Crestron UC-C100-T Quick Start

Show HTML Add to My manuals
9 Pages

advertisement

Crestron UC-C100-T Quick Start | Manualzz

UC-C100-T

Crestron Flex Video Conference System Integrator Kit for Microsoft Teams® Rooms

The UC-C100-T Crestron Flex integrator kit provides a custom video conference solution for use with Microsoft Teams® Rooms software. It supports single or dual video displays and features a tabletop touch screen and a UC bracket assembly.

The latest firmware must be loaded onto the touch screen prior to operation. Refer to the touch screen's product page (resources tab) to download the latest device firmware. The latest UC-C100-T firmware is installed using the auto update feature.

Minimum Requirements: l l l l l

A certified USB Camera

A certified, AEC-enabled USB speakerphone or DSP device

A video display connected to the UC Engine. A second display is optional.

A Microsoft Teams or Skype® for Business account

An environment running Microsoft Exchange Server® software (2013

SP1 or later for on-premises installation or Microsoft 365® software for Cloud) for scheduling and/or Skype for Business 2015 (onpremises installation or Microsoft 365 software for Cloud)

1

1

1

2

2

2

4

2

1

1

1

1

1

Quick Start

UC Bracket Assembly

UC Bracket Assembly with UC Engine and HDMI® content ingest (6511478)

Anchor, Drywall, Plastic, 3/8 in. x 1/2 in. (2052565)

EDID passthrough (2055728)

Key, Anchor (4529654)

Power cord (2053985)

Screw, 8-AB x 1-1/2 in., Pan Head, Combo (2052567)

Tie Wrap (2047935)

Additional Items

PoE injector (6502429)

Cable, CAT6a, RJ-45 - RJ-45, 20 ft (6.1 m) (6507640)

Cable, CAT5e, RJ-45 - RJ-45, 7 ft (2.1 m) (6509924)

Cable, DisplayPort™ to HDMI, 6 ft (1.8 m) (6508282)

Cable, HDMI, 20 ft (6.1 m) (6503567)

Cable, HDMI, 6 ft (1.8 m) (6503565)

1

1

1

1

In the Box

Tabletop Touch Screen Device

10.1 in. Tabletop Touch Screen (6511748)

Grommet, Cable, Closed (2055455)

Grommet, Cable, Open (2055456)

Cover, Cable compartment (2055457)

Mount the UC Bracket Assembly

Mount the UC Bracket Assembly to VESA® compliant display devices, a wall, or other building structure. Anchors and screws are supplied for installation on walls 3/8 in. to 3/4 in. thickness.

CAUTION: The bracket assembly has preconnected cables and devices.

Only the direct connect adapter may be disconnected as noted in

Make

Connections . DO NOT DISCONNECT ANY OTHER DEVICES OR

CABLES THAT ARE ALREADY CONNECTED.

NOTE: The integrated cable tie wraps are reusable. Avoid damaging the cable tie wraps.

1

UC-C100-T

Crestron Flex Video Conference System Integrator Kit for Microsoft Teams® Rooms

Quick Start

Connect

System Overview

When connections are complete, the system appears as shown below. Refer to

Make Connections

for detailed connection instructions.

2

UC-C100-T Quick Start

Crestron Flex Video Conference System Integrator Kit for Microsoft Teams® Rooms

Make Connections

1. Make UC Engine connections as shown in the following illustrations. The touch screen can communicate with the UC Engine over a direct connection or a network connection. Select one of the connection types as described below.

a. Make a direct connection for simple installation and setup. Only use the direct connect adapter to connect the touch screen's PoE injector to the UC Engine. Do not use the direct connect adapter to connect the UC Engine to the network.

Direct Connection

3

UC-C100-T

Crestron Flex Video Conference System Integrator Kit for Microsoft Teams® Rooms b. Make a network connection if the system is to be managed by the XiO Cloud® service.

NOTE: When a network connection is used, disconnect the direct connect adapter from the UC Engine.

