Sharp XE-A20S Owner Manual

Add to My manuals
54 Pages

advertisement

Sharp XE-A20S Owner Manual | Manualzz

ELECTRONIC CASH REGISTER

CAJA REGISTRADORA ELECTRONICA

MODEL

MODELO

XE-A20S

INSTRUCTION MANUAL MANUAL DE INSTRUCCIONES

WARNING

FCC Regulations state that any unauthorized changes or modifications to this equipment not expressly approved by the manufacturer could void the user’s authority to operate this equipment.

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment.

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

CAUTION

The AC power socket-outlet should be installed near the equipment and should be easily accessible.

FOR YOUR RECORDS

Please record below the model number and serial number for easy reference in case of loss or theft. These numbers are located on the right side of the unit. Space is provided for further pertinent data.

Model Number

Serial Number

Date of Purchase

Place of Purchase

INTRODUCTION

Thank you very much for your purchase of the SHARP Electronic Cash Register, Model XE-A20S.

Please read this manual carefully before operating your machine in order to gain full understanding of functions and features.

Please keep this manual for future reference. It will help you if you encounter any operational problems.

C A U T I O N !

Never install the batteries into the cash register before initializing it. Before you start operating the cash register, you must first initialize it, then install the batteries. Otherwise, distorted memory contents and

malfunction of the cash register will occur. For this procedure, please refer to page 7 .

IMPORTANT

• On the printer, a cutter to cut the paper roll is mounted. Always be careful not to cut yourself by the cutter.

• Install your register in a location that is not subject to direct radiation, unusual temperature changes, high humidity or exposed to water sources.

Installation in such locations could cause damage to the cabinet and the electronic components.

• Never operate the register with wet hands.

The water could seep into the interior of the register and cause component failure.

• When cleaning your register, use a dry, soft cloth. Never use solvents, such as benzine and/or thinner.

The use of such chemicals will lead to discoloration or deterioration of the cabinet.

• The register plugs into any standard wall outlet (120V AC ±10%).

Other electrical devices on the same electrical circuit could cause the register to malfunction.

• For protection against data loss, please install three “AA” batteries after initializing the cash register.

When handling the batteries, never fail to observe the followings:

Incorrectly using batteries can cause them to burst or leak, possibly damaging the interior of the cash register.

• Be sure that the the positive (+) and negative (-) poles of each battery are facing in the proper direction for installation.

• Never mix batteries of different types.

• Never mix old batteries and new ones.

• Never leave dead batteries in the battery compartment.

• Remove the batteries if you do not plan to use the cash register for long periods.

• Should a battery leak, clean out the battery compartment immediately, taking care to avoid letting the battery fluid come into direct contact with your skin.

• For battery disposal, follow the corresponding law in your country.

• If the register malfunctions, call 1-800-BE-SHARP for service - do not try to repair the register yourself.

• For a complete electrical disconnection, disconnect the main plug.

Customer Service Hotline

1-800-BE-SHARP

For Easy Set-up, see

“GETTING STARTED” (

page 7 ).

The Spanish version (summary of English version) is after the English version.

La versión española (el resumen de la versión inglesa) sigue a la versión inglesa.

1

2

CONTENTS

INTRODUCTION ............................................................................................................................................1

IMPORTANT ..................................................................................................................................................1

CONTENTS....................................................................................................................................................2

PARTS AND THEIR FUNCTIONS.................................................................................................................4

1 External View ........................................................................................................................................4

2 Printer ....................................................................................................................................................4

3 Mode Switch and Mode Keys ................................................................................................................5

4 Keyboard ...............................................................................................................................................5

5 Displays .................................................................................................................................................6

6 Drawer Lock Key ...................................................................................................................................6

GETTING STARTED......................................................................................................................................7

FOR THE OPERATOR

OVERVIEW OF FLOW OF DAILY SALES ENTRIES .................................................................................11

BASIC SALES ENTRY ................................................................................................................................12

1 Basic Sales Entry Example .................................................................................................................12

2 Error Warning ......................................................................................................................................13

3 Item Entries .........................................................................................................................................14

Single item entries ........................................................................................................................14

Repeat entries ..............................................................................................................................15

Multiplication entries .....................................................................................................................15

Split pricing entries .......................................................................................................................16

Single item cash sale (SICS) entry ...............................................................................................17

4 Displaying Subtotal..............................................................................................................................17

5 Finalization of Transaction ..................................................................................................................17

Cash or check tendering...............................................................................................................17

Cash or check sale that does not require tender entry .................................................................18

Charge (credit) sale ......................................................................................................................18

Mixed-tender sale .........................................................................................................................18

6 Tax Calculation....................................................................................................................................19

Automatic tax ................................................................................................................................19

Manual tax ....................................................................................................................................19

Tax delete .....................................................................................................................................19

Tax status shift .............................................................................................................................20

OPTIONAL FEATURES...............................................................................................................................21

1 Auxiliary Entries...................................................................................................................................21

Discount and premium entries using the percent key...................................................................21

Discount and premium entries using the discount key .................................................................21

Refund entries ..............................................................................................................................22

Non-add code number entries and printing ..................................................................................22

2 Auxiliary Payment Treatment ..............................................................................................................23

Currency conversion.....................................................................................................................23

Received-on Account and Paid-out Entries ..................................................................................24

No sale (exchange) ......................................................................................................................24

3 Automatic Sequence Key ( a key) Entries.........................................................................................24

CORRECTION .............................................................................................................................................25

1 Correction of the Last Entry (direct void) .............................................................................................25

2 Correction of the Next-to-last or Earlier Entry (indirect void) ...............................................................25

3 Subtotal Void .......................................................................................................................................26

4 Correction of Incorrect Entries not Handled by the Direct or Indirect Void Function ...........................26

FOR THE MANAGER

PRIOR TO PROGRAMMING ......................................................................................................................27

BASIC FUNCTION PROGRAMMING (For Quick Start) ............................................................................27

1 Date and Time Programming ..............................................................................................................27

2 Tax Programming for Automatic Tax Calculation Function .................................................................28

Tax programming using a tax rate ................................................................................................28

The tax table (applicable to the add-on tax) .................................................................................29

Quantity for doughnut tax exempt (for Canadian tax system) ......................................................31

AUXILIARY FUNCTION PROGRAMMING .................................................................................................32

1 Department Programming ...................................................................................................................32

2 PLU (Price Look-Up) and Subdepartment Programming ....................................................................33

3 Miscellaneous Key Programming ........................................................................................................35

Rate for % , & and V ..............................................................................................................35

Amount for ..............................................................................................................................36

Percent rate limitation for % and & ..........................................................................................36

Function parameters for % , & and ....................................................................................36

Function parameters for V .........................................................................................................37

Entry digit limit for r , R and t ............................................................................................38

Function parameters for C , c and A (when using as CA key) .........................................38

4 Text programming ...............................................................................................................................39

ADVANCED PROGRAMMING ....................................................................................................................44

1 Register Number and Consecutive Number Programming .................................................................44

2 Electronic Journal (EJ) Programming..................................................................................................45

3 Various Function Selection Programming 1 ........................................................................................47

Function selection for miscellaneous keys ...................................................................................47

Print format ...................................................................................................................................48

Receipt print format ......................................................................................................................48

Function selection for tax..............................................................................................................48

Other programming ......................................................................................................................49

4 Various Function Selection Programming 2 ........................................................................................51

Power save mode .........................................................................................................................51

Logo message print format ...........................................................................................................51

Online time out setting ..................................................................................................................52

Thermal printer density .................................................................................................................52

Language selection ......................................................................................................................53

Training clerk specification for training mode ...............................................................................53

AUTO key programming ...............................................................................................................54

5 Reading Stored Program.....................................................................................................................54

TRAINING MODE ........................................................................................................................................

56

READING (X) AND RESETTING (Z) OF SALES TOTALS ........................................................................57

EJ REPORT READING AND RESETTING .................................................................................................60

OVERRIDE ENTRIES ..................................................................................................................................61

CORRECTION AFTER FINALIZING A TRANSACTION (Void mode).......................................................61

OPERATOR MAINTENANCE......................................................................................................................62

1 In Case of Power Failure .....................................................................................................................62

2 In Case of Printer Error .......................................................................................................................62

3 Cautions in Handling the Printer and Recording Paper.......................................................................62

4 Replacing the Batteries .......................................................................................................................63

5 Replacing the Paper Roll.....................................................................................................................63

6 Removing a Paper Jam .......................................................................................................................66

7 Cleaning the Printer (Print Head / Sensor / Roller) .............................................................................66

8 Removing the Drawer..........................................................................................................................66

9 Opening the Drawer by Hand ..............................................................................................................66

10 Before calling for service .....................................................................................................................67

Error code table ............................................................................................................................67

SPECIFICATIONS .......................................................................................................................................68

MANUAL DE INSTRUCCIONES (VERSION EN ESPAÑOL)

3

4

PARTS AND THEIR FUNCTIONS

1

External View

Front view

Operator display

Rear view

Customer display

(Pop-up type)

Printer cover

Receipt paper

Keyboard

Power cord

Mode switch

USB port

Drawer

Drawer lock

Use only the USB cable (manufactured by SHARP) supplied with the XE-A20S for the connection with a PC. Never use other cables.

2

Printer

The printer is one station type thermal printer, therefore it does not require any type of ink ribbon or cartridge.

Lift the rear of the printer cover to remove. To re-install, hook the pawls on the cabinet and close.

Caution: The paper cutter is mounted on the printer cover. Be careful not to cut yourself.

Take-up spool

Paper roll cradle

Print roller arm

Print roller release rever

Inner cover

Paper positioning guides

Do not attempt to remove the paper roll with the print roller arm is locked. This may result in damage to the printer and print head.

3

Mode Switch and Mode Keys

The mode switch can be operated by inserting one of the two supplied mode keys - manager (MA) and operator

(OP) keys. These keys can be inserted or removed only in the “REG” or “OFF” position.

MA

OP

OP X/Z

REG

MGR

OFF X

1

/Z

1

VOID

PGM

X

2

/Z

2

Manager key (MA)

Operator key (OP)

The mode switch has these settings:

OFF: This mode locks all register operations. (AC power turns off.)

No change occurs to register data.

OP X/Z: To take individual clerk X or Z reports, and to take flash reports.

It can be used to toggle receipt state “ON” and “OFF” by pressing the R

key.

REG: For entering sales.

PGM: To program various items.

VOID: Enters into the void mode. This mode allows correction after finalizing a transaction.

MGR : For manager’s entries. The manager can use this mode for an override entry.

