Omron SYSMAC C200H-TC Operation Manual
PDF
Document
Advertisement
Advertisement
Cat. No. W225-E1-3 SYSMAC C200H-TCjjj Temperature Control Units C200H-TCjjj Temperature Control Units Operation Manual Revised March 2000 iv Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. Failure to heed precautions can result in injury to people or damage to property. DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. ! WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. ! Caution Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury, or property damage. ! OMRON Product References All OMRON products are capitalized in this manual. The word “Unit” is also capitalized when it refers to an OMRON product, regardless of whether or not it appears in the proper name of the product. The abbreviation “Ch,” which appears in some displays and on some OMRON products, often means “word” and is abbreviated “Wd” in documentation in this sense. The abbreviation “PC” means Programmable Controller and is not used as an abbreviation for anything else. Visual Aids The following headings appear in the left column of the manual to help you locate different types of information. Note Indicates information of particular interest for efficient and convenient operation of the product. 1, 2, 3... 1. Indicates lists of one sort or another, such as procedures, checklists, etc. OMRON, 1993 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of OMRON. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because OMRON is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication. v vi TABLE OF CONTENTS PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 General Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operating Environment Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Application Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 1 System Configuration and Features . . . . . . . . . . . . . . . . . 1-1 1-2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Basic System Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 2 Connections and Settings . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 2-2 2-3 Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 3 Data Setting Console Operation . . . . . . . . . . . . . . . . . . . . 3-1 3-2 3-3 3-4 Operating Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Data Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nomenclature and Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Parameter Displays and Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 4 PC Memory Allocation and Programming . . . . . . . . . . . 4-1 4-2 4-3 Memory Allocation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Data Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 5 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Error Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Appendices A B C D Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sensor Temperature Measurement Ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heater Burnout Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii About this Manual: This manual describes the installation and operation of the C200H-TCjjj Temperature Control Units and includes the sections described below. Also briefly described is the basic operation and installation of the C200H-DSC01 Data Setting Console. Please read this manual carefully and be sure you understand the information provided before attempting to install and operate a Temperature Control Unit or Data Setting Console. Section 1 provides Temperature Control Unit features and describes its basic system configuration. Section 2 provides information on the connections and settings of the Temperature Control Units. Section 3 provides the basic operating procedures of the Data Setting Console including parameter settings and displays. Section 4 provides the C200H PC’s memory allocation for the Temperature Control Units. Basic programming procedures and examples are also provided. Section 5 provides possible errors and error remedies. The four Appendices provide references dealing with specifications, sensor temperature measurement ranges, heater burnout detection, and dimensions. ! WARNING Failure to read and understand the information provided in this manual may result in personal injury or death, damage to the product, or product failure. Please read each section in its entirety and be sure you understand the information provided in the section and related sections before attempting any of the procedures or operations given. ix PRECAUTIONS This section provides general precautions for using C200H Temperature Control Units and related devices. The information contained in this section is important for the safe and reliable application of the C200H Temperature Control Units. You must read this section and understand the information contained before attempting to set up or operate a C200H Temperature Control Unit. 1 Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 General Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operating Environment Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Application Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi 3 Safety Precautions 1 Intended Audience This manual is intended for the following personnel, who must also have knowledge of electrical systems (an electrical engineer or the equivalent). • Personnel in charge of installing FA systems. • Personnel in charge of designing FA systems. • Personnel in charge of managing FA systems and facilities. 2 General Precautions The user must operate the product according to the performance specifications described in the relevant manuals. Before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems, machines, and equipment that may have a serious influence on lives and property if used improperly, consult your OMRON representative. Make sure that the ratings and performance characteristics of the product are sufficient for the systems, machines, and equipment, and be sure to provide the systems, machines, and equipment with double safety mechanisms. This manual provides information for programming and operating the Unit. Be sure to read this manual before attempting to use the Unit and keep this manual close at hand for reference during operation. ! WARNING It is extremely important that a PC and all PC Units be used for the specified purpose and under the specified conditions, especially in applications that can directly or indirectly affect human life. You must consult with your OMRON representative before applying a PC system to the above-mentioned applications. 3 Safety Precautions ! WARNING Do not attempt to take any Unit apart while the power is being supplied. Doing so may result in electric shock. ! WARNING Do not touch any of the terminals or terminal blocks while the power is being supplied. Doing so may result in electric shock. ! WARNING Do not attempt to disassemble, repair, or modify any Units. Any attempt to do so may result in malfunction, fire, or electric shock. xii 5 Application Precautions 4 Operating Environment Precautions ! Caution Do not operate the control system in the following locations: • Locations subject to direct sunlight. • Locations subject to temperatures or humidity outside the range specified in the specifications. • Locations subject to condensation as the result of severe changes in temperature. • Locations subject to corrosive or flammable gases. • Locations subject to dust (especially iron dust) or salts. • Locations subject to exposure to water, oil, or chemicals. • Locations subject to shock or vibration. ! Caution Take appropriate and sufficient countermeasures when installing systems in the following locations: • Locations subject to static electricity or other forms of noise. • Locations subject to strong electromagnetic fields. • Locations subject to possible exposure to radioactivity. • Locations close to power supplies. ! Caution 5 The operating environment of the PC system can have a large effect on the longevity and reliability of the system. Improper operating environments can lead to malfunction, failure, and other unforeseeable problems with the PC system. Be sure that the operating environment is within the specified conditions at installation and remains within the specified conditions during the life of the system. Application Precautions Observe the following precautions when using the PC system. ! WARNING Always heed these precautions. Failure to abide by the following precautions could lead to serious or possibly fatal injury. • Always ground the system to 100 Ω or less when installing the Units. Not connecting to a ground of 100 Ω or less may result in electric shock. • Always turn OFF the power supply to the PC before attempting any of the following. Not turning OFF the power supply may result in malfunction or electric shock. • Mounting or dismounting I/O Units, CPU Units, Memory Units, or any other Units. • Assembling the Units. • Setting DIP switches or rotary switches. • Connecting cables or wiring the system. • Connecting or disconnecting the connectors. ! Caution Failure to abide by the following precautions could lead to faulty operation of the PC or the system, or could damage the PC or PC Units. Always heed these precautions. • Fail-safe measures must be taken by the customer to ensure safety in the event of incorrect, missing, or abnormal signals caused by broken signal lines, momentary power interruptions, or other causes. xiii 5 Application Precautions • Always use the power supply voltages specified in this manual. An incorrect voltage may result in malfunction or burning. • Take appropriate measures to ensure that the specified power with the rated voltage and frequency is supplied. Be particularly careful in places where the power supply is unstable. An incorrect power supply may result in malfunction. • Install external breakers and take other safety measures against short-circuiting in external wiring. Insufficient safety measures against short-circuiting may result in burning. • Do not apply voltages to the Input Units in excess of the rated input voltage. Excess voltages may result in burning. • Do not apply voltages or connect loads to the Output Units in excess of the maximum switching capacity. Excess voltage or loads may result in burning. • Disconnect the functional ground terminal when performing withstand voltage tests. Not disconnecting the functional ground terminal may result in burning. • Be sure that all the mounting screws, terminal screws, and cable connector screws are tightened to the torque specified in this manual. Incorrect tightening torque may result in malfunction. • Leave the label attached to the Unit when wiring. Removing the label may result in malfunction if foreign matter enters the Unit. • Remove the label after the completion of wiring to ensure proper heat dissipation. Leaving the label attached may result in malfunction. • Double-check all wiring and switch settings before turning ON the power supply. Incorrect wiring may result in burning. • Wire correctly. Incorrect wiring may result in burning. • Mount Units only after checking terminal blocks and connectors completely. • Be sure that the terminal blocks, Memory Units, expansion cables, and other items with locking devices are properly locked into place. Improper locking may result in malfunction. • Check the user program for proper execution before actually running it on the Unit. Not checking the program may result in an unexpected operation. • Confirm that no adverse effect will occur in the system before attempting any of the following. Not doing so may result in an unexpected operation. • Changing the operating mode of the PC. • Force-setting/force-resetting any bit in memory. • Changing the present value of any word or any set value in memory. • Resume operation only after transferring to the new CPU Unit the contents of the DM Area, HR Area, and other data required for resuming operation. Not doing so may result in an unexpected operation. • Do not pull on the cables or bend the cables beyond their natural limit. Doing either of these may break the cables. • Do not place objects on top of the cables or other wiring lines. Doing so may break the cables. • Use crimp terminals for wiring. Do not connect bare stranded wires directly to terminals. Connection of bare stranded wires may result in burning. • When replacing parts, be sure to confirm that the rating of a new part is correct. Not doing so may result in malfunction or burning. • Before touching a Unit, be sure to first touch a grounded metallic object in order to discharge any static built-up. Not doing so may result in malfunction or damage. xiv SECTION 1 System Configuration and Features This section describes Temperature Control Unit features and describes its basic system configuration. 