OMRON C200H-TV 00, 10, 01, 02, 03 Temperature Control Unit, C200H-DSC 01 Data Setting Console, C200H-CN 225, 425 Connecting cable, E54-CT 1, 3 Current Transformer Operation Manual
Below you will find brief information for Temperature Control Unit C200H-TV 00, Temperature Control Unit C200H-TV 10, Temperature Control Unit C200H-TV 01. The Temperature Control Unit measures the temperature of an object with a connected temperature sensor (thermocouple or platinum resistance thermometer) and controls the temperature according to preset parameters. Stable temperature control is achieved using advanced PID control and an autotuning feature. ON/OFF control can also be selected. The Data Setting Console is used to input data and to display process values (PV) and set values (SV).
Advertisement
Advertisement
C200H-TV Heat/Cool Temperature Control Unit Operation Manual Cat. No. W240-E3-1 Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. Failure to head precautions can result in injury to people or damage to the product. DANGER! Indicates information that, if not heeded, is likely to result in loss of life or serious injury. WARNING Indicates information that, if not heeded, could possibly result in loss of life or serious injury. Caution Indicates information that, if not heeded, could result in relative serious or minor injury, damage to the product, or faulty operation. OMRON Product References All OMRON products are capitalized in this manual. The word “Unit” is also capitalized when it refers to an OMRON product, regardless of whether or not it appears in the proper name of the product. The abbreviation “Ch,” which appears in some displays and on some OMRON products, often means “word” and is abbreviated “Wd” in documentation in this sense. The abbreviation “PC” means Programmable Controller and is not used as an abbreviation for anything else. Visual Aids The following headings appear in the left column of the manual to help you locate different types of information. Note Indicates information of particular interest for efficient and convenient operation of the product. 1, 2, 3... 1. Indicates lists of one sort or another, such as procedures, checklists, etc. OMRON, 1998 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of OMRON. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because OMRON is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication. v TABLE OF CONTENTS SECTION 1 System Configuration and Features . . . . . . . . . . . . . . . . . 1-1 1-2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Basic System Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 2 Connections and Settings . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 2-2 2-3 Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3-1 Input Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3-2 Output Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3-3 Data Setting Console Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 3 Data Setting Console Operation . . . . . . . . . . . . . . . . . . . . 3-1 3-2 3-3 3-4 Operating Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Data Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nomenclature and Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3-1 Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3-2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Parameter Displays and Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4-1 Table of Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4-2 How to Display and Set Parameter Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 4 PC Memory Allocation and Programming . . . . . . . . . . . 4-1 4-2 4-3 Memory Allocation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1-1 Memory Allocation Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1-2 Memory Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1-3 Table of Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Data Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3-1 Example with SW2-1 in the Fixed Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3-2 Example 1: Write with SW2-1 in the Normal Position . . . . . . . . . . . . . . . . . . . . 4-3-3 Example 2: Read with SW2-1 in the Normal Position . . . . . . . . . . . . . . . . . . . . 4-3-4 Operation Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 5 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Error Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B Sensor Temperature Measurement Ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C Heater Burnout Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D Parameters and Key Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2 3 5 6 7 10 10 13 17 19 20 21 22 22 23 24 24 26 35 36 37 38 41 43 43 43 44 47 50 53 54 57 59 61 67 69 71 vii About this Manual: This manual describes the installation and operation of the C200H-TV Heat/Cool Temperature Control Unit and includes the sections described below. Also briefly described is the basic operation and installation of the C200H-DSC01 Data Setting Console. Please read this manual carefully and be sure you understand the information provided before attempting to install and operate the Heat/Cool Temperature Control Unit and Data Setting Console. Section 1 provides Heat/Cool Temperature Control Unit features and describes its basic system configuration. Section 2 provides information on the connections and settings of the Heat/Cool Temperature Control Unit. Section 3 provides the basic operating procedures of the Data Setting Console including parameter settings and displays. Section 4 provides the C200H PC’s memory allocation for the Heat/Cool Temperature Control Unit. Basic programming procedures and examples are also provided. Section 5 provides possible errors and error remedies. The five Appendices provide references dealing with specifications, sensor temperature measurement ranges, heater burnout detection, and dimensions, and a table of Data Setting Console key operations. WARNING Failure to read and understand the information provided in this manual may result in personal injury or death, damage to the product, or product failure. Please read each section in its entirety and be sure you understand the information provided in the section and related sections before attempting any of the procedures or operations given. ix SECTION 1 System Configuration and Features This section provides Heat/Cool Temperature Control Unit features and describes its basic system configuration. 1-1 1-2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Basic System Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 3 1 Features 1-1 Section 1-1 Features The Heat/Cool Temperature Control Unit measures the temperature of an object with a connected temperature sensor (thermocouple or platinum resistance thermometer) and controls the temperature according to preset parameters. Advanced PID Control Stable temperature control is achieved using advanced PID control and an autotuning feature. ON/OFF control can also be selected. Units Available According to Type of Temperature Sensor Two types of Temperature Control Unit are available, according to the temperature sensor used. The C200H-TV00 uses a thermocouple, and the C200H-TV10 uses a platinum resistance thermometer. Two Heat/Cool Control Loops with a Single Unit Two heating and cooling control loops are possible with one Unit. Comprehensive Output Specifications Three types of output specification versions are available: C200H-TV1 for transistor output, C200H-TV2 for voltage output, and C200H-TV3 for current output. Heater Burnout Detection A Current Transformer (with a detection current range of 0.1 to 49.9 A and a minimum detection current difference of 2.5 A) can be connected to each of the two control loops to facilitate rapid heater burnout detection and prompt correction of problems. Eight Banks of Data Settings Eight data values such as set point (SP) and alarm set values can be preset in eight data banks for easy selection. Data Input and Display The C200H-DSC01 Data Setting Console (sold separately) is used to input data and to display process values (PV) and set values (SV). The easy-to-read display can be panel-mounted. User Programs Allow Reading and Writing of Data Data can be set and retrieved by means of C200H user programs. 2 Basic System Configuration 1-2 Section 1-2 Basic System Configuration C200H PC Heat/Cool Temperature Control Unit: C200H-TV00 (for thermocouples) C200H-TV10 (for platinum resistance thermometers) Connecting cables: C200H-CN225 (2 m) C200H-CN425 (4 m) Data Setting Console C200H-DSC01 Recommended cable: ES1000-CA021-051 (0.5 m) ES1000-CA021-102 (1 m) ES1000-CA021-202 (2 m) 24 VDC Loop 1 Temperature sensor Temperature sensor Loop 2 Extruder Heater Valve Heater Valve Remote I/O Terminal or Connector Terminal Block Converter Unit (Refer to page 16) Relay box Coolant Coolant Current Transformer (CT) Current Transformer (CT) Solenoid switch Heat/Cool Temperature Control Unit Models Output type Sensor Transistor output Voltage output Current output Thermocouple C200H-TV001 C200H-TV002 C200H-TV003 Platinum resistance thermometer C200H-TV101 C200H-TV102 C200H-TV103 3 Basic System Configuration Number of Units Section 1-2 The Heat/Cool Temperature Control Unit belongs to the C200H Special I/O Unit group. A maximum of ten Special I/O Units (including PC Link Units) can be mounted on each of the following Racks: CPU Rack, Expansion I/O Rack, and Slave Rack. Note Configure the Units such that the maximum current supplied for each Rack is greater than or equal to the total current consumption for the Units. Refer to the C200H PC Operation Manuals. Number of Units Mountable on Slave Rack The number of Special I/O Units used with a Slave Rack is limited by data transmission considerations, as shown in the table below. The numbers in the table indicate the maximum number of Units of groups A, B, C, or D which can be used with a single Slave Rack. A B C D High-speed Counter Units Position Control Units (NC111/112) ASCII Units ID Sensor Units Fuzzy Logic Units High-density and Mixed I/O Units Temperature Control Units Heat/Cool Temperature Control Units PID Control Units Cam Positioner Units Temperature Sensor Units Voice Units Position Control Units (NC211) 4 units max. 8 units max. 6 units max. 2 units max. Note 1. When a combination of Units from groups A, B, C, and D is used, the number from each group must satisfy both the following equations: 3A + B + 2C + 6D ≤ 12 A+B+C+D≤8 2. Other Units can be added until the total number of Units reaches ten. If PC Link Units are used, the number of Units including the PC Link Units must not exceed ten. Precautions The IR area of the C200H Special I/O Unit is allocated according to the setting of the unit number switch on the front panel, not the address of the slot where the unit is mounted. Refer to 4-1 Memory Allocation for the allocation of the memory area. Leave the two slots next to the CPU free. It is not possible to use devices connected to the CPU (such as the Programming Console) if these slots are occupied. If the C200H Slave Rack is connected to another SYSMAC model Remote I/O Master Unit, such as the C120, C500, C1000H, or C2000H, it is not possible to use a Special I/O Unit with the C200H Slave Rack. WARNING Always turn the C200H power off before connecting or disconnecting a Unit, terminal block, or output connector. Caution 4 Connect thermocouples with the appropriate compensating