7 Operating and display elements. IFM PG2734
Add to My manuals27 Pages
IFM PG2734 is a versatile electronic manometer used for monitoring and controlling system pressure in industrial applications. It features two configurable outputs for switching or analog signals, allowing for flexible integration into various automation systems. The digital display provides precise pressure measurements, while the LED ring offers visual indication of pressure status. Its robust design and resistance to harsh cleaning and sterilization processes make it suitable for hygienic areas.
advertisement
![7 Operating and display elements. IFM PG2734 | Manualzz 7 Operating and display elements. IFM PG2734 | Manualzz](http://s1.manualzz.com/store/data/068608441_1-966be1db6a6e9b701cceee77cbde145b-360x466.png)
7 Operating and display elements
1
2
3
4
Mode/
Enter
Set 5
6
1: Analogue display
-Display of the current system pressure in kPa and MPa�
2: LED ring
According to the setting of parameter [LED] (→ 9.2):
-Display of set point and reset point�
-Lag indicator function for maximum value or minimum value�
-Display of pulsating signals and pressure peaks�
-Trend display: rising pressure or falling pressure�
3: Indicator LEDs
-LED 1, 2 = not used�
-LED 3 = system pressure of the digital display in kPa�
-LED 4 = system pressure of the digital display in MPa�
-LED 5 = not used�
-LED 6 = system pressure in % of the scaling (range ASP to AEP) or COF value in %�
-LED 7 = not used�
-LED 8 = switching status OUT1 (lights if output 1 is switched)
4: Alphanumeric display, 4 digits
-Display of the current system pressure�
-Display of the parameters and parameter values�
5: Touch button Set*
-Setting of the parameter values (continuously by touching permanently; step by step by touching briefly several times)�
15
UK
advertisement
Related manuals
advertisement
Table of contents
- 3 1 Preliminary note
- 3 1�1 Symbols used
- 4 2 Safety instructions
- 5 3 Functions and features
- 5 3�1 Applications
- 5 4 Function
- 5 4�1 Process measured signals
- 6 4�2 Pressure monitoring / switching function
- 6 4�3 Pressure monitoring / analogue function
- 7 4�4 Customer-specific calibration
- 8 5 Installation
- 9 5�1 Units with G1 / Aseptoflex Vario process connection
- 11 5�2 Use in hygienic areas to 3A
- 11 5�3 Use in hygienic areas to EHEDG
- 12 5�4 Ventilation diaphragm
- 12 5�4�1 Function ventilation diaphragm
- 13 5�5 Filter cover
- 14 6 Electrical connection
- 15 7 Operating and display elements
- 16 8 Menu
- 16 8�1 Menu structure: main menu
- 17 8�2 Explanation of the main menu
- 18 8�3 Menu structure: level 2 (extended functions)
- 19 8�4 Explanation of the menu level
- 20 9 Parameter setting
- 20 9�1 General parameter setting
- 22 9�2 Configuration of the digital display (optional)
- 23 9�3 Set output signals
- 23 9�3�1 Set output functions
- 23 9�3�2 Set switching limits
- 23 9�3�3 Scale analogue value for OUT
- 24 9�4 User settings (optional)