1-1 1-2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Basic System Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features 1-1 Section 1-1 Features The Temperature Control Unit measures the temperature of an object with a connected temperature sensor (thermocouple or platinum resistance thermometer) and controls the temperature according to a preset control mode. PID with Feed-forward Circuitry (Feed-forward PID) Stable temperature control is achieved using PID control with feed-forward circuitry and an auto-tuning feature. ON/OFF control can also be selected. Two Temperature Control Loops with a Single Unit Two versions of Temperature Control Unit are available: the C200H-TC00j for thermocouple use and the C200H-TC10j for platinum resistance thermometers, each offering two control loops. Comprehensive Output Specifications Three types of output specification versions are available: C200H-TCjj1 for transistor output, C200H-TCjj2 for voltage output, and C200H-TCjj3 for current output. Heater Burnout Detection Through a Current Transformer, heater burnout can be quickly detected with a minimum current difference of 0.5 A and a heater burnout detection setting range of 0.1 to 4.9 A, and allows for the rapid correction of problems. Heater burnout detection is possible for each of the two control loops. Eight Banks of Data Settings Eight data values such as set point (SP) and alarm set values can be preset in eight data banks for easy selection. Data Input and Display The C200H-DSC01 Data Setting Console (sold separately) is used to input data and display process values (PV) and set values (SV). The easy-to-read display can be panel-mounted. User Programs Allow Reading and Writing of Data The 21 commands are used to read and set data with the C200H user programs. 2 Basic System Configuration 1-2 Section 1-2 Basic System Configuration C200H/C200HS, C200HX/HG/HE, CS1 PC Temperature Control Unit: C200H-TC00j (for thermocouples) C200H-TC10j (for platinum resistance thermometers) RUN Connecting cables: C200H-CN225 (2 m) C200H-CN425 (4 m) Data Setting Console C200H-DSC01 Recommended cable: ES1000-CA021-jjj (1/2 m) 24 VDC Loop 1 Loop 2 Temperature sensor Temperature sensor Relay box Electric furnace Electric furnace Heater Heater Remote I/O Terminal or Connector Terminal Block Converter Unit (Refer to page 18) Current Transformer (CT) Current Transformer (CT) Solenoid switch Temperature Control Unit Models Output type Sensor Transistor output Voltage output Current output Thermocouple C200H-TC001 C200H-TC002 C200H-TC003 Platinum resistance thermometer C200H-TC101 C200H-TC102 C200H-TC103 3 Basic System Configuration Section 1-2 Applicable CPU Units PC Series CPU Unit Mounting restrictions CS1 CS1H-CPUjj-E CS1G-CPUjj-E None C200HX/HG/HE C200HE-CPU11/32/42-E/ZE C200HG-CPU33/43-E/ZE C200HX-CPU34/44-E/ZE None C200HG-CPU53/63-E/ZE C200HX-CPU54/64-E/ZE C200HX-CPU65-ZE/85-ZE None C200HS C200HS-CPU01-E/01-EC/21-E/21-EC/31-E/03-E/ 23-E/33-E None C200H C200H-CPU01-E/03-E/11-E/21-E/23-E/31-E Cannot be mounted to the two rightmost slots on the CPU Rack. Number of Units The Temperature Control Unit belongs to the C200H Special I/O Unit group. A maximum of ten Special I/O Units (including PC Link Units) can be mounted on the CPU Rack, Expansion I/O Rack, and Slave Rack. Note Number of Units Mountable on Slave Rack 1. Refer to the manual for your CPU Unit for information on which Units belong to the Special I/O Unit group. 2. The Units used are limited by the maximum supply current and current consumption. Refer to the the manual for your CPU Unit for specific information. 3. The number of Units used with a Slave Rack is limited by data transmission considerations, as described below. The number of Special I/O Units used with a Slave Rack is limited by data transmission considerations, as shown in the table below. The numbers in the table indicate the maximum number of Units of groups A, B, C, or D which can be used with a single Slave Rack. A B C D High-speed Counter Units Position Control Units (NC111/112) ASCII Unit Analog I/O Units ID Sensor Units Fuzzy Logic Unit High-density and Mixed I/O Units Temperature Control Units Heat/Cool Temperature Control Units PID Control Units Cam Positioner Unit Temperature Sensor Units Voice Unit Position Control Unit (NC211) 4 units max. 8 units max. 6 units max. 2 units max. Note Precautions 4 1. When a combination of Units from groups A, B, C, and D is used, the number from each group must satisfy both the following equations: 3A + B + 2C + 6D ≤ 12 A+B+C+D≤8 2. Other Units can be added until the total number of units reaches ten. If PC Link Units are used, the number of Units including the PC Link Units must not exceed ten. The IR area of the C200H Special I/O Unit is allocated according to the setting of the unit number switch on the front panel, not the address of the slot where the unit is mounted. Refer to 4-1 Memory Allocation for the allocation of the memory area. Leave the two slots next to the CPU free. It is not possible to use devices connected to the CPU (such as the Programming Console) if these slots are occupied. Basic System Configuration Section 1-2 If the C200H Slave Rack is connected to another SYSMAC model Remote I/O Master Unit, such as the C500, C1000H, or C2000H, it is not possible to use a Special I/O Unit with the C200H Slave Rack. ! WARNING Always turn the PC power OFF before connecting or disconnecting a Unit, terminal block, or output connector. ! Caution New Functions Connect thermocouples with the appropriate compensating conductor. Wire I/O leads in separate ducts from power leads to prevent noise problems. Units with the following lot number or later support the following new functions. 01 Z 4 0 Year (1994): Last digit of the Christian year Month (December): (9: September, X: October, Y: November, X: December) Day (1st) Descriptions of New Functions RUN/STOP Bits Stop Bits have been added. These bits are supported with either fixed or normal memory allocations. Word (n+2), bit 06 Loop 1 Stop Bit Word (n+2), bit 04 Loop 2 Stop Bit Turn OFF to perform tem erature control for the temperature loop. Turn ON to stop control. Note These bits cannot be used when SW203-5 is set to ON to stop control in PROGRAM mode. When SW203-5 is ON, control is always stopped. Unit status will be as shown in the following table depending on the combination of SW203-5 settings and operating mode of the CPU Unit. SW203-5 setting OFF (control continues) ON (control stops) Operating mode of CPU Unit RUN or MONITOR PROGRAM RUN or MONITOR PROGRAM RUN STOP RUN STOP STOP STOP Stop Bits OFF (Run) RUN ON (Stop) STOP • To run or stop the temperature control using the Stop Bits, set SW203-5 to OFF. • To run or stop the temperature control only through the operating mode of the CPU Unit, keep the Stop Bit OFF (RUN). RUN/STOP Monitor Flags Stop Flags have been added. These flags are supported with either fixed or normal memory allocations. Word (n+8), bit 08 Loop 1 Stop Flag Word (n+9), bit 08 Loop 2 Stop Flag When OFF, temperature control is being performed loop When ON for the loop. ON, control is not being performed. These Flags turn ON and OFF depending on whether temperature control is run or stopped. Therefore, they do not necessarily have the same status as the Stop Bits described above. RAM Write Commands Previously, commands could be used to read and write to the EEPROM only. These new commands allow writing to RAM. 5 Basic System Configuration Section 1-2 When various settings require frequent rewriting, write to RAM, verify the setting values, and then save the data by writing it to EEPROM. The data written to the RAM will be deleted when the power is turned OFF. The following commands can be used to write to RAM. Parameter 6 Command Write Read Set point 4 0 Yes No Execution bank number 4 2 Yes No Alarm SV 1 4 3 Yes No Alarm SV 2 4 4 Yes No Input shift value 4 5 Yes No Proportional band 4 6 Yes No Integral (reset) time 4 7 Yes No Derivative (rate) time 4 8 Yes No SP lower limit 5 0 Yes No SP upper limit 5 1 Yes No Control period 5 7 Yes No Hysteresis 5 8 Yes No Alarm hysteresis 5 9 Yes No Heater burnout current 5 B Yes No Alarm 1 mode 6 4 Yes No Alarm 2 mode 6 5 Yes No SECTION 2 Connections and Settings This section provides information on the connections and settings of the Temperature Control Unit. 2-1 2-2 2-3 Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3-1 Input Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3-2 Output Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3-3 Data Setting Console Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Section 2-1 Nomenclature 2-1 Nomenclature C200H-TC00j (For Thermocouple) Front Panel Rear Panel Model label Cover RUN indicator SW2 (switching memory contents and setting direction under the cover) SW1 (Unit number setting) SW202 (sensor type setting) SW203 (operation and function settings) Data Setting Console connector Rack connector Output connector Sensor input terminal block Cold junction compensator C200H-TC10j (For Platinum Resistance Thermometer) Front Panel Rear Panel Model label Cover RUN indicator SW2 (switching memory contents and setting direction under the cover) SW1 (Unit number setting) SW202 (sensor type setting) SW203 (operation and function settings) Data Setting Console connector Rack connector Output connector Sensor input terminal block 8 Switch Settings Section 2-2 Indicators RUN 2-2 Lit when the Temperature Control Unit is operating normally. Unlit when an alarm occurs, and Unit operation stops. Switch Settings The function and setting of switches are identical for all models, except SW202. Unit Number SW1 Unit number setting 4 (3) 2 (1) 0 (5) (9) 8 (7) 6 The cut-out indicates the selected position. Turn the switch with a flat-blade screwdriver. Turn the switch until it clicks in position. Do not leave the switch between two settings. The addresses are allocated as shown in the following table according to the Unit number setting. Unit No. setting Allocated address 0 Wd 100 to 109 1 Wd 110 to 119 2 Wd 120 to 129 3 Wd 130 to 139 4 Wd 140 to 149 5 Wd 150 to 159 6 Wd 160 to 169 7 Wd 170 to 179 8 Wd 180 to 189 9 Wd 190 to 199 The switch is factory-set to 0. Note If the Unit number is set to an existing unit number, an alarm occurs and the PC does not operate. Turn the PC power OFF before setting the unit number. If the setting is changed with the power ON, the new setting will not be valid until the power is turned OFF and back ON again. Switching Memory Contents and Setting Direction SW2 Switching memory contents and setting direction 2 1 Remove the cover and set the switch with the tip of a ballpoint pen or similar object. O F F ON Pin OFF Pin 1 Pin 2 Function Switching memory contents Setting direction ON Normal CPU Unit OFF Fixed Data Setting Console 9 Switch Settings Section 2-2 The switch is factory-set to OFF: Parameters can be set from the Data Setting Console only. The new setting is valid immediately after the switch setting is changed. Removing and Attaching the Cover Removing the Cover Attaching the Cover Insert a small flat-blade screwdriver between the case and the cover at the top of the Unit and lever off the cover. Place the right edge of the cover against the case and press into position. Switching Memory Contents The contents of the allocated memory differ according to the Unit number setting. Normal Data can be set as required using commands (Refer to 4-1 Memory Allocation). Fixed data is allocated to memory. Direct reading and writing of data is possible. Fixed Refer to 4-1 Memory Allocation for details of the memory contents. Setting Direction Selects whether the data settings are made from the Data Setting Console or from the C200H PC, using a user program or Programming Console. Executed Bank Number The reading and setting of the executed bank number are possible from a user program or from a device, such as the Programming Console, regardless of the ON/OFF setting of switch SW2-2. Sensor Type SW202 Sensor type setting 8 7 9 01 2 3 6 5 4 C200H-TC00j Setting 0 1 2 3 4 5 6 7 8 9 Sensor type R S K J T E B N L U The switch is factory-set to 2. The selected position is shown by the arrow. Turn the switch with a small flatblade screwdriver. Selected position 10 Switch Settings Section 2-2 C200H-TC10j OFF ON Setting Sensor type OFF JPt ON Pt The switch is factory-set to OFF. See Appendix B Sensor Temperature Measurement Range for the measurable temperature range. Operation and Function Setting Operation and Function Setting 1 2 3 4 5 6 SW203 NO OFF Pin ON Function OFF ON 6 Not used --- --- 5 Operation in C200H program mode Continue control Interrupt control 4 Loop 2 Enabled Disabled (not used) 3 Display units °C °F 2 Control action Reverse (heating control) Normal (cooling control) 1 Control method Feed-forward PID ON/OFF control The switch is factory-set to OFF. Selects if the temperature control is continued or interrupted when the CPU Unit is set to PROGRAM mode. Operation in CPU Unit Program Mode Note Units with a lot number of 01Z40 or later are provided with Stop Bits for loops 1 and 2 in bits 06 and 04 of word (n+2). For further information, refer to page 5. Loop 2 Selects if input Loop 2 is used or not. Note 1. Always set this switch to the ON (disabled) position when input Loop 2 is not used. A sensor error occurs if this switch is set to the OFF (enabled) position when no temperature sensor is connected to Loop 2. 2. Use input Loop 1 when only one loop is used. It is not possible to use Loop 2 if Loop 1 is not used. Display Units Selects whether setting and SVs displayed on the Data Setting Console are in Celsius or Fahrenheit. 