2 Connections
Network Interface Upstream
GND
DXP
DXN
Signal Description
GND ISO. Connection for cable screen.
EIA RS485 38400 bits per second (+).
EIA RS485 38400 bits per second (-).
BUS1+
BUS1 −
BUS2+
BUS2 −
BUS3+
BUS3 −
Audio bus Loop 1 (+20dBu Analogue audio).
Audio bus Loop 1.
Audio bus Loop 2 (+20dBu Analogue audio).
Audio bus Loop 2.
Audio bus Loop 3 (+20dBu Analogue audio).
Audio bus Loop 3.
L
Cabling connector: 9 way female clamp terminal (CAMDEN CTB92HE/9)
Network Interface Downstream
SCRN
DXP
Signal Description
Connection for cable screen.
EIA RS485 38400 bits per second (+).
DXN
BUS1+
BUS1 −
BUS2+
BUS2 −
BUS3+
BUS3 −
EIA RS485 38400 bits per second (-).
Audio bus Loop 1 (+20dBu Analogue audio).
Audio bus Loop 1.
Audio bus Loop 2 (+20dBu Analogue audio).
Audio bus Loop 2.
Audio bus Loop 3 (+20dBu Analogue audio).
Audio bus Loop 3.
L
Cabling connector: 9 way female clamp terminal (CAMDEN CTB92HE/9)
Audio Inputs 1 and 2
DXP
DXN
Signal Description
EIA RS485 19200 baud (+).
EIA RS485 19200 baud (-).
IN+
IN −
V+
PTT −
PTT+
ACO
Balanced Audio Input 0dBu Max. Sensitivity: − 20dBu Impedance: 10k Ω
As above.
+V supply (18-36V).
Press To Talk switch input (internally pulled up to +5V by 4k7 Ω ).
Press To Talk switch input (internally pulled up to +5V by 4k7 Ω ).
Open collector drive, 100mA max. All Call Only LED.
SN Open collector drive, 100mA max. Speak Now LED.
L
Cabling connector: 10 way terminal block (METWAY 120A11110)
Issue: 01 complete, approved
Page 12 of 22
VAR8 / Variants - Installation Guide
Audio Inputs 3 to 8
DXP
DXN
Signal Description
EIA RS485 19200 baud (+).
EIA RS485 19200 baud (-).
IN+
IN −
V+
V+NB
Balanced Audio Input 0dBu Max. Sensitivity: − 20dBu Impedance: 10k Ω
As above.
+V supply (18-36V).
+V supply (18-36V) (not battery backed).
L
Cabling connector: 7 way terminal block (METWAY 120A11107)
Music Input
Signal Description
IN+ Unbalanced Audio Input. Suitable for 1V to 2V RMS sources. Impedance: 5k Ω
L
Cabling connector: 2 way terminal block (METWAY 120A11102)
Standard Audio Outputs
8 7 6 5 4 3 2 1
1 2 3 4 5 6 7 8
OUT'n' −
Signal Description
OUT'n'+ Balanced Audio Output.
0dBu @ 600 Ω impedance
As above.
L
Cabling connector: RJ45
Table 1 Audio Output Signals and Pinout
Signal RJ45 Pin CAT5 Cable (EIA 568-B)
OUT4- 7 brown/white
OUT6- 3
Upper
OUT7+ 4
OUT8- 7 brown/white
Issue: 01 complete, approved
Page 13 of 22
VAR8 / Variants - Installation Guide
Enhanced A/B Audio Outputs
The enhanced outputs provide simpler connectivity than the standard outputs, but with the same functionality. Separate connections are provided to drive A & B amplifiers from each output.
OUT'n'-A+
Signal Description
A output. Balanced Audio Output, 0dBu @ 600 Ω impedance.
OUT'n'-A − As above.
OUT'n'-B+
OUT'n'-B −
B output. Balanced Audio Output, 0dBu @ 600
As above.
Ω impedance.
L
Cabling connector for outputs 1 to 4: 9 way terminal block (METWAY 120A11109)
Cabling connector for outputs 5 to 8: 8 way terminal block (METWAY 120A11108)
Control Contacts
C'n'+
Cn' −
Signal Description
Opto-isolated input + connection.
As above but –ve connection. In-built resistor to suit voltages of +12 to +40V.
L
Cabling connector: 10 way terminal block (METWAY 120A11110)
RS485 Serial Port
Signal Description
DXN EIA RS485 9600 baud.
DXP EIA RS485 9600 baud.
L
Cabling connector: 3 way terminal block (METWAY 120A11103)
CAN Bus
Signal Description
CANL Controller Area Network (L).
CANH Controller Area Network (H).
L
Cabling connector: 3 way terminal block (METWAY 120A11103)
RS232 Serial Port
Signal Description
TX
RX
RTS
CTS
EIA RS232 Transmit data (9600 baud).
EIA RS232 Receive data (9600 baud).
EIA RS232 Request to Send.
EIA RS232 Clear to Send.
CTRL EIA RS232 Data Terminal Ready.
L
Cabling connector: 2 x 3 way terminal block (METWAY 120A11103)
Fault Relay Contacts
NO
Signal Description
Volt free contact – Normally Open
NC Volt free contact – Normally Closed
L
Cabling connector: 3 way terminal block (METWAY 120A11103)
Issue: 01 complete, approved
Page 14 of 22
VAR8 / Variants - Installation Guide
Audio Monitoring Bus and Auxiliary Supply
V+
A −
Signal Description
Auxiliary supply: 18V-36V fused at 200mA
Audio Monitor Bus, –10dBu nom
L
Cabling connector: 3 way terminal block (METWAY 120A11103)
Power Supply
V+
Signal Description
+V supply (18V-40V DC fused at 2.5A)
L
Cabling connector: 4 way terminal block (METWAY 120A11104)
Issue: 01 complete, approved
Page 15 of 22
advertisement
Related manuals
advertisement
Table of contents
- 5 Installation
- 6 Installation Requirements
- 6 Cabling Requirements
- 9 Recommended Installation Procedure
- 11 Link Settings for Stand-Alone, 1 or 2 Channel Only Network Operation
- 12 Connections
- 16 Product Specification
- 19 Mechanical Dimensions
- 20 Safety and Precautions
- 20 Environmental
- 20 Electrical Safety
- 20 Lithium Battery
- 20 Unpacking and Handling
- 20 Packing for Repair
- 21 Reference Documentation
- 22 Service and Warranty
- 22 Exclusions