DS4800 Reference Manual


Add to my manuals
124 Pages

advertisement

DS4800 Reference Manual | Manualzz

25-PIN CABLE ELECTRICAL CONNECTIONS

5

5.5 INPUTS

There are two optocoupled polarity insensitive inputs available on the scanner: Input 1

(External Trigger) and Input 2, a generic input:

The electrical features of both inputs are:

Maximum voltage: 30 Vdc

Maximum current: 12 mA

An anti-disturbance filter is implemented in software on both inputs so that the minimum pulse duration is

 5 milliseconds. This value can be increased through the software parameter Debounce Filter, see the "2K/4K Family Software Configuration Parameter Guide”

Help file".

25-pin

9

Name

Vdc

Function

Power Source - External Trigger

18

19

I1A

I1B

External Trigger A (polarity insensitive)

External Trigger B (polarity insensitive)

7 GND Power Reference - External Trigger

The External Trigger input is used in the On-Line operating Mode and tells the scanner to scan for a code. The active state of this input is selected in software. Refer to the Genius™

Help On Line.

The yellow Trigger LED (

Figure A

, 3) is on when the active state of the External Trigger corresponds to ON.

This input is optocoupled and can be driven by both an NPN and PNP type command. The connections are indicated in the following diagrams:

EXTERNAL TRIGGER INPUT PNP PH-1

DS4800

PNP PH-1 wires

9

Vdc

(brown) +10-30 Vdc

18

I1A

(black) NO

V

CC

+

~

~

-

19

I1B

7

GND

(blue) 0 V

Figure 58 - PH-1 Photocell (PNP) External Trigger Using DS4800 Power

71

DS4800 REFERENCE MANUAL

5

EXTERNAL TRIGGER INPUT CONNECTIONS USING DS4800 POWER

DS4800

9

Vdc

I1A

EXTERNAL TRIGGER

V

Signal

18

V

CC

+

~

~

-

19

I1B

7

GND

Ground

Figure 59 - PNP External Trigger Using DS4800 Power

DS4800 EXTERNAL TRIGGER

9

Vdc

V

18

I1A

V

CC

+

~

~

-

19

I1B

GND

Signal

7

Ground

Figure 60 - NPN External Trigger using DS4800 power

EXTERNAL TRIGGER INPUT CONNECTIONS USING EXTERNAL POWER

DS4800

V

CC

~

+

-

~

18

19

Vext 30 Vdc max.

EXTERNAL TRIGGER

V

I1A

Signal

I1B

Figure 61 - PNP External Trigger Using External Power

DS4800

Vext 30 Vdc max.

EXTERNAL TRIGGER

18

I1A

V

CC

I1B

V

~

+ -

~

19

Signal

Figure 62 - NPN External Trigger Using External Power

72

25-PIN CABLE ELECTRICAL CONNECTIONS

25-pin

9

6

10

7

Name

Vdc

I2A

I2B

GND

Function

Power Source Inputs

Input 2 A (polarity insensitive)

Input 2 B (polarity insensitive)

Power Reference - Inputs

INPUT 2 CONNECTIONS USING DS4800 POWER

DS4800

V

CC

+

~

~

-

9

6

10

7

GND

Vdc

I2A

I2B

INPUT DEVICE

V

Signal

Ground

Figure 63 - PNP Input 2 Using DS4800 Power

DS4800

V

CC

+

~

~

-

9

6

Vdc

I2A

10

7

I2B

GND

INPUT DEVICE

V

Ground

Signal

Figure 64 - NPN Input 2 Using DS4800 Power

INPUT 2 CONNECTIONS USING EXTERNAL POWER

DS4800

V

CC

~

+

-

~

6

10

Vext 30 Vdc max.

EXTERNAL TRIGGER

V

I2A

Signal

I2B

Figure 65 - PNP Input 2 Using External Power

DS4800

V

CC

~

+

-

~

6

10

Vext 30 Vdc max.

EXTERNAL TRIGGER

I2A

I2B

V

Signal

Figure 66 - NPN Input 2 Using External Power