3 SPECIFICATIONS
MELSEC-Q
3.8 List of Input/Output Signals for the PLC CPU
This section describes the input/output signals of the Q series C24.
For assignments of the input/output signals shown in the table below, it is assumed that the Q series C24 is mounted in slot 0 of the basic base unit.
Device numbers starting with X indicate input signals from the Q series C24 to the PLC
CPU, and device numbers starting with Y indicate output signals from the PLC CPU to the Q series C24.
The following table lists the input/output signals for the PLC CPU.
Reference section
Device number
Signal description
X0
X1
X2
X3
X4
X5
X6
X7
X8
X9
XA
XB
XC
XD
XE
XF
X10
X11
X12
1
1
1
2
2
3
1
1
1
2
2
3
6
6
6
CH1 Transmission normal completion
ON: Normal completion
CH1 Transmission abnormal completion
ON: Abnormal completion
CH1 Transmission processing
ON: Transmission in progress
CH1 Reception data read request
ON: Requesting read
CH1 Reception abnormal detection
ON: Abnormal detection
(For system)
CH1 Mode switching
ON: Switching
CH2 Transmission normal completion
ON: Normal Completion
CH2 Transmission abnormal completion
ON: Abnormal completion
CH2 Transmission processing
ON: Transmission in progress
CH2 Reception data read request
ON: Requesting read
CH2 Reception abnormal detection
ON: Abnormal detection
(For system)
CH2 Mode switching
ON: Switching
CH1 ERR. occurrence
ON: Error occurring
CH2 ERR. occurrence
ON: Error occurring
Modem initialization completion
ON: Initialization completed
Dialing
ON: Dial in progress
Connection
ON: Connection in progress
X13
X14
X15
X16
6
6
6
6
Initialization/connection abnormal completion
ON: Initialization/ connection abnormally completed
Modem disconnection complete
ON: Disconnection completed
Notification normal completion
ON: Normal completion
Notification abnormal completion
ON: Abnormal completion
X17 1 Flash ROM read completion ON: Completed
X18 1 Flash ROM write completion ON: Completed
X19
Flash ROM system setting write completion
ON: Completed
Reference section
Section 8.6.4
Section 8.6.5
Section 8.6.6
Section 6.1
Section 7.1
Section 8.6.5
Section 8.6.6
—
Application,
Chapter 15
Section 8.6.4
Section 8.6.5
Section 8.6.6
Section 6.1
Section 7.1
Section 8.6.5
Section 8.6.6
—
Application,
Chapter 15
Section 8.6.10
Section 10.1.2
Section 8.6.2
Application,
Chapter 3
—
Device number
Y0
Y1
Y2
Y3
Y4
Y5
Y6
Y7
Y8
Y9
YA
YB
YC
YD
Y17
Y18
Y19
CH1 Transmission request
ON: Requesting transmission
CH1 Reception data read completion
ON: Data read completed
CH1 Mode switching request
ON: Requesting switch
CH2 Transmission request
ON: Requesting transmission
CH2 Reception data read completion
ON: Data read completed
CH2 Mode switching request
ON: Requesting switch
Flash ROM read request ON: Requesting
Flash ROM write request ON: Requesting
Flash ROM system setting write request
ON: Requesting
Signal description
Use prohibited
Use prohibited
YE
YF
Y10 6
Y11 6
Y12 6
CH1 ERR.clear request
ON: Requesting error clear
CH2 ERR. clear request
ON: Requesting error clear
Modem initialization request (standby request)
ON: Requesting initialization
Connection request
ON: Requesting connection
Modem disconnection request
ON: Requesting disconnection
Y13
Y14 6
Notification- issued request
OFF: Requesting notification issuance
Y15
Y16
Use prohibited
Use prohibited
—
Application,
Chapter 15
—
—
Application,
Chapter 15
—
Section 8.6.10
Section 10.1.2
Section 8.6.2
Application,
Chapter 3
—
—
—
3 - 15 3 - 15
3 SPECIFICATIONS
MELSEC-Q
Device number
X1A
X1B
X1C
Signal description
CH1 Global signal ON: Output instructed
CH2 Global signal ON: Output instructed
System setting default completion
ON: Completed
(For system) X1D
X1E 4 Q series C24 ready ON: Accessible
X1F 5
Watchdog timer error (WDT error)
ON : Module error occurred
OFF: Module being normally operated
Reference section
Section 3.10,
Reference
Section 8.4.11
—
—
—
Device number
Y1A
Y1B
Y1C
Y1D
Y1E
Y1F
Signal description
Use prohibited
System setting default request
ON: Requesting
Use prohibited
Reference section
—
Section 8.4.11
—
1 The device does not turn on/off by execution of a dedicated instruction when a function that corresponds to the input signal is used.