X1/Z1: To take the X/Z report for various daily totals

X2/Z2: To take the X/Z report for periodic (weekly or monthly) consolidation

4

Keyboard

Keyboard layout

CONV

RA %1

RCPT

/PO

%2

NUMBER

VOID RFND

DC SHIFT

ESC

BS SPACE

@/FOR

7

4

1

0

8

5

2

CL

9

6

3

00

PLU

/SUB

A

20

4

B

19

3

C

18

2

D

17

1

E

DEPT

#

F

24

8

G

23

7

H

22

6

I

21

5

J

DEPT

SHIFT

K

28

12

L

27

11

M

26

10

N

25

9

O

CLK#

P

32

16

Q

15

31

R

30

14

S

29

13

T

TAX

U

TAX1

SHIFT

V

AUTO

X

TAX2

SHIFT

Y

CHK CH

W Z

MDSE

SBTL

#/TM

SBTL

CA/AT/NS

The small characters on the bottom or lower right in each key indicates functions or characters which can be used for character entries for text programming. For details, refer to

page 39 .

Key names

Paper feed key

RA

RCPT

/PO

VOID

Received-on account key

Receipt print/Paid-out key

ESC

Void key

Escape key

CONV Conversion key

%1 %2 Percent 1 and 2 keys

RFND Refund key

Discount key

@/FOR

Multiplication key

Decimal point key

CL Clear key

00

PLU

/SUB

DEPT

#

DEPT

SHIFT

0 ~ 9 Numeric keys

PLU/Subdepartment key

Department code entry key

Department shift key

CLK# Clerk code entry key

1

17

~

16

32

Department keys

TAX

TAX1

SHIFT

TAX2

SHIFT

AUTO

Tax key

Tax 1 and 2 shift keys

Automatic sequence key

CHK Check key

CH Charge key

MDSE

SBTL

Merchandise subtotal key

#/TM

SBTL

Non-add code/Time display

/Subtotal key

CA/AT/NS

Total/Amount tender

/No sale key

5

6

5

Displays

Operator display Customer display (Pop-up type)

PLU/SUB

DEPT REPEAT

Clerk code

RCPT

OFF

DC SHIFT NUMBER

Amount: Appears in the far-right eight (max.) positions. When the amount is negative, the minus symbol “-” appears before the amount.

Number of repeats for repetitive registrations:

The number of repeats is displayed, starting at “2” and incremental with each repeat. When you have registered ten times, the display will show “0.”(2 → 3 ..... 9 → 0 → 1 → 2 ... )

Receipt function status:

The indicator “_” appears in the RCPT OFF position when the receipt function is in the OFF status.

Time: Appears in the far-right six positions (hour-minute -“ ” or hour-minute -“ ”) in the OP X/Z, REG, or MGR mode. “ ” is displayed in the morning (AM), and “ ” in the afternoon (PM). In the REG or MGR mode, press the s

key to display the time.

Machine state symbols

: Appears during programming.

: Appears when an error is detected.

: Appears when the subtotal is displayed or when the amount tendered is smaller than the sales amount.

: Appears when the V

key is pressed to calculate a subtotal in foreign currency.

: Appears when a transaction is finalized by pressing the A , C

or c

key.

: Appears when the change due amount is displayed.

: May appear in the far-left three positions at the timing of key entry when the electronic journal (EJ) memory is full. (Depending on programming.)

: Appears when the voltage of the installed batteries is under the required level. You must replace with new ones within two days. Refer to

page 63 for details.

: Appears when the batteries are not installed, or the installed batteries are dead. You must replace with

new ones immediately. Refer to page 63

for details.

: May appear right below the eighth and ninth places at the timing of finalization of a transaction when the electronic journal (EJ) memory is nearly full.

Also appears right below the tenth place when power save mode is effective.

: Appears when the print roller arm is not locked.

: Appears when the paper is not set or out.

6

Drawer Lock Key

This key locks and unlocks the drawer. To lock it, turn 90 degrees counterclockwise. To unlock it, turn 90 degrees clockwise.

GETTING STARTED

Please follow the procedure shown below. The batteries are not installed and the power is OFF.

1

Installing the cash register

AC outlet.

Find a stable surface where the cash register is not subject to water sources or direct sunlight near an

Unpack the cash register and make sure all accessories are included. For details of accessories, please refer to

“Specifications” section.

2

Initializing the cash register

In order for your cash register to operate properly, you must initialize it before programming for the first time. Follow this procedure.

1.

Insert the manager (MA) key into the mode switch and turn it to the REG position.

2.

Insert the plug into the AC outlet. The buzzer will sound three times.

IMPORTANT: This operation must be performed without batteries installed.

3.

The cash register has now been initialized. The register display will show “0.00” with “ ”.

OPX/Z

OFF

REG

MGR

VOID

PGM

X1/Z1

X2/Z2

If the buzzer does not sound when the plug is inserted, the initialization has not been done successfully. (This will occur when the voltage is still high because you operated the cash register just before starting initialization.) In this case, wait at least one minute after pulling out the plug, and insert the plug again.

3

Installing batteries

Three new “AA” batteries must be installed in the cash register to prevent the data and user-programmed settings from being erased from the memory, when the AC cord is accidentally disconnected or in case of power failure. Once installed, the batteries will last approximately one year before needing replacement. At this time, the “ ” symbol will appear on the display to indicate the batteries are low and must be replaced within two days. If the no battery symbol “ ” appears, you must install the batteries at once.

Install three new “AA” batteries according to the procedure shown below with the AC cord connected and the mode switch set to the REG position:

1.

Push the printer cover forward and detach it.

Be careful with the paper cutter, so as not to cut yourself.

2.

Open the battery compartment cover next to the paper roll cradle.

7

8

3. Insert three new “AA” batteries as illustrated at the right.

When the batteries are properly installed “ ” on the display will disappear.

4. Close the battery compartment cover.

Be sure to observe precautions shown on

page 1 when handling

batteries.

4

Installing a paper roll

Precaution: The paper cutter is mounted on the printer cover. Take caution when removing and installing the cover.

The register can print receipts or journals. For the printer, you must install the paper roll provided with the register, even when you program the register for not printing receipts or journals.

Install the paper roll according to the procedure shown below with the AC cord connected and the mode switch set to the REG position:

1.

Lift up the print roller release lever to unlock and open the print roller arm.

Print roller arm

Print roller release lever

2.

Set a paper roll in the paper roll cradle as illustrated at the right.

3.

Feed the end of the paper along with the paper positioning guides as illustrated at the right.

To the printer

Correct

Paper positioning guides

To the printer

Incorrect

4. While holding down the paper, slowly close the print roller arm, and push down the arm until you hear a click locking the arm. Make sure securely you push down the center of the wing part of the arm as illustrated at the right. The paper will be fed automatically.

If the print roller arm is not securely locked, printing is not done right. If this problem occurs, open the arm, and close the arm as instructed above.

5. When not using the take-up spool (using as receipt paper):

• Cut off the excess paper using the edge of the inner cover, and replace the printer cover. Press the

F key to make sure the paper end comes out of the printer cover and clean paper appears.

If the paper end does not come out, open the printer cover, and pass the paper end between the paper cutter and the paper guide of the printer cover, and replace the cover.

When using the take-up spool (using as journal paper):

• Insert the end of the paper into the slit in the spool. (Press the

F key to feed more paper if required.)

• Wind the paper two or three turns around the spool shaft.

• Set the spool on the bearing, and press the

F

key to take up excess slack in the paper.

• Replace the printer cover.

When using a paper roll as journal paper, you must change the printing style. Refer to “Print Format” in “Various

Function Selection Programming 1” section (Job code 6) for changing the printing style.

5

Programming date, time and tax

The cash register provides text languages of English, French and Spanish. It is preset to English.

If you want to change the language, you must change it before programming. Refer to “Language selection” in “Various Function Selection Programming 2” section for changing the language.

Before you can proceed with registration of sales, you must program :

• date

• time

• tax

Please refer to the BASIC FUNCTION PROGRAMMING section for details ( page 27 ).

9

10

6

Programming other necessary items

While the cash register is pre-programmed so it can be used with minimal setup, it does provide you with optional functions. Before you start programming, please read through the sales operations section to understand optional functions. The main optional functions are listed below.

• PLU (price lookup)

• Consecutive number

• Machine number

• Receipt or journal printing selection (factory setting: receipt printing)

• Power save mode (factory setting: goes into power save mode in 30 minutes)

• Electronic journal (EJ) memory size (factory setting: 2000 lines are storable. Up to 3000 lines)

The memory for electronic journal is commonly used for PLU. If you change the setting, the maximum number of PLU code will decrease from 1200 to 200.

• Text programming for clerk name, department items, PLU/subdepartment items, logo messages printed on the top or bottom of receipts, function texts and foreign currency symbol

• Split pricing entry

This is not factory preset. You must enable this function.

• Foreign currency conversion rate

You must set a conversion rate to use V key.

• Preset unit price for departments and PLUs

• Preset amount for -

• Preset rates for % &

You do not have to program these preset prices/amount/rates because you can enter when registration. It might be convenient to preset so you do not have to re-enter every time.

• Amount entry digit limit for PO amount, RA amount, Manual tax amount

The factory setting makes the maximum amount you can enter. You can program to limit the amount.

• Key sequence for AUTO key

• Online time out setting

• Specification of clerk to be trained

Department programming:

The cash register is pre-programmed for departments as follows:

Department: Allow open price entry, taxable status- taxable 1 for department 1 to 10, and non taxable for department 11 to 99

When you use department 11 or above, and/or you apply taxable status other than taxable 1 for department 1 to

10, you must change department settings. Please refer to the department programming section for programming details.

7

Starting sales entries

Now you are ready for sales registration.

FOR THE OPERATOR

OVERVIEW OF FLOW OF DAILY SALES ENTRIES

Things to do before you start sales entries:

• Make sure the power cord is securely inserted into the AC outlet.

• Turn the mode switch to OP X/Z position, and check if time is correctly set.

• Replace the drawer, if removed for safety.

• Check if there is enough paper on roll.

• Select receipt ON/OFF function.

• Make any necessary programming for the day in PGM mode.

For details, refer to BASIC SALES ENTRY, page 12 . For drawer and paper roll, refer to OPERATOR

MAINTENANCE, page 62

and for programming, refer to programming sections.

Things you can do for sales entries:

• Item entries

• Item repeat entries

• Item multiplication entries

• Single item cash sale (SICS), if programmed.

• Split pricing entries, if programmed.

• Displaying subtotals

• Cash/Check/Charge sale

• Cash tendering in a foreign currency, if the currency conversion rate is programmed.