conductor. Wire I/O leads in separate ducts from power leads to prevent noise problems. SECTION 2 Connections and Settings This section provides information on the connections and settings of the Heat/Cool Temperature Control Unit. 2-1 2-2 2-3 Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3-1 Input Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3-2 Output Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3-3 Data Setting Console Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 7 10 10 13 17 5 Section 2-1 Nomenclature 2-1 Nomenclature C200H-TV00 (For Thermocouple) Front Panel Rear Panel Model label Cover RUN indicator SW202 (input type setting) SW2 (switching memory contents and setting direction under the cover) SW1 (Unit number setting) SW203 (operation and function settings) Data Setting Console connector Rack connector Output connector Sensor input terminal block Cold junction compensator C200H-TV10 (For Platinum Resistance Thermometer) Front Panel Rear Panel Model label Cover RUN indicator SW2 (switching memory contents and setting direction under the cover) SW1 (Unit number setting) SW202 (input type setting) SW203 (operation and function settings) Data Setting Console connector Rack connector Output connector Sensor input terminal block 6 Switch Settings Section 2-2 Indicators RUN 2-2 Lit when the Heat/Cool Temperature Control Unit is operating normally. Unlit when an alarm occurs, and Unit operation stops. Switch Settings The function and setting of switches are identical for all models, except SW202. Unit Number SW1 Unit number setting 4 (3) 2 (1) (5) 0 (9) 8 (7) 6 The cut-out indicates the selected position. Negative numbers are not indicated. Turn the switch with a flat-blade screwdriver. Turn the switch until it clicks in position. Do not leave the switch between two settings. The addresses are allocated as shown in the following table according to the Unit number setting. Unit no. setting Allocated address 0 Wd 100 to 109 1 Wd 110 to 119 2 Wd 120 to 129 3 Wd 130 to 139 4 Wd 140 to 149 5 Wd 150 to 159 6 Wd 160 to 169 7 Wd 170 to 179 8 Wd 180 to 189 9 Wd 190 to 199 The switch is factory-set to 0. Note If the Unit number is set to an existing Unit number, an alarm occurs and the C200H does not operate. Turn the C200H power off before setting the Unit number. If the setting is changed with the power on, the new setting is not valid until the power is turned off and back on again. Switching Memory Contents and Setting Direction SW2 Switching memory contents and setting direction 2 1 Remove the cover and set the switch with the tip of a ballpoint pen or a similar object. O F F ON OFF 7 Switch Settings Section 2-2 Switch no. Pin 1 Pin 2 Function Switching memory contents Setting direction ON Normal C200H PC OFF Fixed Data Setting Console The new setting is valid immediately after the switch setting is changed. Removing and Attaching the Cover Removing the Cover Attaching the Cover Place the right edge of the cover against the case and press into position. Insert a small flat-blade screwdriver between the case and the cover at the top of the Unit and lever off the cover. Switching Memory Contents The methods for designating parameters differ as shown below. Normal Parameters can be designated as required using commands. (Refer to 4-1 Memory Allocation). Fixed Parameters are allocated in advance. Refer to 4-1 Memory Allocation for details of the memory contents. Setting Direction Selector Selects whether the data settings are made from the Data Setting Console or from the C200H PC, using a user program or Programming Console. Executed Bank Number The setting of the executed bank number is made from the C200H PC, regardless of the ON/OFF setting of this switch. Input Type SW202 Input type setting 8 7 9 01 2 3 6 5 4 C200H-TV00 Setting 0 1 2 3 4 5 6 7 8 9 Sensor type R S K J T E B N L U The switch is factory-set to 2. The selected position is shown by the arrow. Turn the switch with a small flatblade screwdriver. Selected position 8 Switch Settings Section 2-2 C200H-TV10 OFF ON Setting Input type OFF JPt 100 ON Pt 100 The switch is factory-set to OFF. See Appendix B Sensor Temperature Measurement Range for the measurable temperature range. Operation and Function Setting Operation and Function Setting 1 2 3 4 5 6 SW203 NO OFF Pin no. ON Function OFF ON 6 Loop 1 Cooling control output Pulses Current output 5 SP write mode Write to EEPROM and RAM Write to RAM only 4 Loop 2 Enabled Disabled or not used 3 Display unit °C °F 2 Not used. --- --- 1 Control method PID control ON/OFF control The switch is factory-set to OFF. Loop 1 Cooling Control Output This setting is valid when the heating output type is “current,” and input loop 2 is not used (i.e., when pin no. 4 of switch 203 is ON). SP Write Mode This setting selects the SP storage memory. Set it to ON if the writing is to be frequently changed. Loop 2 Set to “enabled” to use input loop 2, or to “disabled” to use only input loop 1. It is not possible to use only input loop 2. Note Always set this switch to the ON (disabled) position when input loop 2 is not used. A sensor error occurs if this switch is set to the OFF (enabled) position when no temperature sensor is connected to loop 2. Display Unit Selects whether displays and set values are shown on the Data Setting Console in Celsius or in Fahrenheit. Control Method Selects the method of control. 9 Wiring 2-3 Section 2-3 Wiring 2-3-1 Input Wiring C200H-TV00 Thermocouple CT: Current Transformer TC: Thermocouple A0 CT A1 Loop 1 A2 TC A3 A4 CT A5 Loop 2 A6 TC A7 A8 24 VDC 0.2 A A9 The 24-VDC output from the C200H CPU or the Power Supply Units is convenient. Terminal no. 10 Terminal name A0 CT A1 CT A2 TC (–) A3 TC (+) A4 CT A5 CT A6 TC (–) A7 TC (+) A8 24 VDC A9 GND Loop 1 Loop 2 Refer to the table below. Wiring Section 2-3 C200H-TV10 Platinum Resistance Thermometer CT: Current Transformer Pt: Platinum resistance thermometer Heater wire A0 CT A1 Loop 1 A2 Pt A3 A4 CT A5 Loop 2 Refer to the table below. A6 Pt A7 A8 24 VDC 0.2 A A9 The 24-VDC output from the C200H CPU or the Power Supply Units is convenient. Terminal no. Terminal name A0 CT A1 CT/Pt (B) A2 Pt (B) A3 Pt (A) A4 CT A5 CT/Pt (B) A6 Pt (B) A7 Pt (A) A8 24 VDC A9 GND Loop 1 Loop 2 Screw down Pt(B) and CT together at terminals A1 and A5. Input Wiring Precautions 1, 2, 3... 1. Set the type of temperature sensor to thermocouple or platinum resistance thermometer with SW202 on the rear of the Unit. The Unit will not operate correctly if the switch setting does not match the type of temperature sensor connected. Do not connect different types of temperature sensors to Loop 1 and Loop 2. 2. If no input lead is connected to Loop 2, turn SW203-4 on the rear of the Unit ON to disable Loop 2. A sensor error occurs if this switch is set to the OFF (enabled) position when no temperature sensor is connected to Loop 2. 3. Be sure to connect (+) and (–), and (A) and (B) correctly. 4. Wire I/O leads in separate ducts from power leads to prevent noise problems. 5. A voltage of 24 VDC is used for the voltage output, current output and Data Setting Console power supply. 6. The terminal block is removable. Make sure that it is attached correctly after the input wiring connections are completed. 11 Wiring Section 2-3 Terminal Block Connections Crimp terminals are recommended for the wiring. Take care not to overtighten the terminal screws. Tightening torque must not exceed 78 N cm (8 kg cm). Crimp Terminals The screws on the terminal block are M3.5 self-rising terminal screws. Use the following types of M3.5 crimp terminals. 7 mm max. 7 mm max. Soldered Lead Strip insulation from 7 to 10 mm at the end of the wire and carefully solder the lead. ÉÉÉ ÉÉÉ 7 to 10 mm 10 Compensating Conductors Type of thermocouple Symbol Previous symbol (reference) Connect a thermocouple with the appropriate compensating conductor from the table below. Compensating conductor Symbol Previous symbol (reference) General-purpose, standard t d d class l Constituent materials + conductor B --- BX-G R --- RX-G, SX-G --- S --- RX-H, SX-H --- Heat-resistant, standard class K CA KX-G WCA-G KX-GS WCA-GS General-purpose, standard t d d class l KX-H WCA-H Heat-resistant, standard class KX-HS WCA-HS Heat-resistant, precision class WX-G WCA-G General-purpose, standard class WX-H WCA-H Heat-resistant, standard class VX-G WCA-G General-purpose, standard class Copper EX-G WCRC-G General-purpose, standard class EX-H WCRC-H Heat-resistant, standard class Alloy with nickel or chrome as j major constituent JX-G WIC-G General-purpose, standard class JX-H WIC-H Heat-resistant, standard class E J 12 CRC IC --- Classification by y application li ti and d tolerance Copper – conductor Copper Alloy y with copper or nickel i k l as major j constituent Alloy y with nickel Alloy y with nickel as or chrome h as major j constituent tit t major constituent Iron Iron Alloy with copper j or nickel as major constituent tit t Wiring Section 2-3 Type of thermocouple Symbol T Compensating conductor Previous symbol (reference) CC Symbol Previous symbol (reference) Classification by application and tolerance TX-G WCC-G General-purpose, standard class TX-GS --- General-purpose, precision class TX-H WCC-H Heat-resistant, standard class TX-HS --- Heat-resistant, precision class Constituent materials + conductor – conductor Alloy with copper or nickel as major j tit t constituent Copper Wiring Platinum Resistance Thermometers Connect a platinum resistance thermometer with copper wire. All three leads should have the same thickness and the same length to give them identical resistances. Do not branch the two (B) leads near the terminal block as this increases measurement errors. Current Transformer Use an E54-CT1 or E54-CT3 Current Transformer (CT). Refer to Appendix C Heater Burnout Detection for details of the Current Transformer specifications and installation dimensions. 2-3-2 Output Wiring Connection Diagrams C200H-TV01 Transistor Output HEAT1 HEAT2 COOL1 COOL2 COM 24 VDC 24 VDC NC: Not connected The pairs of terminals B2 to A2 and B1 to A1 are shorted internally. Always supply power to the 24-VDC terminal (B1) as this drives the internal circuits. 