2 The device does turn on/off by execution of a dedicated instruction when a function that corresponds to the input signal is used (from ON to OFF: Data read completed).
3 The mode switching signal (X6/XD) turns ON at mode switching, receive clear, user frame receive designation or transmission sequence initialization.
While the mode switching signal (X6/XD) is ON, do not issue a communication request to the target interface.
(The communication processing of the Q series C24 is stopped while the mode switching signal (X6/XD) is ON.)
4 The Q series C24 ready signal indicates whether or not it is possible to access the
Q series C24 from the PLC CPU.
Use it as a interlock signal for a sequence program.
(It turns on about one second after turning the power ON and reset operation.)
5 Restart the PLC CPU when the watchdog timer error signal is turned on (reset the power and the CPU module).
6 QJ71C24N-R4 cannot be used. (Related to modem function signal.)
• X10 to X16: For system
• Y10 to Y16: Use prohibited
IMPORTANT
(1) Of the input/output signals to the PLC CPU, the signals marked with "Use prohibited" must not be output (ON).
If any of the "Use prohibited" signals is output, the PLC system may malfunction.
(2) When the modem function is not used or the QJ71C24N-R4 is used, X10 to
X16 are used for the system and Y10 to Y16 cannot be used.
POINT
(1) The input/output signals shown in this section are the signals used when a QnA series serial communication module program is utilized for the Q series C24
(see Section 2 in appendix).
In the QCPU, the on/off of input/output signals to intelligent function modules is executed with a dedicated instruction.
It is not necessary to turn the signals on/off by the sequence program, except for the input/output signals shown in the programming of each function reference page.
(2) When a program for a QnA series serial communication module is also utilized for the Q series C24, it is recommended to replace the instructions with the dedicated instructions shown on the corresponding function reference page of each manual for the Q series C24.
3 - 16 3 - 16
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 3 SAFETY PRECAUTIONS
- 7 REVISIONS
- 9 INTRODUCTION
- 9 CONTENTS
- 17 About Manuals
- 17 Conformation to the EMC Directive and Low Voltage Instruction
- 18 The Manual's Use and Structure
- 21 About The Generic Terms and Abbreviations
- 23 Definitions and Descriptions of Terminology
- 25 Product Configuration
- 26 1 OVERVIEW
- 26 1.1 Overview of the Serial Communication Module
- 27 1.2 Features of the Serial Communication Module
- 35 1.3 About Added/Changed Functions in Function Version B
- 37 2 SYSTEM CONFIGURATION AND AVAILABLE FUNCTIONS
- 37 2.1 Applicable Systems
- 39 2.2 Combinations of PLC CPU and External Device, and Available Functions
- 42 2.3 For Use in Multiple CPU System
- 43 2.4 For Use with Q00J/Q00/Q01CPU
- 44 2.5 For Use at MELSECNET/H Remote I/O Station
- 48 2.6 Checking the Function Version, Serial No., and Software Version
- 51 3 SPECIFICATIONS
- 51 3.1 Performance Specifications
- 53 3.2 RS-232 Interface Specification
- 53 3.2.1 RS-232 connector specifications
- 55 3.2.2 RS-232 cable specification
- 56 3.3 RS-422/485 Interface Specifications
- 56 3.3.1 RS-422/485 terminal block specifications
- 57 3.3.2 RS-422/485 cable specifications
- 58 3.3.3 Precautions when transferring data using RS-422/485 circuit
- 61 3.4 Serial Communication Module Function List
- 62 3.5 Dedicated Instruction List
- 63 3.6 Utility Package (GX Configurator-SC) Function List
- 64 3.7 List of GX Developer Setting Items for Serial Communication Modules
- 65 3.8 List of Input/Output Signals for the PLC CPU
- 67 3.9 List of Applications and Assignments of the Buffer Memory
- 82 4 SETTINGS AND PROCEDURES PRIOR TO OPERATION
- 82 4.1 Handling Precautions
- 83 4.2 Settings and Procedures Prior to Operation
- 84 4.3 Part Names and Functions
- 86 4.4 External Wiring
- 87 4.4.1 Connecting the RS-232 interface (full-duplex communications)
- 89 4.4.2 Connecting the RS-422/485 interface
- 93 4.5 Settings for GX Developer
- 93 4.5.1 I/O assignment settings
- 94 4.5.2 Switch settings for I/O and intelligent functional module
- 101 4.5.3 The Intelligent function module interrupt pointer setting
- 103 4.6 Settings with the Utility Package (GX Configurator-SC)
- 106 4.7 Individual Station Test
- 106 4.7.1 ROM/RAM/switch tests
- 109 4.7.2 Individual station loopback test
- 111 4.8 Loopback Test
- 113 4.9 Maintenance and Inspection
- 113 4.9.1 Maintenance and inspection
- 114 4.9.2 When mounting/dismounting the module
- 115 5 DATA COMMUNICATION USING THE MELSEC COMMUNICATION PROTOCOL
- 115 5.1 Data Communication Functions
- 115 5.1.1 Accessing the PLC CPUs using the MC protocol
- 116 5.1.2 Message format and control procedure for data communication