11 Wiring Section 2-3 Control Action Reverse: For heating control with a heater. The heater output is increased when the measured temperature is below the SP (i.e., a negative temperature difference). Normal: For cooling control of overheated objects using cooling water or some other method. The cooling water output is increased when the measured temperature is above the SP (i.e., a positive temperature difference). Control Method 2-3 Selects the method of control. Wiring 2-3-1 Input Wiring C200H-TC00j Thermocouple CT: Current Transformer TC: Thermocouple Heater wire A0 CT A1 Loop 1 A2 TC A3 A4 CT A5 Loop 2 A6 TC A7 A8 24 VDC 0.2 A A9 The 24-VDC output from the C200H CPU or the Power Supply Units is convenient. Terminal No. 12 Terminal name A0 CT A1 CT A2 TC (–) A3 TC (+) A4 CT A5 CT A6 TC (–) A7 TC (+) A8 24 VDC A9 0V Loop 1 Loop 2 Refer to the table below. Wiring Section 2-3 C200H-TC10j Platinum Resistance Thermometer CT: Current Transformer Pt: Platinum resistance thermometer Heater wire A0 CT A1 Loop 1 A2 Pt A3 A4 CT A5 Loop 2 Refer to the table below. A6 Pt A7 A8 24 VDC 0.2 A A9 The 24-VDC output from the C200H CPU or the Power Supply Units is convenient. Terminal No. Terminal name A0 CT A1 CT/Pt (B) A2 Pt (B) A3 Pt (A) A4 CT A5 CT/Pt (B) A6 Pt (B) A7 Pt (A) A8 24 VDC A9 0V Loop 1 Loop 2 Screw down Pt(B) and CT together at terminals A1 and A5. Input Wiring Precautions 1, 2, 3... Terminal Block Connections 1. Set the type of temperature sensor to thermocouple or platinum resistance thermometer with SW202 on the rear of the Unit. The Unit will not operate correctly if the switch setting does not match the type of temperature sensor connected. Do not connect different types of temperature sensors to Loop 1 and Loop 2. 2. If no input lead is connected to Loop 2, turn SW203-4 on the rear of the Unit ON to disable Loop 2. A sensor error occurs if this switch is set to the OFF (enabled) position when no temperature sensor is connected to Loop 2. 3. Be sure to connect (+) and (–), and (A) and (B) correctly. 4. Wire I/O leads in separate ducts from power leads to prevent noise problems. 5. A voltage of 24 VDC is used for the voltage output, current output and Data Setting Console power supply. (The power for the transistor output is supplied from the output connector.) 6. The terminal block is removable. Make sure that it is attached correctly after the input wiring connections are completed. Tighten the terminal block screws to a torque of 0.8 N S m. 13 Wiring Section 2-3 Crimp Terminals The screws on the terminal block are M3.5 self-rising terminal screws. Use the following types of M3.5 crimp terminals. 7 mm max. 7 mm max. Soldered Lead Strip insulation from 7 to 10 mm at the end of the wire and carefully solder the lead. ÉÉÉ ÉÉÉ 7 to 10 mm 10 Compensating Conductors Type of thermocouple Symbol Previous symbol (reference) Connect a thermocouple with the appropriate compensating conductor from the table below. Compensating conductor Symbol Previous symbol (reference) General-purpose,, standard d d class l Constituent materials + conductor B --- BX-G R S ----- RX-G, SX-G --RX-H, SX-H --- K CA KX-G KX-GS KX-H WCA-G WCA-GS WCA-H General-purpose,, standard d d class l KX-HS WCA-HS Heat-resistant, precision class WX-G WCA-G General-purpose, standard class WX-H WCA-H Heat-resistant, standard class VX-G WCA-G General-purpose, standard class Copper EX-G WCRC-G General-purpose, standard class EX-H WCRC-H Heat-resistant, standard class Alloy with nickel or chrome as j major constituent JX-G WIC-G General-purpose, standard class JX-H WIC-H Heat-resistant, standard class E J 14 CRC IC --- Classification by y application li i and d tolerance Copper Heat-resistant, standard class Heat-resistant, standard class – conductor Copper Alloy y with copper or nickel i k l as major j constituent Alloyy with nickel Alloy y with nickel as or chrome h as major j constituent i major constituent Iron Iron Alloy with copper or nickel as major j tit t constituent Wiring Section 2-3 Type of thermocouple Symbol Previous symbol (reference) T CC Compensating conductor Previous Symbol symbol (reference) Classification by application and tolerance TX-G WCC-G General-purpose, standard class TX-GS --- General-purpose, precision class TX-H WCC-H Heat-resistant, standard class TX-HS --- Heat-resistant, precision class Constituent materials + conductor – conductor Alloy with copper or nickel as major j tit t constituent Copper Wiring Platinum Resistance Thermometers Connect a platinum resistance thermometer with copper wire. All three leads should have the same thickness and the same length to give them identical resistances. Do not branch the two (B) leads near the terminal block as this increases measurement errors. Current Transformer Use an E54-CT1 or E54-CT3 Current Transformer (CT). Refer to Appendix C Heater Burnout Detection for details of the Current Transformer specifications and installation dimensions. 2-3-2 Output Wiring Connection Diagrams C200H-TCj01 Transistor Output B A NC NC 10 NC 9 NC NC NC COM 2 2 COM 24 VDC 1 1 24 VDC OUT1 OUT2 24 VDC NC: Not connected The pairs of terminals B2 to A2 and B1 to A1 are shorted internally. Always supply power to the 24-VDC terminal (B1) as this drives the internal circuits. C200H-TCj02/TCj03 Voltage/Current Output B OUT1 (+) OUT2 (+) A NC NC 10 10 9 9 NC NC OUT1 (–) OUT2 (–) 15 Wiring Section 2-3 Circuit Diagrams C200H-TCj01 Transistor Output Internal circuits 24 VDC OUT COM Internal circuits C200H-TCj02 Voltage Output OUT (+) OUT (–) Internal circuits C200H-TCj03 Current Output OUT (+) OUT (–) Applicable Connectors The following connector set manufactured by Fujitsu is included with the Unit: FCN-361J032-AU (soldering connector) FCN-360C032-B (cover) Connector Wiring Precautions After soldering the lead to each pin, insulate with heat-shrink tube to prevent shorting with the adjacent terminal. Connection Precautions Tighten the screws after inserting the connector into the Unit. Push the connector firmly into the Remote I/O Terminal or Connector Terminal Block Converter Unit until it fully locks. 16 Wiring Section 2-3 Output Cable The output cables in the table below are recommended. Model Cable length (L) ES1000-CA021-102 1m ES1000-CA021-202 2m 32-pin connector (manufactured by Fujitsu) FCN-361J032-AU 20-pin connector (manufactured by OMRON) XG4M-2030 L 30 63 16.1 28 46 Wiring Diagrams 32-pin connector B 20-pin connector A 16 16 10 10 9 9 2 1 B10 2 1 1 11 2 12 Note The pin numbers of the 20-pin connector are marked for convenience. Refer to them from the ∆ mark. 9 19 10 20 1 11 A10 2 B9 12 A9 9 B2 19 A2 10 B1 A1 20 17 Wiring Remote I/O Terminal Section 2-3 Remote I/O Terminal in the table below is recommended for transistor output. Model Specification G7TC-OC08 Common (+) Relays used 8 x G7T-1112S (max. resistive load: 220 VAC, 2A) Note One P7TF-OS08 I/O Terminal and two G7T-1112S Relays may be purchased separately and used. Wiring Diagram External View OUT1 OUT2 Wiring to the heater 24 VDC Connector Terminal Block Converter Unit The Connector Terminal Block Converter Units in the table below are recommended for voltage output and current output type. Model Terminal screw size XW2B-20G4 M 2.4 XW2B-20G5 M 3.5 External View 2-3-3 Data Setting Console Cables Connecting Cable Use the connecting cables in the table below (sold separately) to connect the Unit to the Data Setting Console. Model Cable length (L) C200H-CN225 2m C200H-CN425 4m L 39 17.3 17.5 16.1 10 18 Wiring Section 2-3 Connection Precautions 1, 2, 3... 1. Tighten the lock screws after inserting the connector into the Unit. 2. Push the connector firmly into the Data Setting Console until the clips fully lock. 3. Power is supplied through the connecting cable from the Temperature Control Unit. Nothing appears on the Data Setting Console display if no power is supplied to input terminals A8 and A9 of the Temperature Control Unit. 4. Install the supplied connector cover when the cable is not connected. 19 SECTION 3 Data Setting Console Operation This section provides the basic operating procedures of the Data Setting Console including parameter settings and displays. 3-1 3-2 3-3 3-4 Operating Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Data Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nomenclature and Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3-1 Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3-2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Parameter Displays and Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4-1 Table of Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4-2 How to Display and Set Parameter Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Section 3-1 Operating Procedure 3-1 Operating Procedure After preparing the CPU Unit, follow the procedure below to use the Temperature Control Unit. 1, 2, 3... 22 1. Set the switches on the front and rear panels according to the operating conditions. (Refer to 2-2 Switch Settings.) Set SW2-2 under the display cover to the OFF position to enable data setting from the Data Setting Console. 2. Mount to Rack. Turn OFF the PC power supply before mounting or dismounting the C200H on the Rack. 3. Connect the input wiring. (Refer to 2-3 Wiring.) The 24-VDC power supply must be connected. The Data Setting Console will not operate unless the 24-VDC power supply is connected. The sensors can be connected immediately before the system is tested. 4. Connect the Data Setting Console. (Refer to 2-3-3 Data Setting Console Cables.) 5. Turn ON the 24-VDC power supply and the PC power supply. Set the CPU Unit to PROGRAM mode. 6. Set data from the Data Setting Console. (Refer to the rest of this section.) Under either one of the following conditions (i.e., when control is stopped), the bank number can be changed to set data using the Data Setting Console. • When SW203-5 on the rear panel is set to ON (to stop temperature control in PROGRAM mode) and the CPU Unit is set to PROGRAM mode. • When the Stop Bit (word n+2, bit 06 for loop 1 and bit 04 for loop 2) is ON. In all other cases, the executed bank number (default value = 1) is displayed and the bank number cannot be changed from the Data Setting Console. Change the executed bank number with a user program or with a device, such as the Programming Console. 7. Test operation and adjust data. (Refer to the rest of this section.) Connect the output wiring and turn on the heater power to start the test operation. Monitor the control conditions and adjust the data until the required control is achieved. 8. Create the user programs. (Refer to Section 4 PC Memory Allocation and Programming.) Create the user programs for data setting, monitoring, and switching the bank number, as required. Set SW2-2 under the display cover to the ON position to enable data setting from the CPU Unit. 9. Start operation. Data Flow 3-2 Section 3-2 Data Flow The data flow in the Temperature Control Unit is shown in the diagram below. If SW2-2 is ON Write I/O bus Temperature Control Unit CS1, C200H-CPU Read Read Write If SW2-2 is OFF Data Setting Console The read operation and setting the executed bank number are possible from a user program or from a device, such as the Programming Console, regardless of the ON/OFF setting of SW2-2. Data written from the Data Setting Console and data written with the EEPROM write commands when SW2-1 (switching memory contents) is set to Normal are written to the Temperature Control Unit EEPROM and are consequently retained when the power supply is turned OFF. Data written with RAM write commands when SW2-1 (switching memory contents) is set to Normal, the SP value set when SW2-1 (switching memory contents) is set to Fixed and executed bank number settings made from the CPU Unit are written directly to RAM and are not saved to EEPROM. This data is lost when the power supply is turned OFF. Data Settings from Data Setting Console Set SW2-2 under the display cover to the OFF position to enable data setting from the Data Setting Console. While Temperature Control Unit is in control operation, all data can be set using the specified executed bank number (default value = 1). Change the executed bank number with a user program or with a device, such as the Programming Console. The executed bank number cannot be changed from the Data Setting Console. Under either one of the following conditions (i.e., when control is stopped), the bank number can be changed to set data using the Data Setting Console. • When SW203-5 on the rear panel is set to ON (to stop temperature control in the PROGRAM mode) and the CPU Unit is set to PROGRAM mode. • When the Stop Bit (word n+2, bit 06 for Loop 1 and bit 04 for Loop 2) is ON. 23 Nomenclature and Features 3-3 Section 3-3 Nomenclature and Features 3-3-1 Nomenclature Front View Side View Data display Operation indicators Display for Cam Positioner Cover Down Key Up Key (With cover open) Display Key Panel mounting bracket (Refer to Appendix D Dimensions for details about panel mounting.) Rear View Operation keys Select parameters Set data Switch Loops Level Key Loop Key Temperature Control Unit connector Connecting cable (sold separately) C200H-CN225 (2 m) C200H-CN425 (4 m) The bottom row of the operation keys have upper and lower labels. The upper labels apply to Temperature Control Unit operation. The lower labels are for the Cam Positioner Unit. Two display sheets are supplied: one for the Temperature Control Unit and one for the Cam Positioner Unit. If the Data Setting Console is to be used with the Temperature Control Unit only, stick the display sheet for the Temperature Control Unit. Note The Data Setting Console will not operate unless a 24-VDC power supply is connected to the Temperature Control Unit input terminals. 