13 Wiring Section 2-3 C200H-TV02/TV03 Voltage/Current Output (–) (–) + 24 VDC 24 VDC Circuit Diagrams C200H-TV01 Transistor Output Internal circuits 24 VDC OUT COM Internal circuits C200H-TV02 Voltage Output OUT (+) OUT (–) Internal circuits C200H-TV03 Current Output OUT (+) OUT (–) Applicable Connectors 14 The following connector set manufactured by Fujitsu is included with the Unit: FCN-361J032-AU (soldering connector) FCN-360C032-B (cover) Wiring Section 2-3 Connector Wiring Precautions After soldering the lead to each pin, insulate with heat-shrink tube to prevent shorting with the adjacent terminal. Connection Precautions Tighten the screws after inserting the connector into the Unit. Push the connector firmly into the Remote I/O Terminal or Connector Terminal Block Converter Unit until it fully locks. Output Cable The output cables in the table below are recommended. Model Cable length (L) ES1000-CA021-051 0.5 m ES1000-CA021-102 1m ES1000-CA021-202 2m 32-pin connector (manufactured by Fujitsu) FCN-361J032-AU 20-pin connector (manufactured by OMRON) XG4M-2030 L XW2B-20G 20 19 18 30 63 17 16 15 12 13 16.1 28 11 14 10 46 9 7 8 6 Wiring Diagrams 5 4 3 1 32-pin connector Pin no. B16 B15 B14 B13 B12 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 Wire no. #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 2 20-pin connector Pin no. A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 Wire no. #11 #12 #13 #14 #15 #16 #17 #18 #19 #20 Note Pins A11 through A16 and B11 through B16 are not connected. Pin no. 1 2 3 4 5 6 7 8 9 10 Wire no. #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 Pin no. 11 12 13 14 15 16 17 18 19 20 Wire no. #11 #12 #13 #14 #15 #16 #17 #18 #19 #20 Pin no. 1 2 3 4 5 6 7 8 9 10 Pin no. Note The pin numbers of the 20-pin connector are marked for convenience. Refer to them from the ∆ mark. 11 12 13 14 15 16 17 18 19 20 Terminal no. 20 18 16 14 12 10 8 6 4 2 Terminal no. 19 17 15 13 11 9 7 5 3 1 15 Wiring Remote I/O Terminal Section 2-3 The Remote I/O Terminal in the table below is recommended for transistor output. Model Specification G7TC-OC08 Common (+) Relays used 8 x G7T-1112S (max. resistive load: 220 VAC, 2A) Note One P7TF-OS08 I/O Terminal and two G7T-1112S Relays may be purchased separately and used. Wiring Diagram External View 24 VDC Wiring to the heater Connector Terminal Block Converter Unit The Connector Terminal Block Converter Units in the table below are recommended for voltage output and current output type. Model External View 16 Terminal screw size XW2B-20G4 M 2.4 XW2B-20G5 M 3.5 Wiring Section 2-3 2-3-3 Data Setting Console Cables Connecting Cable Use the connecting cables in the table below (sold separately) to connect the Unit to the Data Setting Console. Model Cable length (L) C200H-CN225 2m C200H-CN425 4m L 39 17.3 17.5 16.1 10 Connection Precautions 1, 2, 3... 1. Tighten the lock screws after inserting the connector into the Unit. 2. Push the connector firmly into the Data Setting Console until the clips fully lock. 3. Power is supplied through the connecting cable from the Heat/Cool Temperature Control Unit. Nothing appears on the Data Setting Console display if no power is supplied to input terminals A8 and A9 of the Heat/Cool Temperature Control Unit. 4. Install the supplied connector cover when the Data Setting Console is not in use. 17 SECTION 3 Data Setting Console Operation This section provides the basic operating procedures of the Data Setting Console including parameter settings and displays. 3-1 3-2 3-3 3-4 Operating Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Data Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nomenclature and Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3-1 Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3-2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Parameter Displays and Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4-1 Table of Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4-2 How to Display and Set Parameter Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 21 22 22 23 24 24 26 19 Section 3-1 Operating Procedure 3-1 Operating Procedure After preparing the C200H PC, follow the procedure below to use the Heat/Cool Temperature Control Unit. 1, 2, 3... 20 1. Set the switches on the front and rear panels according to the operating conditions. (Refer to 2-2 Switch Settings.) Set SW2-2 under the display cover to the OFF position to enable data setting from the Data Setting Console. 2. Mount to Rack. Turn off the C200H power supply before mounting or dismounting the C200H on the Rack. 3. Connect the input wiring. (Refer to 2-3 Wiring.) The 24-VDC power supply must be connected. The Data Setting Console will not operate unless the 24-VDC power supply is connected. The sensors can be connected immediately before the system is tested. 4. Connect the Data Setting Console. (Refer to 2-3-3 Data Setting Console Cables.) 5. Turn on the 24-VDC and the C200H power supplies. Set the C200H to PROGRAM mode. 6. Use the Data Setting Console to make the settings for the parameters that need to be changed. (Refer to the rest of this section.) 7. Test operation and adjust data. (Refer to the rest of this section.) Connect the output wiring and turn on the heater power. To start the test operation, turn ON the RUN bit of the loop that is to be controlled with a device such as the Programming Console. Monitor the control conditions and adjust the data until the required control is achieved. During operation, the “bank no.” is switched to “executed bank no.” and cannot be changed from the Data Setting Console. To change it, use a device such as the Programming Console, or use the user program. 8. Create the user programs. (Refer to Section 4 PC Memory Allocation and Programming.) Arrange the data for the test operation, and create the user programs for data setting, monitoring, switching the bank number, and so on. Set SW2-2 under the display cover to the ON position to enable data setting from the C200H PC. 9. Start operation. Data Flow 3-2 Section 3-2 Data Flow The data flow in the Heat/Cool Temperature Control Unit is shown in the diagram below. Heating and Cooling Temperature Control Unit Read Write executed bank no. Write C200H PC ON SW2-2 OFF Data Setting Console Read The read operation and setting the executed bank number are possible from a user program or from a device, such as the Programming Console, regardless of the ON/OFF setting of SW2-2. Data written from the Data Setting Console and data written with write command when SW2-1 (switching memory contents) is set to Normal are written to the Heat/Cool Temperature Control Unit EEPROM and are consequently retained when the power supply is turned off. The SP value set when SW2-1 (switching memory contents) is set to Fixed and executed bank number settings made from the C200H PC are written directly to RAM and are not saved to EEPROM. This data is lost when the power supply is turned off. The same data can be written to the RAM when the power is next turned on and executes a user program. Settings made from the Programming Console must be repeated each time the power is turned on. Data Settings from Data Setting Console Set SW2-2 under the display cover to the OFF position to enable data setting from the Data Setting Console. The “bank no.” can be set when operation is stopped (i.e., when the RUN bit is OFF). During operation it is switched to “executed bank no.” and cannot be changed from the Data Setting Console. To change the executed bank number, use a user program or a device such as the Programming Console. Operation begins when the RUN bit of the output relay turns ON. (For information on output relays, refer to Section 4 PC Memory Allocation and Programming.) 21 Nomenclature and Features 3-3 Section 3-3 Nomenclature and Features 3-3-1 Nomenclature Front View Side View Data display Operation indicators Cover Down Key (With cover open) Up Key Display Key Panel mounting bracket (Refer to Appendix D Dimensions for details about panel mounting.) Rear View Operation keys Select parameters Set data Switch Loops Level Key Loop Key Heat/Cool Temperature Control Unit connector Connecting cable (sold separately) C200H-CN225 (2 m) C200H-CN425 (4 m) The bottom row of the operation keys have upper and lower labels. The upper labels apply to Heat/Cool Temperature Control Unit operation. The lower labels are for the Cam Positioner Unit. Two display sheets are supplied: one for the Heat/Cool Temperature Control Unit and one for the Cam Positioner Unit. If the Data Setting Console is to be used with the Temperature Control Unit only, stick on the display sheet for the Heat/Cool Temperature Control Unit. Note The Data Setting Console will not operate unless a 24-VDC power supply is connected to the Heat/Cool Temperature Control Unit input terminals. 22 Nomenclature and Features Section 3-3 3-3-2 Features Data Display Name Function PV (Process Value) Displays the PV or the parameter symbol selected with the Level or Display Key (Refer to next page). SV (Set Value) The display is as follows, according to the PV display contents. BK (Bank Number) PV (process value): SV (set value) is displayed. Parameter symbol: Setting/monitor data is displayed. Displays the bank number of the data presently being displayed. During operation, the executed bank number is displayed. (See note) Note Operation begins when the RUN bit of the output relay turns ON. Operation Indicators Name Function LOOP2 Indicates whether the displayed settings relate to Loop 1 or Loop 2. Press the Loop Key and hold down for approximately 2 seconds to switch between Loop 1 and Loop 2. Indicator OFF: Loop 1 Indicator ON: Loop 2 OUT (Output) Turns ON when the heating output is ON for transistor output or voltage output types. AT (Auto-tuning) Blinks at approximately 1 second intervals during auto-tuning. HB (Heater Burnout) Turns ON to indicate a heater burnout alarm. ALM1 (Alarm) Turns ON to indicate the temperature is in the alarm range set with Alarm SV 1 (upper- and lower-limit alarm). Refer to the following page. These indicators relate to the currently y displayed y l loop. Display Patterns Display Pattern 1 Display Pattern 2 Process value Executed bank number or displayed bank number Parameter symbol SV (Set value) Monitored value Execution status Set point Indicator OFF: Loop 1 Indicator ON: Loop 2 Executed bank number or displayed bank number Indicator OFF: Loop 1 Indicator ON: Loop 2 23 Parameter Displays and Settings Section 3-4 Operation Keys Name 3-4 Function Level Key The parameter items are divided into three display groups (Refer to display levels 0 to 2 on the next page). Press this key to switch from one group to another. The display levels automatically cycle in the sequence 0 –> 1 –> 2 –> 0 when the key is held down for approximately 2 seconds. Display Key Press this key to select the required parameter from the selected display level 0 to 2 (Refer to table below). The parameters cycle automatically when the key is held down. Loop Key Press this key for approximately two seconds to switch between Loop 1 and Loop 2. Up Key Press this key to increment SV. The SV increment continuously while the key is held down. The SV display blinks when the value reaches its upper limit. Down Key Press this key to decrement an SV. The SV decreases continuously while the key is held down. The SV display blinks when the value reaches its lower limit. Parameter Displays and Settings 3-4-1 Table of Parameters Display level 0 Parameter Display symbol Write Read Loop no. Bank no. Data range Default value Page Set point --- Yes Yes Yes Yes SP lower limit to SP upper limit 0°C 26 Bank number bk See note 5 Yes Yes No 1 to 8 1 26 Alarm mode TC 1, 4, 5: 0° to 9999°C Other TCs: 999 to 9999 C –999° 9999°C Pt 1, 4, 5: 0.0° to 999.9°C Other Pts: –99.9° to 999.9°C 0°C 27 Alarm SV 1 (see note 4) al-1 Yes Yes Yes Yes Alarm SV 2 (see note 4) al-2 Yes Yes Yes Yes Input shift value in-5 Yes Yes Yes Yes –99.9° to 999.9°C 0.0°C 27 Proportional band (see note 1) p Yes Yes Yes Yes 0.0° to 999.9°C 40.0°C 27 Integral (reset) time (see note 1) i Yes Yes Yes Yes 0 to 9999 s 240 s Derivative (rate) time (see note 1) d Yes Yes Yes Yes 0 to 9999 s 40 s 0°C 1 SP lower limit sl-l Yes Yes Yes No Sensor measurTC: –200°C ing range lower Pt: –99.9°C limit to (SP upper limit – 1 digit) 28 1 SP upper limit sl-h Yes Yes Yes No (Sensor measuring range lower limit + 1 digit) to SP upper limit 28 24 TC: 1,300°C Pt: 450.0°C Parameter Displays and Settings Display level Parameter Display symbol Section 3-4 Write Read Loop no. Bank no. Data range Default value Page Dead band (see note 1) c-db Yes Yes Yes No TC: –999 to 9999°C Pt: –99.9 to 999.9°C 0°C 28 Cooling coefficient (see note 1) c-sc Yes Yes Yes No 0.01 to 99.99 1.00 29 Heating control period (see notes 1 and 3) cp Yes Yes Yes No 1 to 99 s 20 s 29 Cooling control period (see notes 1 and 3) c-cp Yes Yes Yes No 1 to 99 s 20 s 29 hys Yes Yes Yes Yes 0.0° to 999.9°C 0.8°C 29 hysa Yes Yes Yes No 0.0° to 999.9°C 0.2°C 30 30 Hysteresis (see note 2) Alarm hysteresis (see note 4) Heater current monitor (see note 3) ct No Yes Yes No 0.0 to 55.0 A 0.0 A Heater burnout current (see note 3) hb Yes Yes Yes No 0.0 to 50.0 0.0 A 0.0: No heater burnout detection, alarm signal OFF 50.0: No heater burnout detection, alarm signal ON 2 Heating output variable monitor h-o No Yes Yes No 0.0% to 100.0% 0.0 % 31 Cooling output variable monitor c-o No Yes Yes No 0.0% to 100.0% 0.0 % 31 at Yes Yes Yes No --- --- 31 Copy bank bcpy Yes Yes Yes No --- --- 31 Input-type monitor in-t No Yes No No 0 to 9 Setting for SW202 Alarm 1 mode alt1 Yes Yes Yes No 0 to 9 2 Alarm 2 mode alt2 Yes Yes Yes No Auto-tuning start/ stop (see note 1) 32 2 Yes: Possible. No: Not possible or not required. Note 1. Only when advanced PID control is selected. (switch 203-1 = OFF) 2. Only when ON/OFF control is selected. (switch 203-1 = ON) 3. Valid only for C200H-TV03 (current output type). 