• Manual tax entry

• Discount or premium using % & and key

• Refund entry

• No sale

• Paid-out entries

• Received on account entries

• Printing non-add code number

• Making corrections

• Checking sales report

For details of sales entry method, refer to BASIC SALES ENTRY (

page 12 ) and OPTIONAL FEATURES

( page 21 ). For details of correcting sales entries, refer to CORRECTION (

page 25 ). For details on reading

sales information, refer to READING (X) AND RESETTING (Z) OF SALES TOTAL ( page 57 ).

Things to do after you close your store:

• Print sales reports, and clear sales data for the day.

• Print Electronic Journal (EJ) reports, and clear Electronic Journal (EJ) data, if necessary.

• Account money - comparing it with the amount in cash in drawer printed on the general report.

• Remove the drawer for safety.

• Turn the mode switch to OFF position.

For details of reading sales information, refer to READING (X) AND RESETTING (Z) OF SALES TOTAL (

page

57 ) and EJ REPORT READING AND RESETTING ( page 60 ). For details of removing the drawer and

maintenance details, refer to OPERATOR MAINTENANCE (

page 62 ).

11

12

BASIC SALES ENTRY

1

Basic Sales Entry Example

Listed below is a basic sales entry example when selling department items by cash. For operation details, please refer to each section.

Mode switch setting

1.

Turn the mode switch to the REG position.

Clerk assignment

2.

Enter your clerk code. (For example, clerk code is 1. Press the 1 and L key in this order.) The clerk code 1 is automatically selected just after initialization of the cash register.

OPX/Z

OFF

VOID

PGM

REG

MGR

X1/Z1

X2/Z2

Item entries

3.

Enter the price for the first department item. (For example, for 15.00, enter 15: , and press the appropriate department key.)

For department 17 to department 32, press the D key first before pressing the department key.

For department 33 and above, enter the department code using numeric keys, and press the d key, then enter the price and press the d key again.

4.

Repeat step 3 for all the department items.

Displaying subtotals

5.

Press the s key to display the amount due.

Finalizing the transaction

6.

Enter the amount received from the customer. (You can omit this step if the amount tendered is the same as the subtotal.)

7.

Press the A key, and the change due is displayed (when the amount received was not entered, the total amount is displayed) and the drawer is opened.

8.

Tear off the receipt and give it to the customer with his or her change.

9.

Close the drawer.

Clerk assignment

Item entries

Displaying subtotal

Key operation example

1

L

1500

!

2300

" s

Finalizing the transaction

5000

A

(In this example, the tax rate is set to 6.25%.)

Print

Graphic logo

Date/Time/Clerk code number

Register number

/Consecutive number/Clerk name

Items

Price

Merchandise subtotal

Tax amount

Not printed when non-taxable items only are sold.

Tax status (T1: taxable 1)

Total quantity

Total amount

Cash tendering/amount received

Change

Clerk assignment

Prior to any item entries, clerks must enter their clerk codes into the register. However, the code entry may not be necessary when the same clerk handles the next transaction.

■ Sign-on (in REG, MGR, VOID mode) ■ Sign-off (in REG, MGR, VOID mode)

To display the signed-on clerk code

Clerk code 1 to 25

L L L

Receipt ON/OFF function

When you use the printer to issue receipts, you can disable receipt printing in the REG mode to save paper using the receipt ON/OFF function. To disable receipt printing, press the R

key in the OP X/Z position. This key toggles the receipt printing status ON and OFF.

To check the receipt printing status, turn the mode switch to the OP X/Z position or press the l

key in the REG mode. When the function is in the OFF status, the receipt off indicator “_” is illuminated. Your register will print reports regardless of the receipt state, so the paper roll must be installed even when the receipt state is “OFF”.

To issue a receipt when receipt ON/OFF function is set to OFF:

If your customer wants a receipt after you finalized a transaction with the receipt ON/OFF function being OFF status, press the R

key. This will produce a receipt. However, if more than 30 items were entered, the receipt will be issued in the format of summary receipt print.

Power Save Mode

The register will enter into power save mode when no entries are performed based on the pre-programmed time limit (by default, 30 minutes).

When your register goes to the power save mode, it will light off all the display except the decimal point at the leftmost position. Your register will return to the normal operation mode when any key is pressed or a mode is changed with the mode key. Please note when your register is recovered by a key entry, its key entry is invalid.

After the recovery, start the key entry from the beginning.

2

Error Warning

In the following examples, your register will go into an error state accompanied with a warning beep and the error symbol “ ” on the display. Clear the error state by pressing the l

key and take proper action.

Please refer to the error code table on page 67 .

• You enter over a 32-digit number (entry limit overflow): Cancel the entry and re-enter the correct number.

• You make an error in key operation: Clear the error and continue operation.

• You make an entry beyond a programmed amount entry limit: Check to see if the entered amount is correct. If it is correct, it can be rung up in the MGR mode. Contact your manager.

• An including-tax subtotal exceeds eight digits: Delete the subtotal by pressing the l key and press the A ,

C or c key to finalize the transaction.

Error escape function

When you want to quit a transaction due to an error or an unforeseen event, use the error escape function as shown below:

Transaction

To clear the error state l

E E

The transaction is voided (treated as a subtotal void) and the receipt is issued by this function. If you have already entered a tendered amount, the operation is finalized as a cash sale.

13

3

Item Entries

Single item entries

Department entries

The cash register provides a maximum of 99 departments for a merchandise classification. Group attributes, such as taxable status, are applied on items when they are entered to the departments.

• When using the department keys (for department 1 to 32)

For department 1 to 16, enter a unit price and press a department key. If you use a programmed unit price, press a department key only.

For department 17 to 32, enter a unit price, press the D

key and press a department key. If you use a programmed unit price, press the D

key and press a department key.

When using a programmed unit price

Unit price *

1

(max. 7 digits)

* 2

D

Department key

* 1 Less than the programmed upper limit amounts

When zero is entered, only the sales quantity is added.

* 2 For the optional departments 17 through 32, press the D

key.

• When using the department code entry key

Enter a department(dept.) code and press the d

key, then enter a unit price and press the d

key again. If the dept. code is programmed to preset price entry style and a unit price is preset, your cash register will finish its registration operation.

Dept. code

(1 to 99)

When using a programmed unit price d

Unit price *

1

(max. 7 digits) d

(In case only preset price entry is allowed.)

* 1 Less than the programmed upper limit amounts

When zero is entered, only the sales quantity is added.

14

PLU/subdepartment entries

For another merchandise classification, the cash register provides a maximum of 1200 PLUs/subdepartments.

PLUs are used to call up preset prices by a code entry. Subdepartments are used to classify merchandise into smaller groups under the departments. Every PLU and subdepartment has a code form 1 to 1200, and should belong to a department to obtain attributes of that department.

The cash register is pre-programmed to PLU mode and zero for unit price. To use PLU entries, their preset unit

prices should be previously programmed. (Refer to page 33 .)

To use subdepartment entries, change to subdepartment mode for the PLU codes.

• PLU entries

PLU code

(1 to 1200) p

• Subdepartment (open PLU) entries

PLU code

(1 to 1200) p

Unit price *

(max. 7 digits) p

* Less than the programmed upper limit amounts

When zero is entered, only the sales quantity is added.

Key operation example

Department entry

PLU entry

Subdepartment entry

1200

(

500

D !

)

D "

50 d

1500 d

33 d

2 p

11 p

1200 p

A

Print

Repeat entries

You can use this function for entering a sale of two or more of the same items. Repeat pressing a department key, d key or p key as shown on key operation example.

Key operation example Print

Department entry

PLU entry

Subdepartment entry

1200

( (

500

D !

!

) )

D " "

50 d

1500 d d

33 d d

2 p p

11 p

1200 p p

A

Multiplication entries

When you sell a large quantity of items, it is convenient to use the multiplication entry method. Enter quantity using numeric keys and press the @ key before starting item entry as shown in the example below.

When programmed to allow fractional quantity entries, you can enter up to four integers and three digit decimal, though the quantity is counted as one for sales reports. To enter a fractional quantity, use the decimal point key between integer and decimal, as 7P5 for entering 7.5.

15

Key operation example

Department entry

PLU entry

Subdepartment entry

3

@

1200

(

5

@

500

D !

3

@ )

5

@ D "

3

@

50 d

1500 d

5

@

33 d

3

@

2 p

5

@

11 p

1200 p

A

Print

16

Split pricing entries

This function is practical when the customer wants to purchase items normally sold in bulk.

To realize this function, you must change the programmed setting. Refer to “Various Function Selection

Programming 1” (job code 70) for programming details.

To make split pricing entries, follow the procedure below:

Selling q'ty

(Up to 4 digits)

@

Base q'ty

(Up to 2 digits)

When using a programmed unit price

@

Unit price per base q'ty D

Dept. code d

Department key

Unit price per base q'ty d

(Only preset entry is allowed.)

PLU code

PLU code p p

Unit price per base q'ty p

Key operation example

Department entry

PLU entry

7

@

10

@

600

*

8

@

12

@

35 p

A

Print

Single item cash sale (SICS) entry

• This function is useful when a sale is for only one item and is for cash. This function is applicable only to those departments that have been set for SICS or to their associated PLUs or subdepartments.

• The transaction is complete and the drawer opens as soon as you press the department key, d key or p key.

Print Key operation example

For finishing the transaction

250

,

If an entry to a department or PLU/subdepartment set for SICS follows the ones to departments or

PLUs/subdepartments not set for SICS, it does not finalize and results in a normal sale.

4

Displaying Subtotals

The register provides three types of subtotals:

Merchandise subtotal

Press the m key at any point during a transaction. The net sale subtotal - not including tax - will appear in the display.

Taxable subtotal

Taxable 1 subtotal

Press the

T and s keys in this order at any point during a transaction. The sale subtotal of taxable 1 items will appear in the display.

Taxable 2 subtotal

Press the

U and s keys in this order at any point during a transaction. The sale subtotal of taxable 2 items will appear in the display.

Including-tax subtotal (full subtotal)

Press the s key at any point during a transaction. The sale subtotal including tax and the symbol “ ” will appear in the display.

5

Finalization of Transaction

Cash or check tendering

Press the s key to get an including tax subtotal, enter the amount tendered by your customer, then press the A key if it is a cash tender or press the C key if it is a check tender. When the amount tendered is greater than the amount of the sale, your register will show the change due amount and the symbol “ ” will light up. Otherwise the register will show a deficit and the symbol “ ” will light up. You now must make a correct tender entry.

Cash tendering

Key operation example Print s

1000

A

17

Check tendering

Key operation example s

1000

C

Print

Cash or check sale that does not require entry

Enter items and press the

A key if it is a cash sale or press the

C if it is a check sale. Your register will display the total sale amount.

