Code 39. Psion Teklogix PowerScan 7000
Реклама
Реклама
Code 39
Code 39
The following options apply to the Code 39 symbology.
Disable/Enable Code 39
When this feature is disabled, the scanner will not read Code 39 bar codes.
Check Character Calculation
When enabled, the scanner will calculate the check character of the labels. Turn this option on only when a checksum is present in the Code
39 labels.
Check Character Transmit
Enable this option to transmit the check character with scanned bar code data.
Start/Stop Characters
Enables/disables transmission of Code39 start and stop characters.
Code 39 Full ASCII
Enables/disables the translation of Code 39 characters to Code 39 full-
ASCII characters
User Manual 5-35
Symbologies
Code 39 — continued
START
STATE BAR CODE
Disable
Code 39
Enable
Code 39
Disable
Check Char
Calculation
Enable
Check Char
Calculation
Disable
Check Char
Transmission
Enable
Check Char
Transmission
5-36 PowerScan® 7000 SRI
Code 39 — continued
START
STATE
Don’t Transmit
Start/Stop
Characters
BAR CODE
Transmit
Start/Stop
Characters
Disable
Code 39 Full
ASCII
Enable
Code 39 Full
ASCII
END
Code 39
User Manual 5-37
Symbologies
Code 39 — continued
Length Control
Fixed Length Decoding —
When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.
Variable Length Decoding —
When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length.
Configuring Fixed Length Decoding:
1. Scan the START bar code.
2. Scan the Fixed Length Decoding bar code.
3. Scan the END bar code.
4. Set Length 1 to the first fixed length by following the
Length 1, Length 2 Programming Instructions
below.
5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the
Code 39 Length 1, Length 2 Programming Instructions
below.
Configuring Variable Length Decoding:
1. Scan the START bar code.
2. Scan the Variable Length Decoding bar code.
3. Scan the END bar code.
4. Set Length 1 to the minimum length by following the
Length 1, Length 2 Programming Instructions
below.
5. Set Length 2 to the maximum length by following the
Length 1, Length 2 Programming Instructions
below.
5-38 PowerScan® 7000 SRI
Code 39 — continued
START
MODE
Variable
Length
Decoding
BAR CODE
Fixed Length
Decoding
END
Code 39
User Manual 5-39
Symbologies
Code 39 Length 1, Length 2 Programming
Instructions
1. Scan the START bar code.
2. Scan either the Set Length 1 or Set Length 2 bar code.
and scan the three digits
(zero padded) representing the length in decimal notation.
For Code 39 bar codes, all check, data and full ASCII shift characters are included in the length calculations.
Start/Stop characters are not included.
NOTE
4. Scan the END bar code.
SETTING BAR CODE
Set Length 1
DEFAULT SETTING FOR THIS FEATURE: 003
Set Length 2
DEFAULT SETTING FOR THIS FEATURE:
050 decimal
END
5-40 PowerScan® 7000 SRI
Code 39
Code 39 — continued
Quiet Zones
This feature enables/disables the requirement that quiet zones must be present for Code 39 bar codes.
START
STATE
Don’t require
Quiet Zones
BAR CODE
Require Quiet
Zones
END
User Manual 5-41
Symbologies
Code 39 — continued
Code 39 Stitching
Enables/disables stitching for Code 39 labels. When parts of a Code 39 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met.
START
STATE
Disable
Code 39
Stitching
BAR CODE
Enable
Code 39
Stitching
END
5-42 PowerScan® 7000 SRI
Code 39
Code 39 — continued
Minimum Reads
This feature specifies the minimum number of consecutive times an
Code 39 label must be decoded before it is accepted as good read.
START
READS
Minimum =
1 Read
BAR CODE
Minimum =
2 Reads
Minimum =
3 Reads
Minimum =
4 Reads
END