Network Connection

Quick Start

4

UC-C100-T

Crestron Flex Video Conference System Integrator Kit for Microsoft Teams® Rooms

Quick Start

2. Connect a USB audio source (not included) and displays to the UC Engine. Connect the EDID passthroughs to the displays.

5

UC-C100-T

Crestron Flex Video Conference System Integrator Kit for Microsoft Teams® Rooms

Quick Start

3. Remove the screw from the connector cover (located below the UC Engine) using a Philips #1 screwdriver (not included). Open the connector cover and retain the screw.

4. Connect a camera (not included) to the UC Engine as shown in the image below. Do not connect the camera to any of the other USB ports.

6

UC-C100-T

Crestron Flex Video Conference System Integrator Kit for Microsoft Teams® Rooms

5. Reattach the connector cover using the screw removed in step 3.

6. Connect a laptop to the content ingest device (HD-CONV-USB-200).

Quick Start

7. Bundle the cables to the bracket assembly with the integrated cable tie wraps. The cable tie wraps are reusable.

7

UC-C100-T

Crestron Flex Video Conference System Integrator Kit for Microsoft Teams® Rooms

2. Enter the following information in the appropriate fields: l

Teams Video PC Address: Enter the IP address or hostname of the

UC Engine.

Configure

Apply Power

Press the power button on the bottom of the UC Engine and apply power to all of the other devices in the system.

Configure the Touch Screen

NOTE:  If a direct connection was made during installation, skip to

Configure the System .

1. On a computer, open a web browser to the IP address of the touch screen. Log in and navigate to Settings > Applications.

NOTES: l

The touch screen (via the PoE injector) and computer must be on the same network switch and VLAN.

l

A login with administrative rights for the touch screen is required.

Quick Start

NOTE: The hostname is printed on a label affixed to the UC Engine

(mounted on the UC bracket assembly).

l l

Teams Video PC Port: By default, port number 49500 is used. If a different port number has been configured on the UC Engine, enter that port number instead.

Teams Video Username: Enter the login username for the UC

Engine. (The default username is “admin”.) l

Teams Video Password: Enter the login password for the UC

Engine. (The default password is “sfb”.)

3. Click Save Changes.

Configure the System

Use the touch screen and your Microsoft Teams or Skype account credentials to configure the UC Engine. For detailed information on deploying Microsoft Teams Rooms, refer to the Microsoft Teams Rooms documentation.

Visit the Product Page

Scan the QR code to visit the product page.

UC-C100-T www.crestron.com/model/6511589

8

UC-C100-T

Crestron Flex Video Conference System Integrator Kit for Microsoft Teams® Rooms

Quick Start

Additional Information

Original Instructions

The U.S. English version of this document is the original instructions.

All other languages are a translation of the original instructions.

Crestron product development software is licensed to Crestron dealers and Crestron

Service Providers (CSPs) under a limited nonexclusive, nontransferable Software

Development Tools License Agreement. Crestron product operating system software is licensed to Crestron dealers, CSPs, and end-users under a separate End-User License

Agreement. Both of these Agreements can be found on the Crestron website at www.crestron.com/legal/software_license_agreement .

The product warranty can be found at www.crestron.com/warranty .

The specific patents that cover Crestron products are listed at www.crestron.com/legal/patents .

Certain Crestron products contain open source software. For specific information, visit www.crestron.com/opensource .

Crestron, the Crestron logo, and XiO Cloud are either trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and/or other countries.

HDMI is either a trademark or registered trademark of HDMI Licensing LLC in the

United States and/or other countries. Microsoft 365, Microsoft Exchange Server,

Microsoft Teams, and Skype are either trademarks or registered trademarks of

Microsoft Corporation in the United States and/or other countries. DisplayPort and

VESA are either trademarks or registered trademarks of Video Electronics Standards

Association in the United States and/or other countries. Other trademarks, registered trademarks, and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims any proprietary interest in the marks and names of others. Crestron is not responsible for errors in typography or photography.

©2021 Crestron Electronics, Inc.

Doc. 8804C

03/18/21

9

advertisement

Related manuals

Download PDF

advertisement