Print Key operation example

300 +

10 p

A

In the case of check sale

Charge (credit) sale

Enter items and press the charge key ( c

).

Key operation example

2500 +

3250 * c

Print

18

Mixed-tender sale

You can perform mixed-tendering of check and cash, cash and charge, and check and charge.

Example: Your customer pays $9.50 in cash and $40.00 by charge for an including-tax subtotal of $49.50.

Key operation example Print s

950

A c

6

Tax Calculation

Automatic tax

When the register is programmed with a tax rate (or tax table) and the tax status of an individual department is set for taxable, it computes the automatic tax on any item that is entered directly into the department or indirectly via a related PLU.

Example: Selling five $6.70 items (dept. 1, taxable 1) and one $7.15 item (PLU no. 85, taxable 2) for cash

Key operation example Print

5 @ 670 !

85 p

A

Manual tax

The machine allows you to enter tax manually after it finalizes an item entry.

Example: Selling an $8.00 item (dept. 12) for cash with 50 cents as tax

Key operation example Print

800 (

50 t

A

Tax delete

You can delete the automatic tax on the taxable 1 and taxable 2 subtotal of each transaction by pressing the t key after the subtotal is displayed.

To delete taxable 1 subtotal, press T , s to get taxable 1 subtotal, and then press t to delete the subtotal.

To delete taxable 2 subtotal, press U , s to get taxable 2 subtotal, and then press t to delete the subtotal.

To delete all taxable (1-4) subtotal, press T , U , s and t in this order.

Example: Selling a $7.25 item (dept. 1, taxable 1) and another $5.15 item (dept. 11, taxable 2) for cash and entering the sale as a non-taxable one

Key operation example Print

725 !

515 /

T s t

U s t

A

19

20

Tax status shift

The machine allows you to shift the programmed tax status of each department or the PLU key by pressing the

T and/or

U keys before those keys. After each entry is completed, the programmed tax status of each key is resumed.

Example: Selling the following items for cash with their programmed tax status reversed

• One $13.45 item of dept. 16 (non-taxable) as a taxable 1 item

• One $7.00 item of PLU no. 25 (non-taxable) as a taxable 1 and 2 item

• One $4.00 item of dept. 11 (taxable 2) as a non-taxable item

• Two $10.50 items of dept. 1 (taxable 1) as taxable 2 items

Key operation example Print

1345 T <

25 T U p

400 U /

1050 T U !

!

A

When Canadian tax system is applied:

When using a tax status shift, the entry of a multi-taxable item for PST or GST will be prohibited.

Please see below:

In case of; Tax 1: PST, Tax 2: PST,

Tax 3: PST, Tax 4: GST

Taxable 1 and 2 item ········· prohibited

Taxable 1 and 3 item········· prohibited

Taxable 2 and 3 item ········· prohibited

Taxable 1 and 4 item ············· allowed

Taxable 2 and 4 item ············· allowed

Taxable 3 and 4 item ············· allowed

In case of; Tax 1: PST, Tax 2: PST,

Tax 3: GST, Tax 4: GST

Taxable 1 and 2 item ········· prohibited

Taxable 1 and 3 item ············· allowed

Taxable 2 and 3 item ············· allowed

Taxable 1 and 4 item ············· allowed

Taxable 2 and 4 item ············· allowed

Taxable 3 and 4 item ········· prohibited

OPTIONAL FEATURES

1

Auxiliary Entries

Discount and premium entries using the percent key

The percent key is used to apply a manually entered or preset discount or premium percent rate to individual items or to a merchandise subtotal. In the default setting, you can manually enter a discount percent rate to both individual items and merchandise subtotal. For manual entry of discount or premium percent rate, enter the rate (up to 100.00) with the numeric keys (you need a decimal point when you enter a fractional percent rate), and press a percent key. When using a preset rate (if programmed), just press a percent key.

When entry limit is programmed for a percent key, you can not enter a rate over the limit (error code 34 will occur.)

Percent calculation for the merchandise subtotal

Key operation example

4 @

140 >

570 * m

10 %

A

Print

Percent calculation for item entries

Key operation example

800 +

7 P 5 %

15 p

&

A

(When premium and 15% are programmed for the

& key)

Print

Discount and premium entries using the discount key

The discount key is used to apply a manually entered or preset discount or premium amount to individual items or to a merchandise subtotal. In the default setting, you can manually enter a discount amount to both individual items and merchandise subtotal. For manual entry of discount or premium amounts, enter the amount with the numeric keys, and press the discount key. When using a preset amount (if programmed), press the discount key.

When entry digit limit is programmed for the discount key, you can not enter an amount over the limit (error code

34 will occur.)

21

Discount for the merchandise subtotal

Key operation example

575 +

10 p m

100 -

A

Discount for item entries

Key operation example

675 *

-

A

(When a discount amount of

$0.75 is programmed.)

Print

Print

Refund entries

For departments 1 to 16, enter the refund amount and press the f key, and then press the corresponding department key and for departments 17 to 32, enter the refund amount and press the f key, then press the

D key and press the corresponding department key (when using the preset price, omit entering the amount).

In case of department 33 to 99, enter the department code and press f key and the d key, then enter the refund amount and press the d key if necessary.

For a refund of a PLU item, enter the PLU code and press the f key, then press the p key.

For a refund of a subdepartment item, enter the PLU code and press the f key and p key, then enter the refund amount and press the p key.

Print Key operation example

250 f +

33 f d 100 d

7 @

13 f p

15 f p 150 p

A

22

Non-add code number entries and printing

You can enter a non-add code number such as a customer’s code number and credit card number, a maximum of 16 digits, at any point during the entry of a sale. The cash register will print it at once.

To enter a non-add code number, enter the number and press the s key.

Key operation example

1230 s

1500 + c

Print

2

Auxiliary Payment Treatment

Currency conversion

The register allows payment entries in a foreign currency (only cash payment is available). Pressing the

V key creates a subtotal in the foreign currency.

When using a programmed currency conversion rate, press the

V key after item entries, then enter the tendered amount in foreign currency if not exact amount payment, and press the

A key.

When making a manual entry of currency conversion rate, after item entries, enter the conversion rate (0.0000 to

9999.9999; you need a decimal point when you enter fractional conversion rate) and press the

V key, then enter the tendered amount in foreign currency if not exact amount payment, and press the

A key.

In both cases, the change due will be displayed in domestic currency, and when the amount tendered is short, the deficit is shown in domestic currency.

• Press the l key after pressing the

V key to cancel payment in a foreign currency.

• If programmed, a foreign currency symbol is printed when you use a prest rate.

Applying preset conversion rate

Key operation example

Currency conversion

Amount tendered in foreign currency

2300

+

4650

*

V

10000

A

(When a currency conversion rate of 0.7674 is programmed for the V key.)

Print

Domestic currency

Conversion rate

Foreign currency

Domestic currency

Applying manual conversion rate

Key operation example

Conversion rate

2300

+

4650

*

1

P

275

V

10000

A

Foreign currency symbol

(Printed if programmed)

Print

23

24

Received-on Account and Paid-out Entries

When you receive on account from a customer or when you pay an amount to a vendor, it is a good idea to use the r key or the

R key respectively.

For the received-on-account (RA) entry, enter the amount, and press the r key.

For the paid-out (PO) entry, enter the amount and press the

R key.

Cash tendering only available for RA and PO operation.

Key operation example

12345 s

4800 r

Print

No sale (exchange)

When you need to open the drawer with no sale, just press the

A key. The drawer will open and printer will print “NO SALE” on the receipt or journal. If you let the machine print a non-add code number before pressing the

A key, a no sale entry is achieved and a non-add code number is printed.

3

Automatic Sequence Key (

a

key) Entries

You can achieve a programmed transaction simply by pressing the a key.

Key operation example Print a

( a = 500 * A )

CORRECTION

1

Correction of the Last Entry (direct void)

If you make an incorrect entry relating to a department, PLU/subdepartment, percentage ( % and & ), discount

( ) or refund, you can void this entry by pressing the v key immediately after the incorrect entry.

Print Key operation example

1250 + v

2 p v

600 '

& v

328 ,

28 v

250 f + v

A

2

Correction of the Next-to-last or Earlier Entry (indirect void)

You can void any incorrect department entry, PLU/subdepartment entry or item refund entry made during a transaction if you find it before finalizing the transaction (e.g. pressing the

A key). This function is applicable to department, PLU/subdepartment and refund entries only.

For the operation, press the v key just before you press a department key, d key or p key. For the refund indirect void, press the v key after you press the f key.

Key operation example

Correction of a department entry

Correction of a PLU entry

Correction of a refund entry

1310

+

1755

*

10 p

12 p

250 f +

825

*

1310 v +

12 v p

250 f v +

A

Print

25

26

3

Subtotal Void

You can void an entire transaction. Once subtotal void is executed, the transaction is aborted and the register issues a receipt. This function does not work when more than 30 items have been entered.

Key operation example

Subtotal void

1310

"

"

1755

+

10 p

35 p s v s

Print

4

Correction of Incorrect Entries not Handled by the Direct or Indirect Void

Function

Any errors found after the entry of a transaction has been completed or during an amount tendered entry cannot be voided. These errors must be corrected by the manager.

The following steps should be taken:

1.

If you are making the amount tendered entry, finalize the transaction.

2.

Make correct entries from the beginning.

3.

Hand the incorrect receipt to your manager for its cancellation.

FOR THE MANAGER

PRIOR TO PROGRAMMING

Before starting sales entries, you must first program necessary items so that the cash register suits your sales manner. In this manual, there are three sections, BASIC FUNCTION PROGRAMMING where required items must be programmed , AUXILIARY FUNCTION PROGRAMMING where you can program for more convenient use of keys on the keyboard, and ADVANCED FUNCTION PROGRAMMING where various optional programming features are provided. Find the appropriate features for your needs, and make the necessary programming.

You can select the language of text (English, French or Spanish) printed on receipts or journals.

For the language selection, please refer to “Language Selection” described later in this section.

Procedure for programming

1.

Check to see whether a paper roll is present in the machine. If there is not enough paper on the roll, replace it with a new one (refer to MAINTENANCE section for the replacement).

2.

Put the manager key in the mode switch and turn it to the PGM position.

3.

Program necessary items into the cash register.

Every time you program an item, the cash register will print the setting. Please

OPX/Z

OFF

VOID

REG

MGR

X1/Z1

X2/Z2 refer to print samples in each section.

4.

If necessary, issue programming reports for your reference.

PGM

• On the procedures and key operation examples shown in the programming details, numbers such as “08262005” indicates the parameter which must be entered using the corresponding numeric keys.