24 Nomenclature and Features Section 3-3 3-3-2 Features Data Display Name PV (Process Value) SV (Set Value) BK (Bank Number) Function Displays the PV or the parameter symbol selected with the Level or Display Key (Refer to next page). Displays the SV or setting/monitored data corresponding to the parameter symbol selected with the Level, Display or Loop Keys and indicated in the PV display. Displays the SP when the PV is indicated in the PV display. Displays the executed bank number. Displays the bank number of the displayed data when temperature control is interrupted. (See note) Note Temperature control is interrupted when SW203-5 on the rear panel is set to ON and also the CPU Unit is set to PROGRAM mode, or when the Stop Bit (word n+2, bit 06 for loop 1 and bit 04 for loop 2) is ON. Operation Indicators Name Function LOOP2 Indicates whether the displayed settings relate to Loop 1 or Loop 2. Press the Loop Key and hold down for approximately 2 seconds to switch between Loop 1 and Loop 2. Indicator OFF: Loop 1 Indicator ON: Loop 2 OUT (Output) Turns ON when the output is ON for transistor output or voltage output types. AT (Auto-tuning) Blinks at approximately 1 second intervals during auto-tuning. HB (Heater Burnout) Turns ON to indicate a heater burnout alarm. ALM1 (Alarm) Turns ON to indicate the temperature is in the alarm range set with Alarm SV 1 (upper- and lower-limit alarm). Refer to the following page. These indicators relate to the tl di l d currently displayed loop. Display Patterns Display Pattern 1 Display Pattern 2 Process value Executed bank number or displayed bank number Parameter symbol SV (Set value) Monitored value Execution status Set point Indicator OFF: Loop 1 Indicator ON: Loop 2 Executed bank number or displayed bank number Indicator OFF: Loop 1 Indicator ON: Loop 2 25 Parameter Displays and Settings Section 3-4 Operation Keys Name Level Key The parameter items are divided into three display groups (Refer to display levels 0 to 2 on the next page). Press this key to switch from one group to another. The display levels automatically cycle in the sequence 0 –> 1 –> 2 –> 0 when the key is held down for approximately 2 seconds. Display Key Press this key to select the required parameter from the selected display level 0 to 2 (Refer to table below). The parameters cycle automatically when the key is held down. Loop Key Press this key for approximately two seconds to switch between Loop 1 and Loop 2. Press this key to increment SV. The SV increment continuously while the key is held down. The SV display blinks when the value reaches its maximum limit. Up Key Down Key 3-4 Function Press this key to decrement an SV. The SV decreases continuously while the key is held down. The SV display blinks when the value reaches its minimum limit. Parameter Displays and Settings 3-4-1 Table of Parameters Display level 0 1 26 Parameter Display symbol Write Read Loop no. Bank no. Data range Default value Page Set point --- Yes Yes Yes Yes SP lower limit to SP upper limit 0°C 28 Bank number bk See note 5 Yes Yes No 1 to 8 1 32 Alarm mode TC 1, 4, 5: 0° to 9999°C Other TCs: –999° 999 to 9999°C 9999 C Pt 1, 4, 5: 0.0° to 999.9°C Other Pts: –99.9° to 999.9°C –99.9° to 999.9°C 0°C 29 0.0°C 31 33 Alarm SV 1 (see note 4) al1 Yes Yes Yes Yes Alarm SV 2 (see note 4) al2 Yes Yes Yes Yes Input shift value in5 Yes Yes Yes Yes Proportional band (see note 1) p Yes Yes Yes Yes 0.0° to 999.9°C 40.0°C Integral (reset) time (see note 1) i Yes Yes Yes Yes 0 to 9999 s 240 s Derivative (rate) time (see note 1) d Yes Yes Yes Yes 0 to 9999 s 40 s SP lower limit sll Yes Yes Yes No TC: –200°C Pt: –99.9°C 28 SP upper limit slh Yes Yes Yes No Sensor measuring range lower limit to (SP upper limit – 1 digit) (Sensor measuring range lower limit + 1 digit) to SP upper limit TC: 1,300°C Pt: 450.0°C 28 0°C Parameter Displays and Settings Display level 1 Parameter Section 3-4 Display symbol Control period (see note 1 and 3) Hysteresis (see note 2) Alarm hysteresis (see note 4) Write Read Loop no. Bank no. Data range Default value Page 31 cp Yes Yes Yes No 1 to 99 s 20 s hys Yes Yes Yes Yes 0.0° to 999.9°C 0.8°C hysa Yes Yes Yes No 0.0° to 999.9°C 0.2°C 30 31 Heater current monitor (see note 3) ct No Yes Yes No 0.0 to 5.5 A --- Heater burnout current (see note 3) hb Yes Yes Yes No 0.0 to 5.0 0.0 A 0.0: No heater burnout detection, alarm signal OFF 5.0: No heater burnout detection, alarm signal ON 2 o Control output variable monitor No Yes Yes No 0.0% to 100.0% --- 31 at Yes Yes Yes No --- --- 32 bcpy int Yes Yes Yes No --- --- 32 No Yes No No 0 to 9 Setting for SW202 Alarm 1 mode alt1 Yes Yes Yes No 2 Alarm 2 mode alt2 Yes Yes Yes No 0 to 9 Mode for Alarm SV 1/2 (0: no alarm) Auto-tuning start/ stop (see note 1) Copy bank Sensor-type monitor 29 2 Yes: Possible. No: Not possible or not required. Note 1. Only when PID control with feed-forward circuitry is selected 2. Only when ON/OFF control is selected. 3. Does not apply to current output. 4. Does not apply when Alarm Mode = 0 5. Under either one of the following conditions (i.e., when control is stopped), the bank number can be changed to set data using the Data Setting Console. • When SW203-5 on the rear panel is set to ON (to stop temperature control in the PROGRAM mode) and the CPU Unit is set to PROGRAM mode. • When the Stop Bit (word n+2, bit 06 for loop 1 and bit 04 for loop 2) is ON. In all other cases, the executed bank number (default value = 1) is displayed and the bank number cannot be changed from the Data Setting Console. Change the executed bank number with a user program or with a device, such as the Programming Console. 6. Thermocouple = TC Platinum Resistance Thermometer = Pt 27 Parameter Displays and Settings Section 3-4 3-4-2 How to Display and Set Parameter Data PV and SV (Display Level 0) PV Process value (monitored every 500 ms) SV Currently set set value. Units: °C or °F. The SV can be changed from this display. Valid SV Range Set the SV in the range between the SV lower limit and the SV upper limit. Error Display When a sensor error occurs, one of the codes below and the detected temperature blink alternately in the PV display. ser1 ser2 serr Temperature is out of the range: (sensor measurement range ± 10%FS). That is, 10%FS below the lower limit or 10%FS above the upper limit. Includes broken or incorrect sensor wiring. ser1 : Loop 1; ser2 : Loop 2 Abnormality in the cold junction compensating circuit. Applies to thermocouple type only. SP Lower Limit (Display Level 1) PV SP lower limit parameter symbol SV Currently set SV lower limit. Units: °C or °F. The SV lower limit can be changed from this display. When the sensor type is set with SW202 on the rear of the Unit, the SV lower limit is automatically set to the measuring range lower limit of the selected sensor, as shown below. However, the SP lower limit cannot be changed if the current SV lies inside the sensor measuring range. Default values TC: –200 °C Pt: –99.9 °C Change the set limit, if required. Set the lower limit in the following range: Sensor measuring range lower limit to (SP upper limit – 1 digit) The SV and “----” blink alternately on the display if the SP lower limit is set outside the limit defined above to indicate that the value is out-of-range. Reset the SP lower limit inside the permitted range. SP Upper Limit (Display Level 1) PV SP upper limit parameter symbol SV Currently set SV upper limit. Units: °C or °F. The SV upper limit can be changed from this display. When the sensor type is set with SW202 on the rear of the Unit, the SV upper limit is automatically set to the measuring range upper limit of the selected sensor, as shown below. However, the SP upper limit cannot be changed if the current SV lies inside the sensor measuring range. Default values TC: 1300 °C Pt: 450.0 °C Change the set limit, if required. Set the upper limit in the following range: (Sensor measuring range lower limit + 1 digit) to SP upper limit The SV and “----” blink alternately on the display if the SP upper limit is set outside the limit defined above to indicate that the value is out-of-range. Reset the SP upper limit inside the permitted range. 28 Parameter Displays and Settings Section 3-4 Alarms SV 1 and SV 2 (Display Level 0) PV Alarm 1/2 parameter symbol Currently set alarm value. Units: °C or °F. The setting can be changed from this display. The alarm mode is set with the Alarm 1/2 Mode parameter described on the following page. SV Two alarm SVs can be set for each loop and bank. Alarm 1 and Alarm 2 Modes (Display Level 2) PV Alarm 1/2 Mode parameter symbol SV Currently set alarm mode. The setting can be changed from this display. Two alarm modes can be set for each loop. Alarm Mode Alarm Type Alarm Range SP 0 0 No alarm 1 Upper- and lower-limit alarm 2 Upper-limit alarm 3 Lower-limit alarm x 4 Upper- and lower-limit range alarm x x 5 Upper- and lower-limit alarm with standby sequence x x 6 Upper-limit alarm with standby sequence 7 Lower-limit alarm with standby sequence 8 Absolute-value upper-limit alarm 9 Absolute-value lower-limit alarm x x x x x x x About the Standby Sequence Select the standby sequence to avoid an alarm output immediately after power is turned ON where the value is in the alarm range. The standby sequence recognizes that the value is out of the alarm range and then outputs an alarm when the value enters the alarm range once more. 29 Parameter Displays and Settings Section 3-4 Lower Limit Alarm with Standby Sequence Standby sequence cancel point Hysteresis OFF point Alarm SV 0°C Alarm output The standby sequence is restarted in the following situations. • When SV is changed. • When executed bank number is changed. • When alarm mode is changed. • When PC power supply is turned ON. • When restart flag is set ON. • When PROGRAM mode is switched to MONITOR or RUN while the control interrupt is set (SW203-5 is ON). • When the Stop Bit (word n+2, bit 06 or 04) goes OFF. Alarm Hysteresis (Display Level 1) PV Alarm hysteresis parameter symbol SV Current setting. Units: °C or °F. The setting can be changed from this display. A hysteresis band is provided to prevent chattering of the alarm output when the alarm output is turned from ON to OFF. Hysteresis bandwidth ON Hysteresis bandwidth ON OFF Input OFF Alarm SV Input Alarm SV The alarm output is OFF if the process value lies within the hysteresis band when the Unit is turned on. Heater Burnout Current (Display Level 1) PV Heater burnout current parameter symbol SV Currently set heater burnout current value. Units: Amperes (A). The setting can be changed from this display. Set the heater burnout current value in the range shown in the table below. Refer to Appendix C Heater Burnout Detection for more details about the alarm SVs. 30 0.0 No heater burnout detection. Alarm signal OFF. 0.1 to 4.9 Within heater burnout current SV range. 5.0 No heater burnout detection. Alarm signal ON. Parameter Displays and Settings Section 3-4 Heater Current Monitor (Display Level 1) PV Heater current monitor parameter symbol SV Currently set heater current value. Units: Amperes (A). If the current exceeds 5.5 A, a CT Input Overflow error occurs and ffff is displayed. Input Shift Value (Display Level 0) PV Input shift value parameter symbol SV Currently set input shift value. Units: °C or °F. The setting can be changed from this display. If the displayed temperature value differs from the actual temperature value due to the sensor position or some other conditions, set the input shift value such that the correct temperature is displayed. Control Period (Display Level 1) PV Control period parameter symbol SV Currently set control period. Units: Seconds (s). The setting can be changed from this display. The control period is the time required to complete one transistor output or voltage output ON/OFF cycle. ON OFF ON time Control period Control Output Variable Monitor (Display Level 2) PV Control output variable monitor parameter symbol SV Current control output variable. Units: percentage (%). The relationship between the control output variable and control period is defined by the formula below: ON time Control output variable (%) = x 100 Control period The control output variable during ON/OFF control (when SW203-1 on the rear panel is ON) is ON = 100% and OFF = 0%. Hysteresis (Display Level 1) PV Hysteresis parameter symbol SV Currently set hysteresis value. Units: °C or °F. The setting can be changed from this display. 