4. Does not apply when Alarm Mode = 0. 5. Writing is not possible during operation (i.e., when RUN is ON). 6. Thermocouple = TC Platinum Resistance Thermometer = Pt 25 Parameter Displays and Settings Section 3-4 3-4-2 How to Display and Set Parameter Data Basic Operation When not specifically explained, use the keys as described in the following. Changing the Display Level When the Level Key is pressed, the leading parameter for each level is displayed. Changing Parameters When the Display Key is pressed, the parameters are displayed in order. There may be skips depending on the model and DIP switch settings. Changing the SV Pressing the Up Key or the Down Key changes the SV. The SV is retrieved automatically. Changing the Loop The loop is switched each time the Loop Key is pressed. It can be confirmed by means of the LOOP 2 indicator. PV and SV (Display Level 0) PV Process temperature (monitored every 500 ms) SV Set point of currently selected bank and loop (unit: °C or °F) Valid SV Range Set the set point in the range between the SV lower limit and the SV upper limit. Error Display When a sensor error occurs, one of the codes below and the detected temperature blink alternately in the PV display. ser1 ser2 serr Temperature is out of the range: (sensor measurement range + 10%FS). That is, 10%FS below the lower limit or 10%FS above the upper limit limit. Includes broken or incorrect sensor wiring wiring. ser1: Loop1 or Loop1 and Loop2 simultaneously. ser2: Loop2 Abnormality in the cold junction compensating circuit. Applies to thermocouple type only. Bank Number (Display Level 0) PV Bank number parameter symbol SV Currently set bank number. During control operation: Executed bank number Control operation interrupted: Currently displayed bank number Settings • The bank number can be changed. • The changed SV is reflected in the bank number display (BK). Bank Number and Executed Bank Number The executed bank number cannot be changed from the Data Setting Console. 26 Parameter Displays and Settings Section 3-4 When changing these parameters from the Data Setting Console, stop operation. While operation is stopped, the bank number setting can be changed. Alarm SV 1 (Display Level 0) PV Alarm 1 parameter symbol SV Alarm SV of currently selected bank and loop (unit: °C or °F) Not valid when Alarm mode = 0. Alarm SV 2 (Display Level 0) PV Alarm 2 parameter symbol SV Alarm SV of currently selected bank and loop (unit: °C or °F) Not valid when Alarm mode = 0. Input Shift Value (Display Level 0) PV Input shift value parameter symbol SV Input shift value of currently selected bank and loop (unit: °C or °F) If the displayed temperature value differs from the actual temperature value due to the sensor position or some other conditions, set the input shift value such that the correct temperature is displayed. Proportional Band (Display Level 0) PV Proportional band parameter symbol SV Proportional band of currently selected bank and loop (unit: °C or °F) • This sets the proportional band. It is valid only when SW203-1 is set to OFF (i.e., PID control). • This value is reflected even when auto-tuning (AT) is executed. • If this value is set to “0.0,” ON/OFF control is executed. Integral (Reset) Time (Display Level 0) PV Integral time parameter symbol SV Integral time of currently selected bank and loop (unit: second) • This sets the integral time. It is valid only when SW203-1 is set to OFF (i.e., PID control). • This value is reflected even when auto-tuning (AT) is executed. Derivative (Rate) Time (Display Level 0) PV Derivative time parameter symbol SV Derivative time of currently selected bank and loop (unit: second) 27 Parameter Displays and Settings Section 3-4 • This sets the integral time. It is valid only when SW203-1 is set to OFF (i.e., PID control). • This value is reflected even when auto-tuning (AT) is executed. SP Lower Limit (Display Level 1) PV SP lower limit parameter symbol SV SP lower limit of currently selected loop (unit: °C or °F) • Settings can be made within the following range: Sensor measuring range lower limit to (SP upper limit – 1 digit) • When powering up or starting, the lower limit of the measuring range for sensors set by the rear-panel SW202 (sensor type) is set automatically. For example, if SW202 is set to “2,” the thermocouple type is set to “–200.” However, the SP lower limit will not be changed if the current SV lies inside the sensor measuring range. SP Upper Limit (Display Level 1) PV SP upper limit parameter symbol SV SP upper limit of currently selected loop (unit: °C or °F) • Settings can be made within the following range: (SP limit + 1 digit) to sensor measuring range upper limit • When powering up or starting, the upper limit of the measuring range for sensors set by the rear-panel SW202 (sensor type) is set automatically. For example, if SW202 is set to “2,” the thermocouple type is set to “1300.” However, the SP upper limit will not be changed if the current SV lies inside the sensor measuring range. Dead Band (Display Level 1) PV Dead band parameter symbol SV Dead band of currently selected loop (unit: °C or °F) • This sets the cooling output dead band, and it is valid when SW203-1 (PID control) is OFF. • The relation between the dead band and the set temperature is as shown in the illustration below. Output volume Dead band Heating output Cooling output 100% 0% Temperature Set value 28 Parameter Displays and Settings Section 3-4 Cooling Coefficient (Display Level 1) PV Cooling coefficient parameter symbol SV Cooling coefficient of currently selected loop • This sets the coefficient for finding the cooling P constant. It is valid when SW203-1 is OFF (PID control). The formula for calculating the cooling P constant is as follows: Cooling P constant = heating P constant x cooling coefficient • The I/D constant is the same for cooling as for heating. Control Period (Display Level 1) PV Heating control period parameter symbol SV Heating control period of currently selected loop (Unit: seconds) PV Cooling control period parameter symbol SV Cooling control period of currently selected loop (Unit: seconds) • This sets the control period. It is valid when SW203-1 is OFF (PID control), and only when the heater model is not the C200H-TV03 (current output type). • Cooling loop 1 is invalid when SW203-6 is ON (current output). • The control period is the time required to complete one transistor output or voltage output ON/OFF cycle. ON OFF ON time Control period Hysteresis (Display Level 1) PV Hysteresis parameter symbol SV Hysteresis of currently selected bank and loop (Unit: °C or °F) • Hysteresis prevents control output chattering and eliminates noise influences. • When switching from ON to OFF, operation proceeds at the set point. When switching from OFF to ON, operation proceeds at a lower point determined by the hysteresis SV, as shown in the following illustration. Hysteresis ON OFF Set point 29 Parameter Displays and Settings Section 3-4 Hysteresis is applied in the following situations. • When ON/OFF control is selected (i.e., when SW203-1 is ON). • When advanced PID control is selected (i.e., when SW203-1 is OFF) and P (proportional band) is 0. Alarm Hysteresis (Display Level 1) PV Alarm hysteresis parameter symbol Alarm hysteresis of currently selected loop (Unit: °C or °F) SV • Alarm hysteresis prevents alarm output chattering and eliminates noise influences. It is invalid when both alarm mode 1 and alarm mode 2 are “0.” • When switching from OFF to ON, operation proceeds at the set point. When switching from ON to OFF, a hysteresis SV operating band is provided which may be either higher or lower than the set point, depending on the alarm mode. Upper Limit Mode Lower Limit Mode Hysteresis Hysteresis ON ON OFF OFF Set point Set point The alarm output is OFF if the present temperature lies within the hysteresis band when the Unit is turned on. Heater Current Monitor (Display Level 1) PV Heater current monitor parameter symbol Heater current of currently selected loop (Unit: Ampere). Monitored every 500 ms. SV Note Cannot be set. • Valid for C200H-TV03 (current output type). Heater Burnout Detection Current (Display Level 1) PV Heater burnout detection current parameter symbol SV Heater burnout detection current of currently selected loop (Unit: Ampere) The setting can be changed from this display. • Invalid for C200H-TV03 (current output type). • Make the setting using one of the two values shown in the table below. Refer to Appendix C Heater Burnout Detection for more details about the alarm SVs. 30 0.0 No heater burnout detection. Alarm signal OFF. 50.0 No heater burnout detection. Alarm signal ON. Parameter Displays and Settings Section 3-4 Control Output Variable Monitor (Display Level 2) PV Heating control output variable monitor parameter symbol SV Heating output variable of currently selected loop (Unit: %). Monitored every 500 ms. PV Cooling control output variable monitor parameter symbol SV Cooling output variable of currently selected loop (Unit: %). Monitored every 500 ms. The relationship between the control output variable and control period is defined by the formula below: ON time Control output variable (%) = x 100 Control period The control output variable during ON/OFF control (when SW203-1 on the rear panel is ON) is ON = 100% and OFF = 0%. Auto-tuning Start/Stop (Display Level 2) PV Process temperature SV Set point AT start/stop parameter symbol AT indicator blinks • The auto-tuning operation begins when the Up Key is pressed. The PV and SV return to the respective present temperature and set point displays. While auto-tuning is in progress the AT indicator blinks. • To interrupt, press the Level and Display Keys again to display at. When at appears, press the Up Key. When the interrupt is executed, the AT display disappears and the process temperature is displayed. • When auto-tuning is completed, the AT indicator stops blinking and the P, I, and D data is written to EEPROM. Copy Bank (Display Level 2) PV SV Copy bank parameter symbol Execute bank copy Bank being copied Bank copy completed • When the Up Key is pressed, the data other than the set point is copied from bank number 1 to banks 2 through 8. • Use this method to create data in banks 2 through 8 by slightly modifying the