Bruker manual


Add to my manuals
89 Pages

advertisement

Bruker manual | Manualzz

HP ProLiant BL465c Gen8 Server Blade

User Guide

Abstract

This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.

Part Number: 661814-001

June 2012

Edition: 1

© Copyright 2012 Hewlett-Packard Development Company, L.P.

The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.

Microsoft® and Windows® are U.S. registered trademarks of Microsoft Corporation.

Bluetooth® is a trademark owned by its proprietor and used by Hewlett-Packard Company under license.

Contents

Component identification ............................................................................................................... 6

Front panel components ............................................................................................................................. 6

Front panel LEDs and buttons ...................................................................................................................... 7

Drive LED definitions .................................................................................................................................. 8

System board components .......................................................................................................................... 8

System maintenance switch ............................................................................................................... 9

Mezzanine connector definitions ..................................................................................................... 10

DIMM slot locations ....................................................................................................................... 10

Tool location ........................................................................................................................................... 11

HP c-Class Blade SUV Cable..................................................................................................................... 11

Operations ................................................................................................................................. 12

Power up the server blade ........................................................................................................................ 12

Power down the server blade .................................................................................................................... 12

Remove the server blade .......................................................................................................................... 13

Remove the access panel.......................................................................................................................... 14

Install the access panel............................................................................................................................. 14

Remove the DIMM baffle .......................................................................................................................... 14

Install the DIMM baffle ............................................................................................................................. 15

Remove the front panel/drive cage assembly .............................................................................................. 16

Install the front panel/drive cage assembly ................................................................................................. 17

Remove the SAS controller ........................................................................................................................ 18

Install the SAS controller ........................................................................................................................... 19

Remove all drives .................................................................................................................................... 20

Setup ......................................................................................................................................... 22

Overview ............................................................................................................................................... 22

Installing an HP BladeSystem c-Class enclosure ........................................................................................... 22

Installing server blade options ................................................................................................................... 22

Installing interconnect modules .................................................................................................................. 22

Interconnect bay numbering and device mapping .............................................................................. 23

Connecting to the network ........................................................................................................................ 24

Installing a server blade ........................................................................................................................... 25

Completing the configuration .................................................................................................................... 26

Hardware options installation ....................................................................................................... 27

Introduction ............................................................................................................................................ 27

Drive option ........................................................................................................................................... 27

Processor option ...................................................................................................................................... 30

Memory options ...................................................................................................................................... 34

HP SmartMemory .......................................................................................................................... 35

Memory subsystem architecture ....................................................................................................... 36

Single-, dual-, and quad-rank DIMMs ............................................................................................... 36

DIMM identification ....................................................................................................................... 37

Memory configurations ................................................................................................................... 37

General DIMM slot population guidelines ......................................................................................... 38

Installing DIMMs ........................................................................................................................... 39

Contents 3

Mezzanine card option ............................................................................................................................ 40

Capacitor pack option ............................................................................................................................. 42

HP Trusted Platform Module option ............................................................................................................ 44

Installing the Trusted Platform Module board ..................................................................................... 45

Retaining the recovery key/password .............................................................................................. 46

Enabling the Trusted Platform Module ............................................................................................... 47

Cabling ..................................................................................................................................... 48

Cabling resources ................................................................................................................................... 48

Capacitor pack cabling ........................................................................................................................... 48

Drive cabling .......................................................................................................................................... 49

Using the HP c-Class Blade SUV Cable ...................................................................................................... 49

Connecting locally to a server blade with video and USB devices .................................................................. 49

Accessing a server blade with local KVM ......................................................................................... 49

Accessing local media devices ........................................................................................................ 50

Software and configuration utilities ............................................................................................... 52

Server mode ........................................................................................................................................... 52

Server QuickSpecs .................................................................................................................................. 52

HP iLO Management Engine ..................................................................................................................... 52

HP iLO ......................................................................................................................................... 52

Intelligent Provisioning .................................................................................................................... 54

HP Insight Remote Support software ................................................................................................. 56

Scripting Toolkit ............................................................................................................................ 56

HP Service Pack for ProLiant ..................................................................................................................... 57

HP Smart Update Manager ............................................................................................................. 57

HP ROM-Based Setup Utility ..................................................................................................................... 57

Using RBSU .................................................................................................................................. 58

Auto-configuration process .............................................................................................................. 58

Boot options ................................................................................................................................. 59

Configuring AMP modes ................................................................................................................ 59

Re-entering the server serial number and product ID ........................................................................... 59

Utilities and features ................................................................................................................................ 60

Array Configuration Utility .............................................................................................................. 60

Option ROM Configuration for Arrays ............................................................................................. 61

ROMPaq utility .............................................................................................................................. 61

Automatic Server Recovery ............................................................................................................. 61

USB support .................................................................................................................................. 62

Redundant ROM support ................................................................................................................ 62

Keeping the system current ....................................................................................................................... 62

Drivers ......................................................................................................................................... 62

Software and firmware ................................................................................................................... 63

Version control .............................................................................................................................. 63

HP Operating Systems and Virtualization Software Support for ProLiant Servers ..................................... 63

Change control and proactive notification ........................................................................................ 63

Troubleshooting .......................................................................................................................... 64

Troubleshooting resources ........................................................................................................................ 64

Battery replacement .................................................................................................................... 65

Regulatory compliance notices ..................................................................................................... 66

Regulatory compliance identification numbers ............................................................................................. 66

Federal Communications Commission notice ............................................................................................... 66

FCC rating label ............................................................................................................................ 66

Contents 4

FCC Notice, Class A Equipment ...................................................................................................... 66

FCC Notice, Class B Equipment ...................................................................................................... 66

Declaration of conformity for products marked with the FCC logo, United States only ....................................... 67

Modifications .......................................................................................................................................... 67

Cables ................................................................................................................................................... 67

Canadian notice (Avis Canadien) .............................................................................................................. 67

European Union regulatory notice ............................................................................................................. 68

Disposal of waste equipment by users in private households in the European Union ......................................... 68

Japanese notice ...................................................................................................................................... 69

BSMI notice ............................................................................................................................................ 69

Korean notice ......................................................................................................................................... 69

Chinese notice ........................................................................................................................................ 70

Vietnam compliance marking notice .......................................................................................................... 70

Ukraine notice ........................................................................................................................................ 70

Laser compliance .................................................................................................................................... 70

Battery replacement notice ........................................................................................................................ 71

Taiwan battery recycling notice ................................................................................................................. 71

Acoustics statement for Germany (Geräuschemission) .................................................................................. 71

Electrostatic discharge ................................................................................................................. 73

Preventing electrostatic discharge .............................................................................................................. 73

Grounding methods to prevent electrostatic discharge .................................................................................. 73

Specifications ............................................................................................................................. 74

Environmental specifications ..................................................................................................................... 74

Server blade specifications ....................................................................................................................... 74

Support and other resources ........................................................................................................ 75

Before you contact HP .............................................................................................................................. 75

HP contact information ............................................................................................................................. 75

Customer Self Repair ............................................................................................................................... 75

Acronyms and abbreviations ........................................................................................................ 83

Documentation feedback ............................................................................................................. 85

Index ......................................................................................................................................... 86

Contents 5

Component identification

Front panel components

Item Description

1

Serial label pull tab

2

HP c-Class Blade SUV connector* (behind the serial label pull tab)

3

Drive bay

4

Server blade release lever

5

Server blade release button

*The SUV connector and the HP c-Class Blade SUV Cable are used for some server blade configuration and diagnostic procedures.

Component identification 6

Front panel LEDs and buttons

Item Description

1

2

3

4

Health status LED bar

Power On/Standby button and System power LED

UID LED

FlexibleLOM LED

Status

Solid Green = Normal (System is powered on.)

Flashing Green = Power On/Standby Button service is being initialized.

Flashing Amber = Degraded condition

Flashing Red = Critical condition

Off = Normal (System is in standby.)

Solid Green = System is powered on.

Flashing Green = System is waiting to power on; Power On/Standby button is pressed.

Solid Amber = System is in standby; Power On/Standby Button service is initialized.

Off and the Health Status LED bar is off = The system has no power.

Off and the Health Status LED bar is flashing green = The Power On/Standby

Button service is being initialized.

Solid Blue = Identified

Flashing Blue = Active remote management

Off = No active remote management

Green = Network linked

Flashing Green = Network activity

Off = No link or activity

Component identification 7

Drive LED definitions

4

Drive status

Status Definition

Solid blue The drive is being identified by a host application.

Flashing blue The drive carrier firmware is being updated or requires an update.

Off

2

1

Item LED

Locate

Activity ring

3

Rotating green Drive activity

Off No drive activity

Do not remove Solid white Do not remove the drive. Removing the drive causes one or more of the logical drives to fail.

Removing the drive does not cause a logical drive to fail.

Solid green The drive is a member of one or more logical drives.

Flashing green The drive is rebuilding or performing a RAID migration, stripe size migration, capacity expansion, or logical drive extension, or is erasing.

Flashing amber/green

The drive is a member of one or more logical drives and predicts the drive will fail.

Flashing amber The drive is not configured and predicts the drive will fail.

Solid amber The drive has failed.

Off The drive is not configured by a RAID controller.

System board components

Component identification 8

Item Description

1

2

3

4

Processor 2 DIMM slots

Processor 1 DIMM slots

Internal USB connector

Pass-thru board

5

6

7

8

TPM connector

Mezzanine connector 1 (Type A mezzanine only)

MicroSD card slot

Mezzanine connector 2 (Type A or type B mezzanine)

9

10

11

12

Enclosure connector

System maintenance switch

FlexibleLOM connectors (2)

Drive power cable connector

13

14

15

16

Processor socket 1 (populated)

Processor socket 2

System battery

HP c-Class Blade SUV cable connector

The symbols correspond to the symbols located on the interconnect bays. For more information, see the

HP ProLiant BL465c Gen8 Server Blade Installation Instructions on the HP website ( http://www.hp.com/support ).

System maintenance switch

Position

S1

S2

S3

S4

S5

S6

S7

S8

S9

S10

S11

S12

Default

Off

Off

Off

Off

Off

Off

Function

Off = iLO security is enabled.

On = iLO security is disabled.

Off = System configuration can be changed.

On = System configuration is locked.

Reserved

Reserved

Off = Power-on password is enabled.

On = Power-on password is disabled.

Off = No function

On = ROM reads system configuration as invalid.

Reserved

Reserved

Reserved

Reserved

Reserved

Reserved

To access redundant ROM, set S1, S5, and S6 to on.

When the system maintenance switch position 6 is set to the On position, the system is prepared to erase all system configuration settings from both CMOS and NVRAM.

Component identification 9

CAUTION: Clearing CMOS and/or NVRAM deletes configuration information. Be sure to properly configure the server or data loss could occur.

Mezzanine connector definitions

A PCIe x8 mezzanine connector supports x16 cards at up to x8 speeds.

Item PCIe

Mezzanine connector 1

Mezzanine connector 2 x8, Type A mezzanine card only x16, Type A or B mezzanine card

DIMM slot locations

DIMM slots are numbered sequentially (1 through 8) for each processor. The supported AMP modes use the alpha assignments for population order, and the slot numbers designate the DIMM slot ID for spare replacement.

The arrow points to the front of the server blade.

Component identification 10

Tool location

A Torx T-15 Screwdriver is located on the DIMM baffle.

HP c-Class Blade SUV Cable

2

3

4

Item

1

Connector

Server blade

Video

USB

Serial

Description

For connecting to the SUV connector on the server blade front panel

For connecting a video monitor

For connecting up to two USB devices

For trained personnel to connect a null modem serial cable and perform advanced diagnostic procedures

Component identification 11

Operations

Power up the server blade

The Onboard Administrator initiates an automatic power-up sequence when the server blade is installed. If the default setting is changed, use one of the following methods to power up the server blade:

Use a virtual power button selection through iLO.

Press and release the Power On/Standby button.

When the server blade goes from the standby mode to the full power mode, the system power LED changes from amber to solid green. The health status LED bar flashes green when the Power On/Standby Button service is being initialized. For more information about the system power LED status, see "Front panel LEDs

(" Front panel LEDs and buttons " on page 7 )."

For more information about the Onboard Administrator, see the enclosure setup and installation guide on the

HP website ( http://www.hp.com/support/oa ).

For more information about iLO, see "HP iLO (on page 52 )."

Power down the server blade

Before powering down the server blade for any upgrade or maintenance procedures, perform a backup of critical server data and programs.

IMPORTANT: When the server blade is in standby mode, auxiliary power is still being provided to the system.

Depending on the Onboard Administrator configuration, use one of the following methods to power down the server blade:

Press and release the Power On/Standby button.

This method initiates a controlled shutdown of applications and the OS before the server blade enters standby mode.

Press and hold the Power On/Standby button for more than 4 seconds to force the server blade to enter standby mode.

This method forces the server blade to enter standby mode without properly exiting applications and the

OS. If an application stops responding, you can use this method to force a shutdown.