31 Parameter Displays and Settings Section 3-4 Hysteresis is an operating band provided for ON/OFF operation to prevent output chattering (repeated ON/OFF switching) and eliminate noise influences. Hysteresis ON OFF SV Hysteresis is applied in the following situations. • When ON/OFF control is selected (SW203-1 is ON). • When PID control with feed-forward circuitry (SW203-1 is OFF) and P (proportional band) is 0. Bank Number (Display Level 0) PV Bank number parameter symbol SV Currently set bank number. During control operation: Executed bank number (default value = 1) Control operation interrupted: Currently displayed bank number Changing the Settings The bank number can be changed from the Data Setting Console in the following situations. • When the CPU Unit is set to PROGRAM mode and SW203-5 on the rear panel is set to ON to interrupt temperature control. • When the Stop Bit (word n+2, bit 06 for loop 1 or bit 04 for loop 2) is ON. When the above conditions are not met, the executed bank number cannot be changed from the Data Setting Console and the executed bank number (default value = 1) is displayed. Change the executed bank number with a user program or with a device, such as the Programming Console. Copy Bank (Display Level 2) Copies the data, except for the SV (set value) data, from bank number 1 to banks 2 to 8. PV SV Execute bank copy Bank being copied Bank copy completed Sensor-type Monitor (Display Level 2) PV Sensor-type monitor parameter symbol Sensor type currently set with SW202 on the rear panel. Number refers to the following if a platinum resistance thermometer is used: 0: JPt (OFF), 1: Pt (ON) SV Auto-tuning Start/Stop (Display Level 2) PV AT AT indicator blinks SV AT start 32 Process value (PV) Set point (SP) AT executing Parameter Displays and Settings Section 3-4 To interrupt, press the Level and Display Keys again to display at. When at appears, press the Up Key. On interrupt, the at display disappears and the process value is displayed. Auto-tuning operates only when SW203-1 on the rear panel is set to OFF to enable PID control with feed-forward circuitry. When auto-tuning is completed, the AT indicator stops blinking and the P, I, and D data is written to EEPROM. If necessary, the P, I, and D data can be changed as described in the following. Proportional Band (Display Level 0) PV Proportional Band parameter symbol SV Currently set Proportional Band. Units: °C or °F. The setting can be changed from this display. Integral (Reset) Time (Display Level 0) PV Integral time parameter symbol SV Currently set integral time. Units: second. The setting can be changed from this display. Derivative (Rate) Time (Display Level 0) PV Derivative time parameter symbol SV Currently set derivative time. Units: second. The setting can be changed from this display. 33 SECTION 4 PC Memory Allocation and Programming This section provides the C200H PC’s memory allocation for the Temperature Control Unit. Basic programming procedures and examples are also provided. 4-1 4-2 4-3 Memory Allocation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1-1 Memory Allocation Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1-2 Memory Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1-3 Table of Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Data Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3-1 C200HX/HG/HE, C200HS, C200H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3-2 CS1 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3-3 Operation Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3-4 I/O Refresh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Section 4-1 Memory Allocation 4-1 Memory Allocation Memory Allocation The Temperature Control Unit is allocated 10 words in the IR or CIO Area according to the unit number switch setting on the front of the Unit. These words are used as an I/O refresh data area. The IR or CIO Area words used by the Temperature Control Unit are refreshed each I/O refresh scan of the CPU Unit. CS1 Temperature Control Unit CIO area I/O refresh data area Unit#0 CIO 2000 to CIO 2009 Unit#1 CIO 2010 to CIO 2019 Unit#2 CIO 2020 to CIO 2029 Unit#3 CIO 2030 to CIO 2039 Unit#4 CIO 2040 to CIO 2049 Unit#5 CIO 2050 to CIO 2059 Unit#6 CIO 2060 to CIO 2069 Unit#7 CIO 2070 to CIO 2079 Unit#8 CIO 2080 to CIO 2089 Unit#9 CIO 2090 to CIO 2099 During PC I/O refresh, each scan is executed for the outputs (PC to Temperature Control Unit) followed by the inputs (Temperature Control Unit to PC). Wd (n) to Wd (n+2) Output refresh Wd (n+3) to Wd (n+9) Input refresh (n=2000 + 10 x Unit number) The terms “output” and “input” are defined from the CPU Unit. Temperature Control Unit C200HX/HG/HE, C200HS, or C200H IR area I/O refresh data area Unit#0 IR 100 to IR 109 Unit#1 IR 110 to IR 119 Unit#2 IR 120 to IR 129 Unit#3 IR 130 to IR 139 Unit#4 IR 140 to IR 149 Unit#5 IR 150 to IR 159 Unit#6 IR 160 to IR 169 Unit#7 IR 170 to IR 179 Unit#8 IR 180 to IR 189 Unit#9 IR 190 to IR 199 During PC I/O refresh, each scan is executed for the outputs (PC to Temperature Control Unit) followed by the inputs (Temperature Control Unit to PC). Wd (n) to Wd (n+2) Output refresh Wd (n+3) to Wd (n+9) Input refresh (n=100 + 10 x Unit number) The terms “output” and “input” are defined from the CPU Unit. Note A Duplicate I/O Unit error occurs if the set Unit number corresponds to the number of an existing Special I/O Unit. Selecting Allocated Data The data allocated to each IR word due to the Unit number setting is determined by the setting of SW2-1 on the front of the Unit. ON Normal All data can be set using commands. OFF Fixed Fixed data is allocated to memory. Direct reading and writing of data is possible. This setting becomes valid immediately after the switch is set. 36 Section 4-1 Memory Allocation 4-1-1 Memory Allocation Table SW2-1 Set for Fixed Memory Allocations (CS1: n=2000+10 x Unit number) (C200HX/HG/HE, C200HS, C200H: n=100 + 10 x Unit number) I/O Output Input Bit Word 15 14 13 12 Loop 1 SP (see note) Loop 2 SP (see note) Loop 1 executed bank number b Loop 2 executed bank number b 0 Loop 1 Loop 2 Stop 0 0 Stop n+3 n+4 n+5 n+6 n+7 Loop 1 PV (see note) Loop 2 PV (see note) Loop 1 SP (see note) Loop 2 SP (see note) Loop 1 executed bank number b Loop 2 executed bank number b 0 n+8 Loop 1 status data 0 Sen- CT 0 sor overerror flow 0 0 0 STOP 0 0 0 Loop 2 status data 0 Sen- CT 0 sor overerror flow 0 0 0 STOP 0 0 0 n n+1 n+2 n+9 11 10 09 08 07 06 05 04 03 02 0 01 00 0 SW data 2-2 2-1 Con- AT trol output HB AL1 AL2 Con- AT trol output HB AL1 AL2 Note For four-digit BCD and platinum resistance thermometer data, the least significant digit = 0.1, and the most significant digit (F) = minus (–). For example, “F200” represents –20.0°C for a platinum resistance thermometer. SW2-1 Set for Normal Memory Allocations (CS1: n=2000+10 x Unit number) (C200HX/HG/HE, C200HS, C200H: n=100 + 10 x Unit number) I/O Output Bit Word n n+1 n+2 15 14 13 12 Read/write instruction Read/write Loop no. Write data (see note) Loop 1 executed bank number 11 10 09 08 07 06 Bank no. Instruction Loop 2 executed bank number Loop 1 0 STOP 05 04 Loop 2 0 STOP 03 02 0 0 01 0 00 Write request 37 Section 4-1 Memory Allocation I/O Word Bit 15 Input 14 13 12 11 10 09 08 07 06 05 n+3 n+4 n+5 n+6 Loop 1 PV (see note) Loop 2 PV (see note) Read data 0 n+7 Loop 1 executed bank number b n+8 Loop 1 status data 0 Sen- CT 0 sor overerror flow 0 0 0 STOP 0 0 0 Loop 2 status data 0 Sen- CT 0 sor overerror flow 0 0 0 STOP 0 0 0 n+9 Write 0 error 04 0 Write 0 complete Loop 2 executed bank 0 number b 03 02 01 00 0 0 0 Read complete 0 0 SW data 2-2 2-1 Control output AT HB AL1 AL2 Control output AT HB AL1 AL2 Note For four-digit BCD and platinum resistance thermometer data, the least significant digit = 0.1, and the most significant digit (F) = minus (–). For example, “1000” represents 100.0°C for a platinum resistance thermometer. 4-1-2 Memory Contents SW2-1 Set for Fixed Memory Allocations (CS1: n=2000+10 x Unit number) (C200HX/HG/HE, C200HS, C200H: n=100 + 10 x Unit number) I/O Address Word Output Data contents Sets the Loop 1 and Loop 2 SP (set point) as 4-digit BCD data. For platinum resistance thermometer data, the least significant digit is 0.1. 0 1 Set the most significant digit to F for minus (–). (–) Note These specified values apply to the bank number set with Wd (n+2) and can only be changed in RAM. (Refer page 44) n 15 to 00 Loop 1 SP n+1 15 to 00 Loop 2 SP n+2 15 to 12 Loop 1 executed bank number Loop 2 executed bank number --- Sets the bank number executed for Loop 1 and Loop 2 as 1-digit BCD data. Set executed bank numbers from 1 to 8. If the value is set out of this range, the bank number reverts to the previous a ue (de au value a ue = 1). ) value (default 06 Loop 1 STOP 05 --- Bit set to 0 during temperature control of Loop 1 and set to 1 when the control stop is executed. This bit will not be available under the program mode with SW203-5 set to ON (same as the control stop). Not used. Set to 0. 04 Loop 2 STOP 03 to 00 --- 11 to 08 07 38 Data item Bit Not used. Set to 0. Bit set to 0 during temperature control of Loop 2 and set to 1 when the control stop is executed. This bit will not be available under the program mode with SW203-5 set to ON (same as the control stop). Not used. Set each bit to 0. Section 4-1 Memory Allocation I/O Input Address Word Bit Data item Data contents Outputs the Loop 1 and Loop 2 PV (process value) as 4-digit BCD data. data For platinum resistance thermometer data, data the least significant digit is 0.1. The most significant digit is F for minus (–). n+3 15 to 00 Loop 1 PV n+4 15 to 00 Loop 2 PV n+5 15 to 00 Loop 1 SP n+6 15 to 00 Loop 2 SP n+7 15 to 12 Outputs the bank number currently executed for Loop 1 and Loop 2 as 1-digit BCD data. Executed bank numbers are from 1 to 8. 07 to 02 Loop 1 executed bank number Loop 2 executed bank number --- 01 SW2-2 Outputs the ON/OFF status of SW2-2 (setting direction). 0: Data Setting Console 1: CPU Unit 00 SW2-1 Outputs the ON/OFF status of SW2-1 (switching memory contents). 0: Fixed 1: Normal Loop 1/2 Not used. Set to 0. status data 11 to 08 n+8 Loop 1 15 n+9 Loop 2 --- Outputs the Loop 1 and Loop 2 SP (set point) as 4-digit BCD data For platinum resistance thermometer data, data. data the least significant digit is 0.1. The most significant digit is F for minus (–). Not used. Each bit is set to 0. 14 Sensor error Bit set to 1 if the sensor is not connected, a sensor wire is broken, or the input data exceeds the operational temperature range. 13 CT overflow Bit set to 1 when the detected heater current exceeds 5.5 A. 12 to 09 08 --STOP Not used. Each bit is set to 0. Bit set to 0 during temperature control and set to 1 when the control stop is executed. 07 to 05 --- Not used. Each bit is set to 0. 04 Control output Bit set to 1 when the control output (transistor or voltage output) is ON. The bit is always 0 for current output. 03 02 AT HB 01 00 AL1 AL2 Bit set to 1 during auto-tuning (AT). Bit set to 1 if the detected heater current drops below the set heater burnout current value. (HB: heater burnout) Bit set to 1 when the temperature enters the set l f to page 25) alarm range (R (Refer 25). Note If the setting direction of the Temperature Control Unit is set to the CPU Unit and the CPU Unit is in PROGRAM mode, all word data will be 0. Therefore, if the CPU Unit is in PROGRAM mode and has been set for continuous control, the Temperature Control Unit will continue executing temperature control even when the CPU Unit stops operating and will assume that the SP has been changed to 0°C. To prevent this, set SW2-2 on the Temperature Control Unit to OFF (i.e., the setting direction is set to the Data Setting Console) before the CPU Unit stops operating and reset SW2-2 after the CPU Unit restarts. 39 Section 4-1 Memory Allocation SW2-1 Set for Normal Memory Allocations (CS1: n=2000+10 x Unit number) (C200HX/HG/HE, C200HS, C200H: n=100 + 10 x Unit number) I/O Address Word Output n Data item 15 and 14 Read/Write The data bit sets operation to read or write. Write = 01 Read = 00 13 and 12 Loop no. The data bit sets the Loop Number to which the read or write operation applies. Loop 1 = 01, Loop 2 = 10 11 to 08 Bank no. Sets the bank number to which the read or write operation applies as 1-digit BCD data. Set executed bank numbers from 1 to 8. 07 to 00 Command Sets the command code (Refer to page 41) for the read or write operation as 2-digit BCD data. n+1 15 to 00 Write data Set the SP for a write operation as 4-digit BCD data. For data including 0.1 units, the least significant digit represents 0.1. Set the most significant digit to F for minus (–). The write operation commences on the ON rising-edge of the write request flag (Wd (n+2), bit 00 ). n+2 15 to 12 Loop 1 executed bank number Loop 2 executed bank number Set the bank number currently executed for Loop 1 and Loop 2 as 1-digit BCD data. Executed bank numbers are from 1 to 8. If the value is set out of this range, the bank number reverts to the e ous value a ue (de au value a ue = 1). ) previous (default 07 --- Not used. Set to 0. 06 Loop 1 STOP Bit set to 0 during temperature control of Loop 1 and set to 1 when the control stop is executed. This bit will not be available under the program mode with SW203-5 set to ON (same as the control stop). 05 --- Not used. Set to 0. 04 Loop 2 STOP Bit set to 0 during temperature control of Loop 2 and set to 1 when the control stop is executed. This bit will not be available under the program mode with SW203-5 set to ON (same as the control stop). 03 to 01 --- Not used. Set each bit to 0. 00 Write request n+3 15 to 00 Loop 1 PV n+4 15 to 00 Loop 2 PV Turn this bit ON when writing the write data set with Wd (n+1) with the commands set to Wd (n). Turn this bit OFF after the write complete flag (Wd (n+6), bit 08) turns ON. Outputs the Loop 1 and Loop 2 PV (process value) as 4-digit BCD data. For platinum latinum resistance thermometer data, the least significant digit is 0.1. Set the most significant digit to F for minus (–). n+5 15 to 00 Read data Outputs the data read with the commands set with Wd (n). For data including 0.1 Units, the least significant digit represents 0.1. Set the most significant digit to F for minus (–). n+6 15 to 12 --- Not used. Each bit is set to 0. 11 Write error Bit set to 1 when the write data exceeds the set permissible range. The bit is automatically set to 0 on the OFF falling-edge of the write request flag (Wd (n+2), bit 00). 10 to 09 --- Not used. Each bit is set to 0. 08 Write complete Bit set to 1 when the write operation due to the instructions set with Wd (n) ends normally. The bit is automatically set to 0 on the OFF falling-edge of the write request flag (Wd (n+2), bit 00). 