40~45 mm
Drain hose
Vinyl Tape Foam Insulation
6. Pass the drain hose under the refrigerant pipe, keeping the drain hose tight.
7. Pass the drain hose through the hole in the wall. Check if it slants downwards as seen in the picture.
8. Using natural drainage method, check the drainage is normal.
Shield
Drain hose Extension drain hose
• The hose will be fixed permanently into position after finishing the installation and the gas leak test; refer to page 49 for further details.
• Make sure the installed direction of the drain hose is correct.
Inadequate installation may cause condensate water leakage.
• If the drain hose is routed inside the room, insulate the hose so that dripping condensation does not damage the furniture or floors.
• DO NOT WALL UP THE DRAIN HOSE CONNECTION !
Drain hose connection must be easy accessible and serviceable.
Changing direction of the drain hose
Change the direction only when it is necessary.
1. Detach the rubber cap with the pliers.
2. Detach the drain hose by pulling it and turning to the left.
3. Insert the drain hose by fixing it with the screw into the groove of the drain hose and the outlet of the drain pan.
4. Attach the rubber cap with a screwdriver by turning it to the right until it fixes to the end of the groove.
5. Check for leakage on both side of the drain outlet.
Pour the water in direction of arrow.
Direction of the drained water
Screw hole
Screw
Drain hose
Drain pan outlet
Rubber cap
• Make sure the indoor unit is in upright position when you pour water to check for leakage.
Make sure that the water does not overflow onto the electrical part.
English-45
�� A3050 CH&XL_IB&IM_DB68-04219A_HP&CO_EN.indd 45 2014/7/10 16:50:50
advertisement
Related manuals
advertisement
Table of contents
- 4 Safety precautions
- 10 Checking before use
- 12 Checking the name of the parts
- 13 Checking the remote controller
- 15 Basic function
- 17 Adjusting the air flow direction
- 18 Using the Fast function
- 18 Using the Comfort function
- 19 mode
- 20 Setting the On/Off timer
- 21 Using the Auto Clean function
- 22 Using the Single User function
- 22 Using the Virus Doctor function
- 23 Using the Quiet function
- 23 Using the Smart A/C application
- 23 Using the Filter reset
- 24 Cleaning the air conditioner
- 27 Maintaining the air conditioner
- 28 Troubleshooting
- 30 Safety precautions
- 31 Choosing the installation location
- 34 Accessories
- 36 Fixing the installation plate
- 37 Disassembling/Assembling the Cover panel for indoor unit installation
- 39 Connecting the assembly cable
- 41 Installing and connecting the assembly pipe of the indoor unit
- 42 Evacuating the indoor unit
- 42 Cutting or extending the pipe
- 44 Installing and connecting the drain hose of the indoor unit
- 45 Changing direction of the drain hose
- 46 Installing and connecting the drain hose of the outdoor unit
- 46 Evacuating the connected pipes
- 49 Performing the gas leak tests
- 50 Fixing the indoor unit in place
- 50 Fixing the outdoor unit in place
- 51 Smart Install mode
- 53 Final check and trial operation
- 53 Pump down procedure (when removing the product)
- 54 How to connect your extended power cables