Use a virtual power button selection through iLO.

This method initiates a controlled remote shutdown of applications and the OS before the server blade enters standby mode.

Use the Onboard Administrator CLI to execute one of the following commands: o poweroff server [bay number]

This command initiates a controlled shutdown of applications and the OS before the server blade enters standby mode.

Operations 12

o poweroff server [bay number] force

This form of the command forces the server blade to enter standby mode without properly exiting applications and the OS. If an application stops responding, this method forces a shutdown.

Use the Onboard Administrator GUI to initiate a shutdown: a. b. c.

Select the Enclosure Information tab.

In the Device Bays item, select the Overall checkbox.

From the Virtual Power menu, initiate a shutdown of applications and the OS:

For a controlled shutdown, select Momentary Press.

For an emergency shutdown, select Press and Hold.

Before proceeding, verify the server blade is in standby mode by observing that the system power LED is amber.

Remove the server blade

To remove the component:

1.

Identify the proper server blade.

2.

3.

Power down the server blade (on page 12 ).

Remove the server blade.

4.

Place the server blade on a flat, level work surface.

WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them.

CAUTION: To prevent damage to electrical components, properly ground the server blade before beginning any installation procedure. Improper grounding can cause ESD.

Operations 13

Remove the access panel

To remove the component:

1.

Power down the server blade (on page 12 ).

2.

3.

4.

Remove the server blade (on page 13 ).

Press the access panel release button.

Slide the access panel towards the rear of the server blade, and then lift to remove the panel.

Install the access panel

1.

2.

Place the access panel on top of the server blade.

Slide the access panel forward until it clicks into place.

Remove the DIMM baffle

1.

2.

3.

Power down the server blade (on page 12 ).

Remove the server blade (on page 13 ).

Remove the access panel (on page 14 ).

CAUTION: Always disconnect the drive cables from the SAS controller before removing the

DIMM baffle. Failure to do so may result in damage to the SAS controller.

4.

Disconnect the drive cables from the SAS controller.

Operations 14

5.

Remove the DIMM baffle.

Install the DIMM baffle

1.

Install the DIMM baffle.

Operations 15

2.

Connect the drive cable connectors to the SAS controller.

3.

4.

Install the access panel (on page 14 ).

Install the server blade (" Installing a server blade " on page 25 ).

Remove the front panel/drive cage assembly

1.

2.

3.

Power down the server blade (on page 12 ).

Remove the server blade (on page 13 ).

Remove the access panel (on page 14 ).

CAUTION: Always disconnect the drive cables from the SAS controller before removing the

DIMM baffle. Failure to do so may result in damage to the SAS controller.

4.

5.

Remove the DIMM baffle (on page 14 ).

Extend the serial label pull tab from the front of the server blade.

Operations 16

6.

CAUTION: Always disconnect the drive cable before removing the front panel/drive cage assembly.

Remove the front panel/drive cage assembly.

Install the front panel/drive cage assembly

1.

2.

Extend the serial label pull tab from the front of the base pan.

Install the front panel/drive cage assembly and reconnect the drive cables.

Operations 17

3.

Close the serial label pull tab.

4.

5.

6.

Install the DIMM baffle (on page 15 ).

Install the access panel (on page 14 ).

Install the server blade (" Installing a server blade " on page 25 ).

Remove the SAS controller

1.

2.

3.

4.

Power down the server blade (on page 12 ).

Remove the server blade (on page 13 ).

Remove the access panel (on page 14 ).

Disconnect the capacitor pack cabling, if connected (" Capacitor pack cabling " on page 48 ).

CAUTION: Always disconnect the drive cables from the SAS controller before removing the

DIMM baffle. Failure to do so may result in damage to the SAS controller.

5.

6.

Disconnect the drive cables from the SAS controller (" Drive cabling " on page 49 ).

Remove the DIMM baffle (on page 14 ).

Operations 18

7.

Remove the SAS controller.

Install the SAS controller

1.

2.

Remove the DIMM baffle (on page 14 ).

Install the SAS controller. To properly seat the SAS controller, press firmly in the areas indicated on the

SAS controller.

3.

4.

5.

6.

Install the DIMM baffle (on page 15 ).

Connect the drive cables and the capacitor pack cables to the SAS controller. For more information, see

"Cabling (on page 48 )."

Install the access panel (on page 14 ).

Install the server blade (" Installing a server blade " on page 25 ).

Operations 19

Remove all drives

1.

Remove drive 1.

2.

Release the drive tray, slide it forward until it locks, and then press drive carrier 1 down to access drive

2.

Operations 20

3.

Remove drive 2.

4.

5.

Lift drive carrier 1 into position in the drive tray.

Slide the drive tray into the server blade. Close the drive tray lever until it locks into place.

Operations 21

Setup

Overview

Installation of a server blade requires the following steps:

1.

2.

Install and configure an HP BladeSystem c-Class enclosure.

Install any server blade options.

3.

4.

5.

6.

Install interconnect modules in the enclosure.

Connect the interconnect modules to the network.

Install a server blade.

Complete the server blade configuration.

Installing an HP BladeSystem c-Class enclosure

Before performing any server blade-specific procedures, install an HP BladeSystem c-Class enclosure.

The most current documentation for server blades and other HP BladeSystem components is available at the

HP website ( http://www.hp.com/go/bladesystem/documentation ).

Documentation is also available in the following locations:

Documentation CD that ships with the enclosure

HP website ( http://www.hp.com/go/bizsupport )

Installing server blade options

Before installing and initializing the server blade, install any server blade options, such as an additional processor, hard drive, or mezzanine card.

Installing interconnect modules

For specific steps to install interconnect modules, see the documentation that ships with the interconnect module.

Setup 22

Interconnect bay numbering and device mapping

HP BladeSystem c7000 Enclosure

To support network connections for specific signals, install an interconnect module in the bay corresponding to the FlexibleLOM or mezzanine signals.

Server blade signal Interconnect bay Interconnect bay labels

FlexibleLOM

1 and 2

Mezzanine 1

Mezzanine 2

3 and 4

5 and 6

7 and 8

For detailed port mapping information, see the HP BladeSystem enclosure installation poster or the

HP BladeSystem enclosure setup and installation guide on the HP website

( http://www.hp.com/go/bladesystem/documentation ).

Setup 23

HP BladeSystem c3000 Enclosure and Tower Enclosure

Interconnect bay label

Notes Server blade signal Interconnect bay number

FlexibleLOM

Mezzanine 1

Mezzanine 2

1

2

3 and 4

Four port cards connect to bay 2.

Four port cards

Ports 1 and 3 connect to bay 3.

Ports 2 and 4 connect to bay 4.

Connecting to the network

To connect the HP BladeSystem to a network, each enclosure must be configured with network interconnect devices to manage signals between the server blades and the external network.

Setup 24

Two types of interconnect modules are available for HP BladeSystem c-Class enclosures: Pass-Thru modules and switch modules. For more information about interconnect module options, see the HP website

( http://www.hp.com/go/bladesystem/interconnects ).

IMPORTANT: To connect to a network with a Pass-Thru module, always connect the Pass-Thru module to a network device that supports Gigabit or 10 Gb speed, depending on the corresponding Pass-Thru model.

Installing a server blade

CAUTION: To prevent improper cooling and thermal damage, do not operate the server blade enclosure unless all bays are populated with either a component or a blank.

For the best possible HP BladeSystem and Virtual Connect experience and to prevent a future reboot, HP requires updating the Onboard Administrator and Virtual Connect to the correct version before installing an

HP ProLiant Gen8 server blade. The version information is located on the tag on the front of the server blade.

For more information on this and other specific firmware and driver requirements as well as the latest firmware and driver versions, download the SPP on the HP website

( http://www.hp.com/go/spp/download ).

1.

Remove the device bay blank.

Setup 25

2.

Remove the enclosure connector cover.

3.

Install the server blade.

Completing the configuration

To complete the server blade and HP BladeSystem configuration, see the overview card that ships with the enclosure.

Setup 26

Hardware options installation

Introduction

If more than one option is being installed, read the installation instructions for all the hardware options and identify similar steps to streamline the installation process.

WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them.

CAUTION: To prevent damage to electrical components, properly ground the server before beginning any installation procedure. Improper grounding can cause electrostatic discharge.

Drive option

The server blade supports up to two SAS, SATA, or solid state drives. The mixing of SAS hard drives with SAS solid state drives is supported within the server, but limits the RAID configuration to two separate RAID 0 volumes. Mixing of other drives types is not supported.

CAUTION: To prevent improper cooling and thermal damage, do not operate the server blade or the enclosure unless all drive and device bays are populated with either a component or a blank.

To install the component:

1.

Remove the drive blank.

Hardware options installation 27

2.

Release the drive tray, slide it forward until it locks, and then press drive carrier 1 down to access drive bay 2.

3.

Prepare the drive.

Hardware options installation 28

4.

Install the drive in drive bay 2.

5.

Slide the drive tray into the server blade. Close the drive tray lever until it locks into place.

6.

Install the drive.

Hardware options installation 29

Processor option

WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them.

CAUTION: To avoid damage to the system board:

Do not touch the processor socket contacts.

Always install the processor socket cover after removing the processor from the socket.

• Do not tilt or slide the processor when lowering the processor into the socket.

CAUTION: To avoid damage to the processor:

• Handle the processor only by the edges.

• Do not touch the bottom of the processor, especially the contact area.

CAUTION: To prevent possible server blade malfunction and damage to the equipment, multiprocessor configurations must contain processors with the same part number.

CAUTION: The heatsink thermal interface media is not reusable and must be replaced if the heatsink is removed from the processor after it has been installed.

IMPORTANT: Processor socket 1 must be populated at all times or the server blade does not function.

To install a processor:

1.

2.

Locate and download the latest ROM version from the HP website ( http://www.hp.com/support ).

Follow the instructions on the website to update the system ROM.

Power down the server blade (on page 12 ).

3.

4.

5.

Remove the server blade (on page 13 ).

Remove all drives (on page 20 ).

Remove the access panel (on page 14 ).

CAUTION: Always disconnect the drive cables from the SAS controller before removing the

DIMM baffle. Failure to do so may result in damage to the SAS controller.

6.

7.

Remove the DIMM baffle (on page 14 ).

Remove the front panel/drive cage assembly (on page 16 ).

Hardware options installation 30

8.

Remove the heatsink blank. Retain the heatsink blank for future use.

9.

Open the processor socket locking lever and the retaining bracket, and then remove the processor socket protective cover.

IMPORTANT: Be sure the processor remains inside the processor installation tool.

Hardware options installation 31

10.

If the processor has separated from the installation tool, carefully re-insert the processor in the tool.

Handle the processor by the edges only, and do not touch the bottom of the processor, especially the contact area.

11.

The processor fits one way into the socket. Use the alignment guides on the processor and socket to properly align the processor with the socket. Install the spare processor. THE PINS ON THE SYSTEM

BOARD ARE VERY FRAGILE AND EASILY DAMAGED.

CAUTION: THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED. To avoid damage to the system board:

Never install or remove a processor without using the processor installation tool.

Do not touch the processor socket contacts.

• Do not tilt or slide the processor when lowering the processor into the socket.

Hardware options installation 32

12.

Press the tabs on the processor tool to release the processor, and then remove the processor tool.

13.

Close the processor socket retaining bracket and the processor locking lever.

CAUTION: Be sure to close the processor socket retaining bracket before closing the processor locking lever. The lever should close without resistance. Forcing the lever closed can damage the processor and socket, requiring system board replacement.

Hardware options installation 33

14.

Remove the thermal interface protective cover from the heatsink.

CAUTION: To avoid damage to the system board, processor socket, and screws, do not overtighten the heatsink screws. Use the wrench supplied with the system to reduce the possibility of overtightening the screws.

15.

Align and install the heatsink. Alternate tightening the screws until the heatsink is seated properly.

16.

17.

18.

19.

20.

Install the front panel/drive cage assembly.

Install the DIMM baffle (on page 15 ).

Install the access panel (on page 14 ).

Install the drives (" Drive option " on page 27 ).

Install the server blade (" Installing a server blade " on page 25 ).

Memory options

Hardware options installation 34

IMPORTANT: This server blade does not support mixing LRDIMMs or RDIMMs. Attempting to mix any combination of these DIMMs can cause the server to halt during BIOS initialization.

The memory subsystem in this server blade can support LRDIMMs or RDIMMs:

RDIMMs offer lower latency in one DIMM per channel configurations and (relatively) low power consumption. They include address parity protection.

LRDIMMs support higher densities than single- and dual-rank RDIMMs, and higher speeds than quad-rank RDIMMs. This support enables you to install more high capacity DIMMs, resulting in higher system capacities and higher bandwidth.

All types are referred to as DIMMs when the information applies to all types. When specified as LRDIMM or

RDIMM, the information applies to that type only. All memory installed in the server blade must be the same type.