• Asterisks in the tables shown in the programming details indicate default settings.

BASIC FUNCTION PROGRAMMING

(For Quick Start)

1

Date and Time Programming

Date

For setting the date, enter the date in 8 digits using the month-day-year (MM/DD/YYYY) format, then press the s key.

Date(MM/DD/YYYY)

Key operation example

08262005 s

(Aug. 26, 2005) s

Print

Date

You can use the date format of day-month-year (DD/MM/YYYY) or year-month-day (YYYY/MM/DD) format. To change the format, refer to “Various Function Selection Programming 1” section (Job code 61).

27

Time

For setting the time, enter the time in 4 digits using the 24-hour format. For example, when the time is set to

2:30 AM, enter 230; and when it is set to 2:30 PM, enter 1430.

Time(max. 4 digits in 24-hour format) s

Key operation example

1430 s

Print

Time

In the display, current time is displayed in 12-hour format. For AM time, “ ” and for PM time “ ” will appear in the rightmost position with the current time. If you want to display time in the 24-hour format, refer to “Various Function Selection Programming 1” section (Job code 61).

28

2

Tax Programming for Automatic Tax Calculation Function

The cash register can support US and Canadian tax systems. If you use the Canadian tax system, you must first change the tax system, then program the tax rate or tax table and quantity for doughnut exempt which are described in this section. For changing your cash register’s tax system, please refer to “Various Function Selection Programming 1” section (job code 70).

Before you can proceed with registration of sales, you must first program the tax that is levied in accordance with the law of your state. The cash register comes with the ability to program four different tax rates. In most states, you will only need to program Tax 1. However if you live in an area that has a separate local tax (such as a Parish tax) or a hospitality tax, the register can be programmed to calculate these separate taxes.

When you program the tax status for a department, tax will be automatically added to sales of items assigned to the department according to the programmed tax status for the department. You can also enter tax manually.

There are two tax programming methods. The tax rate method uses a straight percentage rate per dollar. The tax table method requires tax break information from your states or local tax offices. Use the method which is acceptable in your state. You can obtain necessary data for tax programming from your local tax office.

Tax programming using a tax rate

The percent rate specified here is used for tax calculation on taxable subtotals.

s 9 @

Tax number (1 to 4)

@

Tax rate

(0.0000 to 100.0000)

When the lowest taxable amount is zero

@ Lowest taxable amount

(0.01 to 999.99)

To delete a tax rate, use the following sequence: s 9 @

Tax number (1 to 4)

@ s A v A

Example: Programming the tax rate 4% as tax rate 2 with tax exempt as 12¢

Key operation example Print s 9 @

2 @

4 @

12 s

A

• If you make an incorrect entry before pressing the third @ key in programming a tax rate, cancel it with the l key.

• You do not need to enter the trailing zeros of the tax rate (after the decimal point), but you do need to enter the decimal for fractions.

• The lowest taxable amount setting is ignored when you select VAT system for Canadian tax.

The tax table (applicable to the add-on tax)

If you are in an area that uses a tax table for tax calculation, you can program the cash register accordingly. Tax table programming can be performed for Tax 1 through Tax 4.

Sample tax table

New Jersey tax table: 6%

.05

.06

.07

.08

.09

.10

.11

Taxes

.00

.01

.02

T

.03

.04

.12

.13

Range of sales amount

Minimum breakpoint

.01

to

Maximum breakpoint

.10

.11

.23

Q to to

.22

.38

.39

.57

to to

.56

.72

.73

.89

1.11

1.23

1.39

1.57

1.73

1.89

2.11

M1

M2 to to to to to to to to to

.88

1.10

1.22

1.38

1.56

1.72

1.88

2.10

2.22

A: Difference between the minimum breakpoint and the next one (¢)

10 (0.11 - 0.01)

12 (0.23 - 0.11)

16 (0.39 - 0.23)

18 (0.57 - 0.39)

16 (0.73 - 0.57)

16 (0.89 - 0.73)

22 (1.11 - 0.89)

12 (1.23 - 1.11)

16 (1.39 - 1.23)

18 (1.57 - 1.39)

16 (1.73 - 1.57)

16 (1.89 - 1.73)

22 (2.11 - 1.89)

B: Non-cyclic

C: Cyclic-1

D: Cyclic-2

To program a tax table, first make a table like the one shown above right.

From the tax table, calculate the differences between a minimum break point and the next one (A). Then, from the differences, find irregular cycles (B) and regular cycles (C and D). These cycles will show you the following items necessary to program the tax table:

T: The tax amount collected on the minimum taxable amount (Q)

Q: The minimum taxable amount

M1: The maximum value of the minimum breakpoint on a regular cycle (C)

We call this point “MAX point.”

M2: The maximum value of the minimum breakpoint on a regular cycle (D)

We call this point “MAX point.”

M: Range of the minimum breakpoint on a regular cycle: difference between Q and M1 or between M1 and M2

29

30

s 8

T max. three digits

@

@

One- or two-

*1 digit number

Q max. five digits

@

@

Rate

*2 max. six digits

(0.0001 - 99.9999%)

@

M max. four digits

@

Minimum breakpoint max. five digits

@

Repeat until the MAX point is entered.

A

To delete a tax table, use the following sequence: s 8 @

One- or two-

*1 digit number

@

Rate

*2 max. six digits

(0.0001 - 99.9999%)

@

M max. four digits

@ s

*1 First figure:

(1 or 0)

The first figure to be entered depends upon whether the difference between a minimum breakpoint to be entered and the preceding minimum breakpoint is not less than $1.00 or more than 99¢. When the difference is not less than $1.00, enter “1,” and when it is not more than 99¢, enter “0” or nothing.

Second figure:

(1 to 4)

The second figure depends upon whether your tax table is to be programmed as tax table 1,

2, 3 or 4.

*2 If the rate is fractional (e.g. 4-3/8%), then the fractional portion (3/8) would be converted to its decimal equivalent (i.e. .375) and the resulting rate of 4.375 would be entered. Note that the nominal rate (R) is generally indicated on the tax table.

If you make an incorrect entry before entering the M in programming a tax table, cancel it with the l key; and if you make an error after entering the M, cancel it with the s key. Then program again from the beginning.

• Limitations to the entry of minimum breakpoints

The register can support a tax table consisting of no more than 72 breakpoints. (The maximum number of breakpoints is 36 when the breakpoint difference is $1.00 or more.) If the number of breakpoints exceeds the register’s table capacity, then the manual entry approach should be used.

Example: Programming the sample tax table shown on the previous page as tax table 1

Key operation example Print

Tax rate

M

T

Q

The first cyclic portion

M1

(MAX point) s

8

@

1

@

6

@

100

@

1

@

11

@

23

@

39

@

57

@

73

@

89

@

111

@

A

You do not need to enter the trailing zeros of the tax rate (after the decimal point) but you do need to enter the decimal point for fractions.

• If the tax is not provided for every cent, modify the tax table by setting the tax for every cent in the following manner.

When setting the tax, consider the minimum breakpoint corresponding to unprovided tax to be the same as the one corresponding to the tax provided on a large amount.

Modification of the left tax table

.06

.09

.10

.11

.12

.14

.17

.00

.01

.02

.03

.04

Sample tax table

Example 8%

Tax

Minimum breakpoint

.89

1.11

1.26

1.47

1.68

1.89

2.11

.01

.11

.26

.47

.68

Tax

.05

.06

.07

.08

.09

.10

.11

.12

.00

.01

.02

.03

.04

.13

.14

.15

.16

.17

T

Minimum breakpoint

.89

.89

1.11

1.11

1.11

1.26

1.47

1.68

.01

.11

.26

.47

.68

1.89

1.89

2.11

2.11

2.11

Q

M1

M2

Breakpoint difference (¢)

1

10 (0.11-0.01)

15 (0.26-0.11)

21 (0.47-0.26)

21 (0.68-0.47)

21 (0.89-0.68)

0 (0.89-0.89)

22 (1.11-0.89)

0 (1.11-1.11)

0 (1.11-1.11)

15 (1.26-1.11)

21 (1.47-1.26)

21 (1.68-1.47)

21 (1.89-1.68)

0 (1.89-1.89)

22 (2.11-1.89)

0 (2.11-2.11)

0 (2.11-2.11)

B: Non-cyclic

C: Cyclic-1

D: Cyclic-2

From the modified tax table above;

Rate = 8(%), T = $0.01 = 1¢, Q = $0.11 = 11¢, M1 = 1.11, M2 = 2.11, M = 100

Quantity for doughnut tax exempt (for Canadian tax system)

This option is available only when the Canadian tax system is selected.

s 19 @

To program zero

Q’ty for doughnut tax exempt

(max. 2 digits: 1 to 99) s A

Example: To program the quantity “6”

Key operation example s 19 @

6 s

A

Print

31

AUXILIARY FUNCTION PROGRAMMING

1

Department Programming

Merchandise can be classified into a maximum of 99 departments. Items sold with use of the department keys can later be printed on a report that shows the quantities sold and sales amounts classified by department. The data is useful for making purchasing decisions and other store operations. Departments can be assigned to articles whose prices were set using PLU/subdepartment function.

When using a department key, you must set the parameters to specify the department status, such as positive or negative department. Prices can be assigned directly to departments for frequently purchased items, which enables you to enter the prices by simply pressing the department keys or dept. code entries.

Department status

To set all zeros

ABCDEFGH

*

D

@

Dept. key

A

*To program departments 17 through 32, press the department shift key at this point.

For department 33-99:

Dept. code d

To set all zeros

ABCDEFGH

@ A

To program another department, start from the beginning without pressing the A key.

Item:

A Tax 4 status

B

C

D

E

F

G

H

Tax 3 status

Tax 2 status

Tax 1 status

SICS / Normal

Sign

Entry digit limit

Type of unit price entry

Selection:

Taxable

Non-taxable*

Taxable

Non-taxable*

Taxable

Non-taxable*

Taxable (*for dept. 1 thru 10)

Non-taxable (*for dept. 11 thru 99)

SICS

Normal*

Negative department

Positive department*

Open and preset

Preset only

Open only*

Inhibit department key

Entry:

1

0

1

0

1

0

1

0

1

0

1

0

0-7 (default: 7)

1

0

3

2

Tax status (taxable 1 through 4 / non-taxable)

• When any entry of a taxable department is made in a transaction, tax is automatically computed according to the associated tax table or rate.

SICS (Single Item Cash Sale)

• If an entry of a department programmed for SICS is made first, the sale will be finalized as a cash sale as

32

soon as the department key is pressed. If the entry is made after entering a department not programmed for

SICS, the sale will not be finalized until the A key is pressed.

