Cable gland sizes. Elis FLONET FH30 Series

Add to My manuals
72 Pages

advertisement

Cable gland sizes. Elis FLONET FH30 Series | Manualzz

Project design, installation and service manual

Electromagnetic flowmeter FLONET FH30xx

Page 50 of 72

ELIS PLZEŇ a. s.

Sensor for compact meter version

In compact meter version, the transmitter is attached to the meter sensor by means of a steel column with a stainless-steel flange. This flange is provided with two threaded holes to facilitate connections for potential equalising conductors.

Sensor for remote meter version

Sensor manufactured in the standard protection class IP 67 includes a terminal box. In the case of the sensor protection class IP 68, the signal cable conductors are permanently connected to the sensor terminals and the terminals inside the connection box are embedded in an insulation compound. The other end of the signal cable is provided with a connector facilitating connection to the meter transmitter.

The flowmeter component parts made of carbon steel are coated with polyurethane paint, the connection box with powder paint. The surface finish of all-stainless-steel sensor housing consists of shot blasting.

Attached to the sensor housings are sensor rating plate and an arrow indicating the positive fluid flow direction.

The connections to the sensor terminal box are described in Chapter 5 (ELECTRICAL CONNECTIONS).

10.3 Cable gland sizes

Compact meter version

Transmitter terminal box is provided with 2 glands with threaded plugs

M20x1.5

Remote meter version

Transmitter: 2 pcs of glands M20x1.5

Sensor terminal box: 1 pc of gland M20x1.5

10.4 Company seals

Electromagnetic flowmeters of the type series FLONET FH30xx are supplied calibrated, verified as to their functions and with parameters set according to the customer’s order specifications. Upon completion of all fabrication and testing procedures, the meters are provided with the manufacturer’s

(company) seals.

Company seal

Upon closing the meter transmitter housing, the front lid including a viewing window is secured against opening or removal by a self-adhesive company seal.

In the cases of compact meter version, a self-adhesive company seal is applied onto the flanges connecting the meter transmitter and sensor.

If a company seal is broken, the user will forfeit their right to warranty services, i.e. free-ofcharge meter repair during the agreed product warranty period.

Assembly seal

Following electrical connection of the meter and closing the terminal compartment on the meter transmitter, the organisation responsible for the meter installation will secure the lid position by a self-adhesive seal.

ELIS PLZE Ň a. s., Luční 425/15, 301 00 Plzeň, Czech Republic, phone.: +420 377 517 711, fax: +420 377 517 722 Es 90678K