- 116 5.1.3 PLC CPU setting for performing data communication
- 117 5.1.4 Support of multiple CPU system or redundant system
- 118 5.1.5 Support for the QCPU remote password function
- 120 5.2 Utilizing the MX Component
- 121 6 DATA COMMUNICATION USING THE NON PROCEDURE PROTOCOL
- 122 6.1 Data Reception from the External Device
- 122 6.1.1 Receiving methods
- 126 6.1.2 The receive area and the received data list
- 131 6.1.3 Sequence program for data reception
- 134 6.1.4 Receive data clear
- 137 6.1.5 How to detect reception errors
- 140 6.1.6 Received data count and receive complete code settings
- 142 6.2 Sending Data to the External Device
- 142 6.2.1 Transmission methods
- 143 6.2.2 Arrangement and contents of the transmission area and the transmission data
- 145 6.2.3 Sequence program for transmission data
- 148 6.2.4 How to detect transmission errors
- 150 6.3 Data Communications Precautions
- 152 7 DATA COMMUNICATION USING THE BIDIRECTIONAL PROTOCOL
- 153 7.1 Data Reception from the External Device
- 153 7.1.1 Receiving methods
- 155 7.1.2 Arrangement and contents of the receive area and the receive data
- 161 7.1.3 Sequence program for data reception
- 164 7.1.4 How to detect reception errors
- 165 7.1.5 Receive data clear
- 166 7.2 Sending Data to the External Device
- 166 7.2.1 Transmission methods
- 167 7.2.2 Arrangement and contents of the transmission area and the transmission data
- 170 7.2.3 Sequence program for data transmission
- 173 7.2.4 How to detect transmission errors
- 175 7.3 Processing when Simultaneous Transmission Performed During Full-Duplex Communications
- 175 7.3.1 Processing when simultaneous transmissions occur
- 176 7.3.2 Communication data processing when simultaneous transmissions occur
- 178 7.4 Data Communications Precautions
- 180 8 UTILITY PACKAGE (GX Configurator-SC)
- 181 8.1 Functions Available with Utility Package
- 182 8.2 Installing and Uninstalling Utility Package
- 182 8.2.1 Usage precautions
- 184 8.2.2 Operating environment
- 185 8.3 Explanation of Utility Package Operation
- 185 8.3.1 Operation overview
- 189 8.3.2 Starting the intelligent function module utility (displaying the [select parameter setting module] screen)
- 192 8.3.3 Performing common utility operations
- 195 8.4 System Registration to Flash ROM
- 197 8.4.1 User frame registration
- 198 8.4.2 Data for modem initialization registration
- 199 8.4.3 Data for modem connection registration
- 200 8.4.4 Modem function system setting/registration
- 201 8.4.5 Transmission control and others system setting
- 203 8.4.6 MC protocol system setting
- 204 8.4.7 Non procedure system setting
- 205 8.4.8 Bidirectional system setting
- 206 8.4.9 PLC CPU monitoring system setting
- 208 8.4.10 Transmission user frame No. designation system setting
- 209 8.4.11 Resetting the buffer memory/flash ROM setting values to the default values
- 209 8.4.12 Flash ROM write allow/prohibit setting
- 210 8.5 Auto Refresh Setting
- 211 8.6 Monitor/Test
- 212 8.6.1 X · Y monitor/test
- 213 8.6.2 Modem function monitor/test
- 216 8.6.3 Transmission control and others monitor/test
- 218 8.6.4 MC protocol monitor
- 220 8.6.5 Non procedure monitor/test
- 222 8.6.6 Bidirectional monitor
- 223 8.6.7 PLC CPU monitoring monitor
- 225 8.6.8 Transmission user frame No. designation monitor
- 226 8.6.9 Monitor/test others
- 228 8.6.10 Display LED off and communication error information/error code initialization
- 230 8.7 Non Procedure Protocol Receive Data Clear
- 231 9 DEDICATED INSTRUCTIONS
- 231 9.1 Dedicated Instruction List
- 232 9.2 ONDEMAND Instruction
- 235 9.3 OUTPUT Instruction
- 238 9.4 INPUT Instruction
- 241 9.5 BIDOUT Instruction
- 244 9.6 BIDIN Instruction
- 247 9.7 SPBUSY Instruction
- 249 9.8 CSET (Receive data clear)
- 252 10 TROUBLESHOOTING
- 252 10.1 Checking the Status of the Serial Communication Module
- 252 10.1.1 Checking the LED ON status, communications error status, and switch setting status of the serial communication module
- 257 10.1.2 Initializing error information of the serial communication module
- 260 10.1.3 Reading the RS-232 control signal status
- 261 10.1.4 Reading the data communication status (Transmission sequence status)
- 262 10.1.5 Reading the switch setting status
- 264 10.1.6 How to read the current operation status
- 266 10.2 Error Code Tables
- 266 10.2.1 Error code table
- 275 10.2.2 A compatible 1C frame communications error code table
- 276 10.2.3 Error code list while modem function is used
- 278 10.3 Troubleshooting by Symptom
- 280 10.3.1 Troubleshooting when "RUN" LED is turned OFF
- 281 10.3.2 Troubleshooting when "RD" LED does not blink even though an external device is transmitting a message
- 282 10.3.3 Troubleshooting when the Q series C24 does not return a response message even though an external device ...
