advertisement
![Product Specification. ASL INTERCOM VAR8 | Manualzz Product Specification. ASL INTERCOM VAR8 | Manualzz](http://s2.manualzz.com/store/data/063401673_1-eb9f03a164ef2d8aa5b86904a7b421c0-360x466.png)
VAR8 / Variants - Installation Guide
General
Supply Voltage Range........................................................................................................18
− 40V DC
Current Consumption ...................................470mA @ 24V DC supply, backlight off and sounder off
580mA @ 24V DC supply, backlight on and sounder on
Auxiliary DC supply for external equipment ...................................................18 − 36V DC @ 200mA
Fault Log..............................................................................................................................200 events
Real Time Clock (RTC) ................................................................. Built-in (externally synchronisable)
Night Volume Control ................................................Daily time controlled input / Output level control
Format .....................................................................................................19-inch rack mounting frame
Colour ........................................................................................................Black with silver annotation
Audio Routing
Balanced Audio Inputs ................................................................................................ Inputs 1 to 8
1,2,3
Unbalanced Audio Input ............................................................................................................ Input 9
Number of Digital Messages (DVA) ............................................................... 2x50-second messages
2x66-second messages
Number of Concurrent Host Routes...................................................................................... 20 (max.)
Override per Output............................................................................................................... 20 (max.)
Audio Input
Sensitivity and Impedance Inputs 1 to 8 ..................................................
− 20dBu (77mV) @ Z ≥ 20k Ω
Sensitivity and Impedance Input 9 ....................................................... Suits 1–2V RMS units Z ≥ 5k Ω
Input Overload Margin.................................................................................................................. 40dB
Input Attenuator Range ....................................................................................................... 0 to –63dB
Equalisation............................................................................................................3 band plus LF Cut
Surveillance Tone.................................................................20–30Hz / Required Level 0 to –40dBFS
Audio Output
Number of Balanced Audio Outputs....................................................................................................8
Separate A and B output connections available on VAR8-NE
Level and Impedance .....................................................................................................0dBu @ 600 Ω
Graphic Equalisation ................................................... ±12dB at 125, 250, 500, 1k, 2k, 4k, 8k, 16kHz
Surveillance Tone......................................................................................................10dBu to − 30dBu
30Hz Pulsed Mode=1s on 20s off
Gain Control Range.........................................................................................................0dB to − 63dB
1 Inputs 1 and 2: Hardwire bypass Fire Microphone inputs.
Supports Fire Microphone, Zoned Fire Microphone, Paging Microphone, Single Button Microphone, or
Miscellaneous Input. Input 1 supports Network Channel.
Supports up to 30 microphone buttons configurable for zone select, DVA routing, play DVA, all-call, cancelall-DVA, or route reset.
2 Inputs 3 to 8: Supports Paging Microphone, Single Button Microphone, or Miscellaneous Input. Inputs 3 and 4 support
Network Channel.
Supports up to 20 microphone buttons configurable for zone select, play DVA, all-call, cancel-all-DVAs, or
3 route reset.
Inputs 1, 3, and 4 are used for system networking
Issue: 01 complete, approved
Page 16 of 22
VAR8 / Variants - Installation Guide
Audio General
DVA Bandwidth .............................................................................................................100Hz to 8kHz
THD Input to Output ...................................................................................................... <0.1% @1kHz
Crosstalk........................................................................................................................ >70dB @1kHz
Residual Noise ................................................................................................................... <78dBu (A)
S/N Line................................................................................................................................ >70dB (A)
Frequency Response (Input to Output)............................................................ 100Hz to 20kHz, –3dB
Audio Monitoring
SPL from Loudspeaker (Sounder Mode)..............
≥ 50dBA @ 1m from the equipment enclosure
Frequency Response (from Input through to Speaker) ............................. 200Hz to 10kHz − 3dB
Gain Range Control (Front panel rotary knob) ............................................................ 0 to –63dB
Control Ports
Parallel Control Inputs ............................................................10xopto-isolated interfaces on VAR8-N
20xopto-isolated interfaces on VAR8-NE
Built-in resistor to suit voltages of +12 to +40V
Changeover Fault Relay......................................................................................................................1
Maximum Global Fault Relay Contact Current Rating .............................................................. 500mA
Open Collector Drive (SPEAK NOW LED, ALL CALL LED, REMOTE FAULT OUTPUTS)..... 100mA
Remote I/O Units (BMB01) on RS485 Port.............................................................................. 6 (max)
Analogue inputs for external fault indication, volume control, programme selector, or ANS
Digital inputs for routing, route reset, or external fault indication
Digital output for busy indication
Max 12 Ambient Noise Sensor (ANS) per Router output
4
One Programme Selector per Router output
One Volume Control may be configured to govern the same input in respect of the same output
RS232 Port (mutually exclusive use configurable via front panel)....... Host PC for configuration only
Software download
Intellevac network on VAR8-N and VAR8-NE
VAR8 Variants
VAR8 .................................................................................................. Base Unit, standard 8x8 Router
VAR8-E................................................................................. VAR8+EXP8 Interface Expansion Board
VAR8-N ...................................................................................VAR8+ANIC8 Intellevac Network Card
VAR8-NE ...........VAR8+ANIC8 Intellevac Network Interface Card+EXP8 Interface Expansion Board
4 ANS sensors controlling the same outputs should be connected to the same BMB01 unit.
Issue: 01 complete, approved
Page 17 of 22
VAR8 / Variants - Installation Guide
Network (VAR8-N and VAR8-NE)
Network Audio Channels......................................................................................................... 1, 2 or 3
Standard .................................................................................................................................... RS485
Data Rate ............................................................................................................................38.4k baud
Distance between Nodes ................................................................................................... 1km (max.)
Network Control Response Time (FA trigger to DVA initiation) ...........................................<1 second
Fault tolerance......................................Any single open or short circuit can be detected and isolated
Dimensions and Weight
Dimensions (H x W x D) ................... 88mm (2U) x 436mm x 233mm (excl. connectors and handles)
Weight ..........................................................................................................................................4.5kg
Environmental – All Variants
Temperature (Storage and Operating).....................................................................
− 5°C up to + 50°C
Humidity Range........................................................................................0% to 93% Non-condensing
Safety and EMC
EMC.................. EN55103-1/E1, EN55103-2/E5, EN50121-4, EN50130-4, EN61000-6-3, ENV50204
Safety ..................................................................................................................................... EN60065
Issue: 01 complete, approved
Page 18 of 22
advertisement
Related manuals
advertisement
Table of contents
- 5 Installation
- 6 Installation Requirements
- 6 Cabling Requirements
- 9 Recommended Installation Procedure
- 11 Link Settings for Stand-Alone, 1 or 2 Channel Only Network Operation
- 12 Connections
- 16 Product Specification
- 19 Mechanical Dimensions
- 20 Safety and Precautions
- 20 Environmental
- 20 Electrical Safety
- 20 Lithium Battery
- 20 Unpacking and Handling
- 20 Packing for Repair
- 21 Reference Documentation
- 22 Service and Warranty
- 22 Exclusions