IFM PG2734 is a versatile electronic manometer used for monitoring and controlling system pressure in industrial applications. It features two configurable outputs for switching or analog signals, allowing for flexible integration into various automation systems. The digital display provides precise pressure measurements, while the LED ring offers visual indication of pressure status. Its robust design and resistance to harsh cleaning and sterilization processes make it suitable for hygienic areas.
advertisement
6: Touch button Mode/Enter*
-Selection of the parameters and acknowledgement of the parameter values�
* The two touch buttons are activated simply by touching / deactivated by releasing the touch button�
The touch button must be completely covered to be activated�
Slow covering (e�g� liquid flows over the display) does not activate the touch button�
8 Menu
8.1 Menu structure: main menu
M
M
M
M
M
M
M
M
S
M
S
M
S
M
S
M
S
M
S
M
S
M
S
M
1: Change to menu level 2 (extended functions)
16
1
advertisement
Related manuals
advertisement
Table of contents
- 3 1 Preliminary note
- 3 1�1 Symbols used
- 4 2 Safety instructions
- 5 3 Functions and features
- 5 3�1 Applications
- 5 4 Function
- 5 4�1 Process measured signals
- 6 4�2 Pressure monitoring / switching function
- 6 4�3 Pressure monitoring / analogue function
- 7 4�4 Customer-specific calibration
- 8 5 Installation
- 9 5�1 Units with G1 / Aseptoflex Vario process connection
- 11 5�2 Use in hygienic areas to 3A
- 11 5�3 Use in hygienic areas to EHEDG
- 12 5�4 Ventilation diaphragm
- 12 5�4�1 Function ventilation diaphragm
- 13 5�5 Filter cover
- 14 6 Electrical connection
- 15 7 Operating and display elements
- 16 8 Menu
- 16 8�1 Menu structure: main menu
- 17 8�2 Explanation of the main menu
- 18 8�3 Menu structure: level 2 (extended functions)
- 19 8�4 Explanation of the menu level
- 20 9 Parameter setting
- 20 9�1 General parameter setting
- 22 9�2 Configuration of the digital display (optional)
- 23 9�3 Set output signals
- 23 9�3�1 Set output functions
- 23 9�3�2 Set switching limits
- 23 9�3�3 Scale analogue value for OUT
- 24 9�4 User settings (optional)