Module/

Component

Backplane

Basic

PEC Comcode

106388614

107007114

Apparatus

Code

403E

403G

Expansion

Power Supply

120 V

61490

61450

106388630

107007122

105743801

106257199

107184848

403F

403H

391A1

391A2

391A3

220 V

Auxiliary

Processor

R1.0/2.0

Secure

Hong Kong

Czech

106678931

107184855

391B1

391B2

61416 406467142

106215155

90240-3

517A27

107096869 517A27-F

107221434

107628133

517A27(16)

517A27(34)

124

Technician’s Addendum

Release Used In

All

HW

Vint FW Vint Notes

Used in control units 6140-

CU1, 6140-CU2, 6140-CU3,

6140-INT, 6140-220, 6140-

CUL, 6140-P3C, 6140-P3D,

6140-P3E, 6140-P4D, 6140-

P4F and 6140-SEC

All

All non-US

All US

1.0, 2.0

1.1, 2.1

1.2i, 1.3i, 1.4i

2.0, 2.1

1.2i, 1.3i, 1.4i

1.2i, 1.3i, 1.4i

00

05

01

Used in control units 6140-

CU1, 6140-CU2, 6140-CU3,

6140-INT, 6140-220, 6140-

CUL, 6140-P3C, 6140-P3D,

6140-P3E, 6140-P4D, 6140-

P4F and 6140-SEC

Used in control unit 6140-220 and in expansion units 61450 and 61497

No longer available

Used in control units 6140-

CU2, 6140-INT, 6140-INT, and 6140-220

For Federal Systems; used in control unit 6140-SEC

For Hong Kong

For Czech Republic

125

Technician’s Addendum

Module/Component History (

continued )

Module/

Component

Processor (cont’d)

R3.0

PEC Comcode

107040438

Apparatus

Code

517A33

107438921 517B33

R3.1

R4.0

Feature Module

R1.0

107752693 517D33

107743403 517C33

106064660

106656739

106729031

106767767

517A25

517B25

517C25

517C25B

106743008

106743016

517D25

517E25

126

Technician’s Addendum

Release Used In

3.0

1.0

1.0

1.0

1.0

3.1

4.0

1.1

1.1

* SW = software

HW

Vint

01

02

02

02

FW Vint

SW* = 1.0

V14.7

SW = 1.0

V14.9

SW = 1.0

VEAL

(14.10)

SW = 1.1

V5.2

Notes

ML R3.0 or later; no FM used; used in control units 6140-

CU3, 6140-P3C, 6140-P3D,

6140-P3E, 6141-U3LA, 6141-

103A

ML R3.0 or later; no FM used; higher temperature reliability; no watch point registers; used in control units 6140-CU3,

6140-P3C, 6140-P3D, 6140-

P3E, 6141-U3LA, 6141-103A

Used in control units 6140-

CU3, 6140-P3C, 6140-P3D,

6140-P3E, 6141-U3LA, 6141-

103A

Used in control units 6140-

CU3, 6140-P3C, 6140-P3D,

6140-P3E, 6141-U3LA, 6141-

103A

GA version

See QPPCN 244 MT.

See QPPCNs 244MTS1 and

251MT.

See QPPCN 254MT.

GA version

See QPPCN 260MT.

127

Technician’s Addendum

Module/Component History (

continued )

Module/

Component

Feature Module

(cont’d)

R1.1

PEC Comcode

106825888

106999873

106999899

R2.0

106874738

106874746

R2.1

NI-BRI (R2.B)

R1.2i

R1.3i

R1.4i

PCMCIA Card

Backup/Restore 61501

Apparatus

Code

517F25

517F25B

517F25C

517G25

517H25

106874753

107526352

106999824

107499170

106796949

106875750

106875768

107252728

517J25

517J25B

517K25

517K25B

517A30

517B30(28)

517C30

517D30

107245243 10A1

R3.0 SW Upgrade

R3.0 Forced Install

R3.1 SW Upgrade

R3.1 Forced Install

R4.0 SW Upgrade 61506

107245250

107245268

107655201

107752743

107752677

107741274

10B1

10C1

10C2

10B2

10C3

10D1

128

Technician’s Addendum

3.0

3.0

3.1

3.1

4.0

1.1

1.1

1.1

2.0

2.0

2.1

2.1

NI-BRI (2.B)

NI-BRI (2.B)

1.2i

1.3i

1.3i

1.4i

Release Used In

HW

Vint FW Vint Notes

SW = 1.1

V5.3

SW = 1.1

V7.3

SW = 1.1

V7.7

SW = 2.0

V8.2

SW = 2.0

V8.3

SW = 4.0

SW = 4.9

SW = 9.2

SW = 9.6

See QPPCN 266MT.

See QPPCN 292MT.

See QPPCN 308MT.

See QPPCN 279MT.

See QPPCN 290MT.

See QPPCN 307MT.

