When the counter is incremented from 0 to 1, the "When Unit On" macro will now execute. This will allow you to execute a command when the Flag is incremented (counting up) from zero.
The Set command is used to set the counter to a value from 0 to 255. No macros are executed when the counter is set to zero or when the counter is changed from zero using the set command. This allows a counter to be reset without executing macros or programs associated with the counter counting to zero. Turn the Flag On or Off to have the associated macro execute. When the
Flag is turned Off, its value is set to zero (0). When the Flag is turned On, its value is set to one (1). The counter is considered
On for program conditions if it is nonzero (1-255).
Flags can be turned Off, On, Decremented (DEC), Incremented (INC), Set, and Timed ON/OFF.
Controlling Outputs
The Omni IIe has eight outputs that can be used to switch relays. Outputs 1-8 are controlled as Unit Numbers 65-72, respectively.
If the Interior Horn is configured as a "General Purpose" output, Unit Number 73 is used to control the output. If the Exterior
Horn is configured as a "General Purpose" output, Unit Number 74 is used to control the output. In this configuration, Unit
Numbers 73 and 74 should not be used as "Flags".
These 12 VDC voltage outputs are connected directly to the Omni IIe and not through a module. If you have something connected to these outputs, such as a sprinkler system, your dealer will explain its operation.
Outputs cannot be brightened or dimmed and are not affected by All ON or All Off commands.
All On / Off
The All On/Off menu is used to turn all unit numbers in the specified House Codes on and off.
Note: UPB, CentraLite, and RadioRA devices are not affected by the Omni IIe “All On” or “All Off” command. To achieve this functionality, we suggest the following:
UPB: Program a Link into each device that will respond to an Omni IIe “All On” and “All Off” command program. For example:
In each UPB switch that will respond to “All Off” and “All On”, program a Link (in this example, Link 50 is used) that will go to 100% when activated (turned on). Then write the following programs in the Omni IIe controller:
WHEN ALL ON: LINK 50 ON
WHEN ALL OFF: LINK 50 OFF
CentraLite: Program the “All On” and “All Off” macro to execute an All On Scene and an All Off Scene on the
CentraLite.
RadioRA: Program the “All On” and “All Off” macro to execute Phantom Button 16 (All On) and Phantom button 17 (All Off).
For example:
WHEN ALL ON: PHANTOM BUTTON 16 ON
WHEN ALL OFF: PHANTOM BUTTON 17 ON
This All On/Off menu is also used to control Leviton Scenes, RadioRA Phantom Buttons, UPB Links, and CentraLite Scenes.
From the top-level display or from the main menu, press the 4 (ALL) key on the console keypad.
ALL
0=OFF 3=LINK
↓
ALL
4=PHANTOM 5=CENLIT
↑
Page 26
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 9 Underwriter's Laboratories (UL) Listing
- 10 Console Operation
- 11 Normal Top-Level Display
- 11 Display Menus
- 12 Main Menu
- 12 Error Beeps
- 12 Trouble Beeps
- 13 Confirmation Beep
- 13 Cancel
- 13 Time Out
- 13 Areas
- 13 Omni IIe Maintenance
- 14 Disarming the Security System and Silencing Alarms
- 14 Arming the Security System
- 15 Using Shortcut Keys
- 15 Quick Arm
- 16 What Happens When You Arm the Security System
- 16 Exit Error
- 17 Bypassing Zones
- 17 Auto-Bypass
- 17 Restoring Zones
- 18 What To Do When You Come Home
- 18 What Happens When the Alarm is Activated
- 18 Burglar Alarm Activated
- 19 Fire Alarm Activated
- 19 Gas Alarm Activated
- 19 Emergency Keys
- 20 Police Emergency
- 20 Fire Emergency
- 20 Auxiliary Emergency
- 20 Duress Code Entered or Duress Alarm Activated
- 20 Alarm Reset
- 20 Alarm Cancel
- 21 Trouble Indications
- 21 Codes
- 21 Master Code
- 22 Manager Code
- 22 User Code
- 22 Duress Code
- 22 Panic Switches
- 22 Area Arming
- 23 GOTO Area
- 24 Testing Your System
- 25 Control Commands
- 25 About UPB
- 26 HAI Lighting Control (HLC) Format
- 26 About Rooms
- 26 About Room Controllers
- 26 Room Controller LED Indicators
- 27 About House Controllers
- 27 About CentraLite
- 27 About Lutron RadioRA
- 28 About ALC
- 28 ALC Module Types
- 28 About X
- 28 House Codes
- 29 Unit Numbers
- 29 Scrolling Through Names
- 29 Controlling Units
- 29 Controlling a Room of HLC Lighting
- 30 Configuring Lighting Scenes in an HLC Room
- 30 Controlling Individual Lighting Loads in an HLC Room or UPB Units
- 31 Controlling CentraLite Units
- 31 Controlling RadioRA Units
- 31 Controlling ALC or X-10 Units
- 32 Ramp Command (ALC)
- 32 Controlling Compose Units
- 33 Scene Command (Compose)
- 33 Timed Commands
- 33 Status of a Unit
- 33 Internal Flags
- 34 Controlling Outputs
- 34 All On / Off
- 35 All Lights On
- 35 All Off
- 35 Leviton Scene Control
- 35 Scene
- 36 Scene Commands
- 36 Scene Set Command
- 36 Scene On Command
- 36 Scene Off Command
- 36 UPB Links
- 37 Activating and Deactivating Links
- 37 Setting a Link (Lighting Scenes)
- 37 Executing Phantom Buttons
- 37 Executing CentraLite Scenes
- 38 Buttons
- 38 Temperature Control
- 39 HAI RC-Series Thermostats
- 40 Programmable Energy Saver Modules (PESMs)
- 42 Freeze Alarms
- 42 Indoor and Outdoor Temperature
- 43 Temperature Control of Appliances
- 43 Temperature Alarms
- 43 Humidity
- 44 Status
- 44 Configuring HLC Devices
- 44 Configuring HLC Devices using an Omni Console
- 45 Configuring HLC Devices using an OmniTouch Touchscreen
- 45 Setup Mode for HLC Devices
- 47 Event Log
- 48 Show Events
- 48 Messages
- 48 Show Message
- 49 Log Message
- 49 Clear Message
- 49 Say Message
- 49 Phone Message
- 49 Send Message (Pro-Link)
- 51 Telephone Interface
- 51 In-House Phones
- 51 Remote Phones
- 52 Phone Access Denied - Remote Lockout
- 52 Alternate Method
- 52 Main Menu
- 53 1 - Control
- 53 2 - Security
- 53 GOTO Area
- 53 3 - Button
- 53 4 - All
- 53 5 - Temperature
- 54 6 - Status
- 54 7 - Events
- 55 8 - Phone
- 55 9 - Good-Bye
- 55 Panic Button over the Phone (# # # # # #)
- 56 Emergency Dial-Out
- 56 Digital Dialer
- 56 Voice Dialer
- 56 How the Omni IIe Voice Dialer Works
- 56 What the Omni IIe Voice Dialer Does
- 57 What You Hear - If Your Omni IIe Calls You
- 57 Entering the Code
- 58 Built-In Ethernet Port
- 58 Controller IP Address, Port Number, and Encryption Key
- 58 Omni IIe Ethernet Connections
- 58 Connecting to Network via PC Access
- 59 Dynamic DNS
- 61 Configuration and Advanced Control Programming (ACP)
- 61 Set Up Codes
- 61 Authority Level
- 61 AUTHORITY
- 61 1 = Master
- 61 2 = Manager
- 61 3 = User
- 62 Access Areas
- 62 Duress Code
- 62 Set Up Time
- 63 Advanced Control Programming (ACP)
- 64 1 = Add Programs
- 64 2 = Show Programs
- 65 3 = Delete All Programs
- 65 Edit Programs
- 66 Edit Programs When
- 66 Times Programs
- 67 Button and Event Programs
- 67 Control Unit / Switch Press Event Buttons
- 68 Security Mode Event Buttons
- 69 Zone Event Buttons
- 69 All On/Off Event Buttons
- 70 UPB Link Event Buttons
- 70 Alarm Event Buttons
- 70 X-10 Event Buttons
- 71 Miscellaneous Event Buttons
- 71 Message Event Buttons (Pro-Link)
- 72 Switch Press Event Buttons (CentraLite)
- 72 Edit Program Command
- 72 Program Control Commands
- 73 Unit Toggle Command
- 73 Program Security Commands
- 74 Program Button Commands
- 74 Program All On / All Off Commands
- 74 Program Video Commands
- 74 Program Temperature Commands
- 74 Program Energy Cost
- 75 Program Message Commands
- 75 Edit Program Condition
- 75 Program Control Conditions
- 76 Program Security Mode Conditions
- 76 Program Zone Conditions
- 76 Program Time Clock Conditions
- 76 Program Other Conditions
- 77 Set Up Dial
- 77 Telephone Access
- 77 Answer Outside Call
- 78 Remote Commands
- 78 Rings Before Answer
- 78 Dial Type
- 78 My Phone Number
- 78 Dial Out Number
- 79 Dial Out Numbers
- 79 Dial Order
- 79 Set Up Arming
- 79 Entry Delay
- 80 Exit Delay
- 80 Exit Time Restart
- 80 Unvacated Premises
- 80 Entry/Exit Chime
- 80 Perimeter Chime
- 80 Enable Quick Arm
- 81 Enable Auto Bypass
- 81 All On For Alarm
- 81 Beep On Trouble
- 81 Set up Miscellaneous
- 81 High Security Mode
- 81 Announce Alarms
- 82 Enable Freeze Alarm
- 82 Flash For Alarm
- 82 Console 1-8 Audible Exit Delay
- 82 House Codes 1-4 Format
- 82 House Codes 1-4 All Off
- 83 Time Clocks
- 84 Latitude, Longitude, and Time Zone
- 85 Daylight Savings
- 85 Controller IP Address
- 86 Controller Port Number
- 86 Encryption Key
- 87 Set Up Names
- 87 Set Up Voice
- 88 Set Up Address
- 89 FIRE ESCAPE PLANNING
- 93 INSTRUCTIONS TO CALLED PARTY