![2 PLU (Price Look-Up) and Subdepartment Programming. Sharp XE-A20S | Manualzz 2 PLU (Price Look-Up) and Subdepartment Programming. Sharp XE-A20S | Manualzz](http://s3.manualzz.com/store/data/054544798_1-1ac43611255b1bfad7988d97255fc6b4-360x466.png)
Example: Programming department 2 as taxable 1, SICS, negative department, entry digit limit - 7 digits, and allowing open & preset entry. (ABCDEFGH: 00011173)
Key operation example Print
00011173 @
" A
From left, EGH
Tax status Sign(F)
Preset unit price
To program zero
Unit price
(max. six digits)
*
D
Dept. key
A
*To program departments 17 through 32, press the department shift key at this point.
For department 33-99:
Dept. code d
To program zero
Unit price
(max. six digits) s A
To program another department, start from the beginning without pressing the A key.
Print Key operation example
1000 !
A
Unit price
Even if a department is not programmed to allow the entry of preset unit prices in functional programming, the department is automatically changed to allow the entry of preset unit prices by this programming entry.
2
PLU (Price Look-Up) and Subdepartment Programming
The PLU function allows speedy key entries whereby a price is automatically called up when a code is entered.
The subdepartment is a kind of “open PLU”, which requires you to enter a price after the PLU code is entered. A maximum of 1200 PLU/subdepartment settings are possible. Each one belongs to a department and acquires the department’s parameters (tax status, SICS and sign).
The cash register is preprogrammed so all 1200 codes are assigned as PLUs associated with department 1 and preset unit price “0”.
33
34
Unit price and associated department assignment
*
2
PLU code p
To program zero
* 3
Unit price
(max. six digits)
* 1
D
Associated
Dept. key
A
*1: To assign departments 17 through 32, press the department shift key at this point.
When the associated department is department 33-99:
To program zero
* 2 PLU code p Associated dept. code
(1 to 99) d * 3 Unit price
(max. six digits) s A
*2: 1 through 1200 (Depending on the EJ memory size setting, up to 200)
*3: For a subdepartment, set the limit amount of unit price entry.
To program the following PLU, start from entering a unit price or an associated department code without pressing the A key.
To program another PLU, start from the beginning without pressing the A key.
Key operation example
1 p
125 #
A
Unit price
Associated dept.
PLU code
To delete a PLU code, use the following sequence:
PLU code p v
To delete the following PLU
A
To delete another PLU
PLU/subdepartment selection
* 1 PLU code p
To program "0"
* 2 A s
To program the following PLU
To program another PLU
*1: 1 through 1200 (Depending on the EJ memory size setting, up to 200)
*2: 0 for subdepartment or 1 for PLU (default: 1)
Print Key operation example
1 p
0 s A
A
PLU/subdept.
When you program the last PLU code, the programming sequence will be complete with a press of the s key.
advertisement
Related manuals
advertisement
Table of contents
- 3 INTRODUCTION
- 3 IMPORTANT
- 4 CONTENTS
- 6 PARTS AND THEIR FUNCTIONS
- 6 1 External View
- 6 2 Printer
- 7 3 Mode Switch and Mode Keys
- 7 4 Keyboard
- 8 5 Displays
- 8 6 Drawer Lock Key
- 9 GETTING STARTED
- 13 OVERVIEW OF FLOW OF DAILY SALES ENTRIES
- 14 BASIC SALES ENTRY
- 14 1 Basic Sales Entry Example
- 15 2 Error Warning
- 16 3 Item Entries
- 16 Single item entries
- 17 Repeat entries
- 17 Multiplication entries
- 18 Split pricing entries
- 19 Single item cash sale (SICS) entry
- 19 4 Displaying Subtotal
- 19 5 Finalization of Transaction
- 19 Cash or check tendering
- 20 Cash or check sale that does not require tender entry
- 20 Charge (credit) sale
- 20 Mixed-tender sale
- 21 6 Tax Calculation
- 21 Automatic tax
- 21 Manual tax
- 21 Tax delete
- 22 Tax status shift
- 23 OPTIONAL FEATURES
- 23 1 Auxiliary Entries
- 23 Discount and premium entries using the percent key
- 23 Discount and premium entries using the discount key
- 24 Refund entries
- 24 Non-add code number entries and printing
- 25 2 Auxiliary Payment Treatment
- 25 Currency conversion
- 26 Received-on Account and Paid-out Entries
- 26 No sale (exchange)
- 26 key) Entries
- 27 CORRECTION
- 27 1 Correction of the Last Entry (direct void)
- 27 2 Correction of the Next-to-last or Earlier Entry (indirect void)
- 28 3 Subtotal Void
- 28 4 Correction of Incorrect Entries not Handled by the Direct or Indirect Void Function
- 29 PRIOR TO PROGRAMMING
- 29 BASIC FUNCTION PROGRAMMING (For Quick Start)
- 29 1 Date and Time Programming
- 30 2 Tax Programming for Automatic Tax Calculation Function
- 30 Tax programming using a tax rate
- 31 The tax table (applicable to the add-on tax)
- 33 Quantity for doughnut tax exempt (for Canadian tax system)
- 34 AUXILIARY FUNCTION PROGRAMMING
- 34 1 Department Programming
- 35 2 PLU (Price Look-Up) and Subdepartment Programming
- 37 3 Miscellaneous Key Programming
- 40 (when using as CA key)
- 41 4 Text programming
- 46 ADVANCED PROGRAMMING
- 46 1 Register Number and Consecutive Number Programming
- 47 2 Electronic Journal (EJ) Programming
- 49 3 Various Function Selection Programming
- 49 Function selection for miscellaneous keys
- 50 Print format
- 50 Receipt print format
- 50 Function selection for tax
- 51 Other programming
- 53 4 Various Function Selection Programming
- 53 Power save mode
- 53 Logo message print format
- 54 Online time out setting
- 54 Thermal printer density