- Home
- Domestic appliances
- Climate control
- Temperature & humidity sensors
- Elis
- FLONET FH30 Series
- User manual
advertisement
Project design, installation and service manual
Electromagnetic flowmeter FLONET FH30xx
Page 70 of 72
ELIS PLZEŇ a. s.
16 ASSOCIATED DOCUMENTS AND STANDARDS
Standards
EN ISO 6817 Flow rate measurement of conductive liquids in closed profiles – Measuring method using electromagnetic flowmeters
EN 29104 Flow rate measurement of liquids in closed profiles
EN ISO 4064-1 Water meters for cold drinking water and hot water
EN 1092-1
ASME B16.5
EN 13480
EN 61010-1
EN 60664-1
Flanges and flanged connections
Pipe flanges and flanged fittings
Metal pipes for industrial application
Electrical measuring, control and laboratory equipment; safety requirements
Low voltage equipment insulation co-ordination
Manuals
Es 90684K Communication interface RS-485 MODBUS RTU
Electromagnetic flowmeters FLONET FH30xx and FLONEX FXx11x
Es 90686K Electromagnetic flowmeters of the type series FLONEX FXx11x and FLONET
FH30xx Meter control instructions
ELIS PLZE Ň a. s., Luční 425/15, 301 00 Plzeň, Czech Republic, phone.: +420 377 517 711, fax: +420 377 517 722 Es 90678K
advertisement
Related manuals
advertisement
Table of contents
- 5 BASIC INFORMATION
- 5 Application
- 6 Meter properties and functions
- 6 Important user information
- 6 Safety instructions
- 6 Liability
- 7 Product warranty
- 7 Representations and certificates
- 8 METER IDENTIFICATION
- 8 FLONET FH30xx flowmeter type designation
- 8 Scope of delivery
- 8 Compact meter version FLONET FH30x
- 8 Remote meter version FLONET FH30x
- 9 Associated documents
- 9 Flowmeter rating plates
- 9 Main meter plate
- 9 Transmitter plate
- 10 Sensor plate
- 10 METER DESIGN AND MATERIAL VERSIONS
- 10 Compact and remote meter versions
- 12 Operating pressure of the measured fluid
- 14 Sensor dimensions
- 16 Sensor lining
- 16 Electrode materials
- 17 Sensors for flowmeters FLONET FH30xx; review of sensor design and material versions
- 18 INSTALLATION
- 18 Taking over
- 18 Meter handling
- 18 Storage
- 19 Installation conditions
- 19 General principles
- 19 Straight piping sections
- 20 Suppression of the pump effects
- 21 Suppression of the effects of closing valves
- 21 Suppression of vibration effects
- 22 Piping stacks
- 22 Sensor flooding
- 22 Free discharge points
- 23 Tightening torque
- 26 Thermal insulation
- 26 Flowmeter heating
- 50 Cable gland sizes
- 50 Company seals
- 51 Dimensions and weight
- 51 Sensor
- 51 Flanges according to EN
- 52 Flanges according to ASME B
- 53 Wafer sensor
- 54 Transmitter
- 54 Transmitter for compact meter version
- 54 – sensor protection class IP
- 55 Sensor connection box
- 56 FLOWMETER FAULTS
- 56 General rules
- 56 Spare PC boards and components
- 56 Software and simulation devices
- 57 Fault identification
- 58 Meter repair procedures
- 61 MAINTENANCE
- 61 SERVICES
- 61 WARRANTY
- 61 Warranty services
- 62 Post-warranty services
- 63 ORDER NUMBER
- 70 ASSOCIATED DOCUMENTS AND STANDARDS
- 71 ANNEXES
- 71 Representation on meter decontamination