READING FEATURES

7.4.2 X1XX Oscillating Mirror Models

DS4800-X1XX

Focus Distance 30 cm (Near)

0 15

0 10 20 30 40 50 60 70 80

20

50

35 40

(in)

90 100

15

40

10

30

20

5

10

0 0

 0.50 mm

(20 mils)

10

5

20

10

30

15

40

0.20 mm

(8 mils)

0.30 mm

(12 mils)

0.38 mm

(15 mils)

20

50

(in)

(cm)

NOTE: (0,0) is the center of the laser beam output window.

CONDITIONS

Code =

"Pitch" angle

"Skew" angle

"Tilt" angle

= 0 

= 15

= 0

 to 30

= 800 scans/sec. *Scan Speed

*Reading Condition

* Reading Mode

= Standard

= Linear

 Parameter selectable in Genius™

For Tilt angles of 45°, the reading performance is reduced by approximately the following values:

Minimum reading distance: +20%

Maximum reading distance: -30%

Maximum reading width: -15%

7

95

DS4800 REFERENCE MANUAL

7

20

50

0

0

DS4800-X1XX

Focus Distance 40 cm (Medium)

10 20 30

15

40 50 60 70

15

40

10

30

20

5

10

0 0

10

5

20

10

30

15

40

0.30 mm

(12 mils)

 0.50 mm

(20 mils)

0.38 mm

(15 mils)

20

50

(in)

(cm)

NOTE: (0,0) is the center of the laser beam output window.

CONDITIONS

80

35 40

(in)

90 100

"Pitch" angle

"Skew" angle

"Tilt" angle

*Scan Speed

*Reading Condition

= 0 

= 15 

= 0  to 30

= 800 scans/sec.

= Standard

* Reading Mode = Linear

* Parameter selectable in Genius™

For Tilt angles of 45°, the reading performance is reduced by approximately the following values:

Minimum reading distance: +20%

Maximum reading distance: -25%

Maximum reading width: -15%

96

READING FEATURES

DS4800-X1XX

Focus Distance 60 cm (Far)

60

20

50

0 15 35 40 45

(in)

0 10 20 30 40 50 60 70 80 90 100 110 120

15

40

30

10

20

5

10

0 0

5

10

20

10

30

15

40

0.38 mm

(15 mils)

 0.50 mm

(20 mils)

20

50

(in)

60

(cm)

NOTE: (0,0) is the center of the laser beam output window.

CONDITIONS

"Pitch" angle

0.90

= 0

"Skew" angle

"Tilt" angle

= 15 

= 0  to 30

*Scan Speed

*Reading Condition

= 800 scans/sec.

= Standard

* Reading Mode = Linear

* Parameter selectable in Genius™

For Tilt angles of 45°, the reading performance is reduced by approximately the following values:

Minimum reading distance: +20%

Maximum reading distance: -15%

Maximum reading width: -15%