advertisement
PELLET STOVES
INSTALLATION AND USE MANUAL
Chapter 9
page
56
9. ELECTRICAL DIAGRAMS
MOTHERBOARD WIRING KEY
1. Control panel
2. Room probe
3. Smoke probe red + blue -
4. Fuse
5. Switch
6. Sparkplug
7. Smoke exhaust fan
8. Gear motor
9. Contact thermostat
10. Air fan
11. Smoke exhaust fan revolution control white/red/black or blue
12. Timer-thermostat card
13. Timer-thermostat
14. Room thermostat
N.B. The electrical wiring of the single components includes pre-wired connectors which are of different sizes.
Electrical diagrams Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited
8901007301
MCZ GROUP S.p.A.
Via La Croce n°8
33074 Vigonovo di Fontanafredda (PN) – ITALY
Telephone: 0434/599599 r.a.
Fax: 0434/599598
Internet: www.mcz.it
e-mail: [email protected]
Rev 0 10/2010
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 5 INTRODUCTION
- 6 1. WARNINGS AND GUARANTEE CONDITIONS
- 6 SAFETY INSTRUCTIONS
- 7 OPERATING WARNINGS
- 8 GUARANTEE CONDITIONS
- 8 Limitations
- 9 Exclusions
- 10 2. THEORETICAL NOTIONS FOR INSTALLATION
- 10 PELLETS
- 11 PRECAUTIONS FOR INSTALLATION
- 12 OPERATING AREA
- 12 CONNECTION TO THE EXTERNAL AIR INTAKE
- 13 CONNECTION OF SMOKE DISCHARGE PIPE
- 14 CONNECTION TO THE FLUE PIPE
- 14 CONNECTION TO AN EXTERNAL FLUE WITH INSULATED OR DOUBLE-WALL PIPE
- 14 CONNECTION TO THE FLUE PIPE
- 15 OPERATING PROBLEMS CAUSED BY DRAUGHT DEFECTS IN THE FLUE
- 16 3. INSTALLATION AND ASSEMBLY
- 16 DRAWINGS AND TECHNICAL CHARACTERISTICS
- 16 FACE Air
- 16 KAIKA Air
- 17 Technical characteristics
- 18 PREPARATION AND UNPACK ING
- 21 CLADDING ASSEMBLY
- 21 KAIKA STOVE
- 23 FACE STOVE
- 24 MAKING THE ELECTRICAL CONNECTIONS
- 25 4. OPERATION
- 25 PRE-LIGHTING WARNINGS
- 26 PRE-LIGHTING CHECK
- 26 LOADING THE PELLETS
- 27 CONTROL PANEL/REMOTE CONTROL DISPLAY (accessory)
- 27 Control panel logic
- 29 SETTINGS TO CARRY OUT BEFORE FIRST LIGHTING
- 29 FIRST LIGHTING
- 29 ON/OFF from the control panel or remote control (if purchased)
- 29 Note on first ignition
- 30 Power supply (panel display: ON)
- 30 OPERATING MODE
- 30 Manual mode
- 31 Automatic mode
- 31 AUTOMATIC MODE SETTING
- 31 Changing from manual to automatic mode
- 31 Cleaning the grate
- 32 HOT AIR VENTILATION
- 32 Room sensor
- 33 5. MENU STRUCTURE
- 33 The menu allows you to set/change a series of information
- 33 MAIN MENU
- 33 Setting current day and time
- 35 TIMER
- 35 TIMER activation and selection of a programme
- 36 DETAILS OF TIMER OPERATION
- 36 TIMER de-activation
- 37 SLEEP FUNCTION
- 37 Menù IMPOSTAZIONI
- 37 Setting the language
- 38 Automatic mode with AUTO-ECO (panel display: ON-AUTO ECO)
- 39 Mode AUTO-ECO
- 39 Tones (Panel display: ON-OFF)
- 39 Pellet recipe - modifying the load
- 40 Changing the smoke exhaust fan speed – Var.% smoke rpm
- 41 Connection to a room thermostat
- 42 Operating mode with external thermostat
- 43 Operating mode with external thermostat and Eco-Stop
- 44 Remote control (accessory)
- 45 General characteristics of the LCD remote control
- 45 Type of batteries and replacement
- 45 Hopper load (ON-OFF - only displayed with stove off)
- 46 Technical menu
- 46 INFO menu
- 47 6. SAFETY DEVICES
- 47 ALARM SIGNALLING
- 48 Exiting alarm condition
- 48 Normal shutdown (panel display: shutdown)
- 50 7. MAINTENANCE AND CLEANING
- 50 DAILY AND WEEKLY CLEANING BY THE USER
- 50 Before each lighting
- 50 Check every 2/3 days
- 50 Cleaning the glass
- 51 PERIODIC CLEANING BY A SPECIALISED TECHNICIAN
- 51 Cleaning of the heat exchanger
- 52 Shutting the stove down (end of season)
- 52 Check of internal components
- 53 8. PROBLEMS / CAUSES / SOLUTIONS
- 56 9. ELECTRICAL DIAGRAMS