Mode selection. STMicroelectronics TDA7492MV
जाहिरात
जाहिरात
Applications information
5.2 Mode selection
TDA7492MV
The three operating modes of the TDA7492MV are set by the two inputs STBY (pin 20) and
MUTE (pin 21).
Standby mode: all circuits are turned off, very low current consumption.
Mute mode: inputs are connected to ground and the positive and negative PWM outputs are at 50% duty cycle.
Play mode: the amplifiers are active.
The protection functions of the TDA7492MV are realized by pulling down the voltages of the
STBY and MUTE inputs shown in
. The input current of the corresponding pins must be limited to 200 µA.
Mode Selection
L
(1)
H
(1)
H
Table 6. Mode settings
STBY
Standby
Mute
Play
Table 5: Electrical specifications on page 8
0 V
0 V
X (don’t care)
L
H
MUTE
Figure 21. Standby and mute circuits
Standby
3.3 V
Mute
3.3 V
R2
30 k
R4
30 k
C7
2.2 µF
C15
2.2 µF
STBY
TDA7492MV
MUTE
Figure 22. Turn-on/off sequence for minimizing speaker “pop”
18/28 DocID16264 Rev 3
डाउनलोड