data in bank number 1. Input-type Monitor (Display Level 2) PV Input-type monitor parameter symbol SV Input type currently set with SW202 on the rear panel. Thermocouple: Setting no. Platinum resistance thermometer: 0: JPt (OFF), 1: Pt (ON) Note Cannot be set. 31 Parameter Displays and Settings Section 3-4 Alarm 1 and Alarm 2 Modes (Display Level 2) PV Alarm 1 Mode parameter symbol SV Alarm 1 Mode of currently selected loop PV Alarm 2 Mode parameter symbol SV Alarm 2 Mode of currently selected loop Select the desired alarm type from the following chart and set the number (X: set value) Alarm Mode Alarm Type Alarm Range SP 0 0 No alarm 1 Upper- and lower-limit alarm 2 Upper-limit alarm 3 Lower-limit alarm x 4 Upper- and lower-limit range alarm x x 5 Upper- and lower-limit alarm with standby sequence x x 6 Upper-limit alarm with standby sequence 7 Lower-limit alarm with standby sequence 8 Absolute-value upper-limit alarm 9 Absolute-value lower-limit alarm x x x x x x x Standby Sequence When the power is turned on, the temperature is below the set point, so alarm output status occurs with regard to the lower limit alarm. In this situation, if “lower limit alarm with standby sequence” is selected, the standby sequence recognizes that the value is out of the alarm range and then outputs an alarm when the value enters the alarm range once more. 32 Parameter Displays and Settings Section 3-4 Lower Limit Alarm with Standby Sequence Standby sequence cancel point Hysteresis OFF point Alarm SV 0°C Alarm output The standby sequence is restarted in the following situations. • When the power is turned on. • When the set point is changed. • When the executed bank number is changed. • When the alarm mode is changed. • When changing from stop to run. 33 SECTION 4 PC Memory Allocation and Programming This section provides the C200H PC’s memory allocation for the Heat/Cool Temperature Control Unit. Basic programming procedures and examples are also provided. 4-1 4-2 4-3 Memory Allocation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1-1 Memory Allocation Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1-2 Memory Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1-3 Table of Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Data Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3-1 Example with SW2-1 in the Fixed Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3-2 Example 1: Write with SW2-1 in the Normal Position . . . . . . . . . . . . . . . . . . . . . 4-3-3 Example 2: Read with SW2-1 in the Normal Position . . . . . . . . . . . . . . . . . . . . . 4-3-4 Operation Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 37 38 41 43 43 43 44 47 50 35 Section 4-1 Memory Allocation 4-1 Memory Allocation Memory Allocation According to the Unit number switch setting on the front of the C200H Heat/Cool Temperature Control Unit, 10 words are allocated for each Unit number in the Special I/O Unit IR area between IR100 to IR199, which is used as the I/O refresh data area. The IR area used by the C200H Temperature Control Unit is refreshed on each C200H PC I/O refresh cycle. Heat/Cool Temperature Control Unit C200H PC IR area I/O refresh data area Unit#0 IR100 to IR109 OUT Unit#1 IR110 to IR119 Unit#2 IR120 to IR129 IN Unit#3 IR130 to IR139 Unit#4 IR140 to IR149 Unit#5 IR150 to IR159 Unit#6 IR160 to IR169 Unit#7 IR170 to IR179 Unit#8 IR180 to IR189 Unit#9 IR190 to IR199 During the PC’s I/O refresh, each cycle is executed for the outputs (PC to Heat/Cool Temperature Control Unit) followed by the inputs (Heat/ Cool Temperature Control Unit to PC). Wd (n) Output to refresh Wd (n+2) Wd (n+3) Input to refresh Wd (n+9) (n=100 + 10 x Unit number) The terms “output” and “input” are defined from the C200H PC side. Note A Duplicate I/O Unit error occurs if the set Unit number corresponds to the number of an existing Special I/O Unit. Selecting Allocated Data The data allocated to each IR word due to the Unit number setting is determined by the setting of SW2-1 on the front of the Unit. ON Normal All data can be set using commands. OFF Fixed Parameters are fixed for the set point (SP). This setting becomes valid immediately when the switch is set. 36 Section 4-1 Memory Allocation 4-1-1 Memory Allocation Table SW2-1 in Fixed Position (n=100 + 10 x Unit number) I/O Bit Word 15 Output n 14 13 12 n+2 Input n+3 n+7 n+8 06 05 04 03 02 0 to 9 0 to 9, F 0 to 9 0 to 9 0 to 9 Loop 1 executed bank number b Loop 2 executed bank number b Loop 1 01 00 0 to 9 0 to 9 0 to 9 0 to 9 0 to 9 0 to 9 0 to 9 0 to 9 0 to 9 0 to 9, F 0 to 9 0 to 9 0 to 9 Loop 1 executed bank number b Loop 2 executed bank number b 0 0 0 RUN 0 0 Coo ling output Hea AT ting output 0 RUN 0 0 Coo ling output Hea AT ting output Loop 2 RUN 0 0 RUN 0 0 Loop 1 PV (see note) Loop 2 PV (see note) Loop 1 SP (see note) Loop 2 SP (see note) 0 SW2 2 1 HB AL1 AL2 HB AL1 AL2 Loop 1 status data 0 n+9 07 0 to 9 0 to 9, F n+6 08 0 to 9 0 to 9, F n+5 09 Loop 2 SP (see note) 0 to 9, F n+4 10 Loop 1 SP (see note) 0 to 9, F n+1 11 Sensor error CT 0 overflow Loop 2 status data 0 Sensor error CT 0 overflow Note For four-digit BCD and platinum resistance thermometer data, the least significant digit = 0.1, and the most significant digit (F) = minus (–). For example, “F200” represents –20.0°C for a platinum resistance thermometer. SW2-1 in Normal Position (n=100 + 10 x Unit number) I/O Bit Word 15 Output n 14 n+2 Input n+3 12 11 10 09 08 07 06 05 04 03 02 01 00 Read/write instruction Read/write n+1 13 Loop no. Bank no. Instruction 0 to 9, F 0 to 9 0 to 9 Loop 1 executed bank number Loop 2 executed bank number 0 0 to 9 0 to 9 Write data (see note) 0 to 9 Loop 1 RUN 0 Loop 2 0 RUN 0 0 Write request Loop 1 PV (see note) 0 to 9, F 0 to 9 37 Section 4-1 Memory Allocation I/O Word Bit 15 Input n+4 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00 Loop 2 PV (see note) 0 to 9, F 0 to 9 0 to 9 0 to 9 0 to 9, F 0 to 9 0 to 9 0 to 9 n+6 0 Write 0 error n+7 Loop 1 executed bank number b Loop 2 executed bank number b 0 n+8 Loop 1 status data 0 RUN 0 0 Co oling output Heat- AT ing output 0 RUN 0 0 Co oling output Heat- AT ing output n+5 Read data (see note) 0 n+9 Sensor error CT 0 overflow 0 Write 0 complete 0 0 0 0 0 SW2 Read complete 2 1 HB AL1 AL2 HB AL1 AL2 Loop 2 status data 0 Sensor error CT 0 overflow Note For four-digit BCD and platinum resistance thermometer data, the least significant digit = 0.1, and the most significant digit (F) = minus (–). For example, “1000” represents 100.0°C for a platinum resistance thermometer. 4-1-2 Memory Contents SW2-1 in Fixed Position (n=100 + 10 x Unit number) I/O Address Word Output 38 Data item Data contents Sets the Loop 1 and Loop 2 SP (set point) as 4-digit BCD data. For platinum resistance thermometer data, the least significant 1 Set the most significant digit to F for minus (–) digit is 0 0.1. (–). Note These specified values apply to the bank number set with Wd (n+2) and can are written directly to RAM. (Refer page 43) Bit n 15 to 00 Loop 1 SP n+1 15 to 00 Loop 2 SP n+2 15 to 12 Loop 1 executed bank number 11 to 08 Loop 2 executed bank number 07 --- Not used. Set to 0. 06 Loop 1 RUN This the Loop 1 Run/Stop bit. When it is set to 1, operation starts; when it is set to 0, operation stops. 05 --- Not used. Set to 0. 04 Loop 2 RUN This the Loop 2 Run/Stop bit. When it is set to 1, operation starts; when it is set to 0, operation stops. 03 to 00 --- Not used. Set to 0. Sets the bank number executed for Loop 1 and Loop 2 as 1-digit BCD data. Set executed bank numbers from 1 to 8. If the value is set out of this range, the bank number reverts to the previous value. Section 4-1 Memory Allocation I/O Address Word Input Data item Data contents Outputs the Loop 1 and Loop 2 PV (process value) as 4-digit BCD data data. For platinum resistance thermometer data data, the least significant digit is 0.1. The most significant digit is F for minus (–). Bit n+3 15 to 00 Loop 1 PV n+4 15 to 00 Loop 2 PV n+5 15 to 00 Loop 1 SP n+6 15 to 00 Loop 2 SP n+7 15 to 12 Loop 1 executed bank number 11 to 08 Loop 2 executed bank number 07 to 02 --- Not used. Each bit is set to 0. 01 SW2-2 Outputs the ON/OFF status of SW2-2 (setting direction). 0: Data Setting Console 1: C200H PC 00 SW2-1 Outputs the ON/OFF status of SW2-1 (switching memory contents). 0: Fixed 1: Normal --- Not used. Set to 0. 14 Sensor error Bit set to 1 if the sensor is not connected, a sensor wire is broken, or the input data exceeds the operational temperature range. 13 CT overflow Bit set to 1 when the detected heater current exceeds 55.0 A. 12 to 09 --- Not used. Each bit is set to 0. 08 RUN Bit set to 1 during operation. 07 and 06 --- Not used. Each bit is set to 0. 05 Cooling control output Bit set to 1 when the control output (transistor or voltage output) is ON. 04 Heating control output 03 AT Bit set to 1 during auto-tuning (AT). 02 HB Bit set to 1 if the detected heater current drops below the set heater burnout current value. (HB: heater burnout) 01 AL1 00 AL2 Bit set to 1 when the temperature enters the set alarm l range (Refer (R f to t page 23). 23) n+8 Loop 1 15 n+9 Loop 2 Outputs the Loop 1 and Loop 2 SP (set point) as 4-digit BCD data For platinum resistance thermometer data data. data, the least significant digit is 0.1. The most significant digit is F for minus (–). Outputs the bank number currently executed for Loop 1 and Loop 2 as 1-digit BCD data. Loop 1/2 status data Note If the setting direction of the Temperature Control Unit is set to the C200H PC and the C200H is in program mode, all word data will be 0. Therefore, if the C200H in program mode has been set to continuous control, the Temperature Control Unit executes temperature control when the C200H stops operating, judging that the SP has been changed to 0°C. To prevent this, set SW2-2 of the Temperature Control Unit to OFF (i.e., the setting direction is set to the Data Setting Console) before the C200H stops operating and reset SW2-2 after the C200H restarts. 39 Section 4-1 Memory Allocation SW2-1 in Normal Position (n=100 + 10 x Unit number) I/O Address Word Output Input 40 n Data item Data contents Bit 15 and 14 Read/Write The data bit sets operation to read or write. Write = 01 Read = 00 Read/Write command 13 and 12 Loop no. The data bit sets the Loop Number to which the read or write operation applies. Loop 1 = 01, Loop 2 = 10 11 to 08 Bank no. Sets the bank number to which the read or write operation applies as 1-digit BCD data. Set executed bank numbers from 1 to 8. 07 to 00 Command Sets the command code (Refer to page 41) for the read or write operation as 2-digit BCD data. n+1 15 to 00 Write data Set the SP for a write operation as 4-digit BCD data. The least significant digit of the actual data matches the least significant digit of the set value. Set the most significant digit to F for minus (–) values. The write operation commences when the write request flag (Wd (n+2), bit 00) turns ON. n+2 15 to 12 Loop 1 executed bank number Set the bank number currently executed for Loop 1 and Loop 2 as 1-digit BCD data. Executed bank numbers are from 1 to 8. If the value is set out of this range, the bank number reverts to the previous value. 11 to 08 Loop 2 executed bank number 07 --- Not used. Set to 0. 06 Loop 1 RUN This the Loop 1 Run/Stop bit. When it is set to 1, operation starts; when it is set to 0, operation stops. 05 --- Not used. Set to 0. 04 Loop 2 RUN This the Loop 2 Run/Stop bit. When it is set to 1, operation starts; when it is set to 0, operation stops. 