11 to 08 Input 40 Data contents Bit Read/Write command Section 4-1 Memory Allocation I/O Input Address Word Bit n+6 Data item Data contents 07 to 01 --- Not used. Each bit is set to 0. 00 Read complete 15 to 12 07 to 02 Loop 1 executed bank number Loop 2 executed bank number --- Bit set to 1 when the read operation due to the commands set with Wd (n) ends normally. The bit is set to 0 when the command is changed. Outputs the bank number currently executed for Loop 1 and Loop 2 as 1-digit BCD data. Executed bank numbers are from 1 to 8. 01 SW2-2 Outputs the ON/OFF status of SW2-2 (setting direction). 0: Data Setting Console 1: CPU Unit 00 SW2-1 n+8 Loop 1 15 9L n+9 Loop 2 14 --Sensor error Outputs the ON/OFF status of SW2-1 (switching memory contents). 0: Fixed 1: Normal Loop 1/2 Not used. Set to 0. status d data Bit set to 1 if the sensor is not connected, a sensor n+7 11 to 08 Not used. Each bit is set to 0. wire is broken, or the input data exceeds the operational temperature range. 13 CT overflow Bit set to 1 when the detected heater current exceeds 5.5 A. 12 to 09 --- Not used. Each bit is set to 0. 08 STOP Bit set to 0 during temperature control and set to 1 when the control stop is executed. 07 to 05 --- Not used. Each bit is set to 0. 04 Control output Bit set to 1 when the control output (transistor or voltage output) is ON. The bit is always 0 for current output. 03 02 AT HB 01 00 AL1 AL2 Bit set to 1 during auto-tuning (AT). Bit set to 1 if the detected heater current drops below the set heater burnout current value. (HB: heater burnout) Bit set to 1 when the temperature enters the set alarm l range (R (Refer f to page 25) 25). 4-1-3 Table of Commands The command codes shown below are set in bits (n Wd) 07 to 00 when the SW2-1 (switching memory contents) on the front panel is set for normal memory allocations. EEPROM Write/Read Command Parameter Command Write Read Loop no. Bank no. Actual data range Write/Read data range Default value Set point 0 0 Yes Yes Yes Yes SV lower limit to SV upper limit 0°C Executed bank number 0 2 Yes Yes Yes No 1 to 8 1 41 Section 4-1 Memory Allocation Parameter Alarm SV 1 (see note 4) Alarm SV 2 (see note 4) Command 0 0 3 4 Write Read Yes Yes Yes Yes Loop no. Yes Yes Bank no. Yes Yes Actual data range Alarm mode TC 1, 4, 5: 0° to 9999°C Other TCs: –999° to 9999°C 9999 C Pt 1, 4, 5: 0.0° to 999.9°C Other Pts: –99.9° to 999.9°C Write/Read data range Default value 0°C 0000 to 9999 F999 to 9999 0°C 0000 to 9999 F999 to 9999 Input shift value 0 5 Yes Yes Yes Yes –99.9° to 999.9°C F999 to 9999 0.0°C Proportional band (see note 1) 0 6 Yes Yes Yes Yes 0.0° to 999.9°C 0000 to 9999 40.0°C Integral (reset) time (see note 1) 0 7 Yes Yes Yes Yes 0 to 9999 s 240 s Derivative (rate) time (see note 1) 0 8 Yes Yes Yes Yes 0 to 9999 s 40 s SP lower limit 1 0 Yes Yes Yes No Sensor measuring range lower limit to (SP upper limit value – 1 digit) TC: –200°C Pt: –99.9°C SP upper limit 1 1 Yes Yes Yes No (SP lower limit + 1 digit) to sensor measuring range upper limit TC: 1,300°C Pt: 450.0°C Control period (see note 1 1 and 3) 7 Yes Yes Yes No 1 to 99 s 20 s Hysteresis (see note 2) 1 8 Yes Yes Yes Yes 0.0° to 999.9°C 0000 to 9999 0.8°C Alarm hysteresis (see note 4) 1 9 Yes Yes Yes No 0.0° to 999.9°C 0000 to 9999 0.2°C Heater current monitor (see note 3) 1 A No Yes Yes No 0.0 to 5.6 A 0000 to 0056 --- Heater burnout current ((see note 3)) 1 B Yes Yes Yes No 0.0 to 5.0 A 0000 to 0050 0.0 A 0.0: No heater burnout detection, alarm signal OFF 5.0: No heater burnout detection, alarm signal ON 0.0% to 0000 to 100.0% 1000 Control output variable monitor 2 0 No Yes Yes No --- Auto-tuning start/stop (see note 1) 2 1 Yes No Yes No AT start = 0001 AT stop = 0000 --- Copy bank 2 2 Yes No Yes No Run = 0001 --- Sensor-type monitor 2 3 No Yes Yes No 0 to 9 Setting for SW202 Alarm 1 mode 2 4 Yes Yes Yes No 2 Alarm 2 mode 2 5 Yes Yes Yes No 0 to 9 Mode for Alarm SV 1/2 (0: no alarm) 2 Yes: Possible. No: Not possible or not required. Note 42 1. Only when advanced PID control is selected. 2. Only when ON/OFF control is selected. 3. Does not apply to current output. A value of 5.6 (0056) for the heater current monitor indicates that the heater current value exceeds 5.6 A. Section 4-1 Memory Allocation 4. Does not apply when Alarm Mode = 0 5. Refer to 3-4 Parameter Displays and Settings for details of the parameters. 6. Thermocouple = TC Platinum Resistance Thermometer = Pt RAM Write Command Parameter Command Write Read Loop no. Bank no. Actual data range Write/Read data range Default value Set point 4 0 Yes No Yes Yes SV lower limit to SV upper limit 0°C Executed bank number 4 2 Yes No Yes No 4 3 Yes No Yes Yes 1 to 8 Alarm mode TC 1, 4, 5: 0° to 9999°C Other TCs: –999° to 9999°C 9999 C Pt 1, 4, 5: 0.0° to 999.9°C Other Pts: –99.9° to 999.9°C 1 Alarm SV 1 (see note 4) Alarm SV 2 (see note 4) 4 4 Yes No Yes Yes 0°C 0000 to 9999 F999 to 9999 0°C 0000 to 9999 F999 to 9999 Input shift value 4 5 Yes No Yes Yes –99.9° to 999.9°C F999 to 9999 0.0°C Proportional band (see note 1) 4 6 Yes No Yes Yes 0.0° to 999.9°C 0000 to 9999 40.0°C Integral (reset) time (see note 1) 4 7 Yes No Yes Yes 0 to 9999 s 240 s Derivative (rate) time (see note 1) 4 8 Yes No Yes Yes 0 to 9999 s 40 s SP lower limit 5 0 Yes No Yes No Sensor measuring range lower limit to (SP upper limit value – 1 digit) TC: –200°C Pt: –99.9°C SP upper limit 5 1 Yes No Yes No (SP lower limit + 1 digit) to sensor measuring range upper limit TC: 1,300°C Pt: 450.0°C Control period (see note 5 1 and 3) 7 Yes No Yes No 1 to 99 s 20 s Hysteresis (see note 2) 5 8 Yes No Yes Yes 0.0° to 999.9°C 0000 to 9999 0.8°C Alarm hysteresis (see note 4) 5 9 Yes No Yes No 0.0° to 999.9°C 0000 to 9999 0.2°C Heater burnout current ((see note 3)) 5 B Yes No Yes No 0.0 to 5.0 A 0000 to 0050 0.0 A Alarm 1 mode 6 4 Yes No Yes No Alarm 2 mode 6 5 Yes No Yes No 0.0: No heater burnout detection, alarm signal OFF 5.0: No heater burnout detection, alarm signal ON 0 to 9 Mode for Alarm SV 1/2 (0: no alarm) 2 2 Yes: Possible. No: Not possible or not required. Note 1. 2. 3. 4. Only when advanced PID control is selected. Only when ON/OFF control is selected. Does not apply to current output. Does not apply when Alarm Mode = 0 43 Programming Section 4-3 5. Data written by the RAM write command will disappear when the power is turned OFF. 6. Data cannot be read using the RAM write command. 7. Refer to 3-4 Parameter Displays and Settings for details of the parameters. 4-2 Data Flow Refer to 3-2 Data Flow for the data flow in the Temperature Control Unit. Before setting data with a user program or the Programming Console, turn ON SW2-2 of the Unit to enable data setting from the CPU Unit. However, the executed bank number can be set with a user program or from the Programming Console regardless of the ON/OFF setting of SW2-2. Data Settings SW2-1 (switching memory contents) may be set in either the OFF (Fixed) or ON (Normal) position, but care is required as the setting of this switch changes the stored data contents. 4-3 Programming 4-3-1 C200HX/HG/HE, C200HS, C200H Example with SW2-1 with Fixed Memory Allocations Description and Conditions Example: The user program makes the following settings: Loop 1 SP = 80°C Loop 2 SP = 200°C Loop 1 executed bank number = 1 Loop 2 executed bank number = 3 Conditions: C200H-TC001 (thermocouple) SW203 set to 2 (K). Unit number set to 0 (allocated memory: IR100 to IR109). SW2-1 set OFF (Fixed) and SW2-2 set ON (C200H PC). Sample Program 25315 10701 10700 (C200H) Fixed Set #0080 for word 100 (Loop 1 SP). MOV (21) 1 cycle ON #0080 100 Set #0200 for word 101 (Loop 2 SP). MOV (21) #0200 101 Set #1300 for word 102 (executed bank number). MOV (21) #1300 102 END (01) #1300 Loop 2 executed bank number Loop 1 executed bank number Be sure to set the correct values for the Loop 1 and Loop 2 SP. The SV value is #0000 (0°C) if no data is set. If the executed bank number is set to a value out of the range from 1 to 8 the bank number reverts to the previous value (default value = 1). Reading Monitored Data 44 Read monitored data into the program using Wd (n+3) to (n+9). Programming Section 4-3 Example 1: Write with SW2-1 Set for Normal Memory Allocations Description and Conditions Example The user program makes the following settings: Loop 1 SP = 200°C (Bank no. = 1) Loop 2 SP = 250°C (Bank no. = 2) Loop 1 executed bank number = 1 Loop 2 executed bank number = 2 Loop 1 heater burnout current value = 2.0 A Loop 2 heater burnout current value = 2.5 A Conditions C200H-TC001 (thermocouple) SW202 set to 2 (K). Unit number set to 0 (allocated memory: IR100 to IR109). SW2-1 set ON (Normal) and SW2-2 set ON (C200H PC). 45 Programming Section 4-3 Sample Program 10701 10700 DIFU (13) Normal (C200H) 25315 10701 23200 10700 23201 1 cycle ON (C200H) SW2-2 (10701) switch ON detection (C200H PC) Program runs when operation is started or SW2-2 turned ON Normal 23200 23201 MOV (21) #1200 #1200 Loop 2 executed bank number Loop 1 executed bank number 102 MOV (21) #5100 #5100 SP setting instruction Bank number Bit data : 0101 100 MOV (21) #0200 101 23202 Write data (200°C) Loop 1 Write DIFD (14) 23203 23201 To start next data S KEEP(11) 23202 10608 Write complete R 23203 #6200 MOV (21) SP setting instruction Bank number Bit data: 0110 #6200 100 MOV (21) Loop 2 Write #0250 101 23204 Write data (250°C) DIFD (14) 23205 23203 10608 S Write complete KEEP(11) 23204 To start next data R 23205 #501B MOV (21) #501B 100 MOV (21) #0020 Next page 46 101 Write data (2A) Heater burnout current value command Bank number not required Bit data: 0101 Loop 1 Write Programming Section 4-3 23206 DIFD (14) 23207 23205 10608 S Write complete KEEP(11) 23206 To start next data R 23207 #601B MOV (21) #601B 100 MOV (21) #0025 101 23208 10608 S Write complete KEEP(11) 10200 Heater burnout current value command Bank number not required Bit data: 0101 Loop 2 Write Write data (2.5A) Write request R 23201 DIFD (14) 23203 23208 23205 23207 END (01) 47 Programming Section 4-3 Timing Chart 1 cycle 25315 (1 cycle ON) 23201 23202 23203 23204 23205 23206 23207 10200 (Write request) 10608 (Write complete) ↑: Point of Write command execution In addition to the above, IR 23201 will turn ON for one cycle on the rising edge of SW2-2 (IR 10701). One cycle after IR 23208 turns ON, IR 10200 (write request) will turn ON. Example 2: Read with SW2-1 Set for Normal Memory Allocations Description and Conditions Example: The following data is read from the indicated addresses: Loop 1 PV: DM0000 Loop 1 control output variable: DM0001 Loop 2 heater current: DM0002 This read program is to be executed after writing the data with program example 1. Conditions: C200H-TC001 (thermocouple) SW202 set to 2 (K). Unit number set to 0 (allocated memory: IR100 to IR109. SW2-1 set ON (Normal) and SW2-2 set ON (C200H PC). 48 Programming Section 4-3 Sample Program Insert the program below before the END instruction in the program on page 47. 25313 MOV (21) Normally ON 103 Read Loop 1 PV from IR103 to DM 0000. Read operation is not affected by SW2-1 and SW2-2 settings. DM0000 23208 DIFD (14) 23300 23207 S KEEP(11) 23208 (A) 10608 Write complete 23300 10701 R 10700 23301 (C200H) Runs next Read command when final write complete is detected. Normal 23307 repeatedly executes the Read command when each Read Complete is detected. 23307 23301 MOV (21) #1020 #1020 100 DIFD (14) 23302 S 23302 KEEP(11) 23303 10600 Control output variable monitor command Bank number not required Bit data: 0001 Loop 1 Read Read complete Wait for Read Complete to read data R 23303 DIFD (14) 23304 Next page 49 Programming Section 4-3 23304 Read data from IR105 to DM 0001. MOV (21) 105 DM0001 MOV (21) #201A 100 DIFD (14) 23305 Execute next Read command. Heater Current #201A Monitor command Bank number not required Bit data 0010 Loop 2 Read S 23305 KEEP(11) 23306 10600 Read complete Wait for Read Complete to read data R 23306 DIFD (14) 23307 23307 MOV (21) 105 Read data from IR105 to DM 0002. DM0002 (B) Change the above program as shown below if only reading is to be carried out. Replace part (A) of the program with the following program. 10701 10700 DIFU (13) (C200H) Normal 25315 10701 23200 SW2-2 (10701) switch ON detection (C200H PC) 10700 23301 1 cycle (C200H) Normal ON Program runs when operation is started or SW2-2 turned ON 23200 Add an END instruction (01) at position (B) of the program. 50 Programming Section 4-3 Timing Chart 1 cycle 23301 23302 23303 23304 23305 23306 23307 Wd 105 (Read data) 10600 (Read complete) : Point of Read command execution 1 : Point where data (1) is read. 2 : Point where data (2) is read. 4-3-2 CS1 Series Example with Fixed Memory Allocations Description and Conditions Example: The user program makes the following settings: Loop 1 SP = 80°C Loop 2 SP = 200°C Loop 1 executed bank number = 1 Loop 2 executed bank number = 3 Conditions: C200H-TC001 (thermocouple) SW203 set to 2 (K). Unit number set to 0 (allocated memory: CIO 2000 to CIO 2009). SW2-1 set OFF (Fixed) and SW2-2 set ON (CPU Unit). 