The server supports the following DIMM speeds:

Single- and dual-rank PC3-10600 (DDR-1333) RDIMMs operating at up to 1333 MT/s

Single- and dual-rank PC3-12800 (DDR-1600) RDIMMs operating at up to 1600 MT/s

Quad-rank PC3L-10600 (DDR3-1333) LRDIMMs, operating as dual-rank DIMMs, at up to 1333 MT/s

Speed, voltage, and capacity

DIMM type DIMM rank

RDIMM

RDIMM

RDIMM

RDIMM

RDIMM

RDIMM

LRDIMM

Single-rank

Single-rank

Dual-rank

Single-rank

Dual-rank

Dual-rank

Quad-rank

DIMM capacity

4 GB

4 GB

8 GB

8 GB

16 GB

16 GB

32 GB

Native speed (MT/s)

1333

1600

1333

1600

1333

1600

1333

Voltage

LV

STD

LV

STD

LV

STD

LV

Memory operating data rate is dependent on processor capability, DIMM capability, operating voltage, and the number of DIMMs installed in a channel.

Populated DIMM speed (MT/s)

DIMM type DIMM rank

RDIMM (LV)

RDIMM (STD)

RDIMM (LV)

RDIMM (STD)

RDIMM (LV)

RDIMM (STD)

LRDIMM (LV)

Single-rank (4 GB)

Single-rank (4 GB)

Dual-rank (8 GB)

Single-rank (8 GB)

Dual-rank (16 GB)

Dual-rank (16 GB)

Quad-rank (32 GB)

1 DIMM per channel

1333

1600

1333

1600

1333

1600

1333

2 DIMMs per channel

1333

1600

1333

1600

1333

1600

1333

HP SmartMemory

HP SmartMemory, introduced for Gen8 servers, authenticates and unlocks certain features available only on

HP Qualified memory and verifies whether installed memory has passed HP qualification and test processes.

Hardware options installation 35

Qualified memory is performance-tuned for HP ProLiant and BladeSystem servers and provides future enhanced support through HP Active Health and manageability software.

Memory subsystem architecture

The memory subsystem in this server blade is divided into channels. Each processor supports four channels, and each channel supports two DIMM slots, as shown in the following table.

Channel Slot Slot number

1

2

3

4

B

F

D

H

A

E

C

G

5

6

7

8

1

2

3

4

For the location of the slot numbers, see "DIMM slot locations (on page 10 )."

This multi-channel architecture provides enhanced performance in Advanced ECC mode.

DIMM slots in this server are identified by number and by letter. Letters identify the population order. Slot numbers indicate the DIMM slot ID for spare replacement.

Single-, dual-, and quad-rank DIMMs

To understand and configure memory protection modes properly, an understanding of single-, dual-, and quad-rank DIMMs is helpful. Some DIMM configuration requirements are based on these classifications.

A single-rank DIMM has one set of memory chips that is accessed while writing to or reading from the memory. A dual-rank DIMM is similar to having two single-rank DIMMs on the same module, with only one rank accessible at a time. A quad-rank DIMM is, effectively, two dual-rank DIMMs on the same module. Only one rank is accessible at a time. The server blade memory control subsystem selects the proper rank within the DIMM when writing to or reading from the DIMM.

Dual- and quad-rank DIMMs provide the greatest capacity with the existing memory technology. For example, if current DRAM technology supports 8-GB single-rank DIMMs, a dual-rank DIMM would be 16

GB, and a quad-rank DIMM would be 32 GB.

LRDIMMs are labeled as quad-rank DIMMs; however, they function more like dual-rank DIMMs. There are four ranks of DRAM on the DIMM, but the LRDIMM buffer creates an abstraction that allows the DIMM to appear as a dual-rank DIMM to the system. The LRDIMM buffer also isolates the electrical loading of the

DRAM from the system to allow for faster operation. These two changes allow the system to support up to three LRDIMMs per memory channel, providing for up to 50% greater memory capacity and higher memory operating speed compared to quad-rank RDIMMs.

Hardware options installation 36

DIMM identification

To determine DIMM characteristics, use the label attached to the DIMM and the following illustration and table.

Item Description

1

2

3

4

5

6

Size

Rank

Data width

Voltage rating

Memory speed

DIMM type

Definition

1R = Single-rank

2R = Dual-rank

4R = Quad-rank x4 = 4-bit x8 = 8-bit

L = Low voltage (1.35v)

U = Ultra low voltage (1.25v)

Blank or omitted = Standard

12800 = 1600-MT/s

10600 = 1333-MT/s

8500 = 1066-MT/s

R = RDIMM (registered)

E = UDIMM (unbuffered with ECC)

L = LRDIMM (load reduced)

For the latest supported memory information, see the QuickSpecs on the HP website

( http://h18000.www1.hp.com/products/quickspecs/ProductBulletin.html

). At the website, choose the geographic region, and then locate the product by name or product category.

Memory configurations

To optimize server blade availability, the server blade supports the following AMP modes:

Advanced ECC—provides up to 4-bit error correction and is the default option for this server blade.

Online spare memory—provides protection against failing or degraded DIMMs. Certain memory is reserved as spare, and automatic failover to spare memory occurs when the system detects a DIMM that

Hardware options installation 37

is degrading. This allows DIMMs that have a higher probability of receiving an uncorrectable memory error (which would result in system downtime) to be removed from operation.

Advanced Memory Protection options are configured in RBSU. If the requested AMP mode is not supported by the installed DIMM configuration, the server blade boots in Advanced ECC mode. For more information,

see "HP ROM-Based Setup Utility (on page 57 )."

Maximum capacity

DIMM type

RDIMM

RDIMM

LRDIMM

DIMM rank

Single-rank

Dual-rank

Quad-rank

One processor

64 GB

128 GB

256 GB

Two processors

128 GB

256 GB

512 GB

For the latest memory configuration information, see the QuickSpecs on the HP website

( http://www.hp.com

).

Advanced ECC memory configuration

Advanced ECC memory is the default memory protection mode for this server blade. Standard ECC can correct single-bit memory errors and detect multi-bit memory errors. When multi-bit errors are detected using

Standard ECC, the error is signaled to the server blade and causes the server blade to halt.

Advanced ECC protects the server blade against some multi-bit memory errors. Advanced ECC can correct both single-bit memory errors and 4-bit memory errors if all failed bits are on the same DRAM device on the

DIMM.

Advanced ECC provides additional protection over Standard ECC because it is possible to correct certain memory errors that would otherwise be uncorrected and result in a server blade failure. Using HP Advanced

Memory Error Detection technology, the server blade provides notification when a DIMM is degrading and has a higher probability of uncorrectable memory error.

Online Spare memory configuration

Online spare memory provides protection against degraded DIMMs by reducing the likelihood of uncorrected memory errors. This protection is available without any operating system support.

Online spare memory protection dedicates one rank of each memory channel for use as spare memory. The remaining ranks are available for OS and application use. If correctable memory errors occur at a rate higher than a specific threshold on any of the non-spare ranks, the server blade automatically copies the memory contents of the degraded rank to the online spare rank. The server blade then deactivates the failing rank and automatically switches over to the online spare rank.

General DIMM slot population guidelines

Observe the following guidelines for all AMP modes:

Install DIMMs only if the corresponding processor is installed.

When two processors are installed, balance the DIMMs across the two processors.

White DIMM slots denote the first slot of a channel (Ch 1-A, Ch 2-C, Ch 3-B, Ch 4-D).

Do not mix RDIMMs or LRDIMMs.

Hardware options installation 38

When one processor is installed, install DIMMs in sequential alphabetic order: A, B, C, D, E, F, and so forth.

When two processors are installed, install the DIMMs in sequential alphabetic order balanced between the two processors: P1-A, P2-A, P1-B, P2-B, P1-C, P2-C, and so forth.

For DIMM spare replacement, install the DIMMs per slot number as instructed by the system software.

For detailed memory configuration rules and guidelines, use the Online DDR3 Memory Configuration Tool on the HP website ( http://www.hp.com/go/ddr3memory-configurator ).

1

1

2

DIMM speeds are supported as indicated in the following table.

Populated slots

(per channel)

Rank Speeds supported

(MT/s)

Single or dual

Quad

Single or dual

1333, 1066

1066

1066

Advanced ECC population guidelines

For Advanced ECC mode configurations, observe the following guidelines:

Observe the general DIMM slot population guidelines (on page 38 ).

DIMMs may be installed individually.

Online spare population

For online spare memory mode configurations, observe the following guidelines:

Observe the general DIMM slot population guidelines (on page 38 ).

Each channel must have a valid online spare configuration.

Each channel can have a different valid online spare configuration.

Each populated channel must have a spare rank: o

A single dual-rank DIMM is not a valid configuration. o

LRDIMMs are treated as dual-rank DIMMs.

Population order

For memory configurations with a single processor or multiple processors, populate the DIMM slots in the following order:

LRDIMM: Sequentially in alphabetical order (A through H)

RDIMM: Sequentially in alphabetical order (A through H)

After installing the DIMMs, use RBSU to configure Advanced ECC or online spare memory support.

Installing DIMMs

To install the component:

1.

Power down the server blade (on page 12 ).

Hardware options installation 39

2.

3.

4.

5.

6.

Remove the server blade (on page 13 ).

Remove the access panel (on page 14 ).

Remove the DIMM baffle (on page 14 ).

Open the DIMM slot latches.

Install the DIMM.

7.

8.

9.

10.

Install all DIMM baffles (" Install the DIMM baffle " on page 15 ).

Install the access panel (on page 14 ).

Install the server blade (" Installing a server blade " on page 25 ).

Power up the server blade (on page 12 ).

Mezzanine card option

Optional mezzanine cards are classified as Type A mezzanine cards and Type B mezzanine cards. The type of the mezzanine card determines where it can be installed in the server blade.

Install Type A mezzanine cards on Mezzanine 1 connector or Mezzanine 2 connector.

Install Type B mezzanine cards on Mezzanine 2 connector.

Optional mezzanine cards enable network connectivity or provide Fibre Channel support. For mezzanine

card locations, see the system board components (on page 8 ).

When installing a mezzanine option on mezzanine connector 2, processor 2 must be installed.

For mezzanine card mapping, see the HP ProLiant BL465c Gen8 Server Blade Installation Instructions or see

"Interconnect bay numbering and device mapping (on page 23 )."

To install the component:

1.

Power down the server blade (on page 12 ).

2.

3.

Remove the server blade (on page 13 ).

Remove the access panel.

Hardware options installation 40

4.

Remove the mezzanine assembly from the server blade.

5.

Align the mezzanine card with the guide pins on the mezzanine assembly.

Hardware options installation 41

6.

Install the mezzanine card in the mezzanine assembly, and then tighten the mezzanine card screws to secure the card to the mezzanine assembly.

7.

8.

Align the mezzanine assembly with the guide pins on the system board, and then install the mezzanine assembly on the system board.

Press down firmly on the mezzanine assembly handles, and then close the mezzanine assembly latch.

9.

10.

Install the access panel (on page 14 ).

Install the server blade (" Installing a server blade " on page 25 ).

Capacitor pack option

To install the component:

1.

2.

Power down the server blade (on page 12 ).

Remove the server blade (on page 13 ).

Hardware options installation 42

3.

4.

5.

Remove the access panel (on page 14 ).

Remove the DIMM baffle (on page 14 ).

Install the FBWC capacitor pack: o

FBWC capacitor pack for a mezzanine option o

FBWC capacitor pack for the SAS controller

6.

Route the FBWC capacitor pack cable. The DIMM baffles may be removed to route the cables, if necessary.

Hardware options installation 43

o

Route the cable between the DIMMs and the heatsinks or heatsink blank. Connect the cable to the mezzanine option. o

Route the cable along the DIMM baffle and connect the cable to the SAS controller.

7.

8.

9.

Install the DIMM baffle (on page 15 ).

Install the access panel (on page 14 ).

Install the server blade (" Installing a server blade " on page 25 ).

HP Trusted Platform Module option

Use these instructions to install and enable a TPM on a supported server blade. This procedure includes three sections:

1.

Installing the Trusted Platform Module board (on page 45 ).

2.

Retaining the recovery key/password (on page 46 ).

3.

Enabling the Trusted Platform Module (on page 47 ).

Enabling the TPM requires accessing RBSU (" HP ROM-Based Setup Utility " on page 57 ). For more

information about RBSU, see the HP website ( http://www.hp.com/go/ilomgmtengine/docs ).

TPM installation requires the use of drive encryption technology, such as the Microsoft Windows BitLocker

Drive Encryption feature. For more information on BitLocker, see the Microsoft website

( http://www.microsoft.com

).

Hardware options installation 44

CAUTION: Always observe the guidelines in this document. Failure to follow these guidelines can cause hardware damage or halt data access.

When installing or replacing a TPM, observe the following guidelines:

Do not remove an installed TPM. Once installed, the TPM becomes a permanent part of the system board.

When installing or replacing hardware, HP service providers cannot enable the TPM or the encryption technology. For security reasons, only the customer can enable these features.

When returning a system board for service replacement, do not remove the TPM from the system board.