Entry digit limit

• Set the number of allowable digits for the maximum entry amount for each department. The limit is effective for operations in the REG mode and can be overridden in the MGR mode.

Example: Programming department 2 as taxable 1, SICS, negative department, entry digit limit - 7 digits, and allowing open & preset entry. (ABCDEFGH: 00011173)

Key operation example Print

00011173 @

" A

From left, EGH

Tax status Sign(F)

Preset unit price

To program zero

Unit price

(max. six digits)

*

D

Dept. key

A

*To program departments 17 through 32, press the department shift key at this point.

For department 33-99:

Dept. code d

To program zero

Unit price

(max. six digits) s A

To program another department, start from the beginning without pressing the A key.

Print Key operation example

1000 !

A

Unit price

Even if a department is not programmed to allow the entry of preset unit prices in functional programming, the department is automatically changed to allow the entry of preset unit prices by this programming entry.

2

PLU (Price Look-Up) and Subdepartment Programming

The PLU function allows speedy key entries whereby a price is automatically called up when a code is entered.

The subdepartment is a kind of “open PLU”, which requires you to enter a price after the PLU code is entered. A maximum of 1200 PLU/subdepartment settings are possible. Each one belongs to a department and acquires the department’s parameters (tax status, SICS and sign).

The cash register is preprogrammed so all 1200 codes are assigned as PLUs associated with department 1 and preset unit price “0”.

33

34

Unit price and associated department assignment

*

2

PLU code p

To program zero

* 3

Unit price

(max. six digits)

* 1

D

Associated

Dept. key

A

*1: To assign departments 17 through 32, press the department shift key at this point.

When the associated department is department 33-99:

To program zero

* 2 PLU code p Associated dept. code

(1 to 99) d * 3 Unit price

(max. six digits) s A

*2: 1 through 1200 (Depending on the EJ memory size setting, up to 200)

*3: For a subdepartment, set the limit amount of unit price entry.

To program the following PLU, start from entering a unit price or an associated department code without pressing the A key.

To program another PLU, start from the beginning without pressing the A key.

Key operation example

1 p

125 #

A

Print

Unit price

Associated dept.

PLU code

To delete a PLU code, use the following sequence:

PLU code p v

To delete the following PLU

A

To delete another PLU

PLU/subdepartment selection

* 1 PLU code p

To program "0"

* 2 A s

To program the following PLU

To program another PLU

*1: 1 through 1200 (Depending on the EJ memory size setting, up to 200)

*2: 0 for subdepartment or 1 for PLU (default: 1)

Print Key operation example

1 p

0 s A

A

PLU/subdept.

When you program the last PLU code, the programming sequence will be complete with a press of the s key.

3

Miscellaneous Key Programming

The cash register provides miscellaneous keys such as % , & , , f , r , R , V , t , C , c and

A . While the cash register is pre-programmed so you can use these keys, you must set a currency conversion rate to use V key. You can also program these keys for more convenient use. Please refer to the data below for programming these keys. Factory setting is indicated with parentheses.

%

f r

V

,

,

&

R

Percent rate (0.00%), tax status (non-taxable), sign (minus), item % and subtotal % entry* (both are allowed), percent rate limitation (100 %)

Amount (0.00), tax status (non-taxable), sign (minus), item _ and subtotal _ entry*

(both are allowed), entry digit limit (7 digits)

Not necessary to program

Entry digit limit (9 digits)

Currency conversion rate (0.0000), currency conversion rate entry method - open or preset (both are enabled)

C , c and A Compulsory entry of amount tender (not compulsory), entry digit limit (8 digits), footer printing (not printed) t (Manual tax) Entry digit limit (7 digits)

* Item %/Item _ : Percent/discount calculation is applied to individual department and

PLU/subdepartment.

* Subtotal %/Subtotal _ : Percent/discount calculation is applied to subtotals.

Rate for

%

,

&

and

V

To program zero

*Rate

% or

&

V

To program another rate

*: Rate

0.00 — 100.00 (% rate)

0.0000 — 9999.9999 (Currency conversion rate)

Key operation example

10 P 25 %

0 P 7674 V

A

A

Print

Percent rate

Currency conversion rate

You must use a decimal point when setting fractional rates.

35

36

Amount for

-

To program zero

Discount amount (max. six digits)

Key operation example

200 -

A

A

Print

Discount amount

Percent rate limitation for

%

and

&

To program zero s 29 @

Percentage limit (0.00 -100.00%)

A

To program for another percent key

• Percent entries that exceed the upper limit may be overridden in the MGR mode.

• 10.00% can be entered as

10 or

10P00

. The

P key is needed only for fractional entry.

Print Key operation example s 29 @

15 P 00 %

A

Percentage limit

Function parameters for

%

,

&

and

-

To program “0” for all items

*ABCDEFGH

@ % or

&

-

To program for another key

A

*: Item:

A

B

C

D

Tax 4 status

Tax 3 status

Tax 2 status

Tax 1 status

Selection:

Taxable

Non-taxable*

Taxable

Non-taxable*

Taxable

Non-taxable*

Taxable

Non-taxable*

E

F

+/- sign

Item % / Item _

+ (premium) sign

- (discount) sign*

Allow*

Disallow

G Subtotal % / Subtotal _ Allow*

Disallow

H Entry digit limit for discount key

When programming for percent keys, always enter 0 for H.

Entry:

1

0

1

0

1

0

1

0

0

1

0

1

0

1

0-7 (default: 7)

Tax status (taxable 1 through 4 / non-taxable)

• When taxable is selected, tax is applied to the amount obtained after premium or discount calculation.

+/- sign

• Programming of the +/- sign assigns the premium or discount function for each key.

Entry digit limit (For discount key only)

• The entry digit limit is in effect for the REG mode operations but can be overridden in the MGR mode. The entry digit limit is represented by the number of allowable digit for the maximum entry amount for discount key.

Print Key operation example

00011006 @

- A

From left, FGH

Sign(E)

Tax status

Function parameters for

V

To program “0” for all items

*AB

@ V

*: Item:

A Open rate entry

B Preset rate entry

Selection:

Allow*

Disallow

Allow*

Disallow

A

Key operation example

00 @

V A

Print

Entry:

0

1

0

1

From left, AB

37

Entry digit limit for

r

,

R

and

t

Entry digit limit

@ r

,

R or t A

(only for manual entry)

• For r R

, enter 0 to 9 (digits), and for t

(manual tax), enter 0 to 7 (digits). By default, 9 for r

and

R and 7 for t

are set.

Entry digit limit is in effect for REG mode operation but can be overridden in the MGR mode. The entry digit limit is represented by the number of allowable digits for maximum entry or total amount. When “0” is set, the operation of the corresponding key is prohibited.

Print Key operation example

4 @

R A

38

Function parameters for

C

,

c

and

A

(when using as CA key)

To program “0” for all items

*

1

@

*

2 s

,

C c

To program for another key

A

*

2

:Press s

key for CA key setting.

* 1: Item: Selection: Entry:

A Footer printing Allow 1

Disallow* 0

B Amount tendered entry Compulsory 1

Non-compulsory (for the CA or CHK keys)* 0

Inhibit (for the CH key)* 0

C Entry digit limit 0-8 (default: 8)

Footer printing

• This programming decides whether or not the machine should print a message at the foot of a receipt when a specified media key is used. With regard to programming method of footer logo message, refer to “Logo

messages” section on page 43 .

Amount tendered entry

• You may select amount tendered, compulsory or optional, for the

A and

C keys.

• You may select amount tendered, compulsory or inhibited, for the c key.

Entry digit limit

• For the c and

C keys, program upper limit entry amount for the tendered amount. For the

A key, program upper limit entry for total cash amount which can be handled on the register. The entry digit limit is in effect for REG mode operation but can be overridden in the MGR mode. The entry digit limit is represented by the number of allowable digits for the maximum entry or total amount. When “0” is set, the operation of the corresponding key is prohibited.

Key operation example

018 @

C A

Print

ABC (A:0, B:1, C:8)

4

Text Programming

The register allows you to program the text for clerk names, department item names, PLU/subdepartment item names, and so on, if necessary. There are two ways for programming text: using character keys on the keyboard or entering character codes with numeric keys on the keyboard.

Using character keys on the keyboard

You can enter characters according to the small figures printed in the lower right position of the key tops. For

the layout, please refer to “Keyboard” section on page 5 .

The following are used as control keys for character entry:

H

Toggles between upper-case and lower-case letters. By default, the upper-case letter is selected.

Once the

H key is pressed, you are locked in for entering lower-case letters. “_” lights up at the

SHIFT position of the display when lower-case letters entry is selected.

N

Press the

N key to enter numeric characters. For example to enter “1”, press the

N and

1 key. If you press the

1 key without pressing the

N key, the cash register goes to character codes entry mode.

Once the

N key is pressed, you are locked in for entering numeric characters. “_” lights up at the

NUMBER position of the display when numeric characters entry is selected.

W

Toggles between single-size and double-size characters. By default, the single-size character is selected. Once the

W key is pressed, you are locked in for entering double size characters. “_” lights up at the DC position of the display when double-size characters entry is selected.

B

Backs up the cursor, erasing the character to the left.

To program the word “Clerk01” with the letter “C” being double size.

To make the letter “C” double size character

To make character size return to normal size

To toggle the characters to lower-case letters

To enter numbers

W g

W

H h i j k

N 0 1

Entering character codes with numeric keys on the keyboard

Numerals, letters and symbols are programmable by entering the character code and the

: key. (If numeric characters entry is selected, that is, “_” lights up at the NUMBER position of the display, press the

N key to release it.) Set the alphanumeric character code table on the next page. By doing this, you can program characters other than those on the key tops.

• Double-size characters can be made by entering the character code 253.

• All three digits of the character code MUST be entered (even if it starts with zero).

To program the word “SHARP” in double-size characters

253

:

083

:

072

:

065

:

082

:

080

:

S H A R P

When you press an appropriate number key (job code number) and press the

P key for text entry just after you start programming with the s key, the cash register will be automatically ready for text entry.

Listed below is an overview of what you can program and the allowable number of single sized characters for each text entry.

• Department text

• PLU text (item label)

12 characters

12 characters

• Function text

• Logo message

8 characters

6 lines and 24 characters for each line

• Clerk name 8 characters

• Foreign currency symbol 4 characters

39

40

Alphanumeric character code table

035

036

037

038

039

030

031

032

033

034

040

041

042

043

044

045

025

026

027

028

029

020

021

022

023

024

015

016

017

018

019

010

011

012

013

014

Code

001

002

003

004

005

006

007

008

009

Character

á

â

ê

î

ó

û

ú

œ

í

ì

ô

ú

Ú

¨

ó

Ó

(space)

!

