Limit Field
- 24 Dead Band In Field
- 25 Dead Band Out Field
- 25 Questionable Mask
- 26 Bit Settings
- 26 Questionable in Device
- 27 Data Collection Failure
- 27 Device Offline
- 27 Not a Number
- 27 OK Button
- 27 Cancel Button
- 27 Suppression Group Association
- 27 Available Suppression Groups
- 28 Add Suppression Group Button
- 28 Remove Suppression Group Button
- 28 Associated Suppression Groups
- 28 OK Button
- 28 Cancel Button
- 28 Alarm Redirection
- 29 Title Bar
- 29 Alarm Redirections
- 29 Add button
- 29 Alarm Redirection Properties
- 29 Alarm Redirection Description
- 30 Wait for
- 30 Set Priority Check
- 30 Set Priority to
- 30 Set Priority if current lower
- 30 Always
- 30 Set Plant Area Check
- 30 Plant Areas
- 30 Set Access Area Check
- 30 Access Areas
- 30 Set Occurrence Time Check
- 30 Set Digital Signal Check
- 31 Set Digital Name
- 31 Browse for Digital Signal
- 31 Browse for Signal Filter Grid
- 31 Browse for Signal Refresh Button
- 32 Browse for Signal Options Button
- 32 Options Dialog
- 32 Browse for Signal Filter Prompt
- 32 Browse for Signal Number of Objects
- 32 Browse for Signal Next Button
- 32 Signal List
- 32 Browse for Signal OK Button
- 32 Alarm Redirection Properties OK button
- 33 Alarm Redirection Properties Cancel button
- 33 Alarm Redirection Insert button
- 33 Alarm Redirection Modify button
- 33 Alarm Redirection Delete Button
- 33 Alarm Redirection Delete All button
- 33 Alarm Redirection Close button
- 33 Sound Configuration
- 34 Sound File
- 34 Play Sound Number of Times
- 34 Sound Configuration Example
- 35 Browse For Signal
- 36 Browse for Signal Filter Grid
- 36 Browse for Signal Refresh Button
- 36 Browse for Signal Options Button
- 37 Options
- 37 Browse for Signal Filter Prompt
- 37 Browse for Signal Number of Objects
- 37 Signal List
- 37 Browse for Signal Next Button
- 37 Browse for Signal OK Button
- 38 Glossary