When requested, HP Service provides a TPM with the spare system board.

Any attempt to remove an installed TPM from the system board breaks or disfigures the TPM security rivet. Upon locating a broken or disfigured rivet on an installed TPM, administrators should consider the system compromised and take appropriate measures to ensure the integrity of the system data.

When using BitLocker, always retain the recovery key/password. The recovery key/password is required to enter Recovery Mode after BitLocker detects a possible compromise of system integrity.

HP is not liable for blocked data access caused by improper TPM use. For operating instructions, see the encryption technology feature documentation provided by the operating system.

Installing the Trusted Platform Module board

WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them.

1.

2.

3.

4.

5.

6.

Power down the server blade (on page 12 ).

Remove the server blade (on page 13 ).

Place the server blade on a flat, level work surface.

Remove the access panel (on page 14 ).

Remove the mezzanine assembly (" Mezzanine card option " on page 40 ).

Locate the TPM connector (" System board components " on page 8 ).

CAUTION: Any attempt to remove an installed TPM from the system board breaks or disfigures the TPM security rivet. Upon locating a broken or disfigured rivet on an installed TPM, administrators should consider the system compromised and take appropriate measures to ensure the integrity of the system data.

Hardware options installation 45

7.

Install the TPM board. Press down on the connector to seat the board (" System board components " on page 8 ).

8.

Install the TPM security rivet by pressing the rivet firmly into the system board.

9.

10.

11.

Install the mezzanine assembly.

Install the access panel (on page 14 ).

Install the server blade (" Installing a server blade " on page 25 ).

Retaining the recovery key/password

The recovery key/password is generated during BitLocker™ setup, and can be saved and printed after

BitLocker™ is enabled. When using BitLocker™, always retain the recovery key/password. The recovery key/password is required to enter Recovery Mode after BitLocker™ detects a possible compromise of system integrity.

To help ensure maximum security, observe the following guidelines when retaining the recovery key/password:

Always store the recovery key/password in multiple locations.

Hardware options installation 46

Always store copies of the recovery key/password away from the server blade.

Do not save the recovery key/password on the encrypted hard drive.

Enabling the Trusted Platform Module

1.

When prompted during the start-up sequence, access RBSU by pressing the F9 key.

2.

3.

4.

5.

6.

7.

8.

From the Main Menu, select Server Security.

From the Server Security Menu, select Trusted Platform Module.

From the Trusted Platform Module Menu, select TPM Functionality.

Select Enable, and then press the Enter key to modify the TPM Functionality setting.

Press the Esc key to exit the current menu, or press the F10 key to exit RBSU.

Reboot the server blade.

Enable the TPM in the OS. For OS-specific instructions, see the OS documentation.

CAUTION: When a TPM is installed and enabled on the server blade, data access is locked if you fail to follow the proper procedures for updating the system or option firmware, replacing the system board, replacing a hard drive, or modifying OS application TPM settings.

For more information on firmware updates and hardware procedures, see the HP Trusted Platform Module

Best Practices White Paper on the HP website ( http://www.hp.com/support ).

For more information on adjusting TPM usage in BitLocker™, see the Microsoft website

( http://technet.microsoft.com/en-us/library/cc732774.aspx

).

Hardware options installation 47

Cabling

Cabling resources

Cabling configurations and requirements vary depending on the product and installed options. For more information about product features, specifications, options, configurations, and compatibility, see the

QuickSpecs on the HP website ( http://h18000.www1.hp.com/products/quickspecs/ProductBulletin.html

).

At the website, choose the geographic region, and then locate the product by name or product category.

Capacitor pack cabling

FBWC capacitor pack cabling for the SAS controller

FBWC capacitor pack cabling for the mezzanine option

For capacitor pack and cabling instructions, see "Capacitor pack option (on page 42 )."

Cabling 48

Drive cabling

Using the HP c-Class Blade SUV Cable

The HP c-Class Blade SUV Cable enables the user to perform server blade administration, configuration, and diagnostic procedures by connecting video and USB devices directly to the server blade. For SUV cable

connectors, see "HP c-Class Blade SUV Cable (on page 11 )."

Connecting locally to a server blade with video and

USB devices

Use the SUV cable to connect a monitor and any of the following USB devices:

USB hub

USB keyboard

USB mouse

USB CD/DVD-ROM drive

Numerous configurations are possible. This section offers two possible configurations. For more information,

see "USB support (on page 62 )."

Accessing a server blade with local KVM

For this configuration, a USB hub is not necessary. To connect additional devices, use a USB hub.

CAUTION: Before disconnecting the SUV cable from the connector, always squeeze the release buttons on the sides of the connector. Failure to do so can result in damage to the equipment.

1.

2.

Open the serial label pull tab and connect the HP c-Class Blade SUV Cable to the server blade.

Connect the video connector to a monitor.

Cabling 49

3.

4.

Connect a USB mouse to one USB connector.

Connect a USB keyboard to the second USB connector.

Description

Monitor

USB mouse

USB keyboard

HP c-Class Blade SUV Cable

Item

3

4

1

2

Accessing local media devices

Use the following configuration when configuring a server blade or loading software updates and patches from a USB CD/DVD-ROM.

Use a USB hub when connecting a USB CD-ROM drive to the server blade. The USB hub provides additional connections.

1.

Open the serial label pull tab and connect the HP c-Class Blade SUV cable to the server blade.

2.

3.

Connect the video connector to a monitor.

Connect a USB hub to one USB connector.

4.

Connect the following to the USB hub: o

USB CD/DVD-ROM drive o

USB keyboard

Cabling 50

o

USB mouse

Item

3

4

5

6

1

2

Description

Monitor

USB CD/DVD-ROM drive

USB keyboard

USB hub

USB mouse

HP c-Class Blade SUV Cable

Cabling 51

Software and configuration utilities

Server mode

The software and configuration utilities presented in this section operate in online mode, offline mode, or in both modes.

Software or configuration utility Server mode

HP iLO (on page 52 )

Online and Offline

Active Health System (on page 53 )

Integrated Management Log (on page 54 )

Intelligent Provisioning (on page 54 )

HP Insight Diagnostics (on page 55 )

HP Insight Remote Support software (on page 56 )

Erase Utility (on page 55 )

Scripting Toolkit (on page 56 )

HP Service Pack for ProLiant (on page 57 )

HP Smart Update Manager (on page 57 )

HP ROM-Based Setup Utility (on page 57 )

Array Configuration Utility (on page 60 )

Option ROM Configuration for Arrays (on page 61 )

ROMPaq utility (on page 61 )

Online and Offline

Online and Offline

Offline

Online and Offline

Online

Offline

Online

Online and Offline

Online and Offline

Offline

Online and Offline

Offline

Offline

Server QuickSpecs

For more information about product features, specifications, options, configurations, and compatibility, see the QuickSpecs on the HP website

( http://h18000.www1.hp.com/products/quickspecs/ProductBulletin.html

). At the website, choose the geographic region, and then locate the product by name or product category.

HP iLO Management Engine

The HP iLO Management Engine is a set of embedded management features supporting the complete lifecycle of the server blade, from initial deployment through ongoing management.

HP iLO

The iLO subsystem is a standard component of selected HP ProLiant servers that simplifies initial server blade setup, server health monitoring, power and thermal optimization, and remote server administration. The iLO subsystem includes an intelligent microprocessor, secure memory, and a dedicated network interface. This design makes iLO independent of the host server and its operating system.

Software and configuration utilities 52

iLO enables and manages the Active Health System (on page 53 ) and also features Agentless Management.

All key internal subsystems are monitored by iLO. SNMP alerts are sent directly by iLO regardless of the host operating system or even if no host operating system is installed.

HP Insight Remote Support software (on page 56 ) is also available in HP iLO with no operating system

software, drivers, or agents.

Using iLO, you can do the following:

Access a high-performance and secure Remote Console to the server from anywhere in the world.

Use the shared iLO Remote Console to collaborate with up to six server administrators.

Remotely mount high-performance Virtual Media devices to the server blade.

Securely and remotely control the power state of the managed server blade.

Have true Agentless Management with SNMP alerts from iLO regardless of the state of the host server blade.

Access Active Health System troubleshooting features through the iLO interface.

Subscribe to HP Insight Remote Support software without installing any drivers or agents.

For more information about iLO features (which may require an iLO Advanced Pack or iLO Advanced for

BladeSystem license), see the iLO documentation on the Documentation CD or on the HP website

( http://www.hp.com/go/ilo/docs ).

Active Health System

HP Active Health System provides the following features:

Combined diagnostics tools/scanners

Always on, continuous monitoring for increased stability and shorter downtimes

Rich configuration history

Health and service alerts

Easy export and upload to Service and Support

The HP Active Health System monitors and records changes in the server hardware and system configuration.

The Active Health System assists in diagnosing problems and delivering rapid resolution when server failures occur.

The Active Health System collects the following types of data:

Server model

Serial number

Processor model and speed

Storage capacity and speed

Memory capacity and speed

Firmware/BIOS

HP Active Health System does not collect information about Active Health System users' operations, finances, customers, employees, partners, or data center, such as IP addresses, host names, user names, and passwords. HP Active Health System does not parse or change operating system data from third-party error event log activities, such as content created or passed through by the operating system.

Software and configuration utilities 53

The data that is collected is managed according to the HP Data Privacy policy. For more information see the

HP website ( http://www.hp.com/go/privacy ).

The Active Health System log, in conjunction with the system monitoring provided by Agentless Management or SNMP Pass-thru, provides continuous monitoring of hardware and configuration changes, system status, and service alerts for various server components.

The Agentless Management Service is available in the SPP, which is a disk image (.iso) that you can download from the HP website ( http://www.hp.com/go/spp/download ). The Active Health System log can be downloaded manually from iLO or HP Intelligent Provisioning and sent to HP. For more information, see the HP iLO User Guide or HP Intelligent Provisioning User Guide on the HP website

( http://www.hp.com/go/ilo/docs ).

Integrated Management Log

The IML records hundreds of events and stores them in an easy-to-view form. The IML timestamps each event with 1-minute granularity.

You can view recorded events in the IML in several ways, including the following:

From within HP SIM

From within operating system-specific IML viewers o o

For Windows: IML Viewer

For Linux: IML Viewer Application

From within the iLO user interface

From within HP Insight Diagnostics (on page 55 )

Intelligent Provisioning

Several packaging changes have taken place with HP ProLiant Gen8 servers: SmartStart CDs and the Smart

Update Firmware DVD will no longer ship with these new server blades. Instead, the deployment capability is embedded in the server blade as part of HP iLO Management Engine’s Intelligent Provisioning.

Intelligent Provisioning is an essential single-server deployment tool embedded in HP ProLiant Gen8 servers that simplifies HP ProLiant server setup, providing a reliable and consistent way to deploy HP ProLiant server configurations.

Intelligent Provisioning assists with the OS installation process by preparing the system for installing

"off-the-shelf" versions of leading operating system software and automatically integrating optimized

HP ProLiant server support software from SPP. SPP is the installation package for operating system-specific bundles of HP ProLiant optimized drivers, utilities, management agents, and system firmware.

Intelligent Provisioning provides maintenance-related tasks through Perform Maintenance features.

Intelligent Provisioning provides installation help for Microsoft Windows, Red Hat and SUSE Linux, and

VMware. For specific OS support, see the HP Intelligent Provisioning Release Notes.

For more information on Intelligent Provisioning software, see the HP website ( http://www.hp.com/go/ilo ).

For more information about Intelligent Provisioning drivers, firmware, and SPP, see the HP website

( http://www.hp.com/go/spp/download ).

Software and configuration utilities 54

HP Insight Diagnostics

HP Insight Diagnostics is a proactive server blade management tool, available in both offline and online versions, that provides diagnostics and troubleshooting capabilities to assist IT administrators who verify server blade installations, troubleshoot problems, and perform repair validation.

HP Insight Diagnostics Offline Edition performs various in-depth system and component testing while the OS

is not running. To run this utility, boot the server blade using Intelligent Provisioning (on page 54 ).

HP Insight Diagnostics Online Edition is a web-based application that captures system configuration and other related data needed for effective server blade management. Available in Microsoft Windows and

Linux versions, the utility helps to ensure proper system operation.

For more information or to download the utility, see the HP website ( http://www.hp.com/servers/diags ). HP

Insight Diagnostics Online Edition is also available in the SPP. For more information, see the HP website

( http://www.hp.com/go/spp/download ).

HP Insight Diagnostics survey functionality

HP Insight Diagnostics (on page 55 ) provides survey functionality that gathers critical hardware and software

information on ProLiant server blades.

This functionality supports operating systems that are supported by the server blade. For operating systems supported by the server blade, see the HP website ( http://www.hp.com/go/supportos ).

If a significant change occurs between data-gathering intervals, the survey function marks the previous information and overwrites the survey data files to reflect the latest changes in the configuration.

Survey functionality is installed with every Intelligent Provisioning-assisted HP Insight Diagnostics installation,

or it can be installed through the SPP (" HP Service Pack for ProLiant " on page 57 ).

