&Rn - RTS/CTS option. Schneider Electric PL7 Micro/Junior/Pro, Communication applications, Volume 2
Reklama
Reklama
Appendices
&Pn - Selection of pulse dialing close/open report
Introduction
Parameters
This command determines the close/open report used during pulse dialing. It only has an effect if the appropriate bit activating this command is set by the program
ConfigurACE.
If the command is activated, it has priority over the close/open reports defined by the
OEM parameters in ConfigurACE. The default value depends on the country. The parameter value, if valid, is written in bits 3 and 4 of S28.
The parameters are:
Code
&P0
&P1
&P2
&P3
Description
Selection of 39%-61% as close/open report at 10 pulses per second
(default value).
Selection of 33%-67% as close/open report at 10 pulses per second.
Selection of 39%-61% as close/open report at 20 pulses per second.
Selection of 33%-67% as close/open report at 20 pulses per second.
Result codes The following table lists the possible command responses.
Code
OK
ERROR
Description n = 0 to 3.
If n is not in the range 0 to 3.
168
35013154.02 07/2008