03 to 01 --- Not used. Set to 0. 00 Write request Turn this bit ON to write the data in Wd (n+1), by means of this command. Turn this bit OFF after the Write Complete Flag (Wd (n+6), bit 08) turns ON. n+3 15 to 00 Loop 1 PV n+4 15 to 00 Loop 2 PV Outputs the Loop 1 and Loop 2 PV (process value) as 4-digit BCD data. For platinum latinum resistance thermometer data, the least significant digit is 0.1. Set the most significant digit to F for minus (–) values. n+5 15 to 00 Read data Outputs the data read with the commands set with Wd (n). The least significant digit of the actual data matches the least significant digit of the set value. Set the most significant digit to F for minus (–) values. n+6 15 to 12 --- Not used. Each bit is set to 0. 11 Write error Bit set to 1 when the write data exceeds the set permissible range. The bit is automatically set to 0 when the Write Request Flag (Wd (n+2), bit 00) turns OFF. 10 and 09 --- Not used. Each bit is set to 0. 08 Write complete Bit set to 1 when the write operation executed by means of the command set with Wd (n) ends normally. The bit is automatically set to 0 when the Write Request Flag (Wd (n+2), bit 00) turns OFF. Read/Write command Section 4-1 Memory Allocation I/O Address Word Input n+6 n+7 Data item Data contents Bit 07 to 01 --- Not used. Each bit is set to 0. 00 Read complete Bit set to 1 when the read operation executed by means of the command set with Wd (n) ends normally. The bit is automatically set to 0 when the next command is set. 15 to 12 Loop 1 executed bank number Outputs the bank number currently executed for Loop 1 and Loop 2 as 1-digit BCD data. 11 to 08 Loop 2 executed bank number 07 to 02 --- Not used. Each bit is set to 0. 01 SW2-2 Outputs the ON/OFF status of SW2-2 (setting direction). 0: Data Setting Console 1: C200H PC 00 SW2-1 Outputs the ON/OFF status of SW2-1 (switching memory contents). 0: Fixed 1: Normal --- Not used. Set to 0. Sensor error Bit set to 1 if the sensor is not connected, a sensor wire is broken, or the input data exceeds the operational temperature range. 13 CT overflow Bit set to 1 when the detected heater current exceeds 55.0 A. 12 to 09 --- Not used. Each bit is set to 0. 08 RUN Bit set to 1 during operation. 07 and 06 --- Not used. Each bit is set to 0. 05 Cooling control output Bit set to 1 when the control output (transistor or voltage output) is ON. 04 Heating control output 03 AT Bit set to 1 during auto-tuning (AT). 02 HB Bit set to 1 if the detected heater current drops below the set heater burnout current value. (HB: heater burnout) 01 AL1 00 AL2 Bit set to 1 when the temperature enters the set l (R f to t page 23). 23) alarm range (Refer n+8 Loop 1 15 n+9 9L Loop 2 14 Loop 1/2 status t t d data t 4-1-3 Table of Commands The command codes shown below are set in bits (n Wd) 07 to 00 when the SW2-1 (switching memory contents) on the front panel is set in the Normal position. Parameter Command Write Read Loop no. Bank no. Actual data range Write/Read data range Default value Set point 0 0 Yes Yes Yes Yes SV lower limit to SV upper limit 0°C Executed bank number 0 2 Yes Yes Yes No 1 to 8 1 0001 to 0008 41 Section 4-1 Memory Allocation Parameter Command Write Read Loop no. Bank no. Actual data range Write/Read data range Default value Alarm mode TC 1, 4, 5: 0 to 9999°C Other TCs: –999 to 9999°C Pt 1, 4, 5: 0.0 to 999.9°C Other Pts: –99.9 to 999.9°C 0000 to 9999 F999 to 9999 Yes –99.9 to 999.9°C F999 to 9999 Yes Yes 0.0 to 999.9°C 0000 to 9999 40.0°C Yes Yes Yes 0 to 9999 s 0000 to 9999 240 s Yes Yes Yes Yes 0 to 9999 s 0000 to 9999 40 s 0 Yes Yes Yes No Sensor measuring range lower limit to (SP upper limit value – 1 digit) TC: –200°C Pt: –99.9°C 1 1 Yes Yes Yes No (SP lower limit + 1 digit) to sensor measuring range upper limit TC: 1,300°C Pt: 450.0°C Dead band (see note 1) 1 C Yes Yes Yes No TC: –999 to 9999°C Pt: –99.9 to 999.9°C F999 to 9999 0°C Cooling coefficient (see note 1) 1 D Yes Yes Yes No 0.01 to 99.99 0001 to 9999 1.00 Heating control period (see notes 1 and 3) 1 7 Yes Yes Yes No 1 to 99 s 0001 to 99 20 s Cooling control period (see notes 1 and 3) 1 6 Yes Yes Yes No 1 to 99 s 0001 to 99 20 s Hysteresis (see note 2) 1 8 Yes Yes Yes Yes 0.0 to 999.9°C 0000 to 9999 0.8°C Alarm hysteresis (see note 4) 1 9 Yes Yes Yes No 0.0 to 999.9°C 0000 to 9999 0.2°C Heater current monitor (see note 3) 1 A No Yes Yes No 0.0 to 55.0 A 0000 to 0550 0.0 A Heater burnout current ((see note 3)) 1 B Yes Yes Yes No 0.0 to 50.0 A 0000 to 0050 0.0 A Alarm SV 1 (see note 4) 0 3 Yes Yes Yes Yes Alarm SV 2 (see note 4) 0 4 Yes Yes Yes Yes Input shift value 0 5 Yes Yes Yes Proportional band (see note 1) 0 6 Yes Yes Integral (reset) time (see note 1) 0 7 Yes Derivative (rate) time (see note 1) 0 8 SP lower limit 1 SP upper limit 0°C 0°C 0.0°C 0.0: No heater burnout detection, alarm signal OFF 50.0: No heater burnout detection, alarm signal ON Heating control output variable monitor 2 0 No Yes Yes No 0.0 to 100.0% 0000 to 1000 0.0% Cooling control output variable monitor 2 6 No Yes Yes No 0.0 to 100.0% 0000 to 1000 0.0% Auto-tuning start/stop (see note 1) 2 1 Yes No Yes No --- Start = 0001 Stop = 0000 --- Copy bank 2 2 Yes No Yes No --- 0001 --- Input-type monitor 2 3 No Yes No No 0 to 9 0000 to 0009 Setting for SW202 42 Programming Section 4-3 Parameter Command Alarm 1 mode 2 4 Alarm 2 mode 2 5 Write Read Yes Yes Loop no. Yes Bank no. No Actual data range 0 to 9 Write/Read data range 0000 to 0009 Default value 2 Yes: Possible. No: Not possible or not required. Note 4-2 1. 2. 3. 4. 5. Only when advanced PID control is selected. (switch 203-1 = OFF) Only when ON/OFF control is selected. (switch 203-1 = ON) Invalid only for C200H-TV03 (current output type). Does not apply when Alarm Mode = 0. Thermocouple = TC Platinum Resistance Thermometer = Pt Data Flow Refer to 3-2 Data Flow for the data flow in the Heat/Cool Temperature Control Unit. Data Settings 4-3 Before setting data with a user program or the Programming Console, turn ON SW2-2 of the Unit to enable data setting from the C200H PC. However, the executed bank number can be set with a user program or from the Programming Console regardless of the ON/OFF setting of SW2-2. SW2-1 (switching memory contents) may be set in either the OFF (Fixed) or ON (Normal) position, but care is required as the setting of this switch changes the stored data contents. Programming 4-3-1 Example with SW2-1 in the Fixed Position Description and Conditions Example: The user program makes the following settings: Loop 1 SP = 80°C Loop 2 SP = 200°C Loop 1 executed bank number = 1 Loop 2 executed bank number = 3 Conditions: C200H-TV001 (thermocouple) SW203 set to 2 (K). Unit number set to 0 (allocated memory: IR100 to IR109). SW2-1 set OFF (Fixed) and SW2-2 set ON (C200H PC). Sample Program 23515 10701 10700 (C200H) Fixed Set #0080 for word 100 (Loop 1 SP). MOV (21) 1 cycle ON #0080 100 Set #0200 for word 101 (Loop 2 SP). MOV (21) #0200 101 Set #1350 for word 102 (executed bank number). MOV (21) #1350 102 END (01) Loop 1, loop 2 begin operation #1350 run bit ON Loop 2 executed bank number Loop 1 executed bank number 43 Programming Section 4-3 Be sure to set the correct values for the Loop 1 and Loop 2 SP. The SV value is #0000 (0°C) if no data is set. If the executed bank number is set to a value out of the range from 1 to 8 the bank number reverts to the previous value (default value = 1). Reading Monitored Data Read monitored data into the program using Wd (n+3) to (n+9). 4-3-2 Example 1: Write with SW2-1 in the Normal Position Description and Conditions Example The user program makes the following settings: Loop 1 SP = 200°C (Bank no. = 1) Loop 2 SP = 250°C (Bank no. = 2) Loop 1 executed bank number = 1 Loop 2 executed bank number = 2 Loop 1 heater burnout current value = 2.0 A Loop 2 heater burnout current value = 2.5 A Conditions C200H-TV001 (thermocouple) SW203 set to 2 (K). Unit number set to 0 (allocated memory: IR100 to IR109). SW2-1 set ON (Normal) and SW2-2 set ON (C200H PC). 44 Programming Section 4-3 Sample Program 10701 10700 DIFU (13) Normal (C200H) 25315 10701 23200 10700 23201 1 cycle ON (C200H) SW2-2 (10701) switch ON detection (C200H PC) Program runs when operation is started or SW2-2 turned ON Normal 23200 23201 MOV (21) #1250 #1250 Loop 1, loop 2 begin operation Loop 2 executed bank number Loop 1 executed bank number 102 MOV (21) #5100 #5100 SP setting instruction Bank number Bit data : 0101 100 MOV (21) #0200 101 Write data (200°C) Loop 1 Write 23202 DIFD (14) 23203 23201 Waits for write completion, then proceeds to next step. S KEEP(11) 23202 10608 Write complete R 23203 #6200 MOV (21) SP setting instruction Bank number Bit data: 0110 #6200 100 MOV (21) Loop 2 Write #0250 101 23204 Write data (250°C) DIFD (14) 23205 23203 10608 S Write complete KEEP(11) 23204 Waits for write completion, then proceeds to next step. R 23205 #501B MOV (21) #501B 100 MOV (21) #0020 Next page 101 Heater burnout current value command Bank number not required Bit data: 0101 Loop 1 Write Write data (2A) 45 Programming Section 4-3 23206 DIFD (14) 23207 23205 10608 S Write complete KEEP(11) 23206 Waits for write completion, then proceeds to next step. R 23207 #601B MOV (21) #601B 100 MOV (21) #0025 101 23201 S 23203 23205 23207 10608 Write complete R END (01) 46 KEEP(11) 10200 Heater burnout current value command Bank number not required Bit data: 0110 Loop 2 Write Write data (2.5A) Write request Programming Section 4-3 Timing Chart 1 cycle 25315 (1 cycle ON) 23201 23202 23203 23204 23205 23206 23207 10200 (Write request) 10608 (Write complete) j: Point of Write command execution In addition to the timing above, 23201 turns ON for one cycle on the ON rising edge of SW2-2 (10701). 4-3-3 Example 2: Read with SW2-1 in the Normal Position Description and Conditions Example: The following data is read from the indicated addresses: Loop 1 PV: DM0000 Loop 1 heating control output variable: DM0001 Loop 2 heater current: DM0002 This read program is to be executed after writing the data with program example 1. Conditions: C200H-TV001 (thermocouple) SW203 set to 2 (K). Unit number set to 0 (allocated memory: IR100 to IR109. SW2-1 set ON (Normal) and SW2-2 set ON (C200H PC). 47 Programming Section 4-3 Sample Program Insert the program below before the END instruction in the program on page 46. 25313 MOV (21) Normally ON 103 Read Loop 1 PV from IR103 to DM 0000. Read operation is not affected by SW2-1 and SW2-2 settings. DM0000 23208 DIFD (14) 23300 23207 S KEEP(11) 23208 (A) 10608 Write complete 23300 10701 R 10700 23301 (C200H) Runs next Read command when final write complete is detected. Normal 23307 repeatedly executes the Read command when each Read Complete is detected. 23307 23301 MOV (21) #1020 100 DIFD (14) 23302 KEEP(11) 23303 Read complete R 23303 DIFD (14) 23304 Next page 48 Heating control output variable monitor command Bank number not required Bit data: 0001 Loop 1 Read S 23302 10600 #1020 Wait for Read Complete to read data Programming Section 4-3 23304 Read data from IR105 to DM 0001. MOV (21) 105 DM0001 MOV (21) #201A 100 DIFD (14) 23305 Execute next Read command. Heater Current #201A Monitor command Bank number not required Bit data 0010 Loop 2 Read S 23305 KEEP(11) 23306 10600 Read complete Wait for Read Complete to read data R 23306 DIFD (14) 23307 23307 MOV (21) 105 Read data from IR105 to DM 0002. DM0002 (B) Change the above program as shown below if only reading is to be carried out. Replace part (A) of the program with the following program. 