Installing and connecting the assembly pipe of the indoor unit. Samsung AR24HVSDKWK
Add to My manuals57 Pages
advertisement
Installing and connecting the assembly pipe of the indoor unit
Connect indoor and outdoor units with field-supplied copper pipes by means of flare connections. Use insulated seamless refrigeration grade pipe only, (Cu DHP type according to ISO1337), degreased and deoxidized, suitable for operating pressures of at least 4200 kPa and for burst pressure of at least 20700 kPa. Under no circumstances must sanitary type copper pipe be used.
There are 2 refrigerant pipes of different diameters:
• The smaller one is for the liquid refrigerant
• The larger one is for the gas refrigerant
A short pipe is already fitted to the air conditioner. You may need to extend the pipe using the assembly pipe (optional).
The connection procedure for the refrigerant pipe varies according to the exit position of the pipe when facing the wall:
• Right(A)
• Left(B)
• Underside(C)
• Rear
1. Cut out the appropriate knock-out piece (A, B, C) on the rear of the indoor unit unless you connect the pipe directly from the rear.
2. Smooth the cut edges.
3. Remove the protection caps of the pipes and connect the assembly pipe to each pipe. Tighten the nuts first with your hands, and then with a torque wrench, applying the following torque:
A
C
Outer Diameter
ø6.35 mm
ø9.52 mm
ø12.70 mm
ø15.88 mm
N•m
14~18
Torque kgf•cm
140~180
34~42 350~430
49~61 500~620
68~82 690~830
B
• If you want to shorten or extend the pipes, refer to page 42~43.
4. Cut off the remaining foam insulation.
5. If necessary, bend the pipe to fit along the bottom of the indoor unit.
Then pull it out through the appropriate hole.
The pipe should not project from the rear of the indoor unit.
The bending radius should be 100 mm or more.
6. Pass the pipe through the hole in the wall.
7. For further details on how to connect to the outdoor unit and evacuate the air, refer to page 46~48.
• The pipe will be insulated and fixed permanently into position after finishing the installation and the gas leak test; refer to page 49 for further details.
• Tighten the flare nut with torque wrench according to specified method.
If the flare nut is over-tightened, the flare may break and cause refrigerant gas leakage.
• DO NOT WALL UP THE PIPE CONNECTION !
All refrigerant pipe connection must be easy accessible and serviceable.
�� A3050 CH&XL_IB&IM_DB68-04219A_HP&CO_EN.indd 41
English-41
2014/7/10 16:50:48
advertisement
Related manuals
advertisement
Table of contents
- 4 Safety precautions
- 10 Checking before use
- 12 Checking the name of the parts
- 13 Checking the remote controller
- 15 Basic function
- 17 Adjusting the air flow direction
- 18 Using the Fast function
- 18 Using the Comfort function
- 19 mode
- 20 Setting the On/Off timer
- 21 Using the Auto Clean function
- 22 Using the Single User function
- 22 Using the Virus Doctor function
- 23 Using the Quiet function
- 23 Using the Smart A/C application
- 23 Using the Filter reset
- 24 Cleaning the air conditioner
- 27 Maintaining the air conditioner
- 28 Troubleshooting
- 30 Safety precautions
- 31 Choosing the installation location
- 34 Accessories
- 36 Fixing the installation plate
- 37 Disassembling/Assembling the Cover panel for indoor unit installation
- 39 Connecting the assembly cable
- 41 Installing and connecting the assembly pipe of the indoor unit
- 42 Evacuating the indoor unit
- 42 Cutting or extending the pipe
- 44 Installing and connecting the drain hose of the indoor unit
- 45 Changing direction of the drain hose
- 46 Installing and connecting the drain hose of the outdoor unit
- 46 Evacuating the connected pipes
- 49 Performing the gas leak tests
- 50 Fixing the indoor unit in place
- 50 Fixing the outdoor unit in place
- 51 Smart Install mode
- 53 Final check and trial operation
- 53 Pump down procedure (when removing the product)
- 54 How to connect your extended power cables