advertisement
![3.2.5 Language. Additel 673, 686 and 673 Series | Manualzz 3.2.5 Language. Additel 673, 686 and 673 Series | Manualzz](http://s2.manualzz.com/store/data/065328882_1-1fb7a8c66fa534b8e038f07776a74eb2-360x466.png)
3.2.5
Language
The device provides a multi-language user interface. Use this menu to change from the provided languages.
After the language is selected, the device needs to be restarted for the changes to take effect.
3.2.6 Display Orientation
The direction of display is adjustable for different direction of mounting.
3.3 System Service
3.3.1 System Calibration
The device provides function of calibration. Users need to enter a password to enter the system calibration page, and the factory default password is 123456. The following information is general information of the calibration page.
3.3.1.1 General Information
On the right side of electrical calibration page, there will be following icons:
Table 19 Calibration icon description
Icon Description
Return
Electrical calibration
●
Pressure module calibration
●
Restore factory ● ●
Previous point ● ●
Next point ● ●
Barometric calibration
●
●
●
●
35
Save
Cancel
OK
Cancel zero
Calibration
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
3.3.1.2 Pressure Calibration
1. Cancel zeroing
Cancel the recorded zero data.
2. Multi-point calibration a. Connection
Connect the calibrator with external pressure source and reference pressure standard. b.
Perform calibration
◆ Click on to perform calibration.
◆ Connect the calibrator with external pressure source.
◆ After the pressure is stabilized, click on to go to next point;
◆ Adjust the gauge output value to the same as the setpoint being calibrated;
◆ If the measured value has big difference with the calibration point, there will be notice by RED;
◆ If the calibration point has big difference with the measured value, there will be a notice, but it does not influence taking effect.
36
◆ New calibration data takes effect immediately. The calibration date will be changed to the current system date. c.
Restore the factory calibration data
Click on to restore the factory calibration data.
3.3.1.3 Barometric Calibration
The calibrator provides single point or dual point calibration to the internal barometric module. Before performing the barometric calibration, remove the back cover and connect the air line to 4mm connector, as shown in the Figure 11.
Figure 11 Barometric calibration
37
1. Single point calibration
Input the external barometric standard to standard pressure value, confirm and click on SAVE to finish calibration.
2. Dual point calibration a.
Connection
Connect the calibrator with external pressure source and provide greater standard of pressure. b. Perform calibration
◆ Click on to perform calibration.
◆ Input the external pressure according to the calibrator’s notice. After the pressure is stabilized, click on to go to next point;
◆ If the measured value has a big difference with the standard value, there will be notice by RED, the result cannot be saved now;
◆ If the calibration point has a big difference with the measured value, there will be a notice, but it does not influence taking effect.
◆ New calibration data takes effect immediately. The calibration date will be changed to the current system date. c. Restore the factory calibration data
Click on to restore the factory calibration data.
3.3.1.4 Electrical Calibration (ADT673 only)
1.
Cancel zeroing
Cancel the recorded zeroing data.
2. Multi- point calibration
◆ Click on to perform calibration.
38
advertisement
Related manuals
advertisement
Table of contents
- 9 Safety Instructions
- 10 1. Introduction
- 10 1.1 Overview
- 11 Accuracy
- 16 Specification
- 19 Structure
- 21 2. Display and Operation
- 25 2.3.1 Zeroing
- 26 2.3.2 Statistics
- 26 2.3.3 Filtering
- 27 2.3.4 Unit Switch
- 27 2.3.5 Pressure Setting
- 28 2.3.6 Display Resolution Setting
- 30 2.4.1 Measuring Item Switch
- 30 2.4.2 Zeroing
- 30 2.4.3 Scaling
- 30 2.4.4 Filtering
- 31 2.4.5 Statistics
- 38 3. Setting
- 39 3.1.1 Bluetooth
- 39 3.1.2 Wireless Communication
- 40 3.1.3 Serial Communication
- 41 3.1.4 ACloud Service
- 41 3.2.1 Custom Units
- 42 3.2.2 CSV File Format
- 42 3.2.3 Date & Time
- 42 3.2.4 Sound
- 43 3.2.5 Language
- 43 3.2.6 Display Direction
- 47 3.3.2 Repair and Maintenance
- 47 3.3.3 Restore Factory Settings
- 47 3.3.4 System Update
- 48 3.4.1 Display Brightness
- 48 3.4.2 Battary Information
- 48 3.4.3 Auto Backlight Off
- 48 3.4.4 Auto Power Off After Backlight Off
- 49 3.4.5 Charge Mode
- 50 4. Task (ADT673 only)
- 58 5. Data Log
- 59 6. Data Management
- 60 7. Application
- 63 8. HART Communicator (ADT673 only)