10701 10700 DIFU (13) (C200H) Normal 25315 10701 23200 SW2-2 (10701) switch ON detection (C200H PC) 10700 23300 1 cycle (C200H) Normal ON Program runs when operation is started or SW2-2 turned ON 23200 Add an END instruction (01) at position (B) of the program. 49 Programming Section 4-3 Timing Chart 1 cycle 23301 23302 23303 23304 23305 23306 23307 Wd 105 (Read data) 10600 (Read complete) : Point of Read command execution 1 : Point where data (1) is read. 2 : Point where data (2) is read. 4-3-4 Operation Timing Write Operation Timing Command (Wd n) Write data (Wd n+1) Data (1) Data (2) Data (3) Data (4) ON Write request (Wd n+2), bit 00 Write complete (Wd n+2), bit 08 OFF ON OFF Approx. 140 ms 1, 2, 3... 50 1. The data is written to the Heat/Cool Temperature Control Unit EEPROM when the Write Request Flag turns ON. 2. The Write Complete Flag turns ON when the data writing operation is completed. It takes approximately 140 ms to write the data. 3. The Write Complete Flag automatically turns OFF when the Write Request Flag turns OFF. Check the Write Complete Flag is ON before turning OFF the Write Request Flag. If the Write Request Flag is set to OFF before the Write Complete Flag turns ON the Write Complete Flag will not subsequently turn ON. Temporarily turn the Write Request Flag OFF before executing the second and subsequent write operations. Writing is enabled on the ON rising edge of the Write Request Flag. Programming Section 4-3 The Loop 1 and 2 executed bank number (Wd n+2) sets data directly. The data is written to the Heat/Cool Temperature Control Unit RAM. If the value is set out of this range, the bank number reverts to the previous value (default value = 1). Timing for a Read Operation Command (A) Command (n) Read complete (Wd n+6), bit 00 Command (B) ON OFF Approx. 140 ms Read data (Wd n+5) 1, 2, 3... I/O Refresh Read data (A) Read data (B) 1. The read data is output to Wd (n+5) approximately 140 ms after the Read command is executed. 2. The read data is updated every 100 ms. 3. When the Read command is modified, turn OFF the Read Complete Flag to execute the next read operation. Heating and cooling control will not be executed properly unless there are at least 8 ms between I/O refresh operations. When creating the program, be sure that all of the conditions described below are satisfied. • The cycle time must be a minimum of 8 ms. If the program processing time is short, it is recommended that the fixed cycle time instruction, SCAN(18), be used. • When IORF(97) is executed for the Temperature Control Unit, there must be an interval of at least 8 ms between prior and subsequent end refreshes. • The time interval for executing IORF(97) must be a minimum of 8 ms. Normal I/O refresh (End refresh) Normal I/O refresh (End refresh) 8 ms min. (cycle time) 8 ms min. IORF(97) (I/O refresh instruction) IORF(97) (I/O refresh instruction) 8 ms min. 8 ms min. Normal I/O refresh (End refresh) 51 SECTION 5 Troubleshooting This section provides possible errors and error remedies. Error Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 53 Section 5 Error Detection Error Detection When an error occurs in an input or in the Unit, details of the error are output to the Data Setting Console and input relays (words n+8 and n+9). Sensor Input Errors The following table shows the Data Setting Console display and error contents. Display ser1 ser2 Error name Loop 1 sensor error Loop 2 sensor error Output status after error Cause Remedy Control output: The transistor output or voltage output turns OFF or the current output falls below 2 mA. Reading is + 10%FS out of sensor measurement range (i.e., 10%FS below the lower limit or 10%FS above the upper limit). Check the sensor wiring. Alarm output: The alarm is output out ut assuming the input is +10%FS. Replace the sensor. Replace the Unit. Correctly set switch SW203-4. input Broken or incorrect in ut wiring Defective input sensor Defective Unit SW203-4 is OFF (Loop 2 enabled) but no sensor connected to Loop 2 serr Cold junction compensating circuit error (C200H-TC00) Data Setting Console Control output: Abnormality in cold The transistor output or junction compensating voltage output turns OFF circuit. or the current output falls below 2 mA. Replace the Unit. When a sensor error occurs, one of the codes above and the detected temperature are displayed alternately. If a Loop 1 sensor error ser1 and a Loop 2 sensor error ser2 occur simultaneously, ser1 is displayed preferentially. Even if a sensor error is detected in one Loop, the other Loop continues to operate normally. Control operation restarts automatically five seconds after the cause of the error is corrected. If a cold junction compensating circuit error occurs, reset the power supply. The following bits are set when a sensor input error occurs. Loop 1 sensor error Wd. n+8, bit 14 = 1; Wd. n+9, bit 14 = 0 Loop 2 sensor error Wd. n+8, bit 14 = 0; Wd. n+9, bit 14 = 1 Cold junction compensating circuit error Wd. n+8, bit 14 = 1; Wd. n+9, bit 14 = 1 CT Input Overflow Display ct ffff Error name CT input overflow Cause The detected heater current exceeds 55.0 A. Remedy Check the CT and heater wiring. The information is displayed as heater current monitor data. It cannot be checked while other parameter data is being displayed. The display returns to normal after the cause of the error is removed. The following bits are set when a CT overflow error occurs. 54 Wd (n+8), bit 13 = 1 Loop 1 CT overflow Wd (n+9), bit 13 = 1 Loop 2 CT overflow Section 5 Error Detection Heater Burnout Alarm Display HB indicator lit Error name Heater burnout Cause Remedy The detected heater current is below the heater burnout current value. Check the heater and heater wiring. Replace heater if necessary. Error displayed when an abnormality occurs in the loop currently being displayed. The following bits are set when a heater burnout alarm occurs. Wd (n+8), bit 02 = 1 Loop 1 heater burnout alarm Wd (n+9), bit 02 = 1 Loop 2 heater burnout alarm Use one of the methods below to reset a heater burnout alarm. a) Turn the Special I/O Unit restart flag (AR0100 to AR0109) ON and then back OFF. b) Turn the C200H power supply OFF then back ON. c) Set the heater burnout current limit to 00 then back to its original value. Temperature Alarm Display Error name Cause Remedy ALM1 indicator lit Temperature alarm 1 The temperature is in the alarm range set with Alarm 1 SV. ––– Temperature alarm 2 The temperature is in the alarm range set with Alarm 2 SV. Check the controlled conditions “ALM1” displays the temperature alarm 1 for the loop current selected. No indicator is provided to show an ALM2 alarm. The bits shown in the table below are set to 1 when a temperature alarm occurs. Wd (n+8) Wd (n+9) Bit 01 =1 Temperature alarm 1 Bit 00 =1 Temperature alarm 2 Bit 01 =1 Temperature alarm 1 Bit 00 =1 Temperature alarm 2 Loop 1 Loop 2 EEPROM Error Display e111 Error name EEPROM error Output status after error Cause Control output: The transistor output or voltage output is OFF or the current output is less than 2 mA. Defective EEPROM Remedy Replace the Unit Alarm output is OFF. The RUN indicator turns off when an EEPROM error occurs. Duplicate I/O Unit The Unit number duplicates the number of another Special I/O Unit. The SR bit 25415 turns ON when an Duplicate I/O Unit error occurs. Refer to AR0000 to AR0011 for the duplicated Unit number. The C200H PC will not operate during a duplicate I/O error. Set the Unit number to a separate number. Special I/O Unit Error I/O refresh not operating correctly between the CPU Unit and Temperature Control Unit. The Heat/Cool Temperature Control Unit is operating based on the con- 55 Error Detection Section 5 tents of the previous refresh. Refer to AR0000 to AR0015 for the Unit number where the error occurred. After correcting the cause of the error, set the Special I/O Unit Restart Flag (AR0100 to AR0109) to restart operation. RUN Indicator Unlit The C200H power supply is turned on but the RUN indicator is not lit. None of the errors described previously are detected. Replace the Unit. No Data Setting Console Display • No 24 VDC power supply is connected to the Heat/Cool Temperature Control Unit input terminals A8 and A9. • The connecting cable is disconnected. • The connecting cable is broken. • A circuit in the Data Setting Console is defective. • A circuit in the Heat/Cool Temperature Control Unit is defective. After determining the cause of the error, correct the problem or replace the Unit. 56 Appendix A Specifications General Specifications Conforms to the C200H PC specifications. Item C200H-TV00 C200H-TV10 Connectable temperature sensor (see note 1) Thermocouple (R, S, K, J, T, E, B, N, L, U) Platinum resistance thermometer (JPt100, Pt100) Current Transformer detection current 0.1 to 49.9 A (with a heater burnout detecting current difference of 2.5 A min.) Indication accuracy: ±5% FS ±1 digit max. No. of input points (loops) Two points (two loops, each of which consists of a temperature sensor and a CT) Temperature control mode PID, ON/OFF (selectable with a switch on the rear panel) (advanced PID control with auto-tuning) Setting/designation accuracy (See notes 2 and 3.) ±0.5% of set (designated) value or ±2°C (whichever is larger) ±1 digit max. Hysteresis 0.0 to 999.9°C/°F (in units of 0.1 °C/°F) (during ON/OFF control action) Proportional band 0.0 to 999.9°C/°F (in units of 0.1 °C/°F) Integral (reset) time 0 to 9999 s (in units of 1 s) Derivative (rate) time 0 to 9999 s (in units of 1 s) Control period 1 to 99 s (in units of 1 s) Sampling period 500 ms Output refresh period 500 ms Display refresh period 500 ms Input shift range –99.9 to 999.9°C/°F (in units of 0.1 °C/°F) Alarm output setting range –999 to 9,999°C/°F (in units of 1 °C/°F) No. of banks 8 banks Internal current consumption 5 VDC, 0.33 A max. External supply voltage 24 VDC +10%/–15%, 0.2 A min. Dimensions (see note 4) 34.5 mm (W) x 130 mm (H) x 120.5 mm (D) Weight 360 g ±0.5% of set (designated) value or ±1°C (whichever is larger) ±1 digit max. –99.9 to 999.9°C/°F (in units of 0.1 °C/°F) Note 1. Set with the switch on the rear panel. See Appendix B Sensor Temperature Measurement Range for the measurable temperature range. 2. The set value and designated value coincide with each other. 3. The indication accuracy of thermocouples R and S at a temperature of 200°C max., that of thermocouples K and T at a temperature of –100°C max, and that of thermocouple U are all ±4°C, ±1 digit max. The indication accuracy of thermocouple B at a temperature of 400°C or below is not guaranteed. 4. See Appendix D Dimensions. 