- No category
advertisement
Set Up Names
The system can be set up to display descriptive names such as "FRONT DOOR", "JOHN'S BEDROOM", or "PORCH LIGHT" for zones, units, buttons, codes, temperatures, areas, and messages. These names are displayed instead of the unit, zone, button, code, temperature, area, and message number that is normally displayed. Zone and Message names may be up to 15 characters long. Each of the other names may be up to 12 characters long.
To enter the Set Up Names menu, from the Setup menu, press the 7 (NAME) key.
SET
1=CTRL 2=ZONE 3=BTTN
↓
4=CODE 5=TEMP 6=AREA
8=MSG
↑
The 6 (AREA) choice will only be displayed if area arming is being used.
Select the item that you would like to name by pressing one of the keys (1-6, and 8). The current name for the first item (unit, zone, button, code, temperature, area, and message) is then displayed. Use the arrow keys to scroll through the list of names.
To enter a name, enter the two digit code shown in Appendix B for each character in the name, then press the ' # ' key. Use the up arrow key to delete the most recently entered character.
ZONE 1:
00-95
↓
ZONE 1: FRONT DOOR------
00-95
↑
=DEL
ZONE 1: FRONT DOOR
00-95
↓
Set Up Voice
The Omni IIe can be set up to speak descriptive names such as "FRONT DOOR" for control zones, units, buttons, codes, temperatures, areas, and messages. These names will be spoken over the telephone along with the item number that is normally spoken. Voice descriptions for messages can be spoken over a speaker when used with the HAI Two-Way Audio Module.
To enter the Set Up Voice menu, from the Setup menu, press the 8 (VOICE) key.
SET UP VOICE
1=CTRL 2=ZONE 3=BTTN
↓
4=CODE 5=TEMP 6=AREA
8=MSG
↑
Select the item that you would like to give a voice description. Use the arrow keys to scroll through the list of names.
To enter a voice description, enter the code shown next to the voice description in Appendix C for each description (word or group of words), then press the ' # ' key. After you have entered the complete description for each item (unit, zone, button, code, temperature, area, and message), press the ' # ' key twice. You may enter up to six (6) descriptions (word or group of words) for each unit, zone, button, code, temperature, area, and message.
UNIT
↓
UNIT
144 109
↓
When Unit 1 is spoken over the phone, the Omni IIe will say, "UNIT 1 - PORCH LIGHT".
Page 79
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 9 Underwriter's Laboratories (UL) Listing
- 10 Console Operation
- 11 Normal Top-Level Display
- 11 Display Menus
- 12 Main Menu
- 12 Error Beeps
- 12 Trouble Beeps
- 13 Confirmation Beep
- 13 Cancel
- 13 Time Out
- 13 Areas
- 13 Omni IIe Maintenance
- 14 Disarming the Security System and Silencing Alarms
- 14 Arming the Security System
- 15 Using Shortcut Keys
- 15 Quick Arm
- 16 What Happens When You Arm the Security System
- 16 Exit Error
- 17 Bypassing Zones
- 17 Auto-Bypass
- 17 Restoring Zones
- 18 What To Do When You Come Home
- 18 What Happens When the Alarm is Activated
- 18 Burglar Alarm Activated
- 19 Fire Alarm Activated
- 19 Gas Alarm Activated
- 19 Emergency Keys
- 20 Police Emergency
- 20 Fire Emergency
- 20 Auxiliary Emergency
- 20 Duress Code Entered or Duress Alarm Activated
- 20 Alarm Reset
- 20 Alarm Cancel
- 21 Trouble Indications
- 21 Codes
- 21 Master Code
- 22 Manager Code
- 22 User Code
- 22 Duress Code
- 22 Panic Switches
- 22 Area Arming
- 23 GOTO Area
- 24 Testing Your System
- 25 Control Commands
- 25 About UPB
- 26 HAI Lighting Control (HLC) Format
- 26 About Rooms
- 26 About Room Controllers
- 26 Room Controller LED Indicators
- 27 About House Controllers
- 27 About CentraLite
- 27 About Lutron RadioRA
- 28 About ALC
- 28 ALC Module Types
- 28 About X
- 28 House Codes
- 29 Unit Numbers
- 29 Scrolling Through Names
- 29 Controlling Units
- 29 Controlling a Room of HLC Lighting
- 30 Configuring Lighting Scenes in an HLC Room
- 30 Controlling Individual Lighting Loads in an HLC Room or UPB Units
- 31 Controlling CentraLite Units
- 31 Controlling RadioRA Units
- 31 Controlling ALC or X-10 Units
- 32 Ramp Command (ALC)
- 32 Controlling Compose Units
- 33 Scene Command (Compose)
- 33 Timed Commands
- 33 Status of a Unit
- 33 Internal Flags
- 34 Controlling Outputs
- 34 All On / Off
- 35 All Lights On
- 35 All Off
- 35 Leviton Scene Control
- 35 Scene
- 36 Scene Commands
- 36 Scene Set Command
- 36 Scene On Command
- 36 Scene Off Command
- 36 UPB Links
- 37 Activating and Deactivating Links
- 37 Setting a Link (Lighting Scenes)
- 37 Executing Phantom Buttons
- 37 Executing CentraLite Scenes
- 38 Buttons
- 38 Temperature Control
- 39 HAI RC-Series Thermostats
- 40 Programmable Energy Saver Modules (PESMs)
- 42 Freeze Alarms
- 42 Indoor and Outdoor Temperature
- 43 Temperature Control of Appliances
- 43 Temperature Alarms
- 43 Humidity
- 44 Status
- 44 Configuring HLC Devices
- 44 Configuring HLC Devices using an Omni Console
- 45 Configuring HLC Devices using an OmniTouch Touchscreen
- 45 Setup Mode for HLC Devices
- 47 Event Log
- 48 Show Events
- 48 Messages
- 48 Show Message
- 49 Log Message
- 49 Clear Message
- 49 Say Message
- 49 Phone Message
- 49 Send Message (Pro-Link)
- 51 Telephone Interface
- 51 In-House Phones
- 51 Remote Phones
- 52 Phone Access Denied - Remote Lockout
- 52 Alternate Method
- 52 Main Menu
- 53 1 - Control
- 53 2 - Security
- 53 GOTO Area
- 53 3 - Button
- 53 4 - All
- 53 5 - Temperature
- 54 6 - Status
- 54 7 - Events
- 55 8 - Phone
- 55 9 - Good-Bye
- 55 Panic Button over the Phone (# # # # # #)
- 56 Emergency Dial-Out
- 56 Digital Dialer
- 56 Voice Dialer
- 56 How the Omni IIe Voice Dialer Works
- 56 What the Omni IIe Voice Dialer Does
- 57 What You Hear - If Your Omni IIe Calls You
- 57 Entering the Code
- 58 Built-In Ethernet Port
- 58 Controller IP Address, Port Number, and Encryption Key
- 58 Omni IIe Ethernet Connections
- 58 Connecting to Network via PC Access
- 59 Dynamic DNS
- 61 Configuration and Advanced Control Programming (ACP)
- 61 Set Up Codes
- 61 Authority Level
- 61 AUTHORITY
- 61 1 = Master
- 61 2 = Manager
- 61 3 = User
- 62 Access Areas
- 62 Duress Code
- 62 Set Up Time
- 63 Advanced Control Programming (ACP)
- 64 1 = Add Programs
- 64 2 = Show Programs
- 65 3 = Delete All Programs
- 65 Edit Programs
- 66 Edit Programs When
- 66 Times Programs
- 67 Button and Event Programs
- 67 Control Unit / Switch Press Event Buttons
- 68 Security Mode Event Buttons
- 69 Zone Event Buttons
- 69 All On/Off Event Buttons
- 70 UPB Link Event Buttons
- 70 Alarm Event Buttons
- 70 X-10 Event Buttons
- 71 Miscellaneous Event Buttons
- 71 Message Event Buttons (Pro-Link)
- 72 Switch Press Event Buttons (CentraLite)
- 72 Edit Program Command
- 72 Program Control Commands
- 73 Unit Toggle Command
- 73 Program Security Commands
- 74 Program Button Commands
- 74 Program All On / All Off Commands
- 74 Program Video Commands
- 74 Program Temperature Commands
- 74 Program Energy Cost
- 75 Program Message Commands
- 75 Edit Program Condition
- 75 Program Control Conditions
- 76 Program Security Mode Conditions
- 76 Program Zone Conditions
- 76 Program Time Clock Conditions
- 76 Program Other Conditions
- 77 Set Up Dial
- 77 Telephone Access
- 77 Answer Outside Call
- 78 Remote Commands
- 78 Rings Before Answer
- 78 Dial Type
- 78 My Phone Number
- 78 Dial Out Number
- 79 Dial Out Numbers
- 79 Dial Order
- 79 Set Up Arming
- 79 Entry Delay
- 80 Exit Delay
- 80 Exit Time Restart
- 80 Unvacated Premises
- 80 Entry/Exit Chime
- 80 Perimeter Chime
- 80 Enable Quick Arm
- 81 Enable Auto Bypass
- 81 All On For Alarm
- 81 Beep On Trouble
- 81 Set up Miscellaneous
- 81 High Security Mode
- 81 Announce Alarms
- 82 Enable Freeze Alarm
- 82 Flash For Alarm
- 82 Console 1-8 Audible Exit Delay
- 82 House Codes 1-4 Format
- 82 House Codes 1-4 All Off
- 83 Time Clocks
- 84 Latitude, Longitude, and Time Zone
- 85 Daylight Savings
- 85 Controller IP Address
- 86 Controller Port Number
- 86 Encryption Key
- 87 Set Up Names
- 87 Set Up Voice
- 88 Set Up Address
- 89 FIRE ESCAPE PLANNING
- 93 INSTRUCTIONS TO CALLED PARTY