51 Programming Section 4-3 Sample Program A20011 200701 200700 1 cycle ON CPU Unit Fixed MOV (021) Set #0080 for word 2000 (Loop 1 SP). #0080 2000 MOV (021) Set #0200 for word 2001 (Loop 2 SP). #0200 2001 Set #1300 for word 2002 (executed bank number). MOV (021) #1300 2002 #1300 Loop 2 executed bank number END (001) Loop 1 executed bank number • Be sure to set the correct values for the Loop 1 and Loop 2 SP. The value is #0000 (0°C) if no data is set. • If the executed bank number is set to a value out of the range from 1 to 8, the bank number reverts to the previous value (default value = 1). Reading Monitored Data Read monitored data into the program using Wd (n+3) to (n+9). Example 1: Write Set for Normal Memory Allocations Description and Conditions Example The user program makes the following settings. This example writes to EEPROM. To write to RAM, add 4 to the leftmost digit of the command. Loop 1 SP = 200°C (Bank no. = 1) Loop 2 SP = 250°C (Bank no. = 2) Loop 1 executed bank number = 1 Loop 2 executed bank number = 2 Loop 1 heater burnout current value = 2.0 A Loop 2 heater burnout current value = 2.5 A Conditions C200H-TC001 (thermocouple) SW202 set to 2 (K). Unit number set to 0 (allocated memory: CIO 2000 to CIO 2009). SW2-1 set ON (Normal) and SW2-2 set ON (CPU Unit). Sample Program 52 Programming 20701 200700 CPU Unit Normal Section 4-3 SW2-2 (200701) switch ON detection (CPU Unit) DIFU (013) 2320 0 A20011 200701 200700 23201 1 cycle ON CPU Unit Normal Program runs when operation is started or SW2-2 turned ON 23200 23201 # 1200 MOV (021) #1200 Loop 2 executed bank number 2002 Loop 1 executed bank number # 5100 MOV (021) #5100 2000 MOV (021) SP setting instruction Bank number Bit data : 0101 Loop 1 Write #0200 2001 Write data (200°C) 23202 DIFU (014) 23203 To start next data 23201 KEEP(011) 23202 200608 Write complete Next page 53 Programming Section 4-3 23203 #6200 MOV (021) SP setting instruction Bank number Bit data: 0110 #6200 2000 Loop 2 Write MOV (021) #0250 2001 Write data (250°C) 23204 DIFD (014) 23205 23203 To start next data S KEEP(011) 23204 200608 Write complete R 23205 #501B MOV (021) #501B 2000 MOV (021) #0020 2001 Heater burnout current value command Bank number not required Bit data: 0101 Loop 1 Write Write data (2A) 23206 DIFD (014) 23207 23205 200608 S Write complete To start next data KEEP(011) 23206 R 23207 #601B MOV (021) #601B 2000 MOV (021) #0025 2001 23208 200608 S Write complete 23201 DIFD (014) 23203 23208 23205 23207 END (001) 54 Write data (2.5A) KEEP(011) 200200 R Heater burnout current value command Bank number not required Bit data: 0101 Loop 2 Write Write request Programming Section 4-3 Timing Chart 1 cycle A20011 (1 cycle ON) 23201 23202 23203 23204 23205 23206 23207 200200 (Write request) 200608 (Write complete) ↑: Point of Write command execution In addition to the above, CIO 23201 will turn ON for one cycle on the rising edge of SW2-2 (CIO 200701). One cycle after CIO 23208 turns ON, CIO 200200 (write request) will turn ON. Example 2: Read Set for Normal Memory Allocations Description and Conditions Example: The following data is read from the indicated addresses: Loop 1 PV: D0000 Loop 1 control output variable: D0001 Loop 2 heater current: D0002 This read program is to be executed after writing the data with program example 1. Conditions: C200H-TC001 (thermocouple) SW202 set to 2 (K). Unit number set to 0 (allocated memory: CIO 2000 to CIO 2009. SW2-1 set ON (Normal) and SW2-2 set ON (CPU Unit). 55 Programming Section 4-3 Sample Program Insert the program below before the END instruction in the program on page 54. CF113 MOV (021) Always ON 2003 Read Loop 1 PV from CIO 2003 to D0000. Read operation is not affected by SW2-1 and SW2-2 settings. D0000 23208 DIFD (014) 23300 23207 S KEEP(011) 23208 (A) 200608 Write complete 23300 200701 R 200700 23301 CPU Unit Runs next Read command when final write complete is detected. Normal 23307 repeatedly executes the Read command when each Read Complete is detected. 23307 23301 MOV (021) #1020 #1020 2000 DIFD (014) 23302 S 23302 KEEP(011) 23303 200600 Read complete R 23303 DIFD (014) 23304 Next page 56 Control output variable monitor command Bank number not required Bit data: 0001 Loop 1 Read Wait for Read Complete to read data. Programming Section 4-3 23304 Read data from CIO 2005 to D0001. MOV (021) 2005 D0001 MOV (021) #201A 2000 DIFD (014) 23305 Execute next Read command. Heater Current #201A Monitor command Bank number not required Bit data 0010 Loop 2 Read S 23305 KEEP(011) 23306 200600 Read complete Wait for Read Complete to read data. R 23306 DIFD (014) 23307 23307 MOV (021) 2005 Read data from CIO 2005 to D0002. D0002 (B) Change the above program as shown below if only reading is to be carried out. Replace part (A) of the program with the following program. 200701 200700 DIFU (013) CPU Unit Normal A20011 200701 23200 200700 23300 1 cycle ON SW2-2 (200701) switch ON detection (CPU Unit) CPU Unit Normal Program runs when operation is started or SW2-2 turned ON 23200 Add an END instruction (001) at position (B) of the program. 57 Programming Section 4-3 Timing Chart 1 cycle 23301 23302 23303 23304 23305 23306 23307 Wd 2005 (Read data) 200600 (Read complete) : Point of Read command execution 1 : Point where data (1) is read. 2 : Point where data (2) is read. 4-3-3 Operation Timing The following descriptions apply to the C200HX/HG/HE, C200HS, C200H, and CS1 Series. Write Operation Timing Command (Wd n) Write data (Wd n+1) Data (1) Data (2) Data (3) Data (4) ON Write request (Wd n+2), bit 00 Write complete (Wd n+6), bit 08 OFF ON OFF Approx. 140 ms 1, 2, 3... 58 1. The data is written to the Temperature Control Unit EEPROM when the Write Request Flag turns ON. 2. The Write Complete Flag turns ON when the data writing operation is completed. It takes approximately 140 ms to write the data. 3. The Write Complete Flag automatically turns OFF when the Write Request Flag turns OFF. Check the Write Complete Flag is ON before turning OFF the Write Request Flag. If the Write Request Flag is set to OFF before the Write Complete Flag turns ON the Write Complete Flag will not subsequently turn ON. Programming Section 4-3 Temporarily turn the Write Request Flag OFF before executing the second and subsequent write operations. Writing is enabled on the ON rising edge of the Write Request Flag. The Loop 1 and 2 executed bank number (Wd n+2) sets data directly. The data is written to the Temperature Control Unit RAM. If the value is set out of this range, the bank number reverts to the previous value (default value = 1). Timing for a Read Operation Command (n) Command (A) Read complete ON (Wd n+6), OFF bit 00 Approx. 140 ms Read data (Wd n+5) 1, 2, 3... Command (B) Read data (A) Read data (B) 1. The read data is output to Wd (n+5) approximately 140 ms after the Read command is executed. 2. The read data is updated every 100 ms. 3. When the Read command is modified, turn OFF the Read Complete Flag to execute the next read operation. 4-3-4 I/O Refresh The following descriptions apply to the C200HX/HG/HE, C200HS, C200H, and CS1 Series. Temperature control cannot be performed properly unless the I/O refresh interval is at least 8 ms. Therefore, create programs that satisfy all of the following conditions. • Set the cycle time to 8 ms min. If the program processing time is short for the C200HX/HG/HE, C200HS, and C200H, use the CYCLE TIME instruction SCAN(18) to set a minimum cycle time. If the program processing time is short for the CS1, set the cycle time to a minimum value in the PC Setup. • When using the I/O Refresh instruction IORF with the Unit, provide an interval of at least 8 ms between the end refreshes. • Provide an interval of at least 8 ms between the I/O Refresh instructions. Normal I/O refresh End refresh Normal I/O refresh End refresh 8 ms min. (Cycle time) 8 ms min. IORF I/O Refresh instruction IORF I/O Refresh instruction 8 ms min. 8 ms min. Normal I/O refresh End refresh 59 SECTION 5 Troubleshooting This section provides possible errors and error remedies. Error Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 Section 5 Error Detection Error Detection When an error occurs in an input or in the Unit, details of the error are reported to the Data Setting Console and input relays. Sensor Input Errors Display ser1 ser2 Error name Loop 1 sensor error Loop 2 sensor error Output status after error Cause Remedy Control output: The transistor output or voltage output turns OFF or the current output falls below 2 mA. Reading is ± 10%FS out of sensor measurement range (i.e., 10%FS below the lower limit or 10%FS above the upper limit). Check the sensor wiring. Alarm output: The alarm is out ut output assuming the input is ±10%FS. Replace the sensor. Replace the Unit. Correctly set switch SW203-4. Broken or incorrect sensor wiring Defective sensor Defective Unit SW203-4 is OFF (Loop 2 enabled) but no sensor connected to Loop 2 serr Cold junction compensating circuit error Control output: The transistor output or voltage output turns OFF or the current output falls below 2 mA. Abnormality in cold junction compensating circuit. Applies to thermocouple type only. Replace the Unit. Alarm output turns OFF. Data Setting Console When a sensor error occurs, one of the codes above and the detected temperature are displayed alternately. If a Loop 1 sensor error ser1 and a Loop 2 sensor error ser2 occur simultaneously, ser1 is displayed preferentially. Even if a sensor error is detected in one Loop, the other Loop continues to operate normally. Control operation restarts automatically five seconds after the cause of the error is corrected. The bits shown in the table below are set to 1 when a relay input error occurs. Wd (n+8), bit 14 Loop 1 sensor error Wd (n+9), bit 14 Loop 2 sensor error Both bits = 1 after a cold jjunction compensating i circuit i i error. CT Input Overflow Display ffff Error name CT input overflow Cause The detected heater current exceeds 5.5 A. Remedy Check the CT and heater wiring. The display shown in the table above will appear if the CT overflow error occurs when the heater current monitor is selected. The display returns to normal after the cause of the error is removed. The bits shown in the table below are set to 1 when the CT overflow error occurs. Wd (n+8), bit 13 Loop 1 CT overflow Wd (n+9), bit 13 Loop 2 CT overflow Heater Burnout Alarm Display HB indicator lit Error name Heater burnout Cause The detected heater current is below the heater burnout current value. Remedy Check the heater and heater wiring. Replace heater if necessary. Error displayed when an abnormality occurs in the loop currently being displayed. 62 Section 5 Error Detection The bits shown in the table below are set to 1 when a heater burnout alarm occurs. Wd (n+8), bit 02 Loop 1 heater burnout alarm Wd (n+9), bit 02 Loop 2 heater burnout alarm Use one of the methods below to reset a heater burnout alarm. • Turn ON the Special I/O Unit Restart Bit (AR 0100 to AR 0109 for the C200HX/ HG/HE, C200HS, C200H and A50200 to A50209 for the CS1) and then turn it OFF. • Turn the PC power supply OFF then back ON. • Set the heater burnout current limit to 00 then back to its original value. Temperature Alarm Display ALM1 indicator lit Error name Temperature alarm 1 Cause Remedy The temperature is in the alarm range set with Alarm SV 1. Check the temperature of the measured body. Check the set SP value. Error displayed when an abnormality occurs in the loop currently being displayed. No indicator is provided to show an ALM2 alarm. The bits shown in the table below are set to 1 when a temperature alarm occurs. Wd (n+8) Wd (n+9) Bit 01 Temperature alarm 1 Bit 00 Temperature alarm 2 Bit 01 Temperature alarm 1 Bit 00 Temperature alarm 2 Loop 1 Loop 2 EEPROM Error Display e111 Error name EEPROM error Output status after error Cause Control output: The transistor output or voltage output is OFF or the current output is less than 2 mA. Defective EEPROM Remedy Replace the Unit Alarm output is OFF. The RUN indicator turns off when an EEPROM error occurs. Duplicate I/O Unit The unit number duplicates the number of another Special I/O Unit. SR 25415 (for C200HX/HG/HE, C200HS, C200H) or A40113 (for CS1) will turn ON when an Duplicate I/O Unit error occurs. Refer to AR0000 to AR0009 for the C200HX/ HG/HE, C200HS, C200H or to A41100 to A41109 for the CS1 for the duplicated unit number. The CPU Unit will not operate during a duplicate I/O error. Set the Unit number to a separate number. Special I/O Unit Error I/O refresh not operating correctly between the CPU Unit and Temperature Control Unit. Operation is not interrupted when a Special I/O Unit error occurs. Refer to AR 0000 to AR 0009 for the C200HX/HG/HE, C200HS, C200H or to A41100 to A41109 for CS1 for the unit number where the error occurred. After correcting the cause of the error, turn ON the Special I/O Unit Restart Bit (AR 0100 to AR0109 for the C200HX/HG/HE, C200HS, C200H; A50200 to A50209 for the CS1) to restart operation. RUN Indicator Unlit The PC power supply is turned on but the RUN indicator is not lit. None of the errors described previously are detected. Replace the Unit. No Data Setting Console Display No 24 VDC power supply is connected to the Temperature Control Unit input terminals A8 and A9. 