57 Appendix A Specifications Output Characteristics Transistor Output (Pulse) C200H-TV01 External supply voltage 24 VDC +10%/–15% Max. load voltage 24 VDC ( collector supplied voltage) max. Max. load current 100 mA max. Residual voltage when ON 3 V max. Leakage current when OFF 0.3 mA max. Voltage Output (Pulse) C200H-TV02 Output voltage 12 VDC Max. load current 40 mA (with short-protective circuit) Current Output (Linear) C200H-TV03 58 Output current 4 to 20 mA Permissible load impedance 600 Ω max. Current value accuracy 4±0.3 to 20±1 mA Appendix B Sensor Temperature Measurement Ranges 8 7 9 01 2 3 6 5 4 C200H-TV00 Thermocouple Set the thermocouple type with the switch on the rear panel. This switch is factory-set to 2 (K). The Data Setting Console can display the range from 10%FS below the lower limit to 10%FS above the upper limit. Input R Platinum vs. platinum rhodium 13% S Platinum vs. platinum rhodium 10% Range °C 0 to 1,700 °F Switch setting K (CA) Chromel vs. alumel J/L (IC) Iron vs. constantan T/U (CC) Copper vs. constantan E (CRC) Chromel vs. constantan B Platinum rhodium 30% vs. platinum rhodium 6% N Nichrosil vs. nisil 0 to 1,700 –200 to 1,300 –100 to 850 –200 to 400 0 to 600 100 to 1,800 0 to 1,300 0 to 3,000 0 to 3,000 –300 to 2,300 –100 to 1,500 –300 to 700 0 to 1,100 300 to 3,200 0 to 2,300 0 1 2 3/8 4/9 5 6 7 C200H-TV10 Platinum Resistance Thermometer OFF ON Set the platinum resistance thermometer type with the switch on the rear panel. This switch is factory-set to OFF (JPt100). The Data Setting Console can display the range from 10%FS below the lower limit to 10%FS above the upper limit. Input Range Switch setting JPt100 Pt100 °C –99.9 to 450.0 –99.9 to 450.0 °F –99.9 to 800.0 –99.9 to 800.0 OFF ON 59 Appendix C Heater Burnout Detection Heater Burnout Detection System The heater wiring is connected through the Current Transformer (CT). As a current flows through the heater wiring, an alternating current is induced in the CT which is dependent on the size of the current flowing. This induced current drops to zero if the heater burns out. The heater burnout alarm signal is output when the induced current is compared to the set current value. Heater Burnout Alarm Precautions • Turn on the heater power supply and the input terminal 24-VDC power supply at the same time as or before the C200H PC power supply. The heater burnout signal is output if the heater power supply or the input terminal 24-VDC power supply is turned on after the C200H PC power supply. • Temperature Control Unit operation continues if a burned-out heater causes a heater burnout alarm. Control signal output continues according to the control parameters. Take measures to detect the heater burnout alarm signal to allow early repair. • The heater burnout alarm is output when the control output is ON. Once the heater burnout alarm is output, it remains ON. Use one of the methods below to reset a heater burnout alarm. 1. Turn the Special I/O Unit Restart Flag (AR0100 to AR0109) ON and then back OFF. 2. Turn the C200H PC power supply OFF then back ON. 3. Set the heater burnout current limit to 0.0 then back to its original value. • Make sure that the current difference between normal operation and heater burnout is at least 2.5 A. Stable detection is difficult with a current difference less than 2.5 A. • Heater burnout detection is not possible with the current output type (C200HTV03) or with 3-phase heaters. • Set the heater burnout current to 0.0 when heater burnout detection is not required because the CT input wiring is not detected. Determining the Heater Burnout Detection Current • Determine the SV from the following equation: Normal current value + heater burnout current SV = 2 • If more than one heater is connected through the CT, take the heater burnout current as the value when the heater with the smallest current consumption is burned out. If all heaters consume equal current, take the heater burnout current as the value when any one heater is burned out. • Make sure that the current difference between normal operation and heater burnout is at least 2.5 A. Stable detection is difficult with a current difference less than 2.5 A. • Set the SV in the range between 0.1 A and 49.9 A. Heater burnout detection is not carried out if the SV is set to 0.0 A or 50.0 A. The alarm signal is always OFF if the SV is set to 0.0 or always ON if the SV is set to 50.0. • The total heater current during normal operation should not exceed 50 A. If the current exceeds 55.0 A, a CT Input Overflow error occurs and ffff is displayed if the heater current monitor is selected. 61 Appendix C Heater Burnout Detection Measure each current with the heater current monitor. In some cases the calculated current may differ from the actual measured value. Sample SV Calculations Example 1 Using one 200 VAC, 1 kW heater Normal current = 1000 = 5 A 200 Burnout current = 0 A SV = 5 + 0 = 2.5 A (≤ 49.9 A) 2 Example 2 Using three 200 VAC, 1 kW heaters Normal current = 1000 x 3 = 15 A 200 Burnout current with one heater burned out = 1000 x 2 = 10 A 200 15 + 10 SV = = 12.5 A (≤ 49.9 A) 2 Difference between normal and burnout current = 15 – 10 = 5 A (≥ 2.5 A) Specifications Heater Burnout Detection Characteristics Heater burnout detection setting range 0.1 to 49.9 A (in units of 0.1 A) (see note 1) Current difference required for heater burnout detection 2.5 A min. (normal time – burnout time) Heater current monitor range 0.0 to 55.0 A Monitor accuracy of input current +5% of FS +1 digit max. Min. detectable ON time 200 ms (see note 2) Note 1. If the heater burnout detection setting value is set to 0.0 or 50.0 A, no heater burnout detection is possible. The alarm signal is turned OFF if the heater burnout detection setting value is set to 0.0 A and turned ON if it is set to 50.0 A. 2. If the heating control output is turned ON for less than 200 ms, no heater burnout detection or heater current measurement is possible. E54-CT1/CT3 Current Transformer Max. continuous heater current 50 A Dielectric strength 1,000 VAC (1 min) Vibration resistance 50 Hz (approx. 10G) Weight E54-CT1: approx. 11.5 g; E54-CT3: approx. 50 g Accessories (E54-CT3 only) Contact: 2; Plug: 2 62 Appendix C Heater Burnout Detection Current Transformer Dimensions 21 E54-CT1 2.8 15 5.8 dia. 7.5 25 10.5 3 10 30 Two 3.5-dia. holes 40 2.36 dia. 30 E54-CT3 12 dia. 9 40 15 30 Two M3 holes with a depth of 4 mm 40 63 Appendix C Heater Burnout Detection Current Transformer Circuit Diagram Control output AC power supply CT Heater To Temperature Control Unit CT input terminal To Temperature Control Unit CT input terminal (no polarity) Heater cable Current Transformer 64 Appendix D Dimensions Heat/Cool Temperature Control Unit Unit Dimensions 130 20 34.5 100.5 11 120.5 131.5 Base unit Mounting Dimensions 17 Approx. 200 Weight: 360 g Data Setting Console Unit Dimensions 96 91 48 12 3 45 44 57 Weight: 120 g 65 Appendix D Dimensions Mounting Dimensions Panel Cutout Clearance +0.8 92 0 +0.6 45 0 Panel thickness 1 to 4 mm Clearance of at least 150 mm Allow a clearance of at least 150 mm behind the Data Setting Console when it is installed in the panel to allow cable connectors to be inserted. A clearance of 50 mm is sufficient if the rear panel can be opened. 66 Appendix E Parameters and Key Operations The Data Setting Console key operations and their relation to parameters are shown in the following table. Display Level 0 Display Level 1 LVL Power on Display Level 2 LVL h-o PV SP sl-l SP lower limit bk Bank number sl-h SP upper limit c-o al-1 Alarm 1 SV c-db Dead band at al-2 Alarm 2 SV c-sc Cooling coefficient bcpy Copy bank in-s Input shift value cp p c-cp Proportional band Heating control period Cooling control period i Integral time hys Hysteresis d Derivative time hysa LVL Heating output monitor Cooling output monitor Auto-tuning start/stop in-t Input-type monitor alt1 Alarm 1 mode alt2 Alarm 2 mode Alarm hysteresis ct Heater current monitor hb Heater burnout current 67 Index AB EH advanced PID control, 2 EEPROM error alarm, 55 alarm hysteresis setting, 30 error display, 26 alarm mode setting. See settings errors, data setting, 54 alarm SV 1 setting, 27 alarm SV 2 setting, 27 allocating memory, 36 auto-tuning start/stop setting, 31 See also settings bank number setting, 26 features, 2 function setting, 9 Heater Burnout Alarm, 55 heater burnout current setting. See settings heater burnout detection, precautions and current ranges, 61 heater current monitor, 30 hysteresis setting, 29 C command codes, settings, 41 I I/O refresh, 51 compensating conductors, specifications, 12 indicators, 7, 23 connections, 12 input shift value setting, 27 Connector Terminal Block Converter Unit, 16 input wiring Platinum Resistance Thermometer, 11, 13 precautions, 11 thermocouple, 10 control output variable monitor setting, 31 See also settings control period setting, 29 cooling coefficient setting, 29 input-type monitor. See settings integral time setting, 27 copy bank setting. See settings cover, removal and replacement, 8 CT input overflow error, 54 Current Transformer, 13 KM key operations, 67 memory contents, 38 D data flow, 21 data setting, 21 operating procedure, 20 Data Setting Console connecting cable and precautions, 17 features, 23 mounting, 66 parameter and setting tables, 24 physical features, 22 data settings, 43 dead band setting, 28 O operation setting, 9 operation timing, 50 output wiring, 13 circuit diagrams, 14 connection diagrams, 13 connectors and cable, 15 diagrams, 15 precautions, 15 P derivative time setting, 27 parameters, 67 detecting errors, 54 precautions, 4 Duplicate I/O Unit, 55 programming, examples, 43, 44, 47 69 Index proportional band setting, 27 switching memory contents, 8 PV setting, 26 switching memory contents and setting direction, 7 system configuration, 3 RS read operation timing, 51 Remote I/O Terminal, 16 selecting allocated memory, 36 sensor-type setting, 31 TU temperature alarm, 55 temperature measurements, ranges, 59 Special I/O Unit error, 55 troubleshooting CT input overflow, 54 data setting errors, 54 duplicate I/O unit, 55 EEPROM error, 55 Heater Burnout Alarm, 55 power supply, 56 RUN Indicator Unlit, 56 Special I/O Unit error, 55 temperature alarm, 55 specifications, general, table, 57 Unit, models, 3 SV setting, 26 Unit components, dimensions, 65 switch settings, 7 Unit nomenclature, 6 sensors, setting type, 8 setting and displaying parameters, method, 26 settings, source, 8 Slave Rack, number of mountable Units, 4 SP lower limit setting, 28 SP upper limit setting, 28 70 Revision History C200H-TV Heat/Cool Temperature Control Unit Operation Manual A manual revision code appears as a suffix to the catalog number on the front cover of the manual. Cat. No. W240-E3-1 Revision code The following table outlines the changes made to the manual during each revision. Revision code W240-E1-1 Date November 1993 Revised content Original production W240-E3-1 February 1998 Page 15: Table added to Secton 2–3 Page 42: Write/Read data range correcton in Heating and Cooling Control Period rows in the Table of Commands. 71 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: C200H-DSC01 ">
Download
Advertisement
Key features
Advanced PID Control
ON/OFF control
Two Heat/Cool Control Loops
Heater Burnout Detection
Eight Banks of Data Settings
Data Input and Display
User Programs Allow Reading and Writing of Data
Frequently asked questions
The Temperature Control Unit can be used with thermocouples (C200H-TV00) or platinum resistance thermometers (C200H-TV10).
Two heating and cooling control loops are possible with one Temperature Control Unit.
Three output specification versions are available: C200H-TV 1 for transistor output, C200H-TV 2 for voltage output, and C200H-TV 3 for current output.
The Current Transformer can be connected to each of the two control loops to facilitate rapid heater burnout detection and prompt correction of problems.
Data can be set and retrieved by means of C200H user programs or using the C200H-DSC01 Data Setting Console.
Eight data values such as set point (SP) and alarm set values can be preset in eight data banks for easy selection.
The Data Setting Console (sold separately) is used to input data and to display process values (PV) and set values (SV).