Technical data. Beckhoff EL3314-0002, EL3314-0090, EL3312, EL3318, EL3311, EL33-00 Series, EL3314-0010, EL3314
Add to My manuals204 Pages
advertisement
Product overview
2.2.2
Technical data
Technical data
Number of inputs
Connection technology
Maximum cable length to the thermocouple
Input filter limit frequency
Conversion time
EL3314-0002
4
2-wire
30 m (
)
1 kHz typ.; depending on sensor length, conversion time, sensor type approx. 1.6 s up to 5 ms, depending on configuration and filter setting, default: approx. 110 ms at 50/ 60 Hz via the E-bus typ. 200 mA
-
Power supply for electronics
Current consumption via E-bus
Distributed Clocks
Voltage measurement
Measurement range (FSV)
Measurement error @ 50 Hz and 23°C ambient temperature
Resolution
Temperature coefficient
Temperature measurement
Wiring fail indication
Temperature measurement
± 78 mV
± 25 µV (0.033% FSC)
1 µV per digit tbd
± 2.5 V tbd tbd
Resolution
Temperature coefficient
Bit width in the process data image
Configuration
Electrical isolation
Recommended operating voltage range (ground related)
Recommended signal range
(differential)
Destruction limit
(ground related)
Destruction limit
(differential)
Special features
Weight yes
Type/ measurement range
Highest temperature value represent the
FSV
(used: ± 78 mV voltage measurement range)
Typ B: +200...+1820 °C
Measurement error @ 50 Hz filter and
23°C ambient temperature
±5.0 °C
Typ E: -270...+1000°C
Typ J: -210...+1200 °C
Typ K: -270…+1372 °C
(default)
Typ L: -50...+900 °C
Typ N: -270…+1300 °C
±1.8 °C
±1.8 °C
±1.8 °C
Typ R: -50...+1768 °C
Typ S: -50...+1768 °C
Typ T: -270…+400 °C
Typ U: -50...+600 °C
Typ C: 0...+2329 °C
±1.8 °C
±2.5 °C
±4.0 °C
±4.0 °C
±1.8 °C
±1.8 °C
±3.5 °C
The given measuring error results from several factors, i.a. the measuring error of the voltage measurement specified above and the accuracy of the temperature measurement at the cold junction.
Internal: 24 bit
Temperature representation: 0.1/0.01/0.001 °C per digit, default 0.01°C tbd max. 24 byte input via TwinCAT System Manager
2,500 V functional isolation (testing voltage 7s channel/ channel and channel/ fieldbus, production test)
Temperature and voltage measurement range
Depending on the normative application environment with consideration of the above stated electrical isolation see temperature measurement in this table
2.5 kV (Testing voltage production test)
DisableWireBreak Detection, voltage measurment approx. 60 g
30 V
Note: FSV = full scale value
22 Version: 4.2
EL33xx-00x0
advertisement
Related manuals
advertisement
Table of contents
- 7 1 Foreword
- 7 Product overview Analog Thermocouple Input Terminals
- 7 Notes on the documentation
- 9 Safety instructions
- 10 Documentation issue status
- 12 Version identification of EtherCAT devices
- 16 2 Product overview
- 16 EL3311, EL3312, EL
- 16 Introduction
- 20 Technical data
- 21 Introduction
- 22 Technical data
- 23 Introduction
- 25 Technical data
- 26 Introduction
- 27 Technical data
- 28 Introduction
- 29 Technical data
- 30 TC technology basics
- 31 Use of EL33xx in the TwinCAT System Manager
- 32 Start
- 34 3 Basics communication
- 34 EtherCAT basics
- 34 EtherCAT cabling – wire-bound
- 35 General notes for setting the watchdog
- 37 EtherCAT State Machine
- 39 CoE Interface
- 44 Distributed Clock
- 45 4 Mounting and wiring
- 45 Safety instructions
- 45 Environmental conditions
- 45 Transport / storage
- 45 Control cabinet / terminal box
- 46 Instructions for ESD protection
- 46 Installation on mounting rails
- 49 Installation instructions for enhanced mechanical load capacity
- 50 Connection
- 50 Connection system
- 52 Wiring
- 53 Shielding
- 54 Positioning of passive Terminals
- 54 4.10 Installation positions 331x
- 56 4.11 Prescribed installation position EL3314-0002/ EL
- 58 4.12 LEDs
- 58 EL3311 - LEDs
- 59 EL3312 - LEDs
- 60 EL3314, EL3314-00xx - LEDs
- 63 EL3318 - LEDs
- 64 4.13 Terminal assignment
- 64 EL3311 - Connection
- 65 EL3312 - Connection
- 66 EL3314-00x0 - Connection
- 69 EL3318 - Connection
- 70 Connection instructions for earthed/potential-free thermocouples
- 71 4.14 UL notice
- 72 4.15 ATEX - Special conditions (standard temperature range)
- 73 4.16 ATEX - Special conditions (extended temperature range)
- 74 4.17 ATEX Documentation
- 75 5 Commissioning
- 75 TwinCAT Quick Start
- 77 TwinCAT
- 99 TwinCAT Development Environment
- 99 Installation of the TwinCAT real-time driver
- 105 Notes regarding ESI device description
- 109 TwinCAT ESI Updater
- 109 Distinction between Online and Offline
- 110 OFFLINE configuration creation
- 115 ONLINE configuration creation
- 123 EtherCAT subscriber configuration
- 133 General Notes - EtherCAT Slave Application
- 141 TwinSAFE SC
- 141 TwinSAFE SC - operating principle
- 141 TwinSAFE SC configuration
- 145 Process data
- 145 Sync Manager
- 146 Process data preselection (predefined PDOs)
- 148 Data processing
- 148 TwinSAFE SC process data EL
- 149 Settings
- 149 Presentation, index 0x80n
- 149 Siemens bits, index 0x80n
- 150 Underrange, Overrange
- 150 Notch filter (conversion times)
- 151 Limit 1 and Limit
- 151 Calibration
- 153 Producer Codeword
- 154 Operation with an external cold junction
- 155 Interference from equipment
- 155 Wire break detection
- 155 5.10 Object description and parameterization
- 156 Restore object
- 157 Configuration data
- 159 Profile-specific objects (0x6000-0xFFFF)
- 159 Configuration data (vendor-specific)
- 159 Input data
- 160 Output data
- 160 Information and diagnostic data
- 161 Standard objects (0x1000-0x1FFF)
- 166 5.11 Status word
- 170 5.12 Notices on analog specifications
- 170 Full scale value (FSV)
- 170 Measuring error/ measurement deviation
- 171 Temperature coefficient tK [ppm/K]
- 172 Single-ended/differential typification
- 177 Common-mode voltage and reference ground (based on differential inputs)
- 177 Dielectric strength
- 178 Temporal aspects of analog/digital conversion
- 182 6 Appendix
- 182 Sample program for individual temperature calculation in the PLC
- 185 EtherCAT AL Status Codes
- 185 Firmware Update EL/ES/EM/EPxxxx
- 186 Device description ESI file/XML
- 189 Firmware explanation
- 190 Updating controller firmware *.efw
- 191 FPGA firmware *.rbf
- 195 Simultaneous updating of several EtherCAT devices
- 196 Firmware compatibility
- 198 Restoring the delivery state
- 199 Support and Service