A III. LIST OF CONSUMABLES, ACCESSORIES AND SPARES. biosystems A15
Add to My manuals131 Pages
biosystems A15 is a fully automated clinical chemistry analyzer with a throughput of up to 150 tests per hour. The analyzer is designed to perform a wide range of clinical chemistry assays, including routine chemistries, immunoassays, and specialized tests. The A15 is a compact and easy-to-use analyzer, making it ideal for small to medium-sized laboratories. With its advanced features and capabilities, the A15 can help you improve your laboratory's efficiency and productivity.
advertisement
Service manual
A III. LIST OF CONSUMABLES, ACCESSORIES AND
SPARES
If any of the components of the analyzer deteriorate of if any of the perishable materials are required, always use original BioSystems material. The following table shows lists of components that may be required. To purchase said components, please contact your usual distributor and order each element using its corresponding code. This will simplify work and minimise errors.
List of user spares, perishable materials and accessories.
CODE DESCRIPTION (Ordered by code)
CA10455 European network cable
CA10456 American network cable
FI10466 Serial channel cable for connection to PC
AC10770 Sample wells (1000),Paediatric reaction wells
AC11485 Reaction rotor (10 units)
AC11486 Reactions rotor fastening screw
FI11490
FI11491
BO1149
BO1149
FI11498
535 nm filter unit
560 nm filter unit
350 ml bottle with top (10 units)
420 ml bottle with top (10 units)
Covered filter unit
BO11524 Bottle of concentrated system liquid (1L)
FI11563
FI11564
FI11565
FI11566
340 nm filter unit
405 nm filter unit
505 nm filter unit
600 nm filter unit
FI11567
FI11568
635 nm filter unit
670 nm filter unit
AC12222 Metal rod for cleaning the needle
AC12223 2 mm Allen key
BO13146 Concentrated washing solution (100mL)
AC13188 User programme CD
BO13189 System liquid container with top
FI13190 System liquid container filters
BO13191 Washing solution container with top
BO13192 Waste container with lid and fitting
AC13193 Detachable needle
FU13194 Set of 2 A (F) fuses
LA13195 6 V/10 W halogen lamp
ZO13196 Lamp holder fastening system
AC13197 Reactions rotor cover
AC13198 Operating arm fastening for transport
(screw and foam)
AC13199 Height-adjustable leg
AC13200 Filter wheel cover
AC14549 Reagent rack
AC14550 Tube rack
AC14554 Tubes adapter (80 units)
CODE DESCRIPTION (Ordered by description)
AC12223 2 mm Allen key
BO11494 20 ml bottle with top (10 units)
FI11563
FI11564
340 nm filter unit
405 nm filter unit
BO11493 50 ml bottle with top (10 units)
FI11565
FI11490
FI11491
LA13195
505 nm filter unit
535 nm filter unit
560 nm filter unit
6 V/10 W halogen lamp
FI11566
FI11567
600 nm filter unit
635 nm filter unit
FI11568 670 nm filter unit
CA10456 American network cable
BO11524 Bottle of concentrated system liquid (1L)
BO13146 Concentrated washing solution (100mL)
FI11498 Covered filter unit
AC13193 Detachable needle
CA10455 European network cable
AC13200 Filter drum cover
AC13199 Height-adjustable leg
ZO13196 Lamp holder fastening system
AC12222 Metal rod for cleaning the needle
AC13198 Operating arm fastening for transport
(screw and foam)
Reaction rotor (10 units) AC11485
AC13197 Reactions rotor cover
AC11486 Reactions rotor fastening screw
AC10770 Sample wells (1000), Paediatric reaction
FI10466 wells
Serial channel cable for connection to PC
FU13194 Set of 2 A (F) fuses
FI13190 System liquid container filters
BO13189 System liquid container with top
AC14549 Reagent rack
AC14554 Tubes adapter (80 units)
AC14550 Tube rack
AC13188 User programme CD
BO13191 Washing solution container with top
BO13192 Waste container with lid and fitting
126
CODE
CA13308
AC13361
AC13362
MO13363
ME13364
AC13365
TU13366
ME13367
TU13368
AC13369
AC13370
AC13371
MO13372
AC13373
ZO13374
AC13375
MO13376
ME13377
VA10355
ZO10407
IN11557
FO11570
AC11860
AC13350
MO13351
ME13352
MO13353
MO13354
ME13355
AC13356
MO13357
MO13358
ME13359
AC13360
CA13378
CA13379
PC13380
PC13381
PC13382
PC13383
PC13384
PC13385
PC13386
PC13387
CE13388
TR13389
CA13393
CA13394
CA13395
CA13396
CA13397
List of spares exclusive to the technical support service.
DESCRIPTION (Ordered by code)
CD-ROM with Service programme and Service manual
Mains connector
Fuse holder
Mains switch
Set of five photosensors
Temperature adjustment tool
Full operating arm
X guide motor
Y carriage belt
Y guidemotor
Z guide motor
Spring set
Full thermostated needle set
Peltier fan
A15 fan
Full dispensing pump
Thermostated needle fastening nut
Dispensing pump seal
Dispensing pump fluid chamber
Dispensing pump motor
Electrovalve
Arm hose
Container tube unit
Waste pump
PVC waste tube
Waste container nut and cap
Full reactions rotor
Rotor temperature sensor
Rotor motor
Rotor cover sensor
Lamp holder
Filter wheel body
Filter wheel motor
Hydro-pneumatic cylinder of the cover hinge
Upper cover of needle set
Bottom cover of needle set
Microprocessor board
Photometric system board
Front indicator
Power supply board
Communications board
XYZ interconnection board
Rotor interconnection board
Pumps interconnection board
Peltier cell
Main power supply
Base cover
Upper cover
Front al cover
Spring protection cover
Instrument cover
FO11570
CA13396
ME13355
AC11860
AC13360
CA13394
CA13378
AC13369
ME13367
MO13351
PC13385
ME13352
MO13353
MO13354
CA13397
ZO13374
TR13389
VA10355
IN11557
PC13380
MO13357
CE13388
PC13381
PC13383
PC13387
TU13368
AC13373
PC13386
MO13372
AC13371
CA13308
CODE
MO13358
AC13365
CA13393
CA13379
PC13384
TU13366
AC13362
MO13363
AC13361
ME13364
AC13375
MO13376
PC13382
CA13395
AC13356
ME13359
AC13350
AC13370
ZO10407
ME13377
DESCRIPTION (Ordered by description)
A15 fan
Arm hose
Base cover
Bottom cover of needle set
Communications board
Container tube unit
Dispensing pump fluid chamber
Dispensing pump motor
Dispensing pump seal
Electrovalve
Filter wheel body
Filter wheel motor
Front indicator
Front al cover
Full thermostated needle set
Full dispensing pump
Full operating arm
Full reactions rotor
Fuse holder
Hydro-pneumatic cylinder of the cover hinge
Instrument cover
Lamp holder
Main power supply
Mains connector
Mains switch
Microprocessor board
Peltier fan
Peltier cell
Photometric system board
Power supply board
Pumps interconnection board
PVC waste tube
Rotor cover sensor
Rotor interconnection board
Rotor motor
Rotor temperature sensor
CD-ROM with Service programme and
Service manual
Set of five photosensors
Spring protection cover
Spring set
Temperature adjustment tool
Thermostated needle fastening nut
Upper cover
Upper cover of needle set
Waste container nut and cap
Waste pump
X guide motor
XYZ interconnection board
Y carriage belt
Y guidemotor
Z guide motor
127
advertisement
Key Features
- Throughput of up to 150 tests per hour
- Performs a wide range of clinical chemistry assays
- Compact and easy-to-use
- Advanced features and capabilities
Related manuals
Frequently Answers and Questions
What is the throughput of the biosystems A15?
What types of assays can the biosystems A15 perform?
Is the biosystems A15 easy to use?
advertisement
Table of contents
- 8 1. INTRODUCTION
- 8 1.1. GENERAL DESCRIPTION OF THE ANALYZER
- 9 1.1.1. Operating arm
- 9 1.1.2. Dispensing system
- 10 1.1.3. Reactions rotor and reading
- 11 1.1.4. Electronic system
- 11 1.1.5. Application program
- 11 1.2. FUNCTIONING OF THE ANALYSER
- 12 1.3. TRANSPORT AND RESHIPMENT OF THE ANALYZER
- 14 2. MECHANICAL ELEMENTS
- 14 2.1. Instrument breakdown
- 14 2.2. Description of the mechanical elements
- 14 2.2.1. Operating arm
- 15 2.2.1.1. X Guide
- 16 2.2.1.2. X Carriage
- 16 2.2.1.3. Y Carriage
- 18 2.2.1.4. Needle unit
- 19 2.2.2. Dispensing system
- 19 2.2.2.1. Thermostated probe
- 19 2.2.2.2. Dispensing pump
- 21 2.2.2.3. Tubes and containers
- 22 2.2.2.4. Container level control sensors
- 23 2.2.2.5. Racks tray with integrated washing station
- 23 2.2.2.6. Washing pumps
- 24 2.2.3. Reaction rotor with integrated optical system
- 24 2.2.3.1. Thermostated rotor and photometric system
- 26 2.2.3.2. Lighting system
- 27 2.2.4. Electronics cover
- 28 2.2.5. Main cover hinges
- 29 2.2.6. Base
- 30 2.2.7. Casings
- 31 3. Electronic system
- 31 3.1 CPU Board (CIIM00026)
- 36 3.2 Power Supply Board (CIIM00015)
- 38 3.3 Needle Board (CIIM00017)
- 40 3.4 Photometry Board (CIIM00027)
- 41 3.5 XYZ Interconnection Board (CIIM00018)
- 42 3.6 Communications Board (CIIM00036)
- 43 3.7 Rotor interconnection board (CIIM00029)
- 45 3.9 Pump interconnection board (CIIM00028)
- 47 3.10 Component relation
- 47 3.11 Auxiliar channel information
- 51 3.12 Interconnection between boards
- 57 3.13 Schematic liquid circuit
- 58 4. SERVICE PROGRAM
- 58 4.1 Initialising the analyser
- 60 4.2. ADJUSTMENTS
- 60 4.2.1. Adjustment of the needle thermostatation system
- 61 4.2.2. Adjustment of the rotor thermostation system
- 62 4.2.3. Adjustment of the positioning of the operating arm
- 62 4.2.3.1 Adjustment of X, Y and Z position for reagent and pediatric racks
- 65 4.2.4. Adjustment of the positioning of the rotor
- 65 4.2.4.1. Centering of the rotor with regard to the dispensing point
- 65 4.2.4.2. Centering of the rotor with regard to the optical system
- 66 4.2.5 . Adjustment of the positioning of the filter wheel
- 67 4.2.6. Adjustment of the level control scales
- 68 4.2.7. Adjustment of the level detection sensitivity
- 68 4.3. TESTS
- 68 4.3.1. Motor tests
- 69 4.3.1.1. Initialization test
- 69 4.3.1.2. Movement test
- 70 4.3.1.3. Loss step test
- 70 4.3.1.4. Stress mode test
- 70 4.3.1.5. Z axis secu ri ty systems test
- 71 4.3.1.6 Maximum Z verification test
- 71 4.3.2. Diaphragm pumps and electrovalves test
- 72 4.3.2.1. Functioning test
- 72 4.3.2.2. Stress mode test
- 72 4.3.3. Needle self-centering system test
- 72 4.3.4. Needle level detection system test
- 73 4.3.5. Needle thermostatation system test
- 74 4.3.6. Needle rotor thermostatation system test
- 74 4.3.7. Photometry tests
- 74 4.3.7.1. Base line and integration times
- 76 4.3.7.2. Darkness counts
- 76 4.3.7.3. Repeatability without moving the filter wheel
- 77 4.3.7.4. Stability
- 77 4.3.7.5. Repeatability moving filter wheel
- 78 4.3.7.6. Absorbance measurement
- 78 4.3.7.7. Reactions rotor check
- 79 4.3.8. Level control scales test
- 79 4.3.9. Covers detection test
- 80 4.3.10. PC-Analyzer communications channel test
- 80 4.3.11. Global stress mode of the analyzer
- 81 4.3.12. Photometry tool
- 82 4.4. UTILITIES
- 82 4.4.1. Disassembly of the dispensing needle
- 83 4.4.2. Fluid system supply
- 84 4.4.3. Cleaning of the dispensing system
- 84 4.4.4. Changing the lamp
- 85 4.4.5. Configuration of the filter wheel
- 85 4.4.6. Demonstration mode
- 86 4.4.7 Read/load adjustments and cycles
- 87 4.4.8 Change the rotor type
- 88 4.5. REGISTER
- 88 4.5.1. Introducing the analyzer serial number
- 89 4.5.2. Service Reports
- 89 4.5.3. Language change
- 90 4.5.4. Users
- 90 4.6. MONITOR
- 91 4.7 User’s program
- 91 4.7.1 Configuration of the level of access to the analyser
- 92 4.7.2 Reagent Consumption
- 94 5. MAINTENANCE AND CLEANING
- 94 5.1. MAINTENANCE OPERATIONS
- 94 5.1.1. Housings and covers
- 94 5.1.1.1. Removing the needle unit casing
- 94 5.1.1.2. Removing the front housing
- 95 5.1.1.3. Removing the main cover
- 96 5.1.1.4. Removing the upper casing
- 98 5.1.1.5. Removing the spring protector
- 98 5.1.2. Operating arm
- 98 5.1.2.1. Fully removing the operating arm
- 99 5.1.2.2. Changing the arm hose
- 100 5.1.2.3. Changing the X motor
- 102 5.1.2.4. Changing the Y motor
- 102 5.1.2.5. Changing the Z motor
- 103 5.1.2.6. Changing the Y motor belt
- 103 5.1.2.7. Changing the spring
- 104 5.1.3. Dispensing system
- 104 5.1.3.1. Changing the thermostated pipe
- 105 5.1.3.2. Changing the dispensing pump seal
- 106 5.1.3.3. Changing the dispensing pump motor
- 107 5.1.3.4. Changing the dispensing electrovalve
- 107 5.1.3.5. Changing the container tube unit
- 107 5.1.3.6. Changing the distilled water container filters
- 108 5.1.4. Reactions rotor and reading
- 108 5.1.4.1. Changing the rotor temperature probe
- 109 5.1.4.2. Fully removing the rotor
- 109 5.1.4.3. Changing the rotor Peltier cells
- 110 5.1.4.4. Changing the rotor cover detector
- 110 5.1.4.5. Changing the rotor start photosensor
- 111 5.1.4.6. Changing the rotor motor
- 112 5.1.4.8. Changing the lamp
- 113 5.1.4.9. Changing an optical filter
- 113 5.1.4.10. Configuration of the filter wheel
- 113 5.1.4.11. Changing the filter wheel start photosensor
- 114 5.1.4.12. Changing the filter wheel motor
- 114 5.1.5. Electronic Systems
- 114 5.1.5.1. Changing the X, Y and encoder start photosensor
- 115 5.1.5.2. Changing the microprocessor board
- 115 5.1.5.3. Changing the power supply board
- 116 5.1.5.4. Changing the main power supply source
- 116 5.1.5.5. Changing the photometric system board
- 117 5.1.5.6. Changing the front indicator
- 118 5.1.5.7. Changing the firmware program
- 118 5.2. RECOMMENDED PREVENTIVE MAINTENANCE
- 119 5.3. CARE AND CLEANING
- 119 5.3.1. General care of the analyzer
- 119 5.3.2. Cleaning the optical system
- 120 5.3.3. Cleaning the dispensing system
- 120 5.3.4. General cleaning of the interior of the apparatus
- 121 A I. TECHNICAL SPECIFICATIONS
- 125 A II. ADJUSTMENT MARGINS TABLES
- 126 A III. LIST OF CONSUMABLES, ACCESSORIES AND SPARES
- 128 A IV. LIST OF REQUIRED TOOLS
- 128 A V. SOFTWARE VERSIONS