- 283 10.3.4 Troubleshooting when an external device transmitted a message and "RD" LED blinked, but the Read Request signal ...
- 284 10.3.5 Troubleshooting when communication error "NAK" generates
- 284 10.3.6 Troubleshooting when communication error "C/N" generates
- 285 10.3.7 Troubleshooting when communication error "P/S" generates
- 286 10.3.8 Troubleshooting when communication error "PRO." generates
- 287 10.3.9 Troubleshooting when communication error "SIO" generates
- 288 10.3.10 Troubleshooting when communication error "CH1 ERR.", "CH2 ERR." generate
- 289 10.3.11 Troubleshooting when communications is intermittently established and lost
- 290 10.3.12 Troubleshooting when data that cannot be decoded is transmitted and received
- 291 10.3.13 Troubleshooting when it is unclear whether the communication error cause is in the Q series C24 or an external device
- 292 10.3.14 Troubleshooting when data cannot be communicated via modem
- 293 10.3.15 Troubleshooting when data cannot be communicated with the ISDN sub-address
- 293 10.3.16 Troubleshooting when constant cycle transmission does not operate normally
- 293 10.3.17 Troubleshooting when condition agreement transmission does not operate normally
- 293 10.3.18 Troubleshooting when data cannot be received by an interrupt program
- 293 10.3.19 Troubleshooting when data cannot be written to Flash ROM
- 294 10.3.20 Troubleshooting when the "ERR" LED is lit
- 295 APPENDIX
- 295 Appendix 1 Functional Improvements of the Q Series C24
- 295 Appendix 1.1 Comparison of the Functions of Q Series C24/GX Configurator-SC
- 299 Appendix 1.2 Precautions when Updating the Module from Function Version A to B
- 300 Appendix 2 QnA/A Series Module
- 300 Appendix 2.1 Functional Comparison with the Q series C24 and the QnA/A Series Modules
- 302 Appendix 2.2 Using Programs Designed for the QC24 (N) and Installing the Q Series C24 into Existing Systems
- 302 Appendix 2.2.1 Using programs designed for the QC24 (N)
- 303 Appendix 2.2.2 Installing on existing systems
- 304 Appendix 2.3 Using Programs Designed for the Computer Link Module and Installing the Q Series C24 into Existing Systems
- 304 Appendix 2.3.1 Using programs designed for the computer link module
- 307 Appendix 2.3.2 Installing the Q series C24 into existing systems
- 308 Appendix 3 Processing Time
- 311 Appendix 4 ASCII-Code Table
- 312 Appendix 5 External Dimensions
- 314 Appendix 6 Example of Connection when a Converter is Used
- 317 Appendix 7 Communication Support Tool (MX Component)
- 317 Appendix 7.1 Overview of MX Component
- 320 Appendix 7.2 Usage Procedure of MX Component
- 324 Appendix 8 Example of Clear Process Program for Receive Data
- 326 Appendix 9 Program Examples for Using Q Series C24 at MELSECNET/H Remote I/O Station
- 326 Appendix 9.1 System configuration and program conditions
- 328 Appendix 9.2 When accessing buffer memory using sequence program
- 329 Appendix 9.3 When sending on-demand data
- 331 Appendix 9.4 When receiving data using nonprocedural or bidirectional protocol
- 333 Appendix 9.5 When sending data using nonprocedural or bidirectional protocol
- 335 Appendix 9.6 When clearing received data
- 337 Appendix 9.7 When sending data using user frames
- 340 Appendix 9.8 When performing initial setting
- 342 Appendix 9.9 When registering user frame
- 344 Appendix 9.10 When reading user frame
- 346 Appendix 9.11 When deleting user frame
- 348 Appendix 9.12 When changing the communication protocol and transmission setting
- 351 Appendix 10 Setting Value Recording Sheet
- 353 INDEX
- 355 WARRANTY