See QPPCN 406MT

Pre-GA

GA version

3.0 and higher

SW = 8.0

GA version

Included in 6141-INT and

6141-220

Translation card for R3; also included as part of processor

PEC

Contains R3V10.3

R3V10.0

R3V10.3

Contains R3.1V2.0

Contains R3.1V2.0

Contains R4.0V9.0

129

Technician’s Addendum

Module/Component History (

continued )

Module/

Component

PCMCIA Card

(cont’d)

R4.0 Forced Install

008 ATL

PEC

61385

61485

Comcode

107741241

103983508

105351092

Apparatus

Code

10E1

517A3

517B3

008 MLX

008 OPT

Without Ring

Generator

61486

61489

105628010

106387525

106933187

106980162

107009821

106995269

517A21

517A28

517B28

517C28

517C28B

517D28 With Ring Generator

61479

012 TR

Without Ring

Generator

With Ring Generator

Ring Generator

61387 or

61487

61494 or

61459

61388

61498

107321192

105249023

105461545

105512412

106397631

106553779

106767379

106933773

107108698

107438939

105213201

106741788

517D28A

517A13

517B13

517C13

517D13

517E13

517F13

517G13

517G13(28)

517H13

129B

129C

130

Technician’s Addendum

Release Used In

HW

Vint FW Vint Notes

4.0

All

All

All

All

All

All

0.1

0.1

0.4

0.4

05

01

01

01

01

01

02

03

03

03

04

05

05

05

01

02

03

04

70

32

33

34

0.B

0.B

1.1

1.3

11

12

14

15

16

16

17

18

08

08

08

Contains R4.0V9.0

Reduced package; no telephone user’s guide

Fixes ring patterns and ring trip

Eliminates flash during hang-up

Eliminates flash during answer

Built-in ring generator

Enhances ringing on long loops

REN >5

Enhanced battery feed protection

Forward disconnect added; need for Voice Mail

Improve performance of inductive ringers

Meets EIA transmission standards for use with

MEGACOM® services

Built-in ring generator;

REN <+1

REN increased to 2.4

REN increased to

=

4.0

Required for 517A13—517F13

131

Technician’s Addendum

Module/Component History (

continued )

Module/

Component

016 TR

100D (DS1)/T-1

400 EM TIE

400 (w/TTRs)

PEC

61507

61491

Comcode

107824948

107538887

105461560

105512438

61492

8303-200

61379

105311401

105408892

Apparatus

Code

517B34

517A15

517B15

517C15

517E15

517A14

517B12

400 GS/LS/TTR

400 LS

61483

61384

400 LS/TTR Int’l (DTD) 61452

408 GS/LS/ATL 61481

408 GS/LS MLX

408 LS/ATL

800 NI-BRI

800 NI-BRI

61493

61482

61503

61510

105627988

105628044

107044869

103983490

105351084

106819238

107732018

106064678

106939366

107044877

106698590

107044851

517A18

517B18

517C18

517A2

517B2

517B12(28)

517C12(28)

517A26

517B26

517C26

517A29

517B29

103983482

105351076

105512495

107025793

107731127

517A1

517B1

517C1

517A32

517A35

132

Technician’s Addendum

Release Used In

4.0, 1.4i

All

HW

Vint FW Vint Notes

Tie trunk only

LS, GS, DID, and PRI emulation added

Meets BC interoperability specs

Improved EMI performance

All

All 01 0.B

All U.S.

1.2i, 1.3i, 1.4i

All U.S.

All US 2.0 or later

All

NI-BRI (2.B)

4.0

03

03

03

04

04

04

01

01

01

00

1.1

1.2

1.3

11

12

13

28

29

0.B

0.B

0.B

70

Lightning protection added; starting in 1996, replaced by

517C12(28)

Sleeping TTR fix

Phantom ringback fix

No lightning protection; 146 protector required

Lightning protection added

Includes LG80 crosstalk fix

Reduces clicking on third carrier

Phantom ringback fix

Cost-reduced version; current production

Withdrawn from production

No lightning protection; 146A protector required

Protection added

Reduced packing; no telephone user’s guide

Supports 5ESS® Custom

Supports ISDN 1 standard

133

Technician’s Addendum

Module/Component History (

continued )

Module/

Component

800 DID

PEC

61488

Comcode

105628002

105628077

106936644

800 GS/LS

800 GS/LS ICLID

800 LS

61484

61502

61384

106995251

105627996

105628069

106975584

103983516

105351100

800 LS Int’l

800 LS Int’l

(DTD/PPM)

E1

75 Ohm

61451

61458

61454

106819220

107074726

107252736

106825896

120 Ohm

MFC 6-Channel

61457

61456

107100133

107533861

106825904

Apparatus

Code

517A20

517B20

517C20

517D20

517A19

517B19

517A31

517A4

517B4

517B4(28)

517C4(28)

517D4(28)

517C15(28)

517E15(28)

517D15(28)

517F15(28)

517C16(28)

134

Technician’s Addendum

Release Used In

All

All US

3.0 or later

All

1.2i, 1.3i

1.3i, 1.4i

0.1

0.1

0.2

02

HW

Vint

01

02

03

04

03

03

FW Vint

11

01

12

17

1.1

1.2

0.B

0.B

0.CD

E4

Notes

Fixes DID call misrouting

Eliminates false error messages

Cost-reduced version

Phantom ringback fix

No lightning protection; 146A protection required

Introduces dual solid-state relays on lower board

PFT polarity fix

1.3i, 1.4i

EMI improvement

1.3i, 1.4i

1.3i, 1.4i

EMI improvement