Erase Utility

CAUTION: Perform a backup before running the System Erase Utility. The utility sets the system to its original factory state, deletes the current hardware configuration information, including array setup and disk partitioning, and erases all connected hard drives completely. Refer to the instructions for using this utility.

The Erase utility enables you to erase system CMOS, NVRAM, and hard drives. Run the Erase Utility if you must erase the system for the following reasons:

You want to install a new operating system on a server blade with an existing operating system.

You encounter an error when completing the steps of a factory-installed operating system installation.

To access the Erase Utility, click the Perform Maintenance icon from the Intelligent Provisioning home screen and then select Erase.

Run the Erase utility to:

Reset all settings — erases all drives, NVRAM, and RBSU

Reset all disks — erases all drives

Reset RBSU — erases current RBSU settings

After selecting the appropriate option, click Erase System. Click Exit to reboot the server after the erase task is completed. Click Cancel Erase to exit the utility without erasing.

Software and configuration utilities 55

HP Insight Remote Support software

HP strongly recommends that you install HP Insight Remote Support software to complete the installation or upgrade of your product and to enable enhanced delivery of your HP Warranty, HP Care Pack Service, or

HP contractual support agreement. HP Insight Remote Support supplements your monitoring 24 x 7 to ensure maximum system availability by providing intelligent event diagnosis, and automatic, secure submission of hardware event notifications to HP, which will initiate a fast and accurate resolution, based on your product’s service level. Notifications may be sent to your authorized HP Channel Partner for on-site service, if configured and available in your country. The software is available in two variants:

HP Insight Remote Support Standard: This software supports server and storage devices and is optimized for environments with 1–50 servers. Ideal for customers who can benefit from proactive notification but do not need proactive service delivery and integration with a management platform.

HP Insight Remote Support Advanced: For customers with mid-size to large environments with over 500 devices who require HP Proactive Services, or customers currently using HP Operations Manager or

SAP Solution Manager to manage their environment, HP recommends installing the latest HP Insight

Remote Support Advanced software. This software provides comprehensive remote monitoring and proactive service support for nearly all HP servers, storage, network, and SAN environments, plus selected non-HP servers that have a support obligation with HP. It is integrated with HP Systems Insight

Manager. A dedicated server is recommended to host both HP Systems Insight Manager and HP Insight

Remote Support Advanced.

Details for both versions are available on the HP website ( http://www.hp.com/go/insightremotesupport ).

To download the software, go to Software Depot ( http://www.software.hp.com

).

Select Insight Remote Support from the menu on the right.

The HP Insight Remote Support software release notes detail the specific prerequisites, supported hardware, and associated operating systems. For more information:

See the HP Insight Remote Support Standard Release Notes on the HP website

( http://www.hp.com/go/insightremotestandard-docs ).

See the HP Insight Remote Support Advanced Release Notes on the HP website

( http://www.hp.com/go/insightremoteadvanced-docs ).

Scripting Toolkit

The Scripting Toolkit is a server deployment product that enables you to build an unattended automated installation for high-volume server deployments. The Scripting Toolkit is designed to support ProLiant BL, ML,

DL, and SL servers. The toolkit includes a modular set of utilities and important documentation that describes how to apply these tools to build an automated server deployment process.

The Scripting Toolkit provides a flexible way to create standard server configuration scripts. These scripts are used to automate many of the manual steps in the server configuration process. This automated server configuration process cuts time from each deployment, making it possible to scale rapid, high-volume server deployments.

For more information, and to download the Scripting Toolkit, see the HP website

( http://www.hp.com/go/ProLiantSTK ).

Software and configuration utilities 56

HP Service Pack for ProLiant

SPP is a release set that contains a comprehensive collection of firmware and system software components, all tested together as a single solution stack for HP ProLiant servers, their options, BladeSystem enclosures, and limited HP external storage.

SPP has several key features for updating HP ProLiant servers. Using HP SUM as the deployment tool, SPP can be used in an online mode on a Windows or Linux hosted operating system, or in an offline mode where the server is booted to the ISO so that the server can be updated automatically with no user interaction or updated in interactive mode.

For more information or to download SPP, see the HP website ( http://www.hp.com/go/spp ).

HP Smart Update Manager

The HP SUM provides intelligent and flexible firmware and software deployment. This technology assists in reducing the complexity of provisioning and updating HP ProLiant Servers, options, and Blades within the data center. HP SUM is used to deploy firmware and software in SPP.

HP SUM enables system administrators to upgrade ROM images efficiently across a wide range of server blades and options. This tool has the following features:

Enables GUI and a command-line, scriptable interface

Provides scriptable, command-line deployment

Requires no agent for remote installations

Enables dependency checking, which ensures appropriate install order and dependency checking between components

Deploys software and firmware on Windows and Linux operating systems

Performs local or remote (one-to-many) online deployment

Deploys firmware and software together

Supports offline and online deployment

Deploys necessary component updates only

Downloads the latest components from Web

Enables direct update of BMC firmware (HP iLO)

For more information about HP SUM and to access the HP Smart Update Manager User Guide, see the HP website ( http://www.hp.com/go/hpsum/documentation ).

HP ROM-Based Setup Utility

RBSU is a configuration utility embedded in ProLiant servers that performs a wide range of configuration activities that can include the following:

Configuring system devices and installed options

Enabling and disabling system features

Displaying system information

Selecting the primary boot controller

Software and configuration utilities 57

Configuring memory options

Language selection

For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP website ( http://www.hp.com/support/rbsu ).

Using RBSU

To use RBSU, use the following keys:

To access RBSU, press the F9 key during power-up when prompted.

To navigate the menu system, use the arrow keys.

To make selections, press the Enter key.

To access Help for a highlighted configuration option, press the F1 key.

IMPORTANT: RBSU automatically saves settings when you press the Enter key. The utility does not prompt you for confirmation of settings before you exit the utility. To change a selected setting, you must select a different setting and press the Enter key.

Default configuration settings are applied to the server at one of the following times:

Upon the first system power-up

After defaults have been restored

Default configuration settings are sufficient for proper typical server operation, but configuration settings can be modified using RBSU. The system will prompt you for access to RBSU with each power-up.

Auto-configuration process

The auto-configuration process automatically runs when you boot the server for the first time. During the power-up sequence, the system ROM automatically configures the entire system without needing any intervention. During this process, the ORCA utility, in most cases, automatically configures the array to a default setting based on the number of drives connected to the server.

NOTE: If the boot drive is not empty or has been written to in the past, ORCA does not automatically configure the array. You must run ORCA to configure the array settings.

NOTE: The server may not support all the following examples.

Drives installed

1

2

3, 4, 5, or 6

More than 6

Drives used

1

2

3, 4, 5, or 6

0

RAID level

RAID 0

RAID 1

RAID 5

None

To change any ORCA default settings and override the auto-configuration process, press the F8 key when prompted.

For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP website ( http://www.hp.com/support/rbsu ).

Software and configuration utilities 58

Boot options

Near the end of the boot process, the boot options screen is displayed. This screen is visible for several seconds before the system attempts to boot from a supported boot device. During this time, you can do the following:

Access RBSU by pressing the F9 key.

Access Intelligent Provisioning Maintenance Menu by pressing the F10 key.

Access the boot menu by pressing the F11 key.

Force a PXE Network boot by pressing the F12 key.

Configuring AMP modes

Not all ProLiant servers support all AMP modes. RBSU provides menu options only for the modes supported by the server. Advanced memory protection within RBSU enables the following advanced memory modes:

Advanced ECC Mode—Provides memory protection beyond Standard ECC. All single-bit failures and some multi-bit failures can be corrected without resulting in system downtime.

Online Spare Mode—Provides protection against failing or degraded DIMMs. Certain memory is set aside as spare, and automatic failover to spare memory occurs when the system detects a degraded

DIMM. DIMMs that are likely to receive a fatal or uncorrectable memory error are removed from operation automatically, resulting in less system downtime.

For DIMM population requirements, see the server-specific user guide.

Re-entering the server serial number and product ID

After you replace the system board, you must re-enter the server blade serial number and the product ID.

1.

2.

During the server blade startup sequence, press the F9 key to access RBSU.

Select the Advanced Options menu.

3.

4.

5.

6.

Select Service Options.

Select Serial Number. The following warning appears:

Warning: The serial number should ONLY be modified by qualified service personnel. This value should always match the serial number located on the chassis.

Press the Enter key to clear the warning.

Enter the serial number and press the Enter key.

7.

8.

9.

10.

11.

Select Product ID. The following warning appears:

Warning: The Product ID should ONLY be modified by qualified service personnel. This value should always match the Product ID located on the chassis.

Enter the product ID and press the Enter key.

Press the Esc key to close the menu.

Press the Esc key to exit RBSU.

Press the F10 key to confirm exiting RBSU. The server blade automatically reboots.

Software and configuration utilities 59

Utilities and features

Array Configuration Utility

ACU is a utility with the following features:

Runs as a local application or remote service accessed through the HP System Management Homepage

Supports online array capacity expansion, logical drive extension, assignment of online spares, and

RAID or stripe size migration

Suggests the optimum configuration for an unconfigured system

For supported controllers, provides access to licensed features, including: o

Moving and deleting individual logical volumes o o o o o

Advanced Capacity Expansion (SATA to SAS and SAS to SATA)

Offline Split Mirror

RAID 6 and RAID 60

RAID 1 (ADM) and RAID 10 (ADM)

HP Drive Erase o

Video-On-Demand Advanced Controller Settings

Provides different operating modes, enabling faster configuration or greater control over the configuration options

Remains available any time that the server is on

Displays on-screen tips for individual steps of a configuration procedure

Provides context-sensitive searchable help content

Provides diagnostic and SmartSSD Wear Gauge functionality on the Diagnostics tab

ACU is now available as an embedded utility, starting with HP ProLiant Gen8 servers. To access ACU, use one of the following methods:

If an optional controller is not installed, press F10 during boot.

If an optional controller is installed, when the system recognizes the controller during POST, press F5.

For optimum performance, the minimum display settings are 1024 × 768 resolution and 16-bit color. Servers running Microsoft® operating systems require one of the following supported browsers:

Internet Explorer 6.0 or later

Mozilla Firefox 2.0 or later

For Linux servers, see the README.TXT file for additional browser and support information.

For more information about the controller and its features, see the HP Smart Array Controllers for HP ProLiant

Servers User Guide on the HP website ( http://www.hp.com/support/SAC_UG_ProLiantServers_en ). To configure arrays, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP website ( http://www.hp.com/support/CASAC_RG_en ).

Software and configuration utilities 60

Option ROM Configuration for Arrays

Before installing an operating system, you can use the ORCA utility to create the first logical drive, assign

RAID levels, and establish online spare configurations.

The utility also provides support for the following functions:

Reconfiguring one or more logical drives

Viewing the current logical drive configuration

Deleting a logical drive configuration

Setting the controller to be the boot controller

Selecting the boot volume

If you do not use the utility, ORCA will default to the standard configuration.

For more information regarding the default configurations that ORCA uses, see the HP ROM-Based Setup

Utility User Guide on the Documentation CD or the HP website ( http://www.hp.com/support/rbsu ).

For more information about the controller and its features, see the HP Smart Array Controllers for HP ProLiant

Servers User Guide on the HP website ( http://www.hp.com/support/SAC_UG_ProLiantServers_en ). To configure arrays, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP website ( http://www.hp.com/support/CASAC_RG_en ).

ROMPaq utility

The ROMPaq utility enables you to upgrade the system firmware (BIOS). To upgrade the firmware, insert a

ROMPaq USB Key into an available USB port and boot the system. In addition to ROMPaq, Online Flash

Components for Windows and Linux operating systems are available for updating the system firmware.

The ROMPaq utility checks the system and provides a choice (if more than one exists) of available firmware revisions.

For more information, see the Download drivers and software page for the server blade. To access the server-specific page, enter the following web address into the browser: http://www.hp.com/support/<servername>

For example: http://www.hp.com/support/dl360g6

Automatic Server Recovery

ASR is a feature that causes the system to restart when a catastrophic operating system error occurs, such as a blue screen, ABEND (does not apply to HP ProLiant DL980 Servers), or panic. A system fail-safe timer, the

ASR timer, starts when the System Management driver, also known as the Health Driver, is loaded. When the operating system is functioning properly, the system periodically resets the timer. However, when the operating system fails, the timer expires and restarts the server.

ASR increases server availability by restarting the server within a specified time after a system hang. At the same time, the HP SIM console notifies you by sending a message to a designated pager number that ASR has restarted the system. You can disable ASR from the System Management Homepage or through RBSU.

Software and configuration utilities 61

USB support

HP provides both standard USB 2.0 support and legacy USB 2.0 support. Standard support is provided by the OS through the appropriate USB device drivers. Before the OS loads, HP provides support for USB devices through legacy USB support, which is enabled by default in the system ROM.

Legacy USB support provides USB functionality in environments where USB support is not available normally.

Specifically, HP provides legacy USB functionality for the following:

POST

RBSU

Diagnostics

DOS

Operating environments which do not provide native USB support

Redundant ROM support

The server blade enables you to upgrade or configure the ROM safely with redundant ROM support. The server blade has a single ROM that acts as two separate ROM images. In the standard implementation, one side of the ROM contains the current ROM program version, while the other side of the ROM contains a backup version.

NOTE: The server ships with the same version programmed on each side of the ROM.

Safety and security benefits

When you flash the system ROM, ROMPaq writes over the backup ROM and saves the current ROM as a backup, enabling you to switch easily to the alternate ROM version if the new ROM becomes corrupted for any reason. This feature protects the existing ROM version, even if you experience a power failure while flashing the ROM.

Keeping the system current

Drivers

IMPORTANT: Always perform a backup before installing or updating device drivers.

The server blade includes new hardware that may not have driver support on all OS installation media.

If you are installing an Intelligent Provisioning-supported OS, use Intelligent Provisioning (on page 54 ) and its

Configure and Install feature to install the OS and latest supported drivers.

If you do not use Intelligent Provisioning to install an OS, drivers for some of the new hardware are required.

These drivers, as well as other option drivers, ROM images, and value-add software can be downloaded as part of an SPP.

Software and configuration utilities 62

If you are installing drivers from SPP, be sure that you are using the latest SPP version that your server blade supports. To verify that your server blade is using the latest supported version and for more information about

SPP, see the HP website ( http://www.hp.com/go/spp/download ).

To directly locate the OS drivers for a particular server blade, enter the following web address into the browser: http://www.hp.com/support/<servername>

In place of <servername>, enter the server name.

For example: http://www.hp.com/support/dl360g6

Software and firmware

Software and firmware should be updated before using the server for the first time, unless any installed software or components require an older version. For system software and firmware updates, download the

SPP (" HP Service Pack for ProLiant " on page 57 ) from the HP website (

http://www.hp.com/go/spp ).

Version control

The VCRM and VCA are web-enabled Insight Management Agents tools that HP SIM uses to schedule software update tasks to the entire enterprise.

VCRM manages the repository for SPP. Administrators can view the SPP contents or configure VCRM to automatically update the repository with internet downloads of the latest software and firmware from

HP.

VCA compares installed software versions on the node with updates available in the VCRM managed repository. Administrators configure VCA to point to a repository managed by VCRM.

For more information about version control tools, see the HP Systems Insight Manager User Guide, the HP

Version Control Agent User Guide, and the HP Version Control Repository User Guide on the HP website

( http://www.hp.com/go/hpsim ).

HP Operating Systems and Virtualization Software Support for

ProLiant Servers

For information about specific versions of a supported operating system, see the HP website

( http://www.hp.com/go/ossupport ).

Change control and proactive notification

HP offers Change Control and Proactive Notification to notify customers 30 to 60 days in advance of upcoming hardware and software changes on HP commercial products.

For more information, refer to the HP website ( http://www.hp.com/go/pcn ).

Software and configuration utilities 63

Troubleshooting

Troubleshooting resources

The HP ProLiant Gen8 Troubleshooting Guide, Volume I: Troubleshooting provides procedures for resolving common problems and comprehensive courses of action for fault isolation and identification, issue resolution, and software maintenance on ProLiant servers and server blades. To view the guide, select a language:

English ( http://www.hp.com/support/ProLiant_TSG_v1_en )

French ( http://www.hp.com/support/ProLiant_TSG_v1_fr )

Spanish ( http://www.hp.com/support/ProLiant_TSG_v1_sp )

German ( http://www.hp.com/support/ProLiant_TSG_v1_gr )

Japanese ( http://www.hp.com/support/ProLiant_TSG_v1_jp )

Simplified Chinese ( http://www.hp.com/support/ProLiant_TSG_v1_sc )

The HP ProLiant Gen8 Troubleshooting Guide, Volume II: Error Messages provides a list of error messages and information to assist with interpreting and resolving error messages on ProLiant servers and server blades. To view the guide, select a language:

English ( http://www.hp.com/support/ProLiant_EMG_v1_en )

French ( http://www.hp.com/support/ProLiant_EMG_v1_fr )

Spanish ( http://www.hp.com/support/ProLiant_EMG_v1_sp )

German ( http://www.hp.com/support/ProLiant_EMG_v1_gr )

Japanese ( http://www.hp.com/support/ProLiant_EMG_v1_jp )

Simplified Chinese ( http://www.hp.com/support/ProLiant_EMG_v1_sc )

Troubleshooting 64

Battery replacement

If the server blade no longer automatically displays the correct date and time, you may need to replace the battery that provides power to the real-time clock. Under normal use, battery life is 5 to 10 years.

WARNING: The computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not properly handled. To reduce the risk of personal injury:

Do not attempt to recharge the battery.

• Do not expose the battery to temperatures higher than 60°C (140°F).

Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.

Replace only with the spare designated for this product.

To remove the component:

1.

2.

Power down the server blade (on page 12 ).

Remove the server blade (on page 13 ).

3.

4.

5.

Access the internal server components.

Identify the battery location (" System board components " on page 8 ).

Remove the system battery.

IMPORTANT: Replacing the system board battery resets the system ROM to its default configuration. After replacing the battery, reconfigure the system through RBSU.

To replace the component, reverse the removal procedure.

For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider.

Battery replacement 65

Regulatory compliance notices

Regulatory compliance identification numbers

For the purpose of regulatory compliance certifications and identification, this product has been assigned a unique regulatory model number. The regulatory model number can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to this regulatory model number. The regulatory model number is not the marketing name or model number of the product.

Federal Communications Commission notice

Part 15 of the Federal Communications Commission (FCC) Rules and Regulations has established Radio

Frequency (RF) emission limits to provide an interference-free radio frequency spectrum. Many electronic devices, including computers, generate RF energy incidental to their intended function and are, therefore, covered by these rules. These rules place computers and related peripheral devices into two classes, A and

B, depending upon their intended installation. Class A devices are those that may reasonably be expected to be installed in a business or commercial environment. Class B devices are those that may reasonably be expected to be installed in a residential environment (for example, personal computers). The FCC requires devices in both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the user.

FCC rating label

The FCC rating label on the device shows the classification (A or B) of the equipment. Class B devices have an FCC logo or ID on the label. Class A devices do not have an FCC logo or ID on the label. After you determine the class of the device, refer to the corresponding statement.

FCC Notice, Class A Equipment

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to

Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at personal expense.

FCC Notice, Class B Equipment

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to

Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to

Regulatory compliance notices 66

radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit that is different from that to which the receiver is connected.

Consult the dealer or an experienced radio or television technician for help.

Declaration of conformity for products marked with the FCC logo, United States only

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

For questions regarding this product, contact us by mail or telephone:

Hewlett-Packard Company

P. O. Box 692000, Mail Stop 530113

Houston, Texas 77269-2000

1-800-HP-INVENT (1-800-474-6836). (For continuous quality improvement, calls may be recorded or monitored.)

For questions regarding this FCC declaration, contact us by mail or telephone:

Hewlett-Packard Company

P. O. Box 692000, Mail Stop 510101

Houston, Texas 77269-2000

1­281-514-3333

To identify this product, refer to the part, series, or model number found on the product.

Modifications

The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Hewlett-Packard Company may void the user’s authority to operate the equipment.

Cables

Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in order to maintain compliance with FCC Rules and Regulations.

Canadian notice (Avis Canadien)

Class A equipment

Regulatory compliance notices 67

This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment

Regulations.

Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.

Class B equipment

This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment

Regulations.

Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.

European Union regulatory notice

Products bearing the CE marking comply with the following EU Directives:

Low Voltage Directive 2006/95/EC

EMC Directive 2004/108/EC

Ecodesign Directive 2009/125/EC, where applicable

CE compliance of this product is valid if powered with the correct CE-marked AC adapter provided by HP.

Compliance with these directives implies conformity to applicable harmonized European standards

(European Norms) that are listed in the EU Declaration of Conformity issued by HP for this product or product family and available (in English only) either within the product documentation or at the following HP website

( http://www.hp.eu/certificates ) (type the product number in the search field).

The compliance is indicated by one of the following conformity markings placed on the product:

For non-telecommunications products and for EU harmonized telecommunications products, such as

Bluetooth® within power class below 10mW.

For EU non-harmonized telecommunications products (If applicable, a 4-digit notified body number is inserted between CE and !).

Please refer to the regulatory label provided on the product.

The point of contact for regulatory matters is Hewlett-Packard GmbH, Dept./MS: HQ-TRE, Herrenberger

Strasse 140, 71034 Boeblingen, GERMANY.

Disposal of waste equipment by users in private households in the European Union

Regulatory compliance notices 68

This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product.

Japanese notice

BSMI notice

Korean notice

Class A equipment

Regulatory compliance notices 69

Class B equipment

Chinese notice

Class A equipment

Vietnam compliance marking notice

This marking is for applicable products only.

Ukraine notice

Laser compliance

This product may be provided with an optical storage device (that is, CD or DVD drive) and/or fiber optic transceiver. Each of these devices contains a laser that is classified as a Class 1 Laser Product in accordance with US FDA regulations and the IEC 60825-1. The product does not emit hazardous laser radiation.

Each laser product complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser

Notice No. 50, dated June 24, 2007; and with IEC 60825-1:2007.

Regulatory compliance notices 70

WARNING: Use of controls or adjustments or performance of procedures other than those specified herein or in the laser product's installation guide may result in hazardous radiation exposure. To reduce the risk of exposure to hazardous radiation:

• Do not try to open the module enclosure. There are no user-serviceable components inside.

Do not operate controls, make adjustments, or perform procedures to the laser device other than those specified herein.

• Allow only HP Authorized Service technicians to repair the unit.

The Center for Devices and Radiological Health (CDRH) of the U.S. Food and Drug Administration implemented regulations for laser products on August 2, 1976. These regulations apply to laser products manufactured from August 1, 1976. Compliance is mandatory for products marketed in the United States.

Battery replacement notice

WARNING: The computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not properly handled. To reduce the risk of personal injury:

Do not attempt to recharge the battery.

• Do not expose the battery to temperatures higher than 60°C (140°F).

Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.

Batteries, battery packs, and accumulators should not be disposed of together with the general household waste. To forward them to recycling or proper disposal, use the public collection system or return them to HP, an authorized HP Partner, or their agents.

For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider.

Taiwan battery recycling notice

The Taiwan EPA requires dry battery manufacturing or importing firms in accordance with Article 15 of the

Waste Disposal Act to indicate the recovery marks on the batteries used in sales, giveaway or promotion.

Contact a qualified Taiwanese recycler for proper battery disposal.

Acoustics statement for Germany (Geräuschemission)

Schalldruckpegel L pA

< 70 dB(A)

Zuschauerpositionen (bystander positions), Normaler Betrieb (normal operation)

Regulatory compliance notices 71

Nach ISO 7779:1999 (Typprüfung)

Regulatory compliance notices 72

Electrostatic discharge

Preventing electrostatic discharge

To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device.

To prevent electrostatic damage:

Avoid hand contact by transporting and storing products in static-safe containers.

Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations.

Place parts on a grounded surface before removing them from their containers.

Avoid touching pins, leads, or circuitry.

Always be properly grounded when touching a static-sensitive component or assembly.

Grounding methods to prevent electrostatic discharge

Several methods are used for grounding. Use one or more of the following methods when handling or installing electrostatic-sensitive parts:

Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist straps are flexible straps with a minimum of 1 megohm ±10 percent resistance in the ground cords. To provide proper ground, wear the strap snug against the skin.

Use heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats.

Use conductive field service tools.

Use a portable field service kit with a folding static-dissipating work mat.

If you do not have any of the suggested equipment for proper grounding, have an authorized reseller install the part.

For more information on static electricity or assistance with product installation, contact an authorized reseller.

Electrostatic discharge 73

Specifications

Environmental specifications

Specification Value

Temperature range*

Operating

10°C to 35°C (50°F to 95°F)

Non-operating

-30°C to 60°C (-22°F to 140°F)

Relative humidity

(noncondensing)**

Operating

10% to 90% @ 28°C (82.4°F)

Non-operating

5% to 95% @ 38.7°C (101.7°F)

Altitude†

Operating

3050 m (10,000 ft)

Non-operating

9144 m (30,000 ft)

* The following temperature conditions and limitations apply:

- All temperature ratings shown are for sea level.

- An altitude derating of 1°C per 304.8 m (1.8°F per 1,000 ft) up to 3048 m (10,000 ft) applies.

- No direct sunlight is allowed.

-The maximum permissible rate of change is 10°C/hr (18°F/hr).

- The type and number of options installed may reduce the upper temperature and humidity limits.

- Operating with a fan fault or above 30°C (86°F) may reduce system performance.

** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F).

†Maximum storage altitude corresponds to a minimum pressure of 70 kPa (10.1 psia).

Server blade specifications

Specification

Height

Depth

Width

Weight (maximum)

Value

5.56 cm (2.19 in)

50.95 cm (20.06 in)

18.16 cm (7.15 in)

6.3 kg (13.9 lb)

Specifications 74

Support and other resources

Before you contact HP

Be sure to have the following information available before you call HP:

Active Health System log

Download and have available an Active Health System log for 3 days before the failure was detected.

For more information, see the HP iLO 4 User Guide or HP Intelligent Provisioning User Guide on the HP website ( http://www.hp.com/go/ilo/docs ).

Onboard Administrator SHOW ALL report (for HP BladeSystem products only)

For more information on obtaining the Onboard Administrator SHOW ALL report, see the HP website

( http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&objectID=c

02843807 ).

Technical support registration number (if applicable)

Product serial number

Product model name and number

Product identification number

Applicable error messages

Add-on boards or hardware

Third-party hardware or software

Operating system type and revision level

HP contact information

For United States and worldwide contact information, see the Contact HP website

( http://www.hp.com/go/assistance ).

In the United States:

To contact HP by phone, call 1-800-334-5144. For continuous quality improvement, calls may be recorded or monitored.

If you have purchased a Care Pack (service upgrade), see the Support & Drivers website

( http://www8.hp.com/us/en/support-drivers.html

). If the problem cannot be resolved at the website, call 1-800-633-3600. For more information about Care Packs, see the HP website

( http://pro-aq-sama.houston.hp.com/services/cache/10950-0-0-225-121.html

).

Customer Self Repair

HP products are designed with many Customer Self Repair (CSR) parts to minimize repair time and allow for greater flexibility in performing defective parts replacement. If during the diagnosis period HP (or HP service

Support and other resources 75

providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship that part directly to you for replacement. There are two categories of CSR parts:

Mandatory—Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be charged for the travel and labor costs of this service.

Optional—Parts for which customer self repair is optional. These parts are also designed for customer self repair. If, however, you require that HP replace them for you, there may or may not be additional charges, depending on the type of warranty service designated for your product.

NOTE: Some HP parts are not designed for customer self repair. In order to satisfy the customer warranty,

HP requires that an authorized service provider replace the part. These parts are identified as "No" in the

Illustrated Parts Catalog.

Based on availability and where geography permits, CSR parts will be shipped for next business day delivery. Same day or four-hour delivery may be offered at an additional charge where geography permits.

If assistance is required, you can call the HP Technical Support Center and a technician will help you over the telephone. HP specifies in the materials shipped with a replacement CSR part whether a defective part must be returned to HP. In cases where it is required to return the defective part to HP, you must ship the defective part back to HP within a defined period of time, normally five (5) business days. The defective part must be returned with the associated documentation in the provided shipping material. Failure to return the defective part may result in HP billing you for the replacement. With a customer self repair, HP will pay all shipping and part return costs and determine the courier/carrier to be used.

For more information about HP's Customer Self Repair program, contact your local service provider. For the

North American program, refer to the HP website ( http://www.hp.com/go/selfrepair ).

Réparation par le client (CSR)

Les produits HP comportent de nombreuses pièces CSR (Customer Self Repair = réparation par le client) afin de minimiser les délais de réparation et faciliter le remplacement des pièces défectueuses. Si pendant la période de diagnostic, HP (ou ses partenaires ou mainteneurs agréés) détermine que la réparation peut être effectuée à l'aide d'une pièce CSR, HP vous l'envoie directement. Il existe deux catégories de pièces CSR:

Obligatoire - Pièces pour lesquelles la réparation par le client est obligatoire. Si vous demandez à HP de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront facturés.

Facultatif - Pièces pour lesquelles la réparation par le client est facultative. Ces pièces sont également conçues pour permettre au client d'effectuer lui-même la réparation. Toutefois, si vous demandez à HP de remplacer ces pièces, l'intervention peut ou non vous être facturée, selon le type de garantie applicable à votre produit.

REMARQUE: Certaines pièces HP ne sont pas conçues pour permettre au client d'effectuer lui-même la réparation. Pour que la garantie puisse s'appliquer, HP exige que le remplacement de la pièce soit effectué par un Mainteneur Agréé. Ces pièces sont identifiées par la mention "Non" dans le Catalogue illustré.

Les pièces CSR sont livrées le jour ouvré suivant, dans la limite des stocks disponibles et selon votre situation géographique. Si votre situation géographique le permet et que vous demandez une livraison le jour même ou dans les 4 heures, celle-ci vous sera facturée. Pour bénéficier d'une assistance téléphonique, appelez le

Centre d'assistance technique HP. Dans les documents envoyés avec la pièce de rechange CSR, HP précise s'il est nécessaire de lui retourner la pièce défectueuse. Si c'est le cas, vous devez le faire dans le délai indiqué, généralement cinq (5) jours ouvrés. La pièce et sa documentation doivent être retournées dans l'emballage fourni. Si vous ne retournez pas la pièce défectueuse, HP se réserve le droit de vous facturer les coûts de remplacement. Dans le cas d'une pièce CSR, HP supporte l'ensemble des frais d'expédition et de retour, et détermine la société de courses ou le transporteur à utiliser.

Support and other resources 76

Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'informations sur ce programme en Amérique du Nord, consultez le site Web HP

( http://www.hp.com/go/selfrepair ).

Riparazione da parte del cliente

Per abbreviare i tempi di riparazione e garantire una maggiore flessibilità nella sostituzione di parti difettose, i prodotti HP sono realizzati con numerosi componenti che possono essere riparati direttamente dal cliente (CSR, Customer Self Repair). Se in fase di diagnostica HP (o un centro di servizi o di assistenza

HP) identifica il guasto come riparabile mediante un ricambio CSR, HP lo spedirà direttamente al cliente per la sostituzione. Vi sono due categorie di parti CSR:

Obbligatorie – Parti che devono essere necessariamente riparate dal cliente. Se il cliente ne affida la riparazione ad HP, deve sostenere le spese di spedizione e di manodopera per il servizio.

Opzionali – Parti la cui riparazione da parte del cliente è facoltativa. Si tratta comunque di componenti progettati per questo scopo. Se tuttavia il cliente ne richiede la sostituzione ad HP, potrebbe dover sostenere spese addizionali a seconda del tipo di garanzia previsto per il prodotto.

NOTA: alcuni componenti HP non sono progettati per la riparazione da parte del cliente. Per rispettare la garanzia, HP richiede che queste parti siano sostituite da un centro di assistenza autorizzato. Tali parti sono identificate da un "No" nel Catalogo illustrato dei componenti.

In base alla disponibilità e alla località geografica, le parti CSR vengono spedite con consegna entro il giorno lavorativo seguente. La consegna nel giorno stesso o entro quattro ore è offerta con un supplemento di costo solo in alcune zone. In caso di necessità si può richiedere l'assistenza telefonica di un addetto del centro di supporto tecnico HP. Nel materiale fornito con una parte di ricambio CSR, HP specifica se il cliente deve restituire dei componenti. Qualora sia richiesta la resa ad HP del componente difettoso, lo si deve spedire ad HP entro un determinato periodo di tempo, generalmente cinque (5) giorni lavorativi. Il componente difettoso deve essere restituito con la documentazione associata nell'imballo di spedizione fornito. La mancata restituzione del componente può comportare la fatturazione del ricambio da parte di HP.

Nel caso di riparazione da parte del cliente, HP sostiene tutte le spese di spedizione e resa e sceglie il corriere/vettore da utilizzare.

Per ulteriori informazioni sul programma CSR di HP contattare il centro di assistenza di zona. Per il programma in Nord America fare riferimento al sito Web HP ( http://www.hp.com/go/selfrepair ).

Customer Self Repair

HP Produkte enthalten viele CSR-Teile (Customer Self Repair), um Reparaturzeiten zu minimieren und höhere

Flexibilität beim Austausch defekter Bauteile zu ermöglichen. Wenn HP (oder ein HP Servicepartner) bei der

Diagnose feststellt, dass das Produkt mithilfe eines CSR-Teils repariert werden kann, sendet Ihnen HP dieses

Bauteil zum Austausch direkt zu. CSR-Teile werden in zwei Kategorien unterteilt:

Zwingend – Teile, für die das Customer Self Repair-Verfahren zwingend vorgegeben ist. Wenn Sie den

Austausch dieser Teile von HP vornehmen lassen, werden Ihnen die Anfahrt- und Arbeitskosten für diesen

Service berechnet.

Optional – Teile, für die das Customer Self Repair-Verfahren optional ist. Diese Teile sind auch für Customer

Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche

Kosten anfallen.

Support and other resources 77

HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des

Kunden zu erfüllen, muss das Teil von einem HP Servicepartner ersetzt werden. Im illustrierten Teilekatalog sind diese Teile mit „No“ bzw. „Nein“ gekennzeichnet.

CSR-Teile werden abhängig von der Verfügbarkeit und vom Lieferziel am folgenden Geschäftstag geliefert.

Für bestimmte Standorte ist eine Lieferung am selben Tag oder innerhalb von vier Stunden gegen einen

Aufpreis verfügbar. Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen lassen. Den Materialien, die mit einem CSR-Ersatzteil geliefert werden, können Sie entnehmen, ob das defekte Teil an HP zurückgeschickt werden muss. Wenn es erforderlich ist, das defekte Teil an HP zurückzuschicken, müssen Sie dies innerhalb eines vorgegebenen

Zeitraums tun, in der Regel innerhalb von fünf (5) Geschäftstagen. Das defekte Teil muss mit der zugehörigen

Dokumentation in der Verpackung zurückgeschickt werden, die im Lieferumfang enthalten ist. Wenn Sie das defekte Teil nicht zurückschicken, kann HP Ihnen das Ersatzteil in Rechnung stellen. Im Falle von Customer

Self Repair kommt HP für alle Kosten für die Lieferung und Rücksendung auf und bestimmt den

Kurier-/Frachtdienst.

Weitere Informationen über das HP Customer Self Repair Programm erhalten Sie von Ihrem Servicepartner vor Ort. Informationen über das CSR-Programm in Nordamerika finden Sie auf der HP Website unter

( http://www.hp.com/go/selfrepair ).

Reparaciones del propio cliente

Los productos de HP incluyen muchos componentes que el propio usuario puede reemplazar (Customer Self

Repair, CSR) para minimizar el tiempo de reparación y ofrecer una mayor flexibilidad a la hora de realizar sustituciones de componentes defectuosos. Si, durante la fase de diagnóstico, HP (o los proveedores o socios de servicio de HP) identifica que una reparación puede llevarse a cabo mediante el uso de un componente

CSR, HP le enviará dicho componente directamente para que realice su sustitución. Los componentes CSR se clasifican en dos categorías:

Obligatorio: componentes para los que la reparación por parte del usuario es obligatoria. Si solicita a

HP que realice la sustitución de estos componentes, tendrá que hacerse cargo de los gastos de desplazamiento y de mano de obra de dicho servicio.

Opcional: componentes para los que la reparación por parte del usuario es opcional. Estos componentes también están diseñados para que puedan ser reparados por el usuario. Sin embargo, si precisa que HP realice su sustitución, puede o no conllevar costes adicionales, dependiendo del tipo de servicio de garantía correspondiente al producto.

NOTA: Algunos componentes no están diseñados para que puedan ser reparados por el usuario. Para que el usuario haga valer su garantía, HP pone como condición que un proveedor de servicios autorizado realice la sustitución de estos componentes. Dichos componentes se identifican con la palabra "No" en el catálogo ilustrado de componentes.

Según la disponibilidad y la situación geográfica, los componentes CSR se enviarán para que lleguen a su destino al siguiente día laborable. Si la situación geográfica lo permite, se puede solicitar la entrega en el mismo día o en cuatro horas con un coste adicional. Si precisa asistencia técnica, puede llamar al Centro de asistencia técnica de HP y recibirá ayuda telefónica por parte de un técnico. Con el envío de materiales para la sustitución de componentes CSR, HP especificará si los componentes defectuosos deberán devolverse a HP. En aquellos casos en los que sea necesario devolver algún componente a HP, deberá hacerlo en el periodo de tiempo especificado, normalmente cinco días laborables. Los componentes defectuosos deberán devolverse con toda la documentación relacionada y con el embalaje de envío. Si no enviara el componente defectuoso requerido, HP podrá cobrarle por el de sustitución. En el caso de todas

Support and other resources 78

sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes y escogerá la empresa de transporte que se utilice para dicho servicio.

Para obtener más información acerca del programa de Reparaciones del propio cliente de HP, póngase en contacto con su proveedor de servicios local. Si está interesado en el programa para Norteamérica, visite la página web de HP siguiente ( http://www.hp.com/go/selfrepair ).

Customer Self Repair

Veel onderdelen in HP producten zijn door de klant zelf te repareren, waardoor de reparatieduur tot een minimum beperkt kan blijven en de flexibiliteit in het vervangen van defecte onderdelen groter is. Deze onderdelen worden CSR-onderdelen (Customer Self Repair) genoemd. Als HP (of een HP Service Partner) bij de diagnose vaststelt dat de reparatie kan worden uitgevoerd met een CSR-onderdeel, verzendt HP dat onderdeel rechtstreeks naar u, zodat u het defecte onderdeel daarmee kunt vervangen. Er zijn twee categorieën CSR-onderdelen:

Verplicht: Onderdelen waarvoor reparatie door de klant verplicht is. Als u HP verzoekt deze onderdelen voor u te vervangen, worden u voor deze service reiskosten en arbeidsloon in rekening gebracht.

Optioneel: Onderdelen waarvoor reparatie door de klant optioneel is. Ook deze onderdelen zijn ontworpen voor reparatie door de klant. Als u echter HP verzoekt deze onderdelen voor u te vervangen, kunnen daarvoor extra kosten in rekening worden gebracht, afhankelijk van het type garantieservice voor het product.

OPMERKING: Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door de klant. In verband met de garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden vervangen.

Deze onderdelen worden in de geïllustreerde onderdelencatalogus aangemerkt met "Nee".

Afhankelijk van de leverbaarheid en de locatie worden CSR-onderdelen verzonden voor levering op de eerstvolgende werkdag. Levering op dezelfde dag of binnen vier uur kan tegen meerkosten worden aangeboden, indien dit mogelijk is gezien de locatie. Indien assistentie gewenst is, belt u een HP Service

Partner om via de telefoon technische ondersteuning te ontvangen. HP vermeldt in de documentatie bij het vervangende CSR-onderdeel of het defecte onderdeel aan HP moet worden geretourneerd. Als het defecte onderdeel aan HP moet worden teruggezonden, moet u het defecte onderdeel binnen een bepaalde periode, gewoonlijk vijf (5) werkdagen, retourneren aan HP. Het defecte onderdeel moet met de bijbehorende documentatie worden geretourneerd in het meegeleverde verpakkingsmateriaal. Als u het defecte onderdeel niet terugzendt, kan HP u voor het vervangende onderdeel kosten in rekening brengen. Bij reparatie door de klant betaalt HP alle verzendkosten voor het vervangende en geretourneerde onderdeel en kiest HP zelf welke koerier/transportonderneming hiervoor wordt gebruikt.

Neem contact op met een Service Partner voor meer informatie over het Customer Self Repair programma van HP. Informatie over Service Partners vindt u op de HP website ( http://www.hp.com/go/selfrepair ).

Reparo feito pelo cliente

Os produtos da HP são projetados com muitas peças para reparo feito pelo cliente (CSR) de modo a minimizar o tempo de reparo e permitir maior flexibilidade na substituição de peças com defeito. Se, durante o período de diagnóstico, a HP (ou fornecedores/parceiros de serviço da HP) concluir que o reparo pode ser efetuado pelo uso de uma peça CSR, a peça de reposição será enviada diretamente ao cliente.

Existem duas categorias de peças CSR:

Obrigatória – Peças cujo reparo feito pelo cliente é obrigatório. Se desejar que a HP substitua essas peças, serão cobradas as despesas de transporte e mão-de-obra do serviço.

Support and other resources 79

Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver ou não a cobrança de taxa adicional, dependendo do tipo de serviço de garantia destinado ao produto.

OBSERVAÇÃO: Algumas peças da HP não são projetadas para o reparo feito pelo cliente. A fim de cumprir a garantia do cliente, a HP exige que um técnico autorizado substitua a peça. Essas peças estão identificadas com a marca "No" (Não), no catálogo de peças ilustrado.

Conforme a disponibilidade e o local geográfico, as peças CSR serão enviadas no primeiro dia útil após o pedido. Onde as condições geográficas permitirem, a entrega no mesmo dia ou em quatro horas pode ser feita mediante uma taxa adicional. Se precisar de auxílio, entre em contato com o Centro de suporte técnico da HP para que um técnico o ajude por telefone. A HP especifica nos materiais fornecidos com a peça CSR de reposição se a peça com defeito deve ser devolvida à HP. Nos casos em que isso for necessário, é preciso enviar a peça com defeito à HP dentro do período determinado, normalmente cinco (5) dias úteis.

A peça com defeito deve ser enviada com a documentação correspondente no material de transporte fornecido. Caso não o faça, a HP poderá cobrar a reposição. Para as peças de reparo feito pelo cliente, a

HP paga todas as despesas de transporte e de devolução da peça e determina a transportadora/serviço postal a ser utilizado.

Para obter mais informações sobre o programa de reparo feito pelo cliente da HP, entre em contato com o fornecedor de serviços local. Para o programa norte-americano, visite o site da HP

( http://www.hp.com/go/selfrepair ).

Support and other resources 80

Support and other resources 81

Support and other resources 82

Acronyms and abbreviations

ABEND abnormal end

ACU

Array Configuration Utility

ADM

Advanced Data Mirroring

AMP

Advanced Memory Protection

ASR

Automatic Server Recovery

FBWC flash-backed write cache iLO

Integrated Lights-Out

IML

Integrated Management Log

LRDIMM

Load Reduced DIMM

LV DIMM

Low voltage DIMM

ORCA

Option ROM Configuration for Arrays

POST

Power-On Self Test

Acronyms and abbreviations 83

PXE

Preboot Execution Environment

RBSU

ROM-Based Setup Utility

RDIMM registered dual in-line memory module

SAS serial attached SCSI

SATA serial ATA

SIM

Systems Insight Manager

UDIMM unregistered dual in-line memory module

UID unit identification

USB universal serial bus

VCA

Version Control Agent

Acronyms and abbreviations 84

Documentation feedback

HP is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback ( mailto:[email protected]

).

Include the document title and part number, version number, or the URL when submitting your feedback.

Documentation feedback 85

Index

A

access panel 14

acoustics statement for Germany 71

ACU (Array Configuration Utility) 52, 60

Advanced ECC memory 38, 39, 59

Array Configuration Utility (ACU) 60

ASR (Automatic Server Recovery) 61

authorized reseller 75

auto-configuration process 58

Automatic Server Recovery (ASR) 61

B

Basic Input/Output System (BIOS) 52, 61

batteries, replacing 65, 71 battery 8, 65, 71 battery replacement notice 65, 71

before you contact HP 75

BIOS (Basic Input/Output System) 52, 61

BIOS upgrade 52, 61

blade blank 25

boot options 59

BSMI notice 69

buttons 6

C

cables 48, 49, 67 cables, FCC compliance 67

cabling 48, 49 cabling, hard drive 49

Canadian notice 67

Change Control 63

Chinese notice 70

class A equipment 66 class B equipment 66

compatibility 52

compliance 66

components 6 components, identification 6

configuration of system 26, 52

connecting to the network 24

connectors 6

contact information 75 contacting HP 75

CSR (customer self repair) 75 customer self repair (CSR) 75

D

Declaration of Conformity 67

default settings 38

device mapping 23

diagnosing problems 64

diagnostic tools 52, 55, 61

diagnostics utility 55

DIMM baffles 14, 15, 39

DIMM identification 37

DIMM installation guidelines 38

DIMM population guidelines 38

DIMM slot locations 8, 10

DIMM slots 38

DIMM tool 11

DIMMs 8, 10, 36

DIMMs, dual-rank 36

DIMMs, quad-rank 36

DIMMs, single- and dual-rank 36

disposal, battery 68, 71

disposal, waste 68

documentation 85 documentation feedback 85

drive bays 6

drive cage, removing 16, 17

drivers 62

drives 8, 20, 27, 49

E

electrostatic discharge 73

enclosure connector 8

environmental specifications 74

Erase Utility 52, 55

error messages 64

European Union notice 68

external cables 49

F

FBWC capacitor cabling 48

FBWC capacitor pack 42, 48

Index 86

FCC (Federal Communications Commission)

notice 66, 67

FCC rating label 66

features 6, 60

Federal Communications Commission (FCC)

notice 66, 67

firmware 63 firmware update 57, 63

firmware upgrade utility, troubleshooting 64

firmware, updating 57, 63

flash-backed write cache capacitor pack 48

FlexibleLOM connectors 8

FlexibleLOM LED 7 front panel buttons 7

front panel components 6

front panel LEDs 7

front panel/drive cage assembly 16, 17 front panel/hard drive cage assembly 16, 17

G

grounding methods 73

H

hard drive backplane connector 8

hard drive bays 6

hard drive cabling 49

hard drive LEDs 8

hard drive, removing 20

hard drives, determining status of 8

hard drives, installing 27 hardware options 27 hardware options installation 27

health driver 61

health LEDs 7 health status LED bar 7

heatsink 30 heatsink blank 30

help resources 75

HP c-Class Blade SUV Cable 6, 11, 49

HP contact information 75

HP Insight Diagnostics 55

HP Insight Diagnostics survey functionality 55

HP Insight Remote Support software 56

HP Service Pack for ProLiant 52, 57

HP Smart memory 35

HP Smart Update Manager overview 52, 57

HP technical support 75

HP website 75

HP, contacting 75

I

identification number 66

iLO (Integrated Lights-Out) 12, 52, 53, 54

IML (Integrated Management Log) 52, 54

Insight Diagnostics 55, 62

installation, enclosure 22

installation, server blade 25

installation, server options 27 installing hardware 27 installing server blade options 27 installing server options 27

installing the access panel 14

Integrated Lights-Out (iLO) 12, 52

Integrated Management Log (IML) 54

Intelligent Provisioning 52, 54

interconnect bay numbering 23

interconnect module 22 interconnect modules, installing 22

J

Japanese notice 69

K

Korean notices 69

L

laser compliance 70 laser devices 70

LED, health 7

LED, power button 7

LED, system power 7

LEDs 6, 8

LEDs, hard drive 8

LEDs, NIC 7

LEDs, SAS hard drive 8

LEDs, troubleshooting 64

LEDs, unit identification (UID) 7

local KVM, accessing a server blade with 49

local media devices, accessing 50

M

maintenance guidelines 62

memory 10, 34, 36, 37, 38 memory configurations 37, 38

memory options 27, 34

memory subsystem architecture 36

memory, Advanced ECC 38, 59

memory, configuration requirements 37

Index 87

memory, configuring 37, 38

memory, online spare 38, 59

mezzanine board connectors 8

mezzanine boards 40 mezzanine card 40 mezzanine connector covers 40

mezzanine connectors 8, 10

modifications, FCC notice 67

N

network connections 24

NIC (network interface card) 8

O

online spare memory 38, 59

online spare population guidelines 39

operating systems 63

operations 12

Option ROM Configuration for Arrays (ORCA) 52,

61

options 22, 52

options installation 22, 27

ORCA (Option ROM Configuration for Arrays) 52,

61

overview 22

P

passwords 46

phone numbers 75

population guidelines, Advanced ECC 39 population order, memory 39

power button LED 7

powering down 12

powering up 12, 58

preparation procedures 12

problem diagnosis 64

processor socket 8

processors 8, 30

product features 52

Product ID 59

Q

QuickSpecs 48, 52

R

RBSU (ROM-Based Setup Utility) 52, 57, 58, 59

RBSU configuration 58

recovery key 46

redundant ROM 62

regulatory compliance identification numbers 66

regulatory compliance notices 66, 68, 71

release button 6

removing the access panel 14

removing the server blade 13

required information 75 resources 75

ROM redundancy 62

ROM-Based Setup Utility (RBSU) 47, 57

ROMPaq utility 52, 61, 62

S

safety considerations 62 safety information 62

SAS controller 18, 19

screwdriver, T-10 Torx 11 screwdriver, T-15 Torx 11

scripted installation 56

serial connector 11

serial label pull tab 6

serial number 59

series number 66

server blade release lever 6

server features and options 27 server options, installing 27

setup 22

Smart Update Manager 52, 57

software 63 software upgrades 63

solid state drive 20 solid state drive, removing 20

specifications 52, 74 specifications, environmental 74 specifications, server blade 74

SPP 57

standards 66

static electricity 73

support 75 support and other resources 75

supported operating systems 63

SUV connector 6, 11, 49

switches, interconnect 22

system board battery 8, 71

system board components 8

system components 6

system configuration settings 62

System Erase Utility 55

system maintenance switch 8, 9

system, keeping current 62

Index 88

T

T-15 Torx screwdriver 11

Taiwan battery recycling notice 71

technical support 75 telephone numbers 75

tool locations 11 tool, DIMM 11 tools 11

Torx screwdriver 11

TPM (Trusted Platform Module) 44, 45, 46, 47

troubleshooting 64 troubleshooting resources 64 troubleshooting, firmware upgrade utility 64

Trusted Platform Module (TPM) 44, 45, 46, 47

U

Ukraine notice 70

updating the system ROM 62

USB connectors 11

USB devices 49

USB support 62

utilities 52, 60

utilities, deployment 52, 56, 57

V

Version Control Agent (VCA) 63

Version Control Repository Manager (VCRM) 63

video connector 11 video connector cabling 11

video devices 49

Vietnam compliance marking notice 70

W

website, HP 75

Index 89

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement

Table of contents

Languages