19 Troubleshooting

The following table may help you narrow down and address minor malfunctions:

19.1 Safety notices

WARNING

► Only qualified electricians, who have been trained by the manufacturer may carry out any repairs on electrical equipment.

► Improperly performed repairs may result in personal injury or damage to the device.

19.2 Troubleshooting table

Fault

Device does not turn on

Possible Cause

Defective power cord

A complete vacuum is not being created in the bag.

The bag is not being sealed correctly

The open end of the bag is not completely inside the vacuum chamber

The bag is defective

There is residue on the welding and the seal

The sealing bar is overheating so that the bag melts

Roll / bag is not positioned correctly.

The bag does not hold the vacuum after it has been sealed

The bag is defective

To Rectify

Send device to Customer Service

Position the bag correctly

Select another bag

Clean the welding / seals and retry once they are dry

Open the cover on the unit and let it cool down for a few minutes.

Please use only specified bags and rolls

Carefully follow all the steps in

Chapter Vacuuming and sealing.

Select another bag; wrap paper around any sharp edges within the bag.

47