An alarm page has the same characteristics as an application page with regard to :
- the text,
- the fields.
The additional feature of an alarm page is its event-triggered display. The control system's word bit is assigned to each alarm page. If the word bit is at state 1, the page is displayed.
Ex.
A sensor fault occurs. The bit associated with the sensor fault changes to 1 in the control system.
Sensor fault
ATTENTION PRESSURE SENSOR FAULT
CHANGE TO MANUAL
Entry in a variable field is not possible on an alarm page.
On the XBT-HM and XBT-PM, the background picture and the first line are flashing during alarm.
On the XBT-PM, the dynamic function keys can’t be used in an alarm page.
A - 16 Magelis