IFM PG2734 is a versatile electronic manometer used for monitoring and controlling system pressure in industrial applications. It features two configurable outputs for switching or analog signals, allowing for flexible integration into various automation systems. The digital display provides precise pressure measurements, while the LED ring offers visual indication of pressure status. Its robust design and resistance to harsh cleaning and sterilization processes make it suitable for hygienic areas.
advertisement
![4�2 Pressure monitoring / switching function. IFM PG2734 | Manualzz 4�2 Pressure monitoring / switching function. IFM PG2734 | Manualzz](http://s1.manualzz.com/store/data/068608441_1-966be1db6a6e9b701cceee77cbde145b-360x466.png)
4.2 Pressure monitoring / switching function
OUT1 changes its switching state if it is above or below the set switching limits
(SP1, rP1)� The following switching functions can be selected:
• Hysteresis function / normally open: [OU1] = [Hno] (→ fig. 1).
• Hysteresis function / normally closed: [OU1] = [Hnc] (→ fig. 1).
First the set point (SP1) is set, then the reset point (rP1) with the requested difference�
• Window function / normally open: [OU1] = [Fno] (→ fig. 2).
• Window function / normally closed: [OU1] = [Fnc] (→ fig. 2).
The width of the window can be set by means of the difference between SP1 and rP1� SP1 = upper value, rP1 = lower value�
1 2
P = system pressure; HY = hysteresis; FE = window
4.3 Pressure monitoring / analogue function
The analogue output can be configured�
• [OU2] defines whether the set measuring range is provided as 4���20 mA
([OU2] = [I]) or as 20���4 mA ([OU2] = [InEG])�
Scaling can be set by means of the teaching process or by entering a value for the
ASP and AEP parameters�
• Teaching the analogue start point [tASP] or setting the parameter [ASP] defines at which measured value the analogue signal is 4 mA (20 mA at [InEG])�
• Teaching the analogue end point [tAEP] or setting the parameter [AEP] defines at which measured value the output signal is 20 mA (4 mA at [InEG])�
Minimum distance between [ASP] and [AEP] = 25 % of the of the final value of the measuring range�
6
advertisement
Related manuals
advertisement
Table of contents
- 3 1 Preliminary note
- 3 1�1 Symbols used
- 4 2 Safety instructions
- 5 3 Functions and features
- 5 3�1 Applications
- 5 4 Function
- 5 4�1 Process measured signals
- 6 4�2 Pressure monitoring / switching function
- 6 4�3 Pressure monitoring / analogue function
- 7 4�4 Customer-specific calibration
- 8 5 Installation
- 9 5�1 Units with G1 / Aseptoflex Vario process connection
- 11 5�2 Use in hygienic areas to 3A
- 11 5�3 Use in hygienic areas to EHEDG
- 12 5�4 Ventilation diaphragm
- 12 5�4�1 Function ventilation diaphragm
- 13 5�5 Filter cover
- 14 6 Electrical connection
- 15 7 Operating and display elements
- 16 8 Menu
- 16 8�1 Menu structure: main menu
- 17 8�2 Explanation of the main menu
- 18 8�3 Menu structure: level 2 (extended functions)
- 19 8�4 Explanation of the menu level
- 20 9 Parameter setting
- 20 9�1 General parameter setting
- 22 9�2 Configuration of the digital display (optional)
- 23 9�3 Set output signals
- 23 9�3�1 Set output functions
- 23 9�3�2 Set switching limits
- 23 9�3�3 Scale analogue value for OUT
- 24 9�4 User settings (optional)