#

$

%

)

(

&

+

,

-

X

Y

Z

U

V

W

P

Q

R

S

T

K

L

M

N

O

F

G

H

I

J

C

D

E

>

?

@

A

B

;

:

9

<

=

Character

.

/

0

1

2

3

4

5

6

7

8

085

086

087

088

089

090

080

081

082

083

084

075

076

077

078

079

070

071

072

073

074

065

066

067

068

069

057

058

059

060

061

062

063

064

Code

046

047

048

049

050

051

052

053

054

055

056

130

131

132

133

134

135

122

123

124

125

126

127

128

129

117

118

119

120

121

112

113

114

115

116

107

108

109

110

111

102

103

104

105

106

Code

091

092

093

094

095

096

097

098

099

100

101 u v w x y p q r t s

¢

!!

}

ß

| z

{ k l m n o f g h d e j i

Character

Ä

Ö

Ü

^ a b c

_

1

2

3

4

1/2

F

T

*(DC): Double-size character code

: The shaded character cannot be displayed (displayed as space).

The character “!!” (code 128) cannot be displayed (displayed as “!”).

182

183

184

185

186

165

177

178

180

181

187

188

189

190

191

192

160

161

162

163

164

155

156

157

158

159

150

151

152

153

154

145

146

147

148

149

Code

136

137

138

139

140

141

142

143

144

Character

F

C

S

.

E e

I i

A a

Á

Í

U u

¿

ù

T

ç

°

à

Æ

ø

Å

¤

é

è

ò

£

¥

Pt i

Ñ

°

Code Character

.

193

194

.

I

G

195

232

233

234

235

236

237

238

253

227

228

229

230

231

218

219

224

225

226

213

214

215

216

217

208

209

210

211

212

203

204

205

206

207

196

197

198

199

200

201

202 g z

[

ä

ö

ü y

.

u n

§

Ø

æ

å

É

ñ

*(DC)

Z

D d

C c e s c

L l

P r

]

Department text

s 1 P

*

D

Dept. key

To keep current setting

Character keys

(max.12 digits)

Dept. code

(1 to 99) d

To program another dept.

*To program departments 17 through 32, press the department shift key.

Key operation example Print s 1 P

!

FRUIT s

A s

Text programmed for dept. 1

(Programming FRUIT for dept.1)

A

PLU text (item label)

s 2 P

PLU code p

To keep current setting

Character keys

(max.12 digits) s

When the next PLU code immediately follows the one just entered

To program another PLU

A

Key operation example s 2 P

1 p

MELON s

A

(Programming MELON to PLU1)

Print

Text programmed for

PLU code 1

Function text

s 3 P *Function no.

(max. 2 digits)

@

To keep the current setting

Character keys

(max. 8 digits)

To program another function text

* Function no.: See “List of function texts” shown on the following page.

s A

41

42

Key operation example s 3 P

46 @

CARD s

A

(Programming CARD for gross charge)

Print

List of function texts

Function no.

27

*

*

*

28

29

30

31

32

33

34

35

24

25

26

20

21

22

23

16

17

18

19

12

13

14

15

9

10

11

7

8

5

6

3

4

1

2

Key or function

Default setting

%1

%2

Net sales total

(–)

%1

%2

NET1

TAX1 ST Net taxable 1 subtotal

Gross tax 1 total GRS TAX1

Tax 1 total of refund entries RFD TAX1

Net tax 1 total TAX1

Exempt tax 1

Net taxable 2 subtotal

TX1 EXPT

TAX2 ST

Gross tax 2 total GRS TAX2

Tax 2 total of refund entries RFD TAX2

Net tax 2 total

Exempt tax 2

Net taxable 3 subtotal

TAX2

TX2 EXPT

TAX3 ST

Gross tax 3 total GRS TAX3

Tax 3 total of refund entries RFD TAX3

Net tax 3 total

Exempt tax 3

TAX3

TX3 EXPT

Net taxable 4 subtotal

Gross tax 4 total

TAX4 ST

GRS TAX4

Tax 4 total of refund entries RFD TAX4

Net tax 4 total TAX4

Exempt tax 4

Gross manual tax total

Refund manual tax total

Net manual tax total

Exempt total from GST

PST total

GST total

TX4 EXPT

GRS MTAX

RFD MTAX

M-TAX

GST EXPT

PST TTL

GST TTL

Tax total

Net

Sales total including tax total

TTL TAX

NET

NET2

Refund REFUND

Item void VOID

Function no.

59

60

61

55

56

57

58

51

52

53

54

47

48

49

50

66

67

68

69

62

63

64

65

44

45

46

40

41

42

43

36

37

38

39

Key or function

Void mode

Manager void

Subtotal void

No sale

RA

PO

Default setting

VOID

MGR VD

SBTL VD

NO SALE

RA

PO

Customer counter

Sales total

TRANS CT

NET 3

CASH

Cash

Check

Gross charge

Refund charge

CHECK

CHARGE

CHARGE–

Currency conversion1 (Preset) CONV 1

Currency conversion2 (Open) CONV 2

Cash in drawer CID

Cash+check in drawer

Check change

Exempt VAT

(+)Dept. total

(–)Dept. total

Subtotal

Merchandise subtotal

Total

Change

Items

Department report title

PLU report title

Transaction report title

Clerk report title

Hourly report title

Non add symbol

Copy receipt title

EJ report title

EJ report end title

CA+CH ID

CHK/CG

VAT EXPT

DEPT TL

DEPT(–)

SUBTOTAL

MDSE ST

TOTAL

CHANGE

ITEMS

DEPT

PLU

TRANS.

CLERK

HOURLY

#

COPY

EJ

EJ

END

• The items marked with “ * ” are for Canada only.

• The function no. 53 “Exempt VAT” is only effective for the Canadian tax system (2 GST, VAT type).

Clerk names

s 5 P Clerk code

(1-25)

@

To program another clerk

To keep current setting

Character keys

(max. 8 digits) s

Key operation example s 5 P

1 @

DAVID s

A

Print

A

Logo messages

The register can print programmed messages on every receipt. On the standard model, the graphic logo is printed on the receipt. If you want to print logo messages, please change the logo message print format. (See

page 51

for the programming details.) The options are listed below: s 4 P *Line number

(1-6)

@

To keep the current setting

Character keys

(max. 24 digits) s

To program another line

* “Header 3-line message” type: 1 to 3

“Footer 3-line message” type : 4 to 6

“Header 6-line message” type: 1 to 6

“Header 3-line and footer 3-line message” type: 1 to 6 (1 to 3 as header, 4 to 6 as footer)

Logo print format (6 types)

Graphic logo

Text 1st line

Text 2nd line

Text 3rd line

Graphic logo

Text 1st line

Text 2nd line

Text 3rd line

Graphic logo

Text 1st line

Text 2nd line

Text 3rd line

Text 4th line

Text 5th line

Text 6th line

Default setting Header 3-line message

Text 4th line

Text 5th line

Text 6th line

Footer 3-line message

Header 6-line message

A

Text 1st line

Text 2nd line

Text 3rd line

Text 4th line

Text 5th line

Text 6th line

Header 3-line message and footer 3-line messages

43

To print the logo message “THANK YOU” using double sized characters and centering on the third line.

Key operation example s 4 P

3 @

S S S

W THANK S YOU W

S S S s A

Print

A 6-line logo message is preprogrammed when shipped. Please start entering from the first line when you first program a logo message.

Foreign currency symbol

Foreign currency symbol for V key is printed with a foreign currency exchange amount.

To keep the current setting s 6 P Character keys

(max. 4 digits) s A

Key operation example

Entry using character code s

6

P

S S S

207

: s A

Print

Foreign currency symbol

44

ADVANCED PROGRAMMING

1

Register Number and Consecutive Number Programming

The register number and consecutive numbers are printed on every receipt or journal.

When your store has two or more registers, it is practical to set separate register numbers for their identification.

The consecutive number is increased by one each time a receipt is issued or when a journal print occurs.

For consecutive number programming, enter a number (max. 4 digits) that is one less than the desired starting number.

Register number

s 1 @

Key operation example s 1 @

123456 s A

To set the register number “0”

Register number (one to six digits)

Print s A

Register number

Consecutive numbers

s 2 @

Key operation example s 2 @

1000 s A

To begin the count from 0001

A number (one to four digits) that is one less than the desired starting number

Print s A

Consecutive number

2

Electronic Journal (EJ) Programming

The cash register provides the electronic journal (EJ) function. By default, a maximum of 2000 lines can be stored in memory. If you want to store more journal data, you can expand to a maximum of 3000 lines, although the maximum number of PLUs is decreased to 200 codes because the memory is shared with PLU settings.

You can also program various options for EJ, such as availability of EJ memory nearly full warning, availability of printing EJ data during a transaction, data type to be stored in memory, and printing format.

For reading journal data, refer to “EJ REPORT READING AND RESETTING” ( page 60 ).

EJ memory type

When this procedure is executed, EJ data is cleared, and PLU data (programming data and sales data) are reset to the default after all data is cleared even if the same memory type is selected.

@

*A

A s 90

*A: 0 for EJ 2000 lines and PLU 1200 codes (default)

1 for EJ 3000 lines and PLU 200 codes

Key operation example s 90 @

1 A

Print

45

46

Function parameters for EJ

s

To set “00000000”

68 @

*ABCDEFGH s A

* Item: Selection:

A

B

C

D

E

F

G

H

Always enter 0.

Always enter 0.

(Fixed position)

(Fixed position)

Temporary EJ printing during a transaction Disallow

Allow*

EJ printing and clearing EJ data when issuing general Z1 report

PGM mode operation records type

No*

Yes

Details*

Header information only

REG/MGR/VOID modes operation records type

Compressing printing for EJ data

Action when EJ memory area is full

Details*

Total

No (normal size)

Yes (small size)*

Continue

Warning (near full warning)*

Lock (with near full warning)

On the default setting, an asterisk is marked.

Entry:

0

1

2

0

1

0

1

0

1

0

1

0

1

0

0

Temporary EJ printing during a transaction

• If selecting “yes”, you can print journal data of a current transaction recorded in EJ memory by pressing the

R key during the transaction. To realize this function completely, the cash register is programmed to receipt printing and set Receipt ON/OFF function to OFF.

PGM mode operation records type

• The header information only is printed during the program reading operation.

The header information only is printed for X/Z reports.

