Standard profiles
Note: For each connected device, refer to the corresponding documentation for details of task status words.
Internal words for FRD and FSD profiles
The following table shows the internal words specific to FRD and FSD profiles:
Object
%MW\p.2.c\0.i.4
to
%MW\p.2.c\0.i.35
Function
Adjustment parameters
Meaning
32 specific adjustment words.
Parameters which can be accessed in read and write format via the WRITE_PARAM , READ_PARAM ,
SAVE_PARAM and RESTORE_PARAM functions.
Key
(1) p.2.c\m.i.r Address z z z z p: corresponds to the processor’s slot c: corresponds to the connection point number m: corresponds to the module position number i: corresponds to the channel number
Internal words for the FED profiles
The following table shows the internal words specific to the FED profiles:
Object
%MW\p.2.c\0.i.4
to
%MW\p.2.c\0.i.11
%MW\p.2.c\0.i.12
to
%MW\p.2.c\0.i.19
%MW\p.2.c\0.i.20
to
%MW\p.2.c\0.i.49
Function Meaning
Specific status 8 specific status words.
Parameters which can be accessed in read format via the READ_STATUS function.
Specific channel level command
8 specific command words.
Parameters which can be accessed in write format by the WRITE_CMD function.
Adjustment parameters
32 specific adjustment words.
Parameters which can be accessed in read and write format via the WRITE_PARAM , READ_PARAM ,
SAVE_PARAM and RESTORE_PARAM functions.
Key
(1) z z z z p.2.c\m.i.r Address p: corresponds to the processor’s slot c: corresponds to the connection point number m: corresponds to the module position number i: corresponds to the channel number
35013154.02 07/2208