VAR8 / Variants - Installation Guide
• The VAR8 unit.
• A 19-inch standard rack wired and configured with V400 amplifier mainframes, and wiring for power supply, signal monitoring, CAN bus, and RS232 and RS485 cabling as appropriate.
• A small flat-bladed screwdriver.
• Large pozidrive screwdriver.
• Cable termination tools - cutters/strippers etc. to suit cable type.
The following cabling is recommended within the equipment rack. For pinout refer to Figure 1 (page
5 ), and for cabling connector refer to Section “ 2 Connections ” (page 12 ).
1. DC power supply cabling:
Standard cable rated for 3A.
Recommended type: BELDEN 8205LSHF.
Twisted pairs, individually screened.
Recommended type: BELDEN 8451 LSHF.
The rack and field cabling should be as described in the diagram shown in Figure 3 .
3. A/B audio outputs on Interface Expansion Board (EXP8):
Twisted pairs, individually screened.
Recommended type: BELDEN 8451 LSHF.
The rack and field cabling should be as described in the diagram shown in Figure 3 .
4. Audio and data network cabling (on VAR8 with Network Interface Card):
Twisted pairs with overall foil screen.
Recommended type: FS cables 2407 POFYH.
The Upstream side of the network connection is isolated RS485. To maximise the benefits of this, the rack and field cabling should be as described in the diagram shown in Figure 2 .
Overall screened.
Recommended type: BELDEN LS0H.
The rack and field cabling should be as described in the diagram shown in Figure 3 .
6. Audio outputs on RJ45 (see signals and pinout in Table 1 , page 13 ):
Cabling: overall foil screened.
Recommended type: CAT5 STP or FTP LS0H
The rack and field cabling should be as described in the diagram shown in Figure 3 .
!
!
The use of screened cables where specified is necessary for EMC compliance. Also for
EMC compliance, rack and field cabling should be according to the specified diagram.
Issue: 01 complete, approved
Page 6 of 22
VAR8 / Variants - Installation Guide
Figure 2 Network
DIN RAIL
FIELD CABLING RACK CABLING
VAR8
SCREEN
DXP
DXN
BUS1+
BUS1-
BUS2+
BUS2-
BUS3+
BUS3-
NETWORK
DOWNSTREAM
100nF 100V
(Reference: RS 211-5340)
GND
DXP
DXN
BUS1+
BUS1-
BUS2+
BUS2-
BUS3+
BUS3-
NETWORK
UPSTREAM
FIELD CABLING
DIN RAIL
RACK CABLING
Issue: 01 complete, approved
Page 7 of 22
VAR8 / Variants - Installation Guide
Figure 3 Audio I/O and Other Signal Termination
RACK
SHORT TAIL < 4cm
FIELD WIRING
SCREEN
!
EARTH TERMINAL
BONDED TO THE DIN
RAIL
SHORT TAIL < 4cm
!
DIN RAIL ELECTRONICALLY BONDED
TO RACK
SCREEN
RACK WIRING
DIN RAIL
EARTH TERMINAL
WEIDMÜLLER PART NUMBER: WPE4
SIGNAL TERMINAL
WEIDMÜLLER PART NUMBER: WDU2.5
Issue: 01 complete, approved
Page 8 of 22
advertisement
Related manuals
advertisement
Table of contents
- 5 Installation
- 6 Installation Requirements
- 6 Cabling Requirements
- 9 Recommended Installation Procedure
- 11 Link Settings for Stand-Alone, 1 or 2 Channel Only Network Operation
- 12 Connections
- 16 Product Specification
- 19 Mechanical Dimensions
- 20 Safety and Precautions
- 20 Environmental
- 20 Electrical Safety
- 20 Lithium Battery
- 20 Unpacking and Handling
- 20 Packing for Repair
- 21 Reference Documentation
- 22 Service and Warranty
- 22 Exclusions