(Receipt sample for Header Information only)

Action when EJ memory area is full

• By default, when the memory for EJ becomes nearly full, the cash register shows decimal points at the 8th and 9th positions of the display (EJ memory nearly full message), and the cash register keeps storing new data while erasing the oldest data. When “0” is selected, the cash register will no longer show EJ memory nearly full message. When “2” is selected, the cash register shows EJ memory nearly full message and when the memory is totally full, the cash register locks the sales/data entry with a display of the memory full message “ ”. You will only be able to issue an EJ report.

Print Key operation example s 68 @

00100002 s A

3

Various Function Selection Programming 1

The cash register provides various detailed functions listed below.

• Function selection for miscellaneous keys

• Print format

• Receipt print format

• Function selection for tax

• Others

For this programming, job code entry style is applied. You can continue programming until you press the

A key for the programming described in this section. To continue programming, repeat from a job code entry.

s

* 1 Job code

@

To set “00000000”

* 2 ABCDEFGH

*1 Enter job code using numeric keys specified in each section below.

*2 Data entry details are listed on each table in each section below.

Example: When programming for job code 5 as ABCDEFGH: 00000100.

Key operation example Print s 5 @

00000100 s A s A

Function selection for miscellaneous keys

Job code: 5

* Item:

A PO in REG mode

B

C

D

E

F

G

H

RA in REG mode

Subtotal void in REG mode

Indirect void in REG mode

Direct void in REG mode

Refund key availability

No sale in REG mode

Fractional quantity availability

Selection: Entry:

Allow the PO operation in REG mode*

Disallow it

Allow the RA operation in REG mode*

Disallow it

Allow the REG mode subtotal void*

Disallow it

Allow the REG mode indirect void*

Disallow it

Allow the REG mode direct void*

Disallow it

Allow the REG mode refund entry*

Disallow it 1

Allow the no sale operation in REG mode* 0

Disallow it

Allow fractional quantity entry

1

0

Disallow it*

1

0

1

0

1

1

0

1

0

0

1

0

47

48

Print format

Job code: 6

* Item:

A

B

C

D

E

F

G

H

Printing style

Selection:

Use the printer for journal printing

Receipt print format

Time print on all receipts/journals

Use the printer for receipt printing*

Total

Detailed*

Allow time printing*

Date print on all receipts/journals

Disallow it

Allow date printing*

Disallow it

Consecutive no. print on all receipts/journals Allow consecutive no. printing*

Always enter 0.

Zero skip for PLU report

Zero skip for general, clerk and hourly reports

Disallow it

(Fixed position)

Disallow zero skip

Allow zero skip*

Disallow zero skip

Allow zero skip*

Entry:

0

0

1

1

0

0

1

1

0

1

0

1

0

1

0

Printing style

• Even when receipt printing is selected, the journal rewind motor will be driven in PGM, OP X/Z, X1/Z1 and

X2/Z2 modes so you can wind sales and programming reports.

Receipt print format

Job code: 7

* Item:

A

B

C

D

E

F

G

H

Selection: Entry:

Always enter 0.

Always enter 0.

(Fixed position)

(Fixed position)

Subtotal print with a press of subtotal key Disallow subtotal printing*

Allow it

Merchandise print with a press of merchandise subtotal key

Always enter 0.

Always enter 0.

Always enter 0.

Number of purchases print

Disallow merchandise subtotal printing*

Allow it

(Fixed position)

(Fixed position)

(Fixed position)

Allow printing of number of purchases*

Disallow it

0

1

0

0

0

1

0

0

0

0

1

Function selection for tax

Job code: 15

* Item:

A to F Always enter 0.

G Tax delete in REG mode availability

H Manual tax entry in

REG mode availability

Selection:

(Fixed position)

Allow tax delete in REG mode*

Disallow it

Allow manual tax entry in REG mode*

Disallow it

Entry:

1

0

0

0

1

Other programming

Job code: 61

* Item: Selection: Entry:

A Always enter 0. (Fixed position) 0

B Always enter 0. (Fixed position) 0

C Minus dept. and PLU/subdept. availability Disallow to program minus dept. and PLU/subdept. 0

Allow it* 1

D Fractional treatment Round off (4 down, 5 up)* 0

Raising to unit 1

Disregarding fractional treatment 2

E Use of : key Use : key as 00 key* 0

Use :

key as 000 key 1

F Time format Use 12-hour format* 0

Use 24-hour format 1

G Date format Use month-day-year format* 0

Use day-month-year format 1

Use year-month-day format 2

H Position of decimal point (from right) (TAB) 0 to 3 (default 2)

Job code: 62

* Item: Selection: Entry:

A Always enter 0. (Fixed position) 0

B Error beep activation By lock error* 0

By misoperation 1

C Key touch sound availability Allow to sound* 0

Disallow it 1

D Buffered keyboard Yes* 0

No 1

E Void mode operation availability Allow void mode operation* 0

Disallow it 1

F Void mode entry data print in Z2 reports Allow printing of void mode entry data in Z2 reports* 0

Disallow it 1

G Void mode entry data print in Z1 reports Allow printing of void mode entry data in Z1 reports* 0

Disallow it 1

H Addition of hourly sales total data in No* 0 void mode Yes 1

Job code: 66

* Item: Selection: Entry:

A Printing a receipt after transaction Total only 0

Details* 1

B Amount printing when PLU/subdept. Disallow printing* 0 unit price is zero Allow it 1

C Subtotal printing for conversion of Allow printing* 0 deficit Disallow it 1

D Always enter 0. (Fixed position) 0

E Compression printing on journals in Disallow compression printing (normal size) 0

PGM, OP X/Z, X1/Z1 and X2/Z2 modes Allow compression printing (small size)* 1

F Compression printing on journals in Disallow compression printing (normal size) 0

REG, MGR and VOID modes Allow compression printing (small size)* 1

G Logo message printing on journals Disallow logo message printing on journals* 0

Allow logo message printing on journals 1

H Footer printing Printing footer on all receipts* 0

Printing footer with selected function key at the time of finalization 1

Compression printing

• This programming is valid only when journal printing is selected. This does not affect EJ printing. (For EJ

programming, please refer to page 46 .)

49

50

Job code: 70

* Item:

A

B

C

D

E

F

GH

Selection:

Split pricing counting Quantity*

Package

Multiplication/split pricing entry availability Allow multiplication entry only*

Allow both of multiplication and split pricing

Always enter 0.

Always enter 0.

Tax printing when GST is VAT

(Fixed position)

(Fixed position)

Allow tax printing*

Disallow it

GST exempt printing on X/Z reports

Tax calculation system

Allow printing of GST exempt*

Disallow it

Auto tax*

Canadian tax (tax type number)

Entry:

0

1

0

0

0

1

0

1

0

1

00

01 through 11

Tax calculation system

• For US tax system, select “auto-tax”.

• For Canadian tax, from the table below, specify a tax system suitable for your province (if necessary contact your local tax office for correct sales tax information) and for your type of retail business. In the cash register, four kinds of tax can be set and each tax is arranged to match GST or PST as follows:

Tax 1: PST Tax 2: PST

Tax 3: PST or GST Tax 4: GST

Canadian tax Tax 4 method type number GST

01 VAT

02 VAT

03

04

05

06

VAT

VAT

Add on Tax

Add on Tax

07

08

09

10

11

Add on Tax

Add on Tax

Add on Tax

Add on Tax

VAT

-

-

-

-

GST

VAT

VAT

-

VAT

VAT

Add on Tax

Add on Tax

Tax 3 method

PST

-

-

Tax on tax

Tax on base

Tax on tax

Tax on base

-

-

-

-

VAT (Tax on base)

Tax 2 and 1 method

PST

Tax on tax

Tax on base

Tax on tax

Tax on base

Tax on Tax

Tax on base

Tax on tax

Tax on base

Tax on tax

Tax on base

Tax on tax

(The most common type for Canada is type number 06.)

• To program a GST, use Tax 4; and to program two GSTs, use Tax 3 and 4. To program a PST, use Tax 1; to program two PSTs, use Tax 1 and 2; and to program three PSTs, use Tax 1, 2 and

3.

• The entry of a multi-taxable item for PST or GST is prohibited as follows for the Canadian tax system. When programming for departments, avoid programming the prohibited multi-taxable status.

In case of; Tax 1: PST, Tax 2: PST,

Tax 3: PST, Tax 4: GST

Taxable 1 and 2 item ········· prohibited

Taxable 1 and 3 item ········· prohibited

Taxable 2 and 3 item ········· prohibited

Taxable 1 and 4 item ············· allowed

Taxable 2 and 4 item ············· allowed

Taxable 3 and 4 item ············· allowed

In case of; Tax 1: PST, Tax 2: PST,

Tax 3: GST, Tax 4: GST

Taxable 1 and 2 item ········· prohibited

Taxable 1 and 3 item ············· allowed

Taxable 2 and 3 item ············· allowed

Taxable 1 and 4 item ············· allowed

Taxable 2 and 4 item ············· allowed

Taxable 3 and 4 item ········· prohibited

4

Various Function Selection Programming 2

The cash register provides various options so you can use the register to suit your sales needs.

In this section, you can program the following features (parameters within parentheses indicates default setting):

• Power save mode (entering the power save mode in 30 minutes)

• Logo message print format (graphic logo only)

• Thermal printer density (standard density)

• Online time out setting

• Language selection (English)

• Training clerk specification (none) - If you specify a clerk code who is trained for use on this cash register, the cash register will go into training mode when the clerk code is registered for sales entries. The sales operations done by the trained clerk does not affect sales total. For details, refer to TRAINING MODE section.

Power save mode

s 10 @

*ABCD s A

* Item:

A Entering power save mode when time is displayed

B-D Time(min.) to entering power save mode since no operation is made

Selection:

Yes*

No

Entry:

0

1

001-254 or 999

(Default 030)

When 999 is set for B to D, entering into power save mode is inhibited.

Print Key operation example s 10 @

0060 s A

Logo message print format

You can select the number of lines for your logo message, and the position to print it on receipt or journal.

To set “0” s 11 @

*A s A

*A: Logo message type

0: Header 3-line message without graphic logo

1: Graphic logo only (default)

2: Footer 3-line message with graphic logo

3: Header 6-line message

4: Header 3-line message with graphic logo

5: Header 3-line message and footer 3-line message

Key operation example s 11 @

0 s A

Print

51

52

Online time out setting

s 35 @

Time out (1 to 255 sec.)

Default: 007

Key operation example s 35 @

30 s A

Print s A

Thermal printer density

To set “0” s 50 @ * Printer density

(00-99) s A

* 50 is the default setting. To make the print darker, set a larger number, and to make the print lighter, set a smaller number.

Print Key operation example s 50 @

00 s A

advertisement

Related manuals

Download PDF

advertisement

Table of contents