63 Error Detection Section 5 • The connecting cable is disconnected. • The connecting cable is broken. • A circuit in the Data Setting Console is defective. • A circuit in the Temperature Control Unit is defective. After determining the cause of the error, correct the problem or replace the Unit. Temperature Control Not Performed 64 Temperature control will not be performed in either one of the following cases. • SW203-5 on the rear panel is set to ON and the CPU Unit is in PROGRAM mode. • The Stop Bit (word n+2, bit 06 for loop 1 and bit 04 for loop 2) is ON. Change to proper settings. Appendix A Specifications General Specifications Conforms to the CPU Unit specifications. Item C200H-TC00j C200H-TC10j Connectable temperature sensor (see note 1) Current Transformer detection current No. of input points (loops) Thermocouple (R, S, K, J, T, E, B, N, L, U) Temperature control mode Setting/Indication accuracy (see note 2 and 3) Hysteresis PID, ON/OFF (selectable with a switch on the rear panel) (PID control with feed-forward circuitry with auto-tuning) ±0.5% of set (designated) value or ±2°C ±0.5% of set (designated) value or ±1°C whichever larger ±1 digit max. whichever larger ±1 digit max. 0.0° to 999.9°C/°F (in units of 0.1 °C/°F) (during ON/OFF control action) Proportional band 0.0° to 999.9°C/°F (in units of 0.1 °C/°F) Integral (reset) time 0 to 9999 s (in units of 1 s) Derivative (rate) time 0 to 9999 s (in units of 1 s) Control period 1 to 99 s (in units of 1 s) Sampling period 500 ms Output refresh period 500 ms Display refresh period 500 ms Input shift range –99.9° to 999.9°C/°F (in units of 0.1 °C/°F) Alarm output setting range –999° to 9,999°C/°F (in units of 1 °C/°F) No. of banks 8 banks Internal current consumption 5 VDC, 0.33 A max. External supply voltage 24 VDC +10%/–15%, 0.2 A min. Dimensions (see note 4) 34.5 mm (W) x 130 mm (H) x 120.5 mm (D) Weight 360 g Platinum resistance thermometer (JPt100, Pt100) 0.1 to 4.9 A (with a heater burnout detecting current difference of 0.5 A min.) Indication accuracy: ±5% FS ±1 digit max. Two points (two loops, each of which consists of a temperature sensor and a CT) –99.9° to 999.9°C/°F (in units of 0.1 °C/°F) Note 1. Set with the switch on the rear panel. See Appendix B Sensor Temperature Measurement Range for the measurable temperature range. 2. The set value and designated value coincide with each other. 3. The indication accuracy of thermocouples R and S at a temperature of 200°C max., that of thermocouples K and T at a temperature of –100°C max, and that of thermocouple U are all ±4°C, ±1 digit max. The indication accuracy of thermocouple B at a temperature of 400°C or below is not guaranteed. 4. See Appendix D Dimensions. 65 Appendix A Specifications Output Characteristics Open-collector Output (Pulse) C200H-TCj01 External supply voltage 24 VDC +10%/–15% Max. load voltage 24 VDC max. Max. load current 100 mA max. Residual voltage when ON 3 V max. Leakage current when OFF 0.3 mA max. Voltage Output (Pulse) C200H-TCj02 Output voltage 12 VDC Max. load current 40 mA (with short-protective circuit) Current Output (Linear) C200H-TCj03 66 Output current 4 to 20 mA Permissible load impedance 600 Ω max. Current value accuracy 4±0.3 to 20±1 mA Appendix B Sensor Temperature Measurement Ranges 8 7 9 01 2 3 6 5 4 C200H-TC00j Thermocouple Set the thermocouple type with the switch on the rear panel. This switch is factory-set to 2 (K). The Data Setting Console can display the range from 10%FS below the lower limit to 10%FS above the upper limit. Input Range R Platinum vs. platinum rhodium 13% S Platinum vs. platinum rhodium 10% °C 0 to 1,700 0 to 1,700 °F 0 to 3,000 0 to 3,000 0 1 Switch setting K (CA) Chromel vs. alumel J/L (IC) Iron vs. constantan T/U (CC) Copper vs. constantan E (CRC) Chromel vs. constantan B Platinum rhodium 30% vs. platinum rhodium 6% –200 to 1,300 –300 to 2,300 2 –100 to 850 –100 to 1,500 3/8 –200 to 400 –300 to 700 4/9 0 to 600 100 to 1,800 300 to 3,200 6 0 to 1,100 5 N Nichrosil vs. nisil 0 to 1,300 0 to 2,300 7 C200H-TC10j Platinum Resistance Thermometer OFF ON Set the platinum resistance thermometer type with the switch on the rear panel. This switch is factory-set to OFF (JPt100). The Data Setting Console can display the range from 10%FS below the lower limit to 10%FS above the upper limit. Input Range Switch setting JPt100 Pt100 °C –99.9 to 450.0 –99.9 to 450.0 °F –99.9 to 800.0 –99.9 to 800.0 OFF ON 67 Appendix C Heater Burnout Detection Heater Burnout Detection System The heater wiring is connected through the Current Transformer (CT). As a current flows through the heater wiring, an alternating current is induced in the CT which is dependent on the size of the current flowing. This induced current drops to zero if the heater burns out. The heater burnout alarm signal is output when the induced current is compared to the set current value. Heater Burnout Alarm Precautions • Turn ON the heater power supply and the input terminal 24-VDC power supply at the same time as or before the PC power supply. The heater burnout signal is output if the heater power supply or the input terminal 24-VDC power supply is turned ON after the PC power supply. • Temperature Control Unit operation continues if a burned-out heater causes a heater burnout alarm. Control signal output continues according to the control parameters. Take measures to detect the heater burnout alarm signal to allow early repair. • The heater burnout alarm is output when the control output is ON. Once the heater burnout alarm is output, it remains ON. Use one of the methods below to reset a heater burnout alarm. • Turn ON the Special I/O Unit Restart Bit (AR 0100 to AR 0109 for the C200HX/HG/HE, C200HS, C200H and A50200 to A50209 for the CS1) and then turn it OFF. • Turn the PC power supply OFF then back ON. • Set the heater burnout current limit to 0.0 then back to its original value. • Make sure that the current difference between normal operation and heater burnout is at least 0.5 A. Stable detection is difficult with a current difference less than 0.5 A. • Heater burnout detection is not possible with the current output type (C200HTCj03) or with 3-phase heaters. • Set the heater burnout current to 0.0 when heater burnout detection is not required because the CT input wiring is not detected. Determining the Heater Burnout Detection Current • Determine the SV from the following equation: Normal current value + heater burnout current SV = 2 • If more than one heater is connected through the CT, take the heater burnout current as the value when the heater with the smallest current consumption is burned out. If all heaters consume equal current, take the heater burnout current as the value when any one heater is burned out. • Make sure that the current difference between normal operation and heater burnout is at least 0.5 A. Stable detection is difficult with a current difference less than 0.5 A. • Set the SV in the range between 0.1 A and 4.9 A. Heater burnout detection is not carried out if the SV is set to 0.0 A or 5.0 A. The alarm signal is always OFF if the SV is set to 0.0 or always ON if the SV is set to 5.0. 69 Appendix C Heater Burnout Detection • The total heater current during normal operation should not exceed 5 A. If the current exceeds 5.5 A, a CT Input Overflow error occurs and ffff is displayed if the heater current monitor is selected. Measure each current with the heater current monitor. In some cases the calculated current may differ from the actual measured value. Sample SV Calculations Example 1 Using one 200 VAC, 800 W heater Normal current = 800 = 4 A 200 Burnout current = 0 A SV = 4 + 0 = 2 A (≤ 4.9 A) 2 Example 2 Using three 100 VAC, 100 W heaters Normal current = 100 x 3 = 3 A 100 Burnout current with one heater burned out = 100 x 2 = 2 A 100 3 + 2 SV = = 2.5 A (≤ 4.9 A) 2 Difference between normal and burnout current = 3 – 2 = 1 A (≤ 0.5 A) Specifications Heater Burnout Detection Characteristics Heater burnout detection setting range 0.1 to 4.9 A (in units of 0.1 A) (see note 1) Current difference required for heater burnout detection Heater current monitor range 0.5 A min. (normal time – burnout time) Monitor accuracy of input current ±5% of FS ±1 digit max. Min. detectable ON time 200 ms (see note 2) 0.0 to 5.5 A Note 1. If the heater burnout detection setting value is set to 0.0 or 5.0 A, no heater burnout detection is possible. The alarm signal is turned OFF if the heater burnout detection setting value is set to 0.0 A and turned ON if it is set to 5.0 A. 2. If the control output is turned ON for less than 200 ms, no heater burnout detection or heater current measurement is possible. E54-CT1/CT3 Current Transformer Max. continuous heater current 50 A Dielectric strength 1,000 VAC (1 min) Vibration resistance 50 Hz (approx. 10G) Weight E54-CT1: approx. 11.5 g; E54-CT3: approx. 50 g Accessories (E54-CT3 only) Contact: 2; Plug: 2 70 Appendix C Heater Burnout Detection Current Transformer Dimensions 21 E54-CT1 2.8 15 5.8 dia. 7.5 25 10.5 3 10 30 Two 3.5-dia. holes 40 2.36 dia. 30 E54-CT3 12 dia. 9 40 15 30 Two M3 holes with a depth of 4 mm 40 71 Appendix C Heater Burnout Detection Current Transformer Circuit Diagram Control output AC power supply CT Heater To Temperature Control Unit CT input terminal To Temperature Control Unit CT input terminal (no polarity) Heater cable Current Transformer 72 Appendix D Dimensions Temperature Control Unit Weight: 360 g Unit Dimensions 130 20 34.5 100.5 11 120.5 131.5 Base unit Mounting Dimensions 17 Approx. 200 Data Setting Console Weight: 120 g Unit Dimensions 96 91 48 12 3 45 44 57 73 Appendix D Dimensions Mounting Dimensions Panel Cutout Clearance +0.8 92 0 +0.6 45 0 Panel thickness 1 to 4 mm Clearance of at least 150 mm Allow a clearance of at least 150 mm behind the Data Setting Console when it is installed in the panel to allow cable connectors to be inserted. A clearance of 50 mm is sufficient if the rear panel can be opened. 74 Index A-B F-H alarm hysteresis, features, alarm mode setting, Heater Burnout Alarm, allocating memory, applications, precautions, auto-tuning start/stop setting, heater burnout current. See settings heater burnout detection, precautions and current ranges, hysteresis setting, bank number setting, C command codes, settings, EEPROM write/read command, RAM write command, compensating conductors, specifications, I I/O refresh, indicators, input shift value setting, control period setting, input wiring Platinum Resistance Thermometer, , precautions, thermocouple, copy bank setting, installation, precautions, cover, removal and replacement, integral time setting, Connector Terminal Block Converter Unit, control output variable monitor setting, CT input overflow error, Current Transformer, D M-O memory contents, operating environment, precautions, data flow, data setting, operating procedure, Data Setting Console connecting cable and precautions, features, mounting, parameter and setting tables, physical features, data settings, operating in PROGRAM mode, Operation and Function Setting, operation timing, output wiring, circuit diagrams, connectors and cable, diagrams, precautions, derivative time setting, detecting errors, Duplicate I/O Unit, P PID control with feed-forward circuitry, E EEPROM write/read command, command codes, settings, precautions, , applications, general, operating environment, safety, error display, programming, examples, , errors, data setting, proportional band setting, EEPROM error alarm, 75 Index R switch settings, switching memory contents, RAM write command, command codes, settings, switching memory contents and setting direction, read operation timing, system configuration, refresh, I/O, Remote I/O Terminal, S safety precautions. See precautions selecting allocated memory, sensor-type setting, sensors, setting type, Set Value display, upper and lower limits, setting and displaying parameters, method, settings heater burnout current, source, Slave Rack, number of mountable Units, T temperature alarm, temperature measurements, ranges, troubleshooting CT input overflow error, data setting errors, duplicate I/O unit, EEPROM error, power supply, RUN Indicator Unlit, Special I/O Unit error, temperature alarm, U Special I/O Unit error, Unit, models, specifications, general, table, Unit components, dimensions, standby sequence, Unit nomenclature, 76 Revision History A manual revision code appears as a suffix to the catalog number on the front cover of the manual. Cat. No. W225-E1-3 Revision code The following table outlines the changes made to the manual during each revision. Page numbers refer to the previous version. Revision code 1 Date August 1993 1A July 1995 2 September 1996 Revised content Original production Page 40: Note 1 corrected. Pages 35 to 39: Loop 1 STOP, Loop 2 STOP, and STOP data items added to the tables. Pages 39 and 40: EEPROM Write/Read Command title added to table and the RAM Write Command table added. Page 48: 4-3-5 I/O Refresh added. 3 March 2000 Added precautions to beginning of manual and changed “C200H PC” to either “PC” or “CPU Unit” throughout the manual. Page 3: Added a table of applicable CPU Units. Page 4 : Modified number of units mountable on Slave Rack in the table. Page 4 : Added information on new functions. Page 9 : Added information on Stop Bits and Stop Flags. Page 11: Changed screw tightening torque. Pages 20, 21, 25: Changed descriptions of data setting. Page 23: Added Stop Bit information to the Data Display note. Page 30: Added Stop Bit information to Changing the Settings. Page 34 : Added memory allocation information for the CS1. Page 45 : Modified sample program for write request. Page 49: Added programming examples for the CS1. Page 53, 59: Changed SR bit and restart bit. Page 53: Added information on cases where temperature control is not performed. 77 Authorized Distributor: Cat. No. W225-E1-3 Note: Specifications subject to change without notice. Printed in Japan ">
/
Download
Just a friendly reminder. You can view the document right here. But most importantly, our AI has already read it. It can explain complex things in simple terms, answer your questions in any language, and help you quickly navigate even the longest or most compilcated documents.
Advertisement