Horizontal. Digital Processing Systems DPS-470
Advertisement
Advertisement
ntsc-pal-141.qxd 4/4/00 2:25 PM Page 15
Chapter 3:
Operation
• Range: +/– 9.5 µs
• Subcarrier Fine: increments of 0.156 degrees
• Subcarrier Coarse: increments of 1.406 degrees
• Range: 0 - 360 degrees
By pressing the TIMING button multiple times, the DPS-470 cycles through the above selections. Use the control knob to set the exact timing.
Horizontal
(Button appears on the PAL front panel only)
Adjusts the horizontal genlock timing. Adjustments are:
• Horizontal Fine: increments of 2.314 ns
• Horizontal Coarse: increments of 74.074 ns
• Range: +/- 9.5 µs
Mem
The Memory button accesses the Store and Recall functions.
Store
Allows the current Proc Amp settings to be stored in the memory location selected using the control knob. Up to 10 settings can be stored, containing information on Video, Black, Chroma and Hue. Valid Store locations are numbered 001 - 010; location 000 is reserved for factory preset unity. To store a Proc Amp setting:
1 Press the MEM button
2.
Use the control knob to select Store and press the MEM button again
3.
Use the knob to select a memory location and press MEM again
Recall
Allows previously stored Proc Amp settings to be recalled. To recall:
1.
Press the MEM button
15