2 - Getting Started ST7MDT5-EMU2B Emulator User Manual
9
A CD-ROM containing ST7 information and software, including ST7 Visual
Debug and a Windows
®
Epromer. (Not shown.)
(3)
(1)
(2)
(4)
(h)
(5)
(6)
2.3
Figure 2: Main Components of ST7MDT5-EMU2B Emulator Kit
Installing the Hardware
The ST7 HDS2 emulator is connected through the parallel port to a PC computer which runs the control software (ST7 Visual Debug) as explained later. To connect your ST7 HDS2 emulator, you will have to follow these general steps:
1
Connect the ST7 HDS2 to your PC using the parallel cable provided.
2
Connect the two flat cables of your ST7 HDS2 emulator to the emulation probe connectors.
3
Connect the ST7MDT5-Active Probe to your application using the protective probe (ref.: DB374).
4
Connect the power supply cable between the power supply block and the power connector located on the rear panel of your ST7-HDS2 emulator.
5
Power up the emulator and then connect your application power supply.
10/65
ST7MDT5-EMU2B Emulator User Manual 2 - Getting Started
A connection flow diagram is shown in Figure 3 . Each installation step is described in detail in the following sections.
4
PC Parallel Port
1
Parallel Cable
Power Supply
2
ST7 HDS2 Emulator Casing
ST7 Active Probe
3
5
Application Board Power Supply
Application Board
Figure 3: STMDT5-EMU2B Connection Flow
Step 1: Connecting the Emulator to your PC
1
Shutdown and power-off the PC that is to be connected to the emulator.
2
Connect one end of the parallel cable to the emulator’s rear panel 25-pin SUB-
D connector and the other end to one of the PC’s parallel ports (LPT1 to
LPT2)—refer to Figure 4 .
Note:
Centronics (or PC-AT or SPP), ECP and EPP parallel port configurations are supported by the emulator.
11/65
2 - Getting Started ST7MDT5-EMU2B Emulator User Manual
Be sure to use the parallel cable provided with the emulator—using a longer parallel cables may cause emulator malfunctions.
to LPT1 or LPT2
1
2
rear panel
SUBD25 connector
Figure 4: Connecting the Emulator to the PC
Step 2: Connecting the HDS2 and the Probe
1
Ensure that the application and the emulator are powered-off.
2
Plug the two 50-wire flat cables into J1 and J2 connections on the probe, as described below (refer also to
Figure 5
):
ST7-HDS2 emulator
(ref.: MB176)
ST7MDT5-Active Probe
(ref.: DB374)
Upper cable
Lower cable
J2
J1
Red Line
50 pin Male Connector
J1 J2
ST7 HDS2
Side View
Figure 5: Connecting the Emulator to the Probe
3
EMC-Compliant Probes: In order to work under an EMC-compliant environment, you will have to clip one or two EMC-ferrites on each 50-wire flat cable linking the probe to the emulator box. Place these ferrites as close to the
12/65
ST7MDT5-EMU2B Emulator User Manual 2 - Getting Started
emulator window as possible. Three ferrites are provided in the package. See
Figure 6 for an illustration of where to attach the ferrites.
ST7 HDS2
Emulator
Side View
Ferrites
Probe +
Application Board
Flat Cables
Side View
Figure 6: Making your Probes EMC Compliant
Step 3: Connecting the ST7MDT5-Active Probe to your Application
The emulated MCU is available in two packages—the SDIP32 package and the
SO34 package. Accordingly, there are two possible connection schemes depending on the package you have chosen.
For the SDIP32 package, connect the emulation probe to your application board as follows (refer to Figure 7 ):
1
Connect the ST7MDT5-Active Probe with SDIP32 socket (ref.: DB374)to the protective probe (ref.: DB437).
13/65
2 - Getting Started ST7MDT5-EMU2B Emulator User Manual
2
Connect the ST7MDT5-Active Probe/Protective probe assembly to your application board.
ST7MDT5-ACTIVE PROBE WITH SDIP32 SOCKET (ref.: DB374)
Socket Adapter SDIP32
Protective Probe (ref.: DB437)
Application board
Figure 7: ST7MDT5-EMU2B with SDIP32 Socket Adapter
For the SO34 package, connect the emulation probe to your application board as follows (refer to Figure 8 ):
1
Connect the SO34 socket adapter (ref.: DB354 + DB355) to your application board. If the socket adapter is in two parts (as shown in
Figure 8
), connect
DB355 to your application board, then carefully insert the male connector of the
DB354 into the top of DB355.
2
Connect the ST7MDT5-Active Probe with SDIP32 socket (ref.: DB374)to the protective probe (ref.: DB437).
14/65
ST7MDT5-EMU2B Emulator User Manual 2 - Getting Started
3
Connect the ST7MDT5-Active Probe/Protective probe assembly to the SO34 socket adapter.
ST7MDT5-ACTIVE PROBE WITH SO34 SOCKET
Socket Adapter SDIP32
Protective Probe
DB354
DB355
SO34-Socket Adapter
Application
Figure 8: ST7MDT5-EMU2B with SO34 Socket Adapter
Step 4: Connecting the emulator power supply
Warning: Make sure that both the ST7MDT5-EMU2B and the application are OFF before making any connections.
1
Connect the external power supply provided with the emulator to the rear panel of the mainframe using a 5-pin DIN connector.
2
Plug the power supply into the mains using the supply cable provided.
Mains voltage specifications
AC voltage:
Frequency:
100 V to 240 V
50 to 60 Hz
Step 5: Powering up
1
Check the ST7-HDS2 operating voltage (110 V/220 V) indicated on the label on the power supply. Contact your dealer if this voltage does not correspond to your mains’ power supply.
2
Power up the ST7-HDS2 from the ON/OFF switch located on the rear panel.
The LED labelled Power on the front panel should then light up.
3
Power up your application.
15/65