Operating instructions
Transponder-Coded Safety Switch CTP-AR
13. Technical data
NOTICE
If a product data sheet is included with the product, the information on the data sheet applies.
13.1. Technical data for safety switch CTP-AR
Parameter min.
General
Material
- Switch head
- Switch housing
Installation position
Degree of protection with plug connector M12 with plug connector RC18
Safety class according to EN IEC 61558
Degree of contamination
Mechanical life
Ambient temperature at UB = 24 V
Actuator approach speed, max.
Actuating/extraction/retention force at 20 °C
Locking force F max
Locking force F
Zh
Weight
1)
1)
according to EN ISO 14119
Connection type (depending on version)
-20
Value typ.
Die-cast zinc
Reinforced thermoplastic
Any
IP67/IP69
IP 65
(screwed tight with the related mating connector)
III
3
1 x 10 6 operating cycles
-
20
35/30/20
F
Zh
2600
= F max
/1.3 = 2000
Approx. 0.42
2 plug connectors M12, 5 and 8-pin
1 plug connector RC18, 19-pin (as yet no UL approval)
Operating voltage UB (reverse polarity protected, regulated, residual ripple < 5%)
Current consumption I
UB
For the approval according to UL the following applies
Switching load according to UL
External fuse (operating voltage UB)
External fuse (solenoid operating voltage IMP)
Rated insulation voltage U i
Rated impulse withstand voltage U imp
Resilience to vibration
EMC protection requirements
Ready delay
Risk time for single device
Risk time delay per device
Switch-on time
Discrepancy time
Test-pulse duration
Safety outputs FO1A/FO1B
- Output voltage U
FO1A
/U
FO1B
2)
HIGH U
FO1A
/U
FO1B
LOW U
FO1A
/U
FO1B
Switching current per safety output
Utilization category acc. to EN 60947-5-2
24 ± 15% (PELV)
max.
+55
40
Operation only with UL class 2 power supply, or equivalent measures
0.25
DC 24 V, class 2
2
0.5
-
-
-
-
-
-
-
-
-
Acc. to EN 60947-5-3
Acc. to EN 60947-5-3
8
-
5
-
-
1
Semiconductor outputs, p-switching, short circuit-proof
8
50
0.5
-
260
400
10
UB - 1.5
UB
0
1 -
1
150
DC-13 24V 150 mA
Caution: outputs must be protected with a free-wheeling diode in case of inductive loads
0.5
p-switching, short circuit-proof
0.8 x UB
-
UB
50
Switching frequency
Monitoring outputs OL, OI, OD
Output voltage
Max. load
Solenoid
Solenoid operating voltage IMP (reverse polarity protected, regulated, residual ripple < 5 %)
Current consumption solenoid I
IMP
Power consumption
Duty cycle
Reliability values acc. to EN ISO 13849-1
Mission time
Monitoring of guard locking and the safety guard position
Category
Performance Level (PL)
PFH d
Control of the guard locking
Category
Performance Level (PL)
PFH d
DC 24 V +10%/-15%
400
6
100
20
4 e
4.1 x 10 -9 /h
Depends on external control
1) Only applies in combination with straight actuators.
2) Values at a switching current of 50 mA without taking into account the cable length.
Unit
°C m/min
N
N
N kg
V DC mA
V DC mA
Hz
V DC mA mA
W
% years s ms ms ms ms ms
A
A
V kV
